Power Quality Logger Model PQL 120

Similar documents
Digital Transformer Ratiometer DTR Model 8500

5000V Graphical Megohmmeter Model 5070

Selection Guide to Clamp-On Current Probes

Multi-Function Ground

Understanding Insulation Resistance Testing

3U 4V 4A L1 L2 L3 V2 = 314 V3 = -84 N = -14 > ensuring high performance C.A 8332B C.A 8334B C.A 8335 POWER AND ENERGY QUALITY ANALYSERS

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Understanding Soil Resistivity Testing

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Simple Logger II Data Loggers

Titelgrau belassen! Leere Vorlage

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Product Information Sheet UH36 Hi Pot Tester

Current Monitoring Kit QUICK START GUIDE

Current Monitoring Kit

Model SL355 Noise Dosimeter/Datalogger

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

USB-500/600 Series Low-Cost Data Loggers and Accessories

Online UPS. PowerWalker VFI 1000R/1U

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Disturbance Recoder SPCR 8C27. Product Guide

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500 Series Low-Cost Data Loggers and Accessories

Temperature & Humidity SMS Alert Controller

1. SAFETY INFORMATION

DataView DVTH Data Logger for Temperature and Humidity

Transmitter Interface Program

Technical Data. back-up time in minutes 100% load % load

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Power Log PC Application Software

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

NortechCommander Software Operating Manual MAN R6

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

Back-UPS Pro 1300/1500 Installation and Operation

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

User's Guide Integrating Sound Level Datalogger Model

Power Log PC Application Software

Uninterruptible Power Supply

Impedance 50 (75 connectors via adapters)

T Substation Maintenance and Commissioning Test Equipment

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Frequency selective monitoring and logging of environmental electromagnetic fields

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

User Guide. Temperature and Humidity Datalogger. Model 42280

User Manual 1K/2K/3K Online UPS

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Electronic Control Devices The European Product Catalogue 2007

Analyser-Oscilloscopes

Philips PageWriter Touch ECG System

Product Information Sheet UH28CS-12kV Hi Pot Tester

PCS0100en Persy Control Services B.V. Netherlands

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.

EnerVista TM Viewpoint Monitoring v7.10

Power Meter Series 700

iva Cable & Antenna Analyzer

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Powerware 5110 UPS User s manual

SW43W. Users Manual. FlukeView Power Quality Analyzer Software Version 3.20 onwards

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Electronic Control Devices The European Product Catalogue 2007

Quick Connect. quick - simple - efficient.

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Weather Capture Software Guide Version 1.4 Revision: June

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

NC-12 Modbus Application

PD 100A. Printing data system

3500/22M Transient Data Interface

HI/ICMI UVR-1 Universal Voltage Regulator Control

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Temperature Datalogger Users Manual

Metering Devices IQ Analyzer 6400/6600 Series

Energy Management Power Analyzer Type WM14-96 Basic Version

USER MANUAL V5.0 ST100

iva Cable & Antenna Analyzer

4-Channel Thermometer / Datalogger

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

GPS Vehicle and personal location tracker. User manual

Dock HP Pro Portable Tablet Dock. HP Quick Charge 18W AC Tablet Adapter. HP Duet Pen Refills. Cables HP Micro USB to USB Adapter

Integrating Sound Level Meter and Datalogger

Data Loggers for Real Time Temperature Monitoring - WiFi

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

USER MANUAL Online UPS 1K/2K/3K

SA-9600 Surface Area Software Manual

How To Use A Power Supply Unit (Upu)

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Noise Monitoring Software, version 7.0 Types 7802 and 7840

USB Edition TM-STD30 User Guide

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

COST EFFECTIVE EMBEDDED POWER MONITOR. Kevin Harris Marketing Manager TEAL Electronics

Transcription:

Power Quality Logger Model PQL 120 Power Quality Analysis Made Simple! US Patent Number 6,424,277 The PQL 120 Series is a single phase Power Quality Logger designed to measure and log from a complete suite of electrical and power quality parameters. It is accompanied by an easy-to-use report compliant software package. We provide several report templates to facilitate your work. The PQL 120 Series is designed for North American commercial, industrial and residential applications, and is plugged into a standard AC receptacle. In turn, any 120V load may be plugged into the Power Quality Logger: office equipment, data equipment, machinery, compressors, heaters, motors, etc. In industrial, commercial and residential sites, power quality is critical and may induce many problems, the causes of which need to be identified. Outages reset clocks, timers and other sensitive devices; odd harmonics cause overheating in neutrals; harmonic energy causes motors and other devices to run improperly; spikes cause lighting to burn out prematurely; and surges and sags cause irritating flicker in lighting systems as well as inefficient machine operation. The main advantage of the PQL 120 Series is its ability to perform a wide variety of recording tasks with high resolution and accuracy and easy, intuitive setup from a computer. The PQL 120 measures, records and stores selected parameters in its memory. Along with standard electrical parameters (V, A, W, Var, PF ), it also stores the Power Quality of the input waveforms (Harmonics, THD, Surge, Sag, K-Factor ). The recorded information is retrieved from a computer via an RS-232 serial link using the report compliant DataView software package, which provides graphs, data and pre-configured reports. With the DataView edition, measurements and waveforms may be viewed in real time on a computer monitor and stored directly into the computer memory. Custom views and reports can then be created. The Power Quality Logger is line powered from the voltage source that it is connected to, with an internal battery to protect data integrity during power outages for up to one year. Technical Assistance (800) 343-1391 www.aemc.com 1 of 8

Features Portable, compact unit plugs into standard US 120V outlets Simple operation: Plug in, Record, Download and Read Measures and stores electrical parameters: V, A, Hz and more Measures and stores power parameters: W, VA, VAR, Demand, Peak Demand and more Measures and stores power quality parameters: Harmonics, THD (RMS and fundamental), K-Factor and more Automatically captures worst-case Surge, Sag and THD waveforms High accuracy and resolution: 128 samples/cycle, 16 bit resolution LEDs indicate mode of operation Records up to 12 data channels Powered from voltage input channel Battery backup data integrity during power outages for up to one year (configuration in non-volatile memory) Optically isolated RS-232 output for direct connection to a PC IEC 1010, 150V Cat. III Includes DataView software for data storage, analysis and report generation Applications Monitor power quality in North American commercial, industrial and residential application Monitor power quality at computer workstations Monitor power quality on laboratory equipment PARAMETER UNIT RMS MIN MAX VALUE WAVEFORM SPECTRUM TEXT COMMENTS Voltage V 4 4 4 4 4 4 Waveforms & Spectrum in real time using DataView Current A 4 4 4 4 4 4 Waveforms & Spectrum in real time using DataView Frequency Hz 4 4 4 4 Even Voltage Harmonics V 4 4 4 4 Odd Voltage Harmonics V 4 4 4 4 Even Current Harmonics A 4 4 4 4 Odd Current Harmonics A 4 4 4 4 Real Power W 4 4 4 4 Reactive Power Var 4 4 4 4 Apparent Power VA 4 4 4 4 Total Harmonic IEEE (THDrms) or IEC (THDfund); Distortion 4 4 4 4 4 4 Five worst waveforms for Voltage & Current Power Factor 4 4 4 4 Displacement Power Factor 4 4 4 4 K-Factor 4 4 4 4 Demand VA, W 4 4 10/15/30 minutes or user-definable in one min. increments Peak Demand VA, W 4 4 Peak within the Demand Interval Sag V 4 4 4 4 Surge V 4 4 4 4 Five worst in Hi-Resolution up to 256 single cycle RMS values & worst-case THD waveforms per event; Table of 100 worst-case events containing severity & time; Even counter for all triggered values Technical Assistance (800) 343-1391 www.aemc.com 2 of 8

Specifications Model PQL 120 Electrical Measurements True RMS measurement. 128 samples are simultaneously taken for voltage and current channel. Voltage 0 to 140V Resolution 0.1V Accuracy ±(0.3% of Reading + 0.3V) Current 0 to 15A (70A peak maximum) Resolution 0.01A Accuracy ±(0.5% of Reading + 0.03A) @ 0.75A to 15A ±0.30A @ < 0.75A Frequency (Hz) 45 to 65Hz Resolution 0.01Hz Accuracy 0.1Hz Harmonics Up to 50th for both Voltage & Current Resolution 0.1V for Voltage & 0.1A for Current Power Watt/va/var 0 to 2,100 Watt, VA or Var Resolution 0.1W, 0.1VA, 0.1Var Accuracy ±(2.0% of Reading + 4x), where x is Watt or VA or Var Power & Power Factor Resolution 0.01 Accuracy ±0.03% @ PF/DPF = 1 Programmable Parameters V, A, Hz, Odd & Even Harmonics ( V & A), W, VA, Var, THD (V & A), PF, DF, K-Factor Demand VA, W (10/15/30 minutes or user-definable) Peak Demand Over demand period Voltage Sag User-definable magnitude Voltage Surge User-definable magnitude Input Input Channels One Voltage/One Current Sample Rate 128 per cycle per channel Recording Storage Rate 125ms to 7 days Recording Session Length 15 minutes to 8 weeks (user programmable) Total Memory 1MB Date and Time MM/DD/YY hh/mm/ss.sss Surge and Sag and THD Waveform Storage 20 worst-case Environmental Operating Temperature 14 to 122 F (-10 to 50 C) Storage Temperature -4 to 140 F (-20 to 60 C) Relative Humidity 0% to 85% @ 95 F (35 C), non-condensing Mechanical Material UL94V-O ABS plastic Dimensions 5.91 x 3.15 x 2.36" (150 x 80 x 60mm) Weight 1 lb 7 oz (650g) including the batteries Safety Safety Rating IEC 1010-1, 150V Cat. III, Pollution Degree 2 Technical Assistance (800) 343-1391 www.aemc.com 3 of 8

LED s indicate mode of operation Monitor power quality at computer workstations RS-232 interface for easy connection to a PC Standard three-prong current input receptacle Monitor power quality on laboratory equipment Technical Assistance (800) 343-1391 www.aemc.com 4 of 8

Construction 1. Control button (Record Start/Stop) 2. Three LED Indicators Red LED Yellow LED Green LED 4. Female DB-9 Serial Connector 3. Reset button Standard 3-prong current input receptacle 1. Control Button (Record Start/Stop) Used to start or stop recording and erase recording memory 2. Three LED Indicators RED LED: Indicates the presence of AC line voltage. The logger turns ON when the input voltage > 75V YELLOW LED: Indicates the status of the memory. LED OFF: No data in memory LED ON: Memory is partially filled LED Single Blink: Memory is full GREEN LED: Indicates the status of the data logger (STANDBY or RECORDING) LED Single Blink: PQ Logger is in Standby Mode (and not recording) LED Double Blink: PQ Logger is in Record Mode NOTE: When the AC line power is turned off and the PQ Logger is not recording in a ride-through mode, the GREEN LED is OFF. If the GREEN LED remains continuously ON without blinking, or OFF even when the RED LED is ON, a fault condition has occurred 3. Reset Button This button resets the CPU. The button is recessed and requires a small tool, such as a pen, to press it. Do not press the Reset Button under normal operation. If the Reset Button is pressed when the PQ Logger is recording, it will stop recording and data in the memory may be lost. 4. Female DB-9 Serial Connector Technical Assistance (800) 343-1391 www.aemc.com 5 of 8

DataView Software for Model PQL 120 Features Display and analyze real-time data on your PC Configure all data logger functions and parameters from your PC including sample rate, recording length, channel configuration and more Customize views, templates and reports to your exact needs Create and store a complete library of configurations that can be uploaded to the logger as needed Zoom in and out and pan through sections of the graph to analyze the data Download, display and analyze recorded data Display real-time data on your PC and download previously recorded data Display waveforms, trend graphs, harmonic spectrums and text summaries Display surge and sag events in high-resolution waveforms and as tabular listings Print reports using standard or custom templates you design Minimum System Requirements: Windows 2000/XP/Vista 128MB of RAM for Windows 2000 (256MB of RAM recommended) 256MB of RAM for Windows XP 512MB of RAM for Windows Vista 35MB of hard disk space (200MB recommended) CD-ROM drive DataView is included with the Power Quality Logger. View data in real time on your PC. Customize the layout to include what s important to you. Configure your logger from your computer. Select record length, sample rate, channel information to be recorded and more. A comprehensive set of tools lets you customize templates and reports to your specific needs. Technical Assistance (800) 343-1391 www.aemc.com 6 of 8

Accessories Model PQL 120 Catalog #2125.04 DataView Model PQL 120 with DataView software and 6 ft DB-9 M/F serial PC cable Catalog #2125.03 Soft Carrying Case Catalog #2119.02 ORDERING INFORMATION CATALOG NO. Power Quality Logger Model PQL 120 (1MB)...Cat. #2125.04 PQL is supplied with DataView software (CD ROM), 6 ft DB-9 M/F serial PC cable, and a user manual. Accessories (Optional) Soft Carrying Case...Cat. #2119.02 Technical Assistance (800) 343-1391 www.aemc.com 7 of 8

Contact Us United States & Canada: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 200 Foxborough Blvd. Foxborough, MA 02035 USA (508) 698-2115 Fax (508) 698-2118 www.aemc.com Customer Support for placing an order, obtaining price & delivery: customerservice@aemc.com Sales Department for general sales information: sales@aemc.com Repair and Calibration Service for information on repair & calibration, obtaining a user manual: repair@aemc.com Technical and Product Application Support for technical and application support: techinfo@aemc.com Webmaster for information regarding www.aemc.com: webmaster@aemc.com South America, Central America, Mexico, Caribbean, Australia & New Zealand: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA (978) 526-7667 Fax (978) 526-7605 export@aemc.com www.aemc.com All other countries: Chauvin Arnoux SCA 190, rue Championnet 75876 Paris Cedex 18, France 33 1 44 85 45 28 Fax 33 1 46 27 73 89 info@chauvin-arnoux.com www.chauvin-arnoux.com Technical Assistance (800) 343-1391 www.aemc.com 8 of 8