DEVELOPMENT OF A BIOFIDELIC PEDESTRIAN LEGFORM IMPACTOR - INTRODUCTION OF JAMA-JARI LEGFORM IMPACTOR Ver

Similar documents
FIRST RESULTS FROM THE JAMA HUMAN BODY MODEL PROJECT

PEDESTRIAN HEAD IMPACT ANALYSIS

Impact Kinematics of Cyclist and Head Injury Mechanism in Car to Bicycle Collision

Pedestrian protection - Pedestrian in collision with personal car

EFFECT OF MUSCLE CONTRACTION IN LOW SPEED CAR-PEDESTRIAN IMPACT SIMULATIONS FOR WALKING POSTURE

Thoracic Injury Criterion for Frontal Crash Applicable to All Restraint Systems

Proposal for Amendment [3] to global technical regulation No. 9 (Pedestrian safety)

Consideration on ACL/PCL Failure Evaluation

CURVE is the Institutional Repository for Coventry University

Keywords : Pedestrian Impactor Models, Pedestrian Protection Simulation, LS-DYNA

Introduction to Mechanical Behavior of Biological Materials

BioRID II Dummy Model Development -- Influence of Parameters in Validation and Consumer Tests

Load and Impact Conditions for Head Injuries in Car-to-Pedestrian and Car-to-Cyclist Accidents A Comparison of Real Accidents and Simulations

DEVELOPMENT OF MOVING DEFORMABLE BARRIER IN JAPAN - PART 2 -

PREDICTING THROW DISTANCE VARIATIONS IN BICYCLE CRASHES

FE SIMULATIONS OF MOTORCYCLE CAR FRONTAL CRASHES, VALIDATION AND OBSERVATIONS

EFFECT OF VEHICLE DESIGN ON HEAD INJURY SEVERITY AND THROW DISTANCE VARIATIONS IN BICYCLE CRASHES

COMPARISON OF BIORID INJURY CRITERIA BETWEEN DYNAMIC SLED TESTS AND VEHICLE CRASH TESTS

Predicting throw distance variations in bicycle crashes

On Predicting Lower Leg Injuries. for the EuroNCAP Front Crash

ENHANCEMENT OF SEAT PERFORMANCE IN LOW-SPEED REAR IMPACT

European New Car Assessment Program (EuroNCAP) and Crash Test Ratings of New Vehicles

Biomechanics of the Neck in Rear Impacts for improved Seat Design

A multi-body head and neck model for low speed rear impact analysis

Cyclist kinematics in car impacts reconstructed in simulations and full scale testing with Polar dummy

Proposing a 2D Dynamical Model for Investigating the parameters Affecting Whiplash Injuries

In-situ Load Testing to Evaluate New Repair Techniques

LATIN AMERICAN & CARRIBEAN NEW CAR ASSESSMENT PROGRAMME (Latin NCAP) ASSESSMENT PROTOCOL ADULT OCCUPANT PROTECTION 2016

Summary Report: Requirements and Assessment of Low-Speed Rear Impact Whiplash Dummies

A NEW TEST METHOD FOR THE ASSESSMENT OF NECK INJURIES IN REAR-END COLLISIONS

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

US FMVSS 202 Final Rule

ANALYTICAL AND EXPERIMENTAL EVALUATION OF SPRING BACK EFFECTS IN A TYPICAL COLD ROLLED SHEET

SIMULATION OF PEDESTRIAN SAFETY FOR AMG C63 USING ANSA & ΜETA. KEYWORDS pedestrian safety, pre processing, post processing, automization, regulation

Safety performance comparisons of different types of child seats in high speed impact tests

Estimation of Work Hardening in Bent Sheet Metal Products at an Early Stage of Virtual Product Development

NCAP New Car Assessment Programme

INTERACTION BETWEEN MOVING VEHICLES AND RAILWAY TRACK AT HIGH SPEED

Structural Axial, Shear and Bending Moments

CRANFIELD UNIVERSITY J. W. WATSON. Experimentation and Simulation. School of Applied Science. PhD

A Systematic Approach for Improving Occupant Protection in Rollover Crashes

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1

Structural Bonding for Lightweight Construction

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

Equivalent Spring Stiffness

WHIPLASH INJURIES, NOT ONLY A PROBLEM IN REAR-END IMPACT

High-Speed Demonstration of Natural Laminar Flow Wing & Load Control for Future Regional Aircraft through innovative Wind Tunnel Model

Factors related to serious injury in post ncap european cars involved in frontal crashes

Head injury prediction tool for protective systems optimisation

Influence of Crash Box on Automotive Crashworthiness

JASIC Result of drawing review (surface level) GTR9-7-05c

Version default Titre : SSNP161 Essais biaxiaux de Kupfer Date : 10/10/2012 Page : 1/8 Responsable : François HAMON Clé : V Révision : 9783

DUCTILE DAMAGE PARAMETERS IDENTIFICATION FOR NUCLEAR POWER PLANTS EXPERIMENTAL PART. Antonín PRANTL, Jan DŽUGAN, Pavel KONOPÍK

DEVELOPMENT AND APPLICATIONS OF TUNED/HYBRID MASS DAMPERS USING MULTI-STAGE RUBBER BEARINGS FOR VIBRATION CONTROL OF STRUCTURES

Influence of the front part of the vehicle and cyclist s sitting position on the severity of head injury in side collision

DOCUMENT RETRIEVAL INFORMATION

A New Impact Scenario for P-V Tram Certification

8.2 Elastic Strain Energy

INTRODUCTION. ICrash 2006, Athens Greece, 4th-7th July 2006

AUTORIZOVANÝ SOFTWARE PED2D SOFTWARE FOR 2D CAR TO PEDESTRIAN FRONTAL IMPACT ANALYSIS

SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS

Optimum proportions for the design of suspension bridge

Deflections. Question: What are Structural Deflections?

Introduction to Solid Modeling Using SolidWorks 2012 SolidWorks Simulation Tutorial Page 1

3. Test Methods for Evaluation of ESCR of Plastics

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Abaqus Technology Brief. Automobile Roof Crush Analysis with Abaqus

Nonlinear analysis and form-finding in GSA Training Course

2.0 External and Internal Forces act on structures

Stresses in Beam (Basic Topics)

Handheld Shock Control Design Guide

Pedestrian and Cyclist Impact

MECHANICS OF MATERIALS

Rear Impact Dummy Biofidelity

Development of a Dropped Weight Impact Testing Machine

Crash Analysis of Car Cross Member Bumper Beam

Finite Element Modelling of Biomechanical Dummies- The Ultimate Tool in Anti-Whiplash Safety Design?

Classification of Crash Pattern Based on Vehicle Acceleration and Prediction Algorithm for Occupant Injury

BOLTED RHS END-PLATE JOINTS IN AXIAL TENSION

The elements used in commercial codes can be classified in two basic categories:

ARP5765 : Analytical Methods for Aircraft Seat Design and Evaluation Prasanna Bhonge, PhD Cessna Aircraft Company Wichita, KS 7 August 2012

Material Optimization and Weight Reduction of Drive Shaft Using Composite Material

Safe handling when securing loads on trucks

Parachute Jumping, Falling, and Landing David C. Arney, Barbra S. Melendez, Debra Schnelle 1

CLASSIFICATION BOUNDARIES FOR STIFFNESS OF BEAM-TO- COLUMN JOINTS AND COLUMN BASES

The Development of Virtual Testing Model for Korea High Speed Train

Comparison of the Humboldt GeoGauge With In-Place Quasi-Static Plate Load Tests. Charles R. Nelson, P.E. Mike Sondag

INTRODUCTION Cerclage Cable Vs. Monofilament Wire

The Pipe/Soil Structure Actions and Interactions

WHIPLASH. July Adapted from BP digital services presentation. S. Petmecky

Fluid Mechanics: Static s Kinematics Dynamics Fluid

ABSTRACT INJURY CRITERION TO ASSESS WHIPLASH INJURY IN FMVSS NO. 202 DYNAMIC TEST OPTION

EFFECTS OF SALT WATER AGING ON THE POST- IMPACT BEHAVIOR OF POLYMERIC COMPOSITES

Mechanism of Injury 1

INVESTIGATION OF LOWER SPINE COMPRESSION FRACTURES IN FRONTAL CRASHES

The Petrylaw Lawsuits Settlements and Injury Settlement Report

A NEW DESIGN METHOD FOR INDUSTRIAL PORTAL FRAMES IN FIRE

FXA UNIT G484 Module Simple Harmonic Oscillations 11. frequency of the applied = natural frequency of the

Chapter 3 Non-parametric Models for Magneto-Rheological Dampers

Transcription:

DEVELOPMENT OF A BIOFIDELIC PEDESTRIAN LEGFORM IMPACTOR - INTRODUCTION OF JAMA-JARI LEGFORM IMPACTOR Ver. 22 - Atsuhiro Konosu Japan Automobile Research Institute Masaaki Tanahashi Japan Automobile Manufacturers Association, Inc. Paper Number 378 ABSTRACT The Japan Automobile Manufacturers Association, Inc., (JAMA) and the Japan Automobile Research Institute (JARI) are collaborating to develop a biofidelic pedestrian legform impactor because the current major pedestrian legform impactor, the Transport Research Laboratory (TRL) legform impactor, lacks biofidelity. JAMA and JARI have been developing a biofidelic legform impactor since 2. This report introduces the JAMA-JARI legform impactor ver. 22. This version has two major improvements: it properly simulates human bone flexibility and human knee joint characteristics. The above improvements are quite important for ensuring biofidelity of the legform impactor. INTRODUCTION In 1994, the European Experimental Vehicles Committee Working Group 1 (EEVC/WG1) proposed a pedestrian legform impactor [1]. The impactor was proposed to assess the car-induced damage to a pedestrian leg in car-to-pedestrian impacts. However, the developed legform impactor, the Transport Research Laboratory (TRL) legform impactor, does not simulate human bone flexibility and its knee joint is composed of a steel bending plate. These characteristics are quite different from human characteristics. EEVC/WG17 modified the TRL impactor but just added a damper to reduce the impactor knee shearing vibration [2]. The TRL legform impactor s lack of the biofidelity caused the leg response to differ from that of a human leg [3][4][5]. Trials were proposed to obtain a transfer function between the TRL legform impactor and the human leg [4][5]. However, the transfer function may not apply to all impact situations, especially for different bumper heights. The Japan Automobile Manufacturers Association, Inc., (JAMA) and the Japan Automobile Research Institute (JARI) decided to develop a more biofidelic legform impactor that does not need a transfer function and can be used for most pedestrian leg impact situations. This report introduces the latest JAMA-JARI developed legform impactor and shows its validation test results. SPECIFICATIONS OF THE JAMA-JARI BIOFIDELIC LEGFORM IMPACTOR The first version of the JAMA-JARI legform impactor was developed in 2 (JAMA-JARI legform impactor ver. 2) [6]. The first model introduced a knee ligament restraint system using the Polar pedestrian dummy knee ligament system. It's response was more biofidelic than that of the TRL legform impactor, but its bone part was still rigid so the impact energy tended to concentrate in the knee joint. In 22, JAMA and JARI developed a new legform impactor that had the knee ligament restraint system, was much more compact than ver. 2, and had bone flexibility in the tibia and femur. Figure 1 illustrates the JAMA-JARI legform impactor ver. 22. Its length and weight of the tibia and femur were the same as the TRL legform impactor because the values were derived from human data. However, the knee joint system and the bone flexibility differed considerably from the TRL impactor. Knee spring Knee ligaments JAMA-JARI legform impactor ver.22 Knee Joint (Knee ligament restraint system) Femur (Flexible) Tibia (Flexible) Figure 1. Overview of the JAMA-JARI legform impactor ver. 22. Konosu 1

VALIDATION METHODOLOGY The authors validated the impactor under quasi-static and dynamic loading conditions in the tests below. Quasi-static Bone Bending Test Quasi-static Knee Bending Test Dynamic Bone Bending Test Dynamic Knee Bending Test Dynamic Knee Shearing Test The quasi-static bone bending test result was compared with Yamada [7], and the quasi-static knee bending test result was compared with Ramet et al.ú [8]. The dynamic bone bending test result was compared with Nyquist et al. [9], and the dynamic knee bending and knee shearing test result was compared with Kajzer et al.ú [1]. The quasi-static knee shearing test was not performed due to time constraints. (1) Femur Bending Test RESULTS Quasi-static Bone Bending Test Figure 2 depicts the states of the quasi-static bone bending test. It is clear that the femur and the tibia of the new legform impactor can be bent against the lateral force. Figure 3 compares the bending characteristics of the legform impactor and PMHS. In the initial and intermediate loading phase, the legform bone bending characteristics are quite similar to the PMHS data. However, there were differences in the ultimate loading phase. The legform bone parts increase the bending force linearly relative to the bone deflection but the PMHS bone does not. The legform bone parts are composed of a Fiber Reinforced Plastic (FRP) and it has a wide range of the elastic region, however, the human bone has a narrow range of the elastic region, transit to the plastic region after around the 7 mm deflection in Figure 3. In order to simulate the plastic region phenomenon of human bone, the legform impactor must use a material which has a narrow range of elastic region not like FRP for its bone parts. The legform impactor must simulate the human bone bending characteristics yet must have durability for the impact test. If the bone parts break in each test, they will have to be repaired each time. The TRL legform impactor knee joints must be repaired after each test, so testing is expensive. Furthermore, the authors found that the plastic phenomenon does not significantly affect the bending curve in dynamic testing, so we kept the elastic material for the bone parts. Force (kn) (2) Tibia Bending Test Figure 2. Quasi-static Bone Bending Test. 4 Quasi-Static Three-Point Bone Bending Test 3.5 3 2.5 2 1.5 JAMA-JARI (ver. 22) - Tibia JAMA-JARI (ver. 22) - Femur 1 PMHS* - Tibia.5 PMHS* - Femur * PMHS: Yamada data (197) 5 1 15 Deflection (mm) Figure 3. Comparison of the Quasi-static Bone Bending Characteristics between the JAMA-JARI Legform Impactor and PMHS. Konosu 2

Quasi-static Knee Bending Test Figure 4 presents the states of the quasi-static knee bending test. The knee parts were fixed by a fixation device, and a bending moment was applied using a long bending lever arm. Figure 5 compares results of the knee bending characteristics for the JAMA-JARI legform impactor and PMHS, as well as the TRL knee joint stiffness. The JAMA-JARI legform impactor knee bending characteristics are comparable to PMHS characteristics. The TRL legform knee is quite stiff compared to the PMHS knee, i.e., stiffer than the JAMA-JARI legform impactor. The TRL legform impactor uses a steel bending plate, therefore, its moment-angle response in the initial phase is too stiff. The bending stiffness in the plastic bending phase is set at around 4Nm, and Kajzer et al.'s data support this value [11]. However, the authors believe the human knee bending stiffness is not so high even under dynamic loading conditions. Kajzer et al. stated that the knee joint bending stiffness is calculated using their PMHS test data (knee support force (F k ), trochanter support force (F t ), length from knee joint level to knee support (l k ), and length from knee joint level to trochanter support (l t )), but they did not show their equation clearly. It seemed that the high bending moments were derived from the formula, F t l t + F k l k, but it is quite incomprehensive. If the test is assumed as a simple, two point supported, pin end and roller end, bar bending test, the maximum bending moment should be generated at the knee support, F t l t -l k, and the bending moment at the knee joint level should be F t l t - F k l k. The formula, F t l t + F k l k, leads to a bending moment more than two times higher than the maximum at the knee support, therefore, the equation is inappropriate. Even when a built-in end is assumed at the trochanter support, the moment at the knee joint level should not be F t l t + F k l k. The authors therefore concluded that their formula, i.e., the high bending moment, is simply incorrect. Knee Fixation Apply a Pulling Force Bending Figure 4. Quasi-static Knee Bending Test. Bending Moment (Nm) 5 45 4 35 3 25 2 15 1 5 Quasi-Static Knee Bending Test PMHS corridor* JAMA-JARI (ver.22) TRL (ver.2) * PMHS corridor: Ramet et al.(1995) 5 1 15 Bending Angle (deg.) Figure 5. Comparison of the Quasi-static Knee Bending Characteristics between the JAMA-JARI Legform Impactor, TRL legform Impactor, and PMHS Konosu 3

DynamicBoneBendingTest Figure 6 describes the states of the dynamic bone bending test for the tibia. Nyquist et al. conducted dynamic bone bending test to the tibia. Authors conducted the same test for the tibia part of the JAMA-JARI legform impactor. Nyquist et al. conducted impact test on the tibia with the fibula and flesh part. The JAMA-JARI legform impactor does not have the fibula part because including it leads to a very complex construction for the legform impactor. Furthermore, a fibula fracture alone does not cause serious injury to the pedestrian. It is therefore, the tibia fracture assessment is set as a first priority and concentrated the tibia bending responses. The JAMA-JARI impactor retained the flesh part characteristics by using Memory foam TM as in the TRL legform impactor. We conducted the bone bending test with flesh buffer between the legform bone parts and the ram, and examined the total response of the tibia part of the JAMA-JARI legform impactor. Figure 7 compares the results of the dynamic bone (with flesh) bending characteristics for the JAMA-JARI legform impactor and PMHS. The initial slope is less than that of the PMHS, but the second slope is quite comparable. The initial slope is determined by the flesh and fibula part, suggesting that the Memory foam TM is slightly softer than the combined PMHS flesh and fibula. The second slope is primarily determined by the tibia bending stiffness, so the bone parts of the impactor compare favorably to the PMHS characteristics. The flesh part should exhibit much stiffer characteristics, but the tibia parts can remain as they are. Figure 6. Dynamic Bone Bending Test. -Tibia-. 7 6 Dynamic Three-Point Bending Test Impact Force (kn) 5 4 JAMA-JARI (ver.22) 3 PMHS* (Test No.118) 2 PMHS* (Test No.124) PMHS* (Test No.129) 1 PMHS* (Test No.132) PMHS* (Test No.152) 2 4 6 Deflection (mm) *PMHS data: Nyquist et al. (1986) Figure 7. Comparison of the Dynamic Bone Bending Characteristics between the JAMA-JARI Legform Impactor and PMHS. Konosu 4

Dynamic Knee Bending Test Figure 8 details the states of the dynamic knee bending test comparing the JAMA-JARI legform impactor and the TRL legform impactor. The bending angle of the TRL legform impactor is smaller than that of the JAMA-JARI one. Figure 9 compares the dynamic knee bending responses of the JAMA-JARI legform impactor, TRL legform impactor, and PMHS. As for the TRL legform impactor, the impact force is quite high and the knee bending angle is less than that of the PMHS. On the other hand, the JAMA-JARI legform impactor response is comparable to that of the PMHS. TRL impactor bone parts do not deform in the test. This means the impact energy concentrates on the knee joint, i.e. the knee joint is subject to larger bending moment. However, the generated bending angle is lower than that of the PMHS one. It means clearly that the TRL knee joint has inappropriate knee joint stiffness. It is true that the initial phase of the bending angle of JAMA-JARI impactor is also lower than the PMHS corridor, however, the difference is lead by the fresh characteristics. Therefore, it can be modified by using another material for the fresh part. Impact force (N) 4 3 2 1 1 2 3 4 Time (ms) Figure 8. Dynamic Knee Bending Test. JAMA-JARI (ver.22 ) TRL (ver.2) (1) Impact force (2) Bending angle Bending angle (deg.) Figure 9. Comparison of the Dynamic Knee Bending Characteristics between the JAMA-JARI Legform Impactor, TRL Legform impactor, and PMHS. 2 18 16 14 12 1 8 6 4 2 JAMA-JARI (ver.22) TRL (ver.2) 1 2 3 4 Time (s) Konosu 5

Dynamic Knee Shearing Test Figure 1 presents the states of the dynamic knee shearing test comparing the JAMA-JARI legform impactor and the TRL legform impactor. The TRL legform impactor can only move its knee shear spring inside the femur. The total kinematics around the knee is thus quite different from that of the JAMA-JARI legform impactor. Figure 11 compares the dynamic knee shearing responses of the JAMA-JARI legform impactor, TRL legform impactor, and PMHS. On the TRL legform impactor, the impact force response is extremely high and the knee shearing displacement is quite low. It means the TRL impactor is quite stiff not only for bending but also for shearing. And the rigid bone also may affect the difference from the PMHS response. As for the JAMA-JARI legform impactor, only the unloading curve after the initial loading of the impact force differs from that of the PMHS. In that phase, however, the shearing displacement already reached to the injury level. Therefore, authors believe the difference does not affect to the proper ligament injury assessment. Impact force (N) 5 4 3 2 1 5 1 15 2 25 Time (ms) Figure 1. Dynamic Knee Shearing Test. JAMA-JARI (ver.22) TRL (ver.2) Shearing displacement (mm) 6 5 4 3 2 1 JAMA-JARI (ver.22 ) TRL (ver.2) 5 1 15 2 25 Time (ms) (1) Impact force (2) Bending angle Figure 11. Comparison of the Dynamic Knee Shearing Characteristics between the JAMA-JARI Legform Impactor, TRL Legform impactor, and PMHS. Konosu 6

DISCUSSION The JAMA-JARI legform impactor (ver. 22) achieved high biofidelity not only at the component parts level but also at the assembly level. The TRL legform impactor cannot simulate bone flexibility and has a very stiff knee joint; therefore, its biofidelity is quite low. It may be possible to improve its knee bending response by using softer bending material for its knee joint, but the lack of bone flexibility is a fatal flaw in properly estimating bone fractures. Proper bone fracture assessment is required because the current accident data show high rates of bone fractures with quite low rates of knee ligament injuries. The TRL legform impactor is barely able to assess upper tibia fractures by using a built-in accelerometer, but it is quite difficult to assess the severity of bone injuries in other locations. Even if accelerometers are installed in other bone locations, the output differs significantly from the PMHS response [4]. Moreover, using a flexible legform impactor that can generate the proper acceleration at all bone location, bone fractures can be assessed by measuring the strain on a flexible leg (bone severity can be assessed directly). Therefore, the JAMA-JARI legform impactor which has flexible bone has a high potential for producing proper pedestrian leg injury assessments. JAMA and JARI will therefore continue to develop a flexible legform impactor. CONCLUSIONS 1. JAMA-JARI legform impactor ver. 22 has high biofidelity at both the component and assembly levels. 2. JAMA-JARI legform impactor ver. 22 has a high potential for producing proper pedestrian leg injury assessments. ACKNOWLEDGEMENTS REFERENCES [1] European Experimental Vehicles Committee, EEVC Working Group 1 report, Proposals for methods to evaluate pedestrian protection for passenger cars, November 1994. [2] European Enhanced Vehicle-safety Committee, EEVC Working Group 17 report, Improved test methods to evaluate pedestrian protection afforded by passenger cars, 1998. [3] Matsui Y., Ishikawa H., Sasaki A., Kajzer J., and Schroeder G., Impact response and biofidelity of pedestrian legform impactors, Proc. IRCOBI Conference, 1999, pp. 343-354. [4] Konosu A., Ishikawa H., and Tanahashi M., Reconsideration of injury criteria for pedestrian sybsystem legform test - Problems of rigid legform impactor, 17th ESV, 21, Paper No. 263 [5] Matsui Y., Biofidelity of TRL legform impactor and injury tolerance of the human leg in lateral impact, Stapp Car Crash Journal, Vol. 45, November 21, Paper No. 21-22-23 [6] Wittek A., Konosu A., Matsui Y., Ishikawa H., Shams T., and McDonald J., A new legform impactor for evaluation of car aggressiveness in car-pedestrian accidents, 17th ESV, 21, Paper No. 184 [7] Yamada H., Strength of biological materials, The Williams & Wilkins Company, 197. [8] Ramet O. et al., Shearing and Bending Human Knee Joint Tests in Quasi-Static Lateral Load, IRCOBI, 1995 [9] Nyquist W. G. et al., Tibia Bending: Strength and Response, SAE Paper No. 851728 [1] Kajzer J., Matsui Y., Ishikawa H., Schroeder G., and Bosch U., Shearing and Bending Effect at the Knee Joint at Low Speed Lateral Loading, SAE Paper No. 1999-1-712 [11] Kajzer J., Schroeder G., Ishikawa H., Matsui Y., and Bosch U., Shearing and Bending Effect at the Knee Joint at High Speed Lateral Loading, STAPP Paper No. 973326 The authors thank to all the people who supported this project. Konosu 7