TYPE 1 Sound Meter. Instruction Manual

Similar documents
Light Meter (Foot Candles)

Microwave Meter. Instruction Manual

1. SAFETY INFORMATION

User's Guide. Digital Sound Level Meter. Model

SOUND LEVEL METER 94405

User's Guide. Integrating Sound Level Datalogger. Model Introduction

User's Guide Integrating Sound Level Datalogger Model

Integrating Sound Level Meter and Datalogger

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Distributed by TestEquity LLC

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

4-Channel Thermometer / Datalogger

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

DISSOLVED OXYGEN METER Model : DO-5509

2X1 DVI Switch (DS-21R) 4X1 DVI Switch (DS-41R) USER MANUAL. DTronics Inc.

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

BASIC SOUND LEVEL METERS

Benchtop Computer Monitor Generator

i410/i1010 AC/DC Current Clamp

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

FREQUENCY RESPONSE ANALYZERS

ASP-DTH. DVI & Audio to HDMI Converter. User Manual. Manual Number:

Contents. Safety Warnings... 1

Ultrasonic Distance Meter. Operation Manual

Ground Resistance Clamp-On Tester

Description. Dimensions. Features. precision works better

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

How To Use A Cdm250 Digital Multimeter

Thermistor Thermometer MODEL NO

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Multifunction Process Calibrator

Duct Humidity Transmitter

DAB+ / FM Tuner Model: TU-201

Model SRMD Setra Remote Monitoring Display

Extender for HDMI 1.3 over CAT6. GTV-HDMI1.3-CAT6 User Manual.

ExStik TM ph Waterproof Meters

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

SC-30 INTEGRATING SOUND LEVEL METER REAL TIME FREQUENCY ANALYZER

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER. Setting The Clinical Standard

Air Conduction Audiometer Series. MA 27 with headphones and built-in carrying case. MA1, MA25 & MA27.

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Optical Power Meter. Specification & User Manual

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Component With Audio. Model # COMP-2-HDMI-AD USER MANUAL.

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Ground Resistance Clamp On Tester

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

HDMI/DVI to VGA/Component & Audio Break out Converter

NoiseMeters. dosebadge. Monitoring Personal Noise Exposure

FREJA 300 Relay Testing System

Integrating Sound Level Meters LA-5570/5560/2560

SPIDER TM. User s Manual. 1:2 DVI Distribution Amplifier (OVD12) 1:5 DVI Distribution Amplifier (OVD15) Opticis Locations 1.

INSTRUCTION MANUAL DTH Fax: (503)

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

CT-001, CT-001-Solar Owner s Manual

USB Smart Power Sensor

700/732 SERIES. 5mm HOUR METERS & COUNTERS. CURTIS INSTRUMENTS, INC. 200 Kisco Avenue, Mt. Kisco, NY Tel. (914) FAX (914)

AutoRanging Digital MultiMeter

Owner s Manual channel amplifier

DVI+HDCP 4x1 Switcher User Manual

1. Introduction. 2. Components. 3. Optical Specifications. 4. Electric Specifications. 5. Dimension. 6. Operating Environment. 7.

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Milwaukee USER MANUAL

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

DWH-1B. with a security system that keeps you in touch with what matters most

instructions for Model 2800 Integrating Sound Level Meter and Model OB-100 Octave Band Filter Model OB-300 1/1-1/3 Octave Band Filter and

HCS-3600MB2 Conference Main Unit

Portable Bluetooth Speaker. Quick Start Guide. Model: BTS201

HDMI To Composite/S-Video Scaler. GTV-HDMI-2-COMPSVIDS User Manual.

Quick Connect. quick - simple - efficient.

USER MANUAL V5.0 ST100

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Operating Instructions MA 27

Physical Specifications (Custom design available.)

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

HC-HD1. HDMI to DVI Converter

Instruction Manual Temp 4/5/6 Temperature Meter Series

DTS/DRS-1000RV. Owner s Manual. DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender

DCS Series 1 kw, 1.2 kw, & 3 kw

Manual Ranging MultiMeter

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

ER102. Emergency Crank Weather Radio Owner s Manual.

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

EzFlex Combustible Gas Leak Detector Model EZ40

3-phase, bidirectional energy meter

Point of view HDMI Smart TV dongle Mini RF Keyboard

Energy Management Energy Meter Type EM23 DIN

323/324/325. Calibration Manual. Clamp Meter

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

Composite/S-Video to HDMI Video Converter with Audio

TWO/FIFTY/TWO STEREO POWER AMPLIFIER

Transcription:

TYPE 1 Sound Meter 840015 Instruction Manual

CONTENTS 1. Introduction... 3 2. Panel Description... 3 3. Operating Instructions... 4 3-A. Measuring Procedure 3-B. General Applications Settings 3-C. Signal Output 3-D. Precautions 4. Calibration... 5 5. Battery Replacement... 5 6. Frequency Weighting (A and C) Characteristics... 6 7. Time Weighting (Fast and Slow) Characteristics... 6 8. Specifications... 7 9. Warranty... 8 2

1. INTRODUCTION Your new instrument meets IEC61672 and ANSI S1.43 specifications for a Type 1 Sound Meter. It covers the 30 ~ 130 db range in both the A and C decibel frequency weighting scales, with 0.1 db resolution and an accuracy of ±1 db (63 Hz ~ 4 khz). This meter can be acoustically calibrated in compliance with OSHA, using Sper Scientific s Acoustical Calibrator 850016 (or equivalent). Features include a built-in calibration adjustment, easy to read LCD display, fast or slow time weightings, maximum hold function, low battery indicator, AC output and a reset button. CE compliant. Accessories include a windscreen, calibration tool, a carrying case, instruction manual and batteries. 2. PANEL DESCRIPTION 1. Microphone 2. Threaded Microphone Cap 3. Overload indicator 1 2 4. Display 5. Range selector 6. Power/Calibration selector 7. Time Weighting selector 8. Max Hold/Instant selector 9. Calibration Adjustment 10. Reset button 11. Frequency Weighting selector 12. Signal Output Terminal 3 4 5 6 7 8 9 10 11 12 3

3. OPERATING INSTRUCTIONS 3-A. Measurement Procedures Slide the POWER (6) selector to the "I" (on) position. For general applications, slide the MAX HOLD / INSTANT (8) selector to the INSTANT position. To freeze the displayed reading, slide the MAX HOLD / INSTANT (8) selector to the MAX HOLD position. Press the RESET (10) button once to reset maximum hold to the current reading. Slide the FREQUENCY WEIGHTING (11) selector to the "A" or "C" position. The "A" frequency weighting simulates human ear response. During an environmental sound level measurement, select the "A" weighting. The "C" weighting approximates a flat response. Typically, "C" is used to check the noise of machinery where the target sound level is already known. (See Frequency Weighting Characteristics, page 6.) Slide the TIME WEIGHTING (7) selector to the "F" (fast) or "S" (slow) position. For general applications, select "F" which simulates the human ear's response time. The "S" setting is used to obtain an average of vibrating sound levels. Find the appropriate measuring range using the RANGE (5) selector. If the OVERLOAD INDICATOR (3) appears in the upper-left display, slide the RANGE (5) selector to another setting. Point the microphone at the sound source. The sound level will be displayed in decibels (db). When finished, slide the POWER (6) selector to the "O" (off) position. 3-B. General Application Settings Set POWER / CALIBRATION (6) selector to "I" (on). Set TIME WEIGHTING (7) to "F". Set MAX HOLD / INSTANT (8) selector to INSTANT. Set FREQUENCY WEIGHTING (11) to "A". Set RANGE (5) selector to the appropriate range. 3-C. Signal Output The 3.5 mm diameter SIGNAL OUTPUT (12) terminal may be used to connect the unit to an external device (analyzer, recorder, controller, etc). 3-D. Precautions Do not store or operate the unit in high temperatures or in a high humidity environment for long periods. Keep the microphone dry and avoid intense vibrations. 4

4. CALIBRATION The meter's CALIBRATION ADJUSTMENT (9) is located on the front panel. The meter has a built-in internal standard of 94 db/1 KHz. Use the following procedures to calibrate the instrument before operating for the first time, or when the meter has not been in use for awhile. Internal Calibration: Slide the POWER (6) selector to the CAL. Position. Slide the RANGE (5) selector to the 60 ~ 100 db position. Slide the TIME WEIGHTING (7) selector to "F". Slide the FREQUENCY WEIGHTING (11) selector to "A". Use the calibration screw driver to turn the CALIBRATION ADJUSTMENT (9) until the display reads 94.0. External Calibration: Use Sper Scientifics' Acoustical Calibrator 850016 (or equivalent) to calibrate the unit, including the microphone, in compliance with OSHA. Slide POWER (6) selector to the "I" (on). Turn on the acoustical calibrator and place it onto the Sound Level Meter's MICROPHONE (1). Slide the RANGE (5) selector to the 60 ~ 100 db position. Slide the TIME WEIGHTING (7) selector to "F". Slide the FREQUENCY WEIGHTING (11) selector to "A". Use the calibration screw driver to turn the CALIBRATION ADJUSTMENT (9) until the display reads 94.0. 5. BATTERY REPLACEMENT Replace the batteries when "BAT" is displayed. Accurate measurements may be made for several hours after the low battery indicator appears. Replace the batteries with 2 new heavy duty 9V batteries. 5

6. FREQUENCY WEIGHTING (A and C) CHARACTERISTICS Frequency A Weighting C Weighting Tolerance (IEC 61672 Class 1) 31.5 Hz -39.4 db -3 db ± 2.0 db 63 Hz -26.2 db -0.8 db ± 1.5 db 125 Hz -16.1 db -0.2 db ± 1.5 db 250 Hz -8.6 db 0 db ± 1.4 db 500 Hz -3.2 db 0 db ± 1.4 db 1 khz 0 db 0 db ± 1.1 db 2 khz +1.2 db -0.2 db ± 1.6 db 4 khz +1 db -0.8 db ± 1.6 db Tolerance (ANSI S1.43 Type 1) ± 1.5 db 8 khz -1.1 db -3 db 12.5 khz -4.3 db -6.2 db 16 khz -6.6 db -8.5 db +2.1 db -3.1 db +3.0 db -6.0 db +3.5 db -17.0 db +1.5 db -6.0 db +3.0 db -6.0 db +3.0 db -no limit 7. TIME WEIGHTING (Fast and Slow) CHARACTERISTICS Time Weighting Max. response ref. continuous signal Tolerance (IEC 61672 Type 1) F (Fast) -1.0 db + 1.0 db S (Slow) -4.1 db ± 1.0 db Tested with signal on 1000 Hz/94 db. 6

8. SPECIFICATIONS Display Function Measurement Range Resolution Accuracy (23 ± 5 ) Frequency Microphone Time weighting (Fast/Slow) Internal Calibration Output Signal Output Terminal Operating Environment. Power Supply Power Consumption Weight Dimension Optional Accessories 18 mm (.0.7") LCD 3¼ digits db ( A and C Frequency weighting), Time weighting (Fast, Slow), Max. hold, AC Output 30-70 db, 60-100 db, and 90-130 db 40 db on each step, with overload indicator 0.1 db Frequency weighting meets ANSI S1.43 calibration input signal on 94 db 31.5 Hz ~ 8 khz), then the accuracy of "A" weighting is specified as: 31.5 Hz - ± 1.5 db, 63 Hz - ± 1 db 125 Hz - ± 1 db, 250 Hz - ± 1 db 500 Hz - ± 1 db, 06 khz - ± 1 db 2 khz - ± 1 db, 4 khz - ± 1 db 8 khz - + 1.5 db to - 3 db 12.5 khz - + 3dB to - 6dB 16 khz - + 3dB to - No Limit 31.5 Hz to 16 khz 1/2" standard size electric condenser microphone. Threaded microphone cap unscrews for microphone replacement. Fast (F): t = 125 ms Slow (S): t = 1000 ms Built-in internal calibration on front panel. Calibrated via internal 94 db/1khz square wave generator AC 750 mvrms corresponding to each range step 3.5 mm diameter jack 0 ~ 50 C (32 ~ 122 F) and less than 80% RH DC 9V battery x 2PCs, 0006P, MN1604 (PP3) or equivalent, heavy duty or alkaline type Approximately DC 17mA 1 lb (460g) with battery 10½ x 3½ x 1½" (260 x 87 x 36 mm) 840091 Wind Screen Replacement 840092 Bench-Top Tripod 840093 Field 7 Tripod 850016 Acoustical Calibrator

9. WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of five (5) years from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover probes, batteries or damage resulting from accident, misuse, or abuse of the product. In order to obtain warranty service, ship the unit postage prepaid to: SPER SCIENTIFIC LTD. 7720 East Redfield, Suite 7 Scottsdale, Arizona 85260 (480) 948-4448 The defective unit must be accompanied by a description of the problem and your return address. Register online at www.sperscientific.com or return your warranty registration card within ten (10) days of purchase. Rev. 1/09/12 8