Compiled by Dr. Gavan O Connell. Thermafil CLINICAL HINTS

Similar documents
Universal Endo System Directions for Use. ProTaper

Removal of a fractured instrument with a new extractor: clinical cases

SuperEndo B&L-alpha II Cordless Heat Carrier Operation & Maintenance Instruction Manual

Precision Endodontic System. Precision Obturation System. So sophisticated, it s simple

Feel the Safety and Control

Root Canal Retreatment: 2. Practical Solutions T.R. PITT FORD AND J.S. RHODES

Mani Silk: A new and novel means of predictable canal shaping

Endo Easy Efficient Sonic Powered Endo Irrigation

Complete Denture Processing Luther A. Ison, CDT

Florida Method of Test for TESTING OF GROUND TIRE RUBBER Designation: FM 5-559

The efficacy of gutta-percha removal using ProFiles

ArtisanLink Staining System is an automated special stains slide

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Instructions for Using the Watch Works Tool Kit to Change a Watch Battery

DryWeight BulkVolume

Restoring the Endodontically Treated Tooth:Post and Core Design and Material 根 管 治 療 後 牙 齒 的 修 復 :Post and Core 的 設 計 與 材 料

Fixing Dental Implant Component Failure and Fracture: Retrieving the Fractured Implant Abutment Screw. Charles A. Mastrovich, DDS

Standard Test Procedures Manual

ENDO REMOVAL SYSTEM Set of endodontic micro instruments for removing broken canal instruments

ULTRASONIC TREATMENT ENDODONTICE

Dental Radiography collimator Ionising radiation image radiolucent area radiopaque area controlled zone scatter radiation intraoral

Contributions regarding FEM for an ultrasonic endodontic device and his appliance in the root canal treatments

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

The WaveOne single-file reciprocating system

Root ZX II Endodontic Predictability Apex Locator with Low Speed Handpiece. Thinking ahead. Focused on life.

Solvent Cementing Instructions For Plastic Pipe & Fittings

UV100A Ultraviolet Air Treatment System

Precision Vise Combinations

2-SLICE COOL TOUCH TOASTER

Totally lightweight, totally flexible, totally titanium.

Brisa UV Gel Enhancements Sculpted on a Tip

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

Analysis of forces developed during root canal filling by different operators

Implant Systems MAX LOGIC MONO. Today s name in tomorrow s implant technology

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

RomiApex A-15. APEX LOCATOR User Manual

CanalPro TM Apex Locator

TrūShine Gel Enamel FAQs

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

INJECTION MOULD DESIGN: MARPLEX PVC RESINS

METHOD A10 (a) THE DETERMINATION OF THE IN-PLACE DRY DENSITY OF SOIL OR GRAVEL BY THE SAND REPLACEMENT METHOD

OPERATING INSTRUCTIONS

Step-by-Step Guide. ENHANCEMENTS Brisa UV Gel Enhancements Rebalancing. STEP 1: Cleanse

Dentaport ZX Reliable Apex Location Perfect Endodontics Curing with High-Powered Parallel Precision

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Accurate Air Flow Measurement in Electronics Cooling

Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

Caring for Your PleurX Pleural Catheter

We make a point of ensuring safety.

Current developments in rotary root canal instrument technology and clinical use: A review

EEG Cap Instructions

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

This is the civilian transfer case with the cooling loop only found in the driven gear half of the front case.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time

Endodontic Mishaps DETECTION OF MISHAPS ENDODONTIC MISHAPS

Restoration of Endodontically Treated Teeth

Jeep Wrangler Diagnosis & Repair Manual Water Leaks

The Drink-Aide The NEW look of independence

NIH Clinical Center Patient Education Materials Giving a subcutaneous injection

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

DASH KIT INSTALLATION

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.

Air. Air and light. Light

Q&A Session for Advanced Ball Screws 102: Troubleshooting for Design Engineers

Curved Quadrant Instruction Manual

Roller Chain Coupling

Almond SPAMANICURE. Step-by-Step Guide INDULGENT AND RELAXING

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

1.8 CRANKSHAFT OIL SEALS

Dental Clinical Criteria and Documentation Requirements

Universal Crown and Bridge Preparation

SC, FC and ST * Hot Melt Fiber Optic Connectors

SHELLAC Brand Application & Removal

Achieving Independence

A Guide to Trouble-Free Cooling Towers

Determination of Moisture Content

INSULIN INJECTION KNOW-HOW

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

METHOD A7 THE DETERMINATION OF THE MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT OF GRAVEL, SOIL AND SAND

Endodontic treatment with MTA apical plugs: a case report

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Wall Mount Installation and Use

Promoting safer use of injectable medicines

Record Cleaning Machine

BRAVO FF-SERIES INSTALLATION INSTRUCTIONS BRAVO FRP FLANGE FITTINGS FOR SINGLE WALL FRP SUMPS ONLY AMERON LCX COAXIAL FIBERGLASS PIPE ONLY

Ceramic Glass Electric Galley Ranges

How to Prepare Formula for Bottle-Feeding at Home

SCREEN PRINTING INSTRUCTIONS

The Analytical Balance

Multiple flasks. Easy to adapt. Stuart range of heating blocks

Using the Surface Zeta Potential Cell Kit

Application Note. Soldering Methods and Procedures for 1st and 2nd Generation Power Modules. Overview. Analysis of a Good Solder Joint

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Hearing aids reveal and retain the world of words and sounds. Hearing aids sharpen your sense of hearing in a new way

Tipping Bucket Rain Gauge Models 6011-A 6011-B

Transcription:

Compiled by Dr. Gavan O Connell M.D.Sc (Melb) L.D.S. (Vic) Thermafil CLINICL HINTS

Thermafil Thermafil is a patented endodontic obturator consisting of a flexible central carrier that is uniformly coated with a layer of refined and tested alpha phase gutta-percha. When heated, the alpha phase gutta-percha becomes sticky and tacky, with excellent flow characteristics and obturates the canal and available lateral and accessory canals. The Thermafil carrier is a flexible 25mm biocompatible radiopaque plastic material with a.04 taper. Successful endodontic treatment begins with proper canal access, debridement, and cleansing and shaping. Unless these procedures are carried out thoroughly, and an effective coronal seal is used, success cannot be guaranteed irregardless of obturation technique. Please refer to Maillefer Profile and ProTaper Clinical Hints for recommendations on canal preparation. Note also that the Thermafil technique can be used after canal preparation with conventional files used in a step-back technique. The Thermafil technique was first introduced in the late 1980s, and the clinical studies have compared favourably to the Lateral Condensation technique. The greatest feature of Thermafil is that it is so quick and easy to learn. No longer is there the need to use lateral spreaders and multiple accessory gutta-percha points. n instructional video is also available. Contact your local Dentsply Territory Manager for more details.

Thermafil Obturation Procedure uick Guide 1 dminister anaesthesia This is generally necessary because the insertion of the Thermafil obturator creates a slight apical pressure that can cause some discomfort. Rather than have the possibility of the patient experiencing pain during obturation, it is preferable to administer anaesthesia beforehand. 2 3 Determine final working length fter cleansing, debridement and shaping, confirm final working length using an appropriate Thermafil verifier that reaches the apical constriction passively with no significant resistance or twisting. Because the Thermafil nickel titanium verifiers are fluted, a tight-fitting verifier can be made to fit passively with a few rotations, if necessary. Select obturators Select a Thermafil obturator the same size as the best fitting verifier previously selected. 4 sepsis (suggested procedure only) Disinfect the obturator in 5.25% sodium hypochlorite solution for one minute. Rinse it in 70% alcohol, then leave to air dry for several seconds to allow evaporation of excess alcohol. 5 Mix sealer s the obturator dries, mix the root canal sealer. We recommend using H Plus or H26. These sealers are biocompatible and have properties that allow for excellent lubrication and adhesion, ample working time, and long-term stability. continued overleaf...

Obturation Procedure uick Guide (continued) Thermafil 6 7 8 Heat the obturator in the Thermaprep Plus Oven See instructions for operation on page 5 & 6. Dry canal and apply sealer Before applying sealer, thoroughly dry the canal, then place a very small amount of sealer on a paper point or file and distribute a light coating evenly along the canal walls. Excessive sealer is neither necessary nor desirable for this technique. However, sealer is mandatory. Obturate canal(s) Using firm (straight-line) apical pressure (no twisting or rotating), insert the Thermafil obturator into the canal to the previously determined working length. Do not force the carrier beyond working length or twist it during insertion. 9 Remove shaft and handle Stabilise the carrier with your index finger and sever the shaft level with the orifice using a suitable Prepi bur or an appropriate high-speed round bur. Note that extreme care needs to be taken if attempting to sever the shaft with a flame heated instrument. The instrument may cool too rapidly and cause inadvertent obturator displacement from the canal. Use a suitably sized plugger for extra vertical condensation. If required, an accessory gutta-percha point may be used. 10 Post space For best results in creating post space, use the Pro-Post eccentric tip drill. Many of the well-known post drills have a non-cutting tip and are ineffective in creating post space for Thermafil.

Thermafil Thermaprep Plus Oven Instructions For Operation 1 Connect the oven to 240V mains voltage and turn the oven on with the switch at the back. The green stand-by light should illuminate. 2 Put both slide-holders in the upper position by pressing the back of the holder (arrow up). Gently ease it up with your finger. 3 Place the Thermafil obturator in the left slide-holder. The rubber stop needs to be under the holder. 4 Push the holder down (arrow down) until it clicks. Do not use excessive pressure or attempt to push the slide-holder down using the back of the holder (i.e. the arrow up part). 5 Push the button that corresponds with the obturator you have selected e.g. size 20 25. Now push the button with start left. The obturator is being heated. Depending on size of Thermafil obturator selected, the warming up time varies from approximately 15 to 35 seconds and is regulated automatically. continued overleaf... 5

Thermafil Thermaprep Plus Oven Instructions For Operation (cont d) 6 fter the first signal (beep) the obturator is ready for use. Gently ease the slide-holder up (arrow up). Take the obturator out of the holder in a forward direction and not up. If you are not ready for the obturator at the first beep then leave it in place. The oven will keep the obturator at the right temperature and ready for use for the next 2 minutes. Every 15 seconds, during this 2 minute period, the oven will beep to remind you that the Thermafil is ready for use. fter 2 minutes the Thermaprep oven switches off automatically. 7 When you have taken the obturator out of the holder, you can switch off the Thermaprep oven by pushing the start button again. During the warming-up cycles you cannot interrupt the process. 8 If you want to heat more obturators, you can vary the use of the left and the right slide-holder so you can go on with your work efficiently. fter the first beep you can immediately use the other slide-holder. 6

Thermafil Frequently sked uestions Is Thermafil available with non-plastic carriers? No. Maillefer only produces plastic carriers. Must I use the oven to heat the Thermafil? Yes, this is mandatory. Thermafil plastic carriers should never be heated with a flame. re Thermafil obturators sterilised? Strictly speaking, gutta-percha is not sterilised through and through; it is disinfected. The instructions explain a recommended procedure for disinfection prior to use which is very effective in killing vegetative microorganisms and spore forms. How important is complete drying of the canal? Very important. Moisture in the canal can contaminate the sealer to ineffectiveness, and wet the dentine causing impaired adherence of sealer and gutta-percha. Moisture pushed into the periapex during canal obturation has been linked as a possible factor in postoperative pain. Does Thermafil require sealer? Yes for two reasons. First, it provides lubrication for the thermoplasticised mass as it proceeds apically down the canal during insertion, and second, it provides an adhesive micro-interface between the gutta-percha and dentinal wall. Research has shown gutta-percha obturations to be sealer dependent. 7

Frequently sked uestions Thermafil What is the recommended sealer quantity? Place a small amount of sealer on a paper point and distribute evenly, as a light coating, along the canal walls. This has been shown to reliably produce a micro-thin, uniform sealer interface between the gutta-percha and dentine. How do I fill a canal that is longer than 25mm.? Plastic carriers are designed with this situation already in mind. The measurement calibrations are set at 18, 19, 20, 22, 24, 27 and 29mm. Larger than this simply notch the handle at the required length. Must I change my instrumentation technique? No. Normal preparation with hand, mechanical or a combination of these methods is acceptable. The important feature to remember is to use the obturator that corresponds to the verifier of best fit (which will not necessarily be a match with the last file used). I prefer to use ProTaper files to clean and shape my canals. Can I still obturate with Thermafil? bsolutely. ProTaper gives the ideal shape for the easy application of Thermafil. Is Thermafil conventional gutta-percha? Yes. The gutta-percha commonly used in dentistry is beta phase. lpha phase has the same chemical formula, but has been annealed by a proprietary process to achieve a more linear crystalline structure, resulting in different physical properties. When heated, alpha phase becomes exceedingly sticky and tacky, and has excellent flow characteristics. This heated gutta-percha exhibits a wetting phenomenon that causes it to adhere to the carrier. The flow properties allow the gutta-percha to obturate available lateral and accessory canals.

Frequently sked uestions Thermafil The gutta-percha seems to be stripping off the carrier and gathering at the orifice. What is the situation here? This appearance is normal. The obturator has been designed with excess gutta-percha to accommodate even the most widely flared canals; the accumulation at the orifice is excess gutta-percha backflowing coronally, not gutta-percha that has been stripped away from the carrier. Due to the wetting phenomenon of alpha phase gutta-percha, a thin layer remains on the carrier at all times if the obturator has been heated properly. The final proof is in the excellent results that Thermafil has achieved in minimising leakage as seen in dye study test results. How long do I have from the time I heat the obturator until the time I insert it into the canal? You have approximately 8-10 seconds to insert the obturator after removal from the oven. Insertions are normally carried out within a 6-7 second transfer time. Can Thermafil be used in curved canals? Yes. The plastic carrier is inherently flexible, eliminating the need to pre-curve it. The use of Thermafil is not restricted by canal size or shape. How long before the gutta-percha sets once it is in the canal? The gutta-percha becomes progressively harder/firmer over a 2-4 minute period. (The larger the obturator the longer the setting time) Can the obturator be extended or retracted within minutes of filling the canal and not disturb the seal? It is possible to extend the obturator further as long as the guttapercha remains sufficiently plasticised. Retraction of the obturator is not recommended; void formation and/or seal disruption may occur. 9

Frequently sked uestions Thermafil What do I do if I have to retreat the canal? well condensed gutta-percha root canal filling can be difficult to remove irregardless of technique. Clinical studies have shown that Thermafil is no more difficult to remove than gutta-percha obturated by lateral condensation. To remove Thermafil, initially soften the gutta-percha with chloroform and then position 1 or 2 Hedstroem files beside the carrier. Using the retreatment groove uniquely incorporated into the plastic carrier will then facilitate the removal of the remaining Thermafil. Use of rotary files (e.g. ProTaper) at higher RPMs than usual or ultrasonics (e.g. ProUltra) will quickly remove the Thermafil in cases where removal by softening is difficult. Retreatment 10 I ve had a patient experience post-op pain when I ve used Thermafil to obturate the canal. What is causing this? Obturations with Thermafil experience no more post-op pain than any other methods. The most frequent causes of this transient pain are overinstrumentation, expulsion of irrigating fluids past the apical constriction and into the periapical tissues, unrelieved excessive occlusal forces, and extrusion of sealer and/or filling materials into the periapical tissues. Pain that persists beyond this point may be due to an existing periapical infection, an unfilled canal that was inadvertently overlooked, a root fracture, inadequate root canal cleansing, a leaking temporary filling or another inflamed tooth. Because Thermafil so completely obturates the root canal system and can push unremoved canal contents through to the periapex, this technique is not forgiving of incompletely cleansed, debrided, and dried canals.

Frequently sked uestions Thermafil Will I get voids in the gutta-percha? You may notice tiny voids in the coronal one-third of the canal. These result from air as it is displaced by the apically moving gutta-percha, causing it to backflow coronally. Vertical compaction of the coronal gutta-percha can alleviate these voids. The N o 1/1 groove in the plastic carrier also helps reduce N this problem. n occasional, uncommonly large o 1/2 N canal, or one with internal resorption or a large o 2/3 flare, may require additional portions of softened N o 2/4 gutta-percha to complete the obturation. Use appropriate size pluggers for additonal vertical condensation of coronal gutta-percha When cutting off the top portion of the carrier, will the vibrations from the bur affect the seal? To avoid this, stabilise and secure the obturator by applying finger pressure to the handle while severing the shaft with a Prepi or round bur in a high-speed handpiece. What if I have to place a post? Timing of post space is operator preference, but there is no reason that post space cannot be prepared at the time of Thermafil obturation. There are several ways of doing this including using a Gates-Glidden bur (you will find that you will have to lean on it a little more than usual), a Peeso drill or a combination of both. Post drills with non-cutting tips are of no use. We recommend the Pro-Post system which is the only post system that offers a unique acid-etched surface to enhance retention. The Pro-Post drill tip is designed to be eccentric; that is, off the geometric centre. This allows the drill to stay centred as it rotates - forming a precise post hole diameter. The Pro-Post drill is extremely efficient for creating post space in canals obturated with Thermafil plastic carriers. The Post- Space bur is another alternative. 0.5mm 0.6mm 0.8mm 1.0mm Post-Space Bur Prepi Bur in Pro-Post System 11

Ordering Information THERMFIL Thermafil Int ro Kit with Case 016922012000X Thermaprep Plus Oven Posterior ssorted Thermafil (4 x 20, 4 x 25, 4 x 30, 4 x 35, 4 x 40) nterior ssorted Thermafil (3 x 45, 3 x 50, 3 x 55, 3 x 60, 3 x 70, 2 x 80, 2 x 90, 1 x 100) Verifiers ssorted 20-45, Verifiers ssorted 50-90 H Plus 5 Endo Training Blocks Maillefer Thermafil Video Thermap rep Plus Oven Kit 17622000200 Thermaprep Plus Oven Posterior ssorted Thermafil (4 x 20, 4 x 25, 4 x 30, 4 x 35, 4 x 40) Verifiers ssorted 20-45 016602502000 016602514000 034802502000 034802504000 016700090000 Thermafil Individual Packs of 6 ll 25mm Sizes vailable: 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80, 90, 100, 110, 120, 130, 140 Thermafil - Individual Packs of 30 ll 25mm Sizes vailable: 20, 25, 30, 35, 40 Posterior ssorted Thermafil (4 x 20, 4 x 25, 4 x 30, 4 x 35, 4 x 40) 016800090000 017502502000 017502509000 017502590000 017502590100 01740000 0100 nterior ssorted Thermafil (3 x 45, 3 x 50, 3 x 55, 3 x 60, 3 x 70, 2 x 80, 2 x 90, 1 x 100) Verifiers 25mm Individual Packs of 6 Sizes vailable: 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80, 90 Verifiers 25mm ssorted Packs of 6 20 45 Verifiers 25mm ssorted Packs of 6 50 90 Thermafil training blocks (12) #30.04 12 DENTSPLY (ustralia) Pty Ltd BN 15 004 290 322 11 21 Gilby Road, Mount Waverley VIC 3149 Tel: 1300 55 29 29 Fax: 1300 55 31 31 clientservices@dentsply.com www.dentsply.com.au DENTSPLY New Zealand 16 Morgan Street, Newmarket, uckland,1023 Tel: 0800 DENTSPLY (33 68 77) Fax: 0800 DENTFX (33 68 32) Email: clientservicesnz@dentsply.com Website: www.dentsply.co.nz 205/03/06