L Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity

Similar documents
Technical data sheet TDS0070

Duct Humidity Transmitter

Capteur température et humidité pour HVAC

ATL Fuel Level Sender Probes

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC

T0118 T2118 T3118. Instruction Manual

Description. Dimensions. Features. precision works better

Digital inductive conductivity transmitter

GREISINGER electronic GmbH

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Digital display DA 48

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Incubator with mechanical convection

Mounting Instructions. Torque Transducer. A en

USER'S GUIDE. Vaisala HUMICAP Humidity Transmitter Series HMP140A U175EN15

Digital input modules

DUST EMISSION MONITORING SYSTEM

Material test chamber with mechanical convection

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

How To Read A Pipe From A Sensor

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Instructions for assembly and use MULTICAL 601

How To Power A Schen

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Pressure Dew Point Probe / Application Information

Instruction Manual Differential Pressure Transmitter

testo 6721 Dew point monitor P2A software for testo 6721 Instruction manual

Instruction Manual. T3111 T3111L T3111P T3111Ex

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Pressure transmitter For general industrial applications Model A-10

Wind Sensor W-RS485 with RS485 Interface

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 4 v2.2 / Modification rights reserved EE210

SINEAX U553 Transducer for AC Voltage

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Climate chamber with illumination

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Radiant Temperature Sensor TY7321

Conductive Level Switch FK 2 Technical Data:

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Dissolved Oxygen Sensors

Heating oven with mechanical convection

Series 7500 Torque Sensor

Rotary actuators Rotary wing drives Series RAK. Brochure

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide

ACS-30-EU-EMDR-10-MOD

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Cable Plug acc. to DIN EN , Form A

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

INFRARED QUARTZ WALL HEATER

Givare NC-SRS 280 och 880

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Technical Data. Dimensions

Adjustment functions for both span and shift have been incorporated

MLC TM Maximum Productivity and Versatility for Control without Compromise!

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Electronic Control Devices The European Product Catalogue 2007

Contents. Document information

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

Features. Picture. Specifications

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Processor. Installation Guide

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Vacuum drying oven for non-flammable solvents

Hydraulic Control Solutions

Transcription:

Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH Boschstr. 4 Raasdorfer Str. 18 71145 Bondorf. Germany 07987 Mohlsdorf-Teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0 Tel. +49(0)3661-62704-0 Fax +49 (0)7457-3758 Fax +49(0)3661-62704-20 E-Mail: sensoren@galltec.de E-mail:mela@melasensor.de Humidity/-temperature sensors for use in heating, ventilation and air conditioning LK LP LI LW Four designs duct version (LK) wall mounting (LW) rod-shaped Ø 12mm (LP) room version (LI) Different physical outputs Output signals Special versions humidity and temp., 2 x active humidity active / temp. passive humidity only, active temperature only, active or passive 0...1 V 0...5 V 0...10 V passive (temperature) sealing for increased requirements, e.g. condensation sealing against vibrations Technical data Humidity sensing element calibrated sensor chip calht output range 0...100 %rh accuracy 30...80 %rh at 10...40 C ±3 %rh < 30 %rh or > 80 %rh at 10...40 C ±5 %rh influence of temperature < 10 C or > 40 C typ. ±0.06 %rh/k Filter protective basket ZE07 (IP 00) filter with membrane ZE08 (IP30) PTFE sintered filter ZE05 (IP65) Rod-shaped sensor with 2 types of connection 6-pin plug-in connection and assembled cable permanently attached cable Temperature / active output sensing element output ranges accuracy at 10...40 C <10 C and >40 C calibrated sensor chip calht 0...+50 C -20...+80 C -30...+70 C 0...+100 C ±0.8 K s. diagramm on page 2 page 1 of 8

Temperature / passive output sensing elements other sensing elements on demand Electrical data outputs Voltage supply LP, LK, LW, LI output: 0...1V 0...5V LK, LW, LI output: 0...10 V 2 x 0...1 V 2 x 0...5 V 2 x 0...10 V passive temperature outputs on demand 6...30 V DC 24 V AC ± 10% or 9...30 V DC 0...10 V 12...30 V DC load resistance for voltage output 0...1 V voltage output 0...5 V voltage output 0...10 V Pt100 Pt1000 e. g. NTC 24 V AC ± 10% or 13...30 V DC > 1 kohm > 10 kohm > 10 kohm electromagnetic compatibility ref. EN 61326 General data measuring medium min. air speed operating temperature type LP, LK, LW type LI storage temperature air, pressureless, non-aggressive, non-condensing 0.5 m/s -30...+80 C -20...+60 C -40...+85 C degree of protection of measuring head (series LK, LW, LI) with protective basket ZE07 with membrane filter ZE08 with PTFE sintered filter ZE05 degree of protection of housing type LP, LK, LW type LI material of housing type LP, LK, LW type LI IP00 IP30 IP65 IP65 IP30 PC (light grey / white) ABS (white) Temperature accuracy Working range of humidity and temperature % r.h. 100% 80% 60% 40% 20% recommended working range Operating the sensor in these areas can damage it! 0% -40 C 0 C 40 C 80 C Accessories Designation Order reference Info sheet Description ZE36 ZE36 F5.2 ZE 31/1 ZE 31/1-12 + ZE36 ZE 31/1-33 + ZE36 ZE 31/1-75 + ZE36 ZE 31/1-84 + ZE36 ZE 31/1-97 + ZE36 F5.2 adapter required for sensor tubes Ø 12mm for humidity standard ZE 31/1 and wall console 20.009 humidity standard 12 %rh and 25 C 33 %rh and 25 C 75 %rh and 25 C 84 %rh and 25 C 97 %rh and 25 C Wall console 20.009 + ZE36 F5.1 wall console for wall-mounting of rod shaped- and duct sensors Flange 20.045 fixing flange for sensor tubes Ø 12mm with rubber sealing Cable LPx2.02 LPF2.02.67-xx.x LPK2.02.67-xx.x LPC2.02.67-xx.x cable, with 6-pin coupling for rod shaped sensor LP with plug-in connection unshielded, IP67, up to max. 10 m (xx.x = length in m, e.g. 01.5 = 1.5 m) for humidity sensor LPF2 for humidity/-temperature sensor LPK for humidity sensor with passive temperature output LPC page 2 of 8

Product Key The 16 character alphanumeric order number for the desired type is composed of the order code listed below, 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Series Design Physical outputs Output signals Operating conditions / Special versions Measured variable and output range 1 Measured variable and output range 2 Operating voltage Measuring head / Filter / Diameter Design description Technical Data Options Order Code 1 Series L 2 Design Duct version K Wall mounting W Rod shaped, plastic, Ø 12mm P Room version I 3 Physical outputs Humidity and temperature, 2 x active K Humidity active / temperature passive C humidity only, active F Temperature only, active or passive T 4 Output signals 1x 0...1V or 2x 0...1V or 1x 0...1V/1x passive 1 1x 0...5V or 2x 0...5V or 1x 0...5V/1x passive 8 1x 0...10V or 2x 0...10V or 1x 0...10V/1x passive 2 Temperature passive, only 5 5 6 Operation conditions / special versions Standard 00 Sealing against vibrations (optional for types LK, LW, LP) Sealing for increased requirements (e.g. condensation) (optional for types LK, LW, LP) 0V 0S 7 8 Measured variable and output range 1 None / no humidity measurement 00 Relative Humidity 0...100 % rh F1 page 3 of 8

Technical Data Options Order Code 9 10 Measured variable and output range 2 None / no temperature measurement 00 Temperature 0... 50 C 05 Temperature 0... 100 C 01 Temperature -20... 80 C 28 Temperature -30... 70 C 37 Temperature passive Pt100 cl. B C1 Temperature passive Pt1000 C5 Further output ranges on demand 11 Operation voltage Series LP, LK, LW, LI with 0...1V output: 6... 30 V DC 6 Series LP, LK, LW, LI with 0...5V output: 24 V AC ± 10% or 9... 30 V 9 Series LP, LK, LW, LI with 0...10V output: 12... 30 V DC C Series LK, LW, LI with 0...10V output: 24 V AC ± 10% or 13... 30 V DC E Temperature sensors with passive output signal 0 12 13 Measuring head / Filter / Diameter ZE07: protective cage, plastic, open, Ø 12 mm 07 ZE08: protective cage, plastic, with membrane, Ø 12 mm 08 ZE05: PTFE sintered filter, Ø 12 mm 05 14 15 16 Description of design Rod shaped sensor, 6-pin plug-in connection Sensor tube length, incl. plug = 101 mm Rod shaped sensor, with permanently attached cable, 1.5 m, Sensor tube length = 95 mm special lengths for rod shaped sensors (up to max. 5 m) 6S 4 1K 4 xx 4 e.g. 2.0 m 2.5 m 3.0 m 3.5 m Duct sensor, sensor tube length 220 mm (standard) 02 4 2K 4 03 4 3K 4 00 G Wall mounting, sensor tube length 50 mm (standard) 00 1 Room sensor 00 0 Ordering Example Series: Design: Rod shaped Physical outputs: 2 active outputs Output signals: 2 x 0...10 V Operation conditions / special versions: Sealing against vibrations Measured variable and output range 1: 0...100% rh Measured variable and output range 2: -30...70 C Operating voltage: 12...30 V DC Measuring head / Filter / Diameter: PTFE sintered filter ZE05 / 12 mm Description of design with permanently attached cable, 1.5 m Sensor tube length = 95 mm L P K 2 0V F1 37 C 05 1K 4 page 4 of 8

Dimensional drawing rod-shaped sensor LP with permanently attached cable 33 95 12 Configuration of series LP with permanently attached cable Humidity 0...1/5/10 V conductor colour connection supply brown GND + UB humidity white 0...1/5/10 V Humidity and temperature active 0...1/5/10V conductor colour connection supply brown GND + UB humidity white 0...1/5/10 V temperature yellow 0...1/5/10 V Humidity 0...1/5/10 V temperature passive, 4-wire conductor colour supply brown GND connection + UB humidity white 0...1/5/10 V temperature blue T1 temperature yellow T1 temperature pink T2 temperature grey T2 Dimensional drawing rod-shaped sensor LP with plug-in connection and additional cable voltage output and / or temperature passive, 3-wire Dimensional drawing cable LPx2.02.67... 12 33 93,5 101 Pin assignment of accessory cable LPK2.02.67... (2x 0...1/5/10 V) Pin assignment of accessory cable LPF2.02.67... (0...1/5/10 V) white yellow brown white brown Pin assignment of accessory cable LPC2.02.67... (0...1/5/10 V and temperature passive, 3-wire) pink grey white yellow brown page 5 of 8

Dimensional drawing series LK Dimensional drawing series LW 12 83 220 1 15 18 1 15 40 40 26 57 41,5 83 83 12 57 50 Dimensional drawing series LI 1 11 81 25,7 47,5 10,5 81

Pin assignment of series LK, LW, LI Voltage output Voltage output Temperature 4-wire Connection between supply ground and measuring ground is not recommended for 24V AC. V-/GND terminals are internally connected Connection between supply ground and measuring ground is not recommended for 24V AC. V-/GND terminals are internally connected Pin assignment of series LK, LW, LI Temperature 4-wire Connection between supply ground and measuring ground is not recommended for 24V AC. V-/GND terminals are internally connected Connection between supply ground and measuring ground is not recommended for 24V AC. V-/GND terminals are internally connected ESD protection advice The sensors of the contain components, which can be damaged by the effects of electrical fields or by charge equalisation when touched. The following protective measures must be taken when the housing of the sensor is to be opened for connection: Before opening the housing of the sensor, ensure electrical potential equalisation between you and your environment. Pay particular attention to ensure that this potential equalisation is maintained while you are working with the opened housing. page 7 of 8

Mounting instructions Position Fixing flange Connection Install the sensor at a place where characteristic levels of humidity occur. The sensor tube resp. measuring head or measuring chamber should be exposed to the flow of air. Avoid installation next to heaters, doors or on outer walls. Avoid places exposed to the sun. The sensors for wall mounting (series LW) and the room versions (series LI) can be mounted on a patress or directly on the wall. It is important that the surface is even. When mounting the sensors on a patress, avoid external air getting onto the humidity measuring element of the sensor by sealing it appropriately. The sensor should be mounted in such a way that no water can get into it. To close the housing the screw is tightened until it stops. We recommend that you lay the connection lines in a loop so that any water that may be present can run off. For mounting the fixing flange (for duct mounting of series LK/LP), a hole pattern is printed on the packaging. To fix the sensor, simply open the opening tab of the flange by finger pressure or with the help of a pair of pliars. The sensor can be fixed in the flange at any position. The electrical connection must be carried out by qualified personnel only. Lines to and from the sensor must not be installed parallel to strong electromagnetical fields. In the case of a possible overvoltage please install surge protection devices. User instructions Dew formation Contaminated filters Cleaning of PTFE sintered filter ZE05 and protective basket ZE07 Cleaning of sensor chip Damaging influences Dew formation and splashes do not damage the sensor, although measurement readings are corrupted until all moisture on and around the sensing element has dried up completely. If the PTFE sintered filter ZE05 and the membrane filter ZE08 is contaminated with dust, grease and oils, this can have a negative impact on the dynamic behaviour of the sensor. If necessary, soiled filters and protective baskets can be screwed off and rinsed carefully. Bear in mind the sensors wil not measure accurately until filters are completely dry. Please do not touch the highly sensitive sensing element. Loose dust can be carefully cleaned off the humidity sensing element using distilled water or by blowing the dust carefully off. Please do not touch the highly sensitive humidity sensing element Depending on type and concentration, agents that are corrosive and contain solvents, can result in faulty measurements and can cause the sensor to break down. Substances deposited on the sensor (e. g. resin aerosols, lacuer aerosols, smoke deposits etc.) are damaging as they eventually form a water-repellent film. This information is based on current knowledge and is intended to provide details of our products and their possible applications. It does not, therefore, act as a guarantee of specific properties of the products described or of their suitability for a particular application. It is our experience that the equipment may be used across a broad spectrum of applications under the most varied conditions and loads. We cannot appraise every individual case. Purchasers and/or users are responsible for checking the equipment for suitability for any particular application. Any existing industrial rights of protection must be observed. The quality of our products is guaranteed under our General Conditions of Sale. Data sheet L -Serie_EN. Issue: May 2013. Subject to modifications. page 8 of 8