Emergency Power-Off System

Similar documents
Triple Expansion Chassis

BroadBand PowerShield. User Manual

Installation Guide Smart-UPS X External Battery Pack SMX120BP

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Installation. Basic Rack Power Distribution Unit AP9559

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

APC Step-Down Transformer. User s Manual

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

Advantium 2 Plus Alarm

Unpacking, Installation, and Customization

How To Install A Power Supply (Uplast) With A Battery Pack

Out-of-Band Management Card

HMI display Installation Guide

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

Single Station Remote Alarm

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

Operation and Installation Manual

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

User Manual. English. APC Smart-UPS RT. 3000/5000/6000 VA VAC Tower/Rack Mount 3U Uninterruptible Power Supply

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

Understanding Emergency Power Off (EPO)

Back-UPS Pro 1300/1500 Installation and Operation

User Manual. Smart-UPS TM C. Uninterruptible Power Supply SRC250 SRC /120/230 Vac. Tower/Rack-Mount 1U

Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA

User Manual. English. APC Smart-UPS VA 120/230 Vac VA 100/120/208/230 Vac. 2U Rack Mount Uninterruptible Power Supply

User Manual. English. APC Smart-UPS RT. 8000/10000 VA Vac Tower/Rack-Mount 6U Uninterruptible Power Supply

12-Volt 10-Amp Regulated Power Supply

Operation Manual. Smart-UPS UPS. 750/1000/1500/2200 VA Rack-mount 2U 120/230 VAC VA Rack-mount 2U 120/208/230 VAC

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

750VA/1000VA/1500VA 100/120/230VAC 2U

About Your NetBotz 4-20mA Sensor Pod

User Guide. HDMI Active Cable Extender. DVI-7370c

Model SRMD Setra Remote Monitoring Display

Installation and Operation Back-UPS 1250, 1300, 1500

Model 201 Wiegand Touchpad Reader Installation Guide

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

Machine Safety Switch: SI-LM40 Series Limit Switch Style

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Installation and Operation

Operation Manual. Smart-UPS X Uninterruptible Power Supply

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Water Leak Detection System

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

DUCT SMOKE DETECTOR D4120

LIEBERT VNSA Installation Sheet

On/Off Relay Switch and 3-Way Switch Kit

, User s Manual

Solid-State Timer H3G

Dolphin 9900 Mobile Computers

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Remote Alarm Monitoring System

ATS Overhead Table Shelf System INSTRUCTION MANUAL

AXIS T81B22 DC 30W Midspan

Installation and Operation Guide PD4600 Series Converter Replacement

PEDAL POWER. User s Manual

Instructions for Connecting PETROSMART EZ Control Systems To Wayne Electronic Dispensers With/Without CAT CREDIT CARD MODULES

Architect/Contractor Information Package

CompactLogix Power Supplies Specifications

INSTALLATION INSTRUCTIONS

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

Installation and Operation Guide for PD4000 Series Power Control Center

PS6500 Storage Arrays Rack Mount Instructions

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Bubble King. User Manual

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

TrueAlarm Fire Alarm Systems

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Model PS-4001 Power Supply User Instructions

APC Smart-UPS 2400/3000 VA 100/ VAC 3U. Uninterruptible Power Supply

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Installation and Operation Guide for PD4100 Series Power Control Centers

V-2901 UNIVERSAL DOOR ANSWERING SYSTEM

16/32 Channel 1U Rack Mount CCTV Power Supply

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Electronic Control Devices The European Product Catalogue 2007

OAK WORKBENCH WITH 2 DRAWERS

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Crestron TMK-6L & WMKT-6L Trim Ring Mount Kits Installation Guide

Canopy Surge. User Manual

Leak Detection System

PagePac PAGEPAL V

Battery Charger. Instruction Manual G

Power Management Module 2. Installation

Transcription:

Emergency Power-Off System The Emergency Power-Off (EPO) System consists of one or more wall-mounted, push-button EPO boxes. Each EPO box provides a single point of equipment shutdown for up to eight APC InfraStruXure devices and one third-party device (such as an upstream breaker), using normally open (NO) contact closure connections. An EPO box may be cascaded with other EPO boxes to support multiple points of equipment shutdown. See page 13 for a listing of InfraStruXure Devices that are currently compatible with this system. Although designed specifically for InfraStruXure products, the EPO system can be used for tripping any devices that fall within its parameters. See Specifications on page 16 to confirm proper application, and install according to the instructions in this manual. See also For more information about emergency power-off, see white paper #22, Understanding Emergency Power Off (EPO), on the APC Web site (www.apc.com).

Contents Overview......................................... 1 Safety....................................... 1 EPO box components............................. 2 Installation........................................ 3 Open the EPO System box......................... 3 Mount the system on a wall........................ 3 Connect devices to the EPO box..................... 7 Mount additional EPO boxes........................ 7 Cascading multiple EPO boxes....................... 8 Direct wiring alternative.......................... 10 Verify connections at each EPO box.................. 11 Operation........................................ 12 APC InfraStruXure Devices............................ 13 Mounting Hole Template............................. 14 Wiring Diagram.................................... 15 Specifications..................................... 16 Warranty and Service............................... 17 Limited warranty............................... 17 Warranty limitations............................ 17 Obtaining service.............................. 17 EPO System Installation and Operation i

Overview Safety Save these instructions. This manual contains important instructions that should be followed during installation and maintenance of the system. Safety instructions for North America and Canada Electrical Hazard Caution Only a certified electrician can install the system and the wiring to the products it controls. Wiring from the system to the products it controls can either be installed in conduit or installed without conduit if the wires are in accordance with Article 725 of the National Electrical Code (NFPA 70) and Section 16 of the Canadian Electrical Code (C22.1). Only Class 2 circuits rated 30 V or less shall be connected to terminals 1 8. Class 2 circuits are defined in Article 725 of the National Electrical Code (NFPA 70) and Section 16 of the Canadian Electrical Code (C22.1). A Class 2 circuit is a source having limited voltage and energy capacity as follows: a. If an Inherently Limited Power Source, voltage is limited to 30 VAC or 30 VDC, and energy is limited to 8 A. b. If not an Inherently Limited Power Source, voltage is limited to 30 VAC or 30 VDC, energy is limited to 250 VA, and current is limited to 1000/Vmax. The fuse is limited to 5 A if maximum voltage is 20 V, or 100/Vmax if voltage is greater than 20 V but less than 30 V. EPO System Installation and Operation 1

Overview Safety instructions for Europe, Middle East, and Africa Electrical Hazard Caution Only a certified electrician can install the system and the wiring to the products it controls. Wiring from the system to the products it controls can either be installed in conduit or without conduit if the wires are in accordance with IEC/EN 60364-5-52 or equivalent local electric code. EPO can be achived with either a contact closure or application of an external 24VAC or 24VDC from a SELV or PELV source. It is important to note that hazardous voltage from the Mains voltage must be isolated from the contact closure or 24VAC, 24VDC. The EPO circuit contact closure, the 24VAC, or the 24VDC are considered a SELV circuit as defined in EN60950 Safety of Information Technology Equipment or PELV circuit as defined in IECDD 60364-4-41 Electrical Installations of Buildings Protection for Safety Protection Against Electric Shock. SELV is an abbreviation for Safety Extra Low Voltage. PELV is an abbreviation for Protective Extra Low Voltage. SELV and PELV circuits are isolated from the Mains through a safety isolating transformer, and designed so that under normal conditions the voltage is limited to 42.4Vpeak or 60VDC. 2 EPO System Installation and Operation

Overview EPO box components! Flag $ " Button # Shield $ Knock-outs % Mounting holes # " & ' Blanking panels Wire anchors! ( Auxiliary device terminal % ) InfraStruXure device terminal block * Cascading jacks + Wiring check points, Ground stud - Cable clamps & ' ( ) * - +, Wiring, conduit, and mounting hardware are not provided. EPO System Installation and Operation 3

Installation Open the EPO System box Remove the screws on the side of the box and open. Keep the screws for after the system is installed. The box will not close securely without the screws in place. Mount the system on a wall Mount the system in a readily-accessible area, on a wall near the principal entrance doors, according to NEC articles 645.10 and 645.11, IEC/EN 60354-5-537, or equivalent local regulation. There are two different procedures for mounting the system, depending on if you are running conduit along the wall (page 4) or behind the wall (page 5). In countries where conduit is not used, run the cables from the connected devices or the cascaded EPO boxes directly to the EPO using Shielding Troughs and Cable Ladders. 4 EPO System Installation and Operation

Installation If you are running conduit (or cables) along the wall. 1. Use four ¼-inch (6.35-millimeter) screws and fasten the screws through the four mounting holes at each corner of the EPO box and into the wall. (See page 14 for a template.) 2. Run the conduit (or cables for the connected devices) to the EPO box. The conduit will contain all wiring from the connected devices and all cascading cables. The knockouts in the top and bottom of the EPO box accept.- (13-) and /-(19-) inch (millimenter) conduit or clusters of cables. Remove the knockouts required for your installation. When planning your conduit requirements, consider that two cascading cables will fit in.-inch (13-millimeter) conduit and four cascading cables will fit in /-inch (19- millimeter) conduit. See Cascading multiple EPO boxes on page 8 for more information. 3. Install an appropriate fitting with a lock-nut for each knockout that you are using. 4. Connect your conduit (or cables) to the fittings. EPO System Installation and Operation 5

Installation IIf you are running conduit (or cables) behind the wall. 1. Install a junction box behind the wall. The EPO box will fasten directly to the junction box. You can use one of the following options: One 4-inch square junction box Two 4-inch square junction boxes One switch box up to 4-gang in size 2. Run the conduit (or cables from the connected devices) to the junction or switch box. The conduit will contain all wiring from the connected devices and all cascading cables. Remove the knockouts required for your installation. When planning your conduit requirements, consider that two cascading cables will fit in.-inch (13-millimeter) conduit and four cascading cables will fit in /-inch (19-millimeter) (conduit. See Cascading multiple EPO boxes on page 8 for more information. 3. Install an appropriate fitting with a lock-nut for each knockout that you are using. 4. Connect your conduit (or cables) to the fitting. 5. Remove one or both of the blanking panels covering the window in the back of the box, as required. 6 EPO System Installation and Operation

Installation 6. Secure the EPO box directly to the junction or switch box with the appropriate number of 6-32 screws around the access window. 7. Reinforce the EPO box with 0-inch (6.35- millimeter) screws in the corner mounting holes. (See page 14 for a schematic of the EPO box mounting holes.) The top two 0-inch (6.35- millimeter) mounting holes may be blocked by some junction boxes. In this instance, use only the bottom two 0-inch (6.35-millimeter) mounting holes for reinforcement. EPO System Installation and Operation 7

Installation Connect devices to the EPO box Terminals 1 8 are for connecting to APC InfraStruXure devices. Terminal 9 is for connecting to an auxiliary device. Connect only one wire pair (24 18 AWG) to each terminal block. 1. Attach EPO circuits to each InfraStruXure device according to the specific instructions for that device. Use the normally open (NO) contact option. 2. Run suitable wire (24 18 AWG) from the InfraStruXure devices through the conduit to terminals 1 8 on the EPO box terminal block. Make the connections to the terminal block in numerical order (terminal 1, and then terminal 2, etc.). 3. Run suitable wire (22 18 AWG) from the contact closure points for any auxiliary device through the conduit to terminal 9 on the EPO box terminal block. The auxiliary circuit is rated 1A at 48VDC/240VAC. 4. If necessary, secure wires inside the box using the releasable wire ties (provided). Thread the wire ties through the square wire anchors in the box. 5. Connect a suitable ground or PE wire to the #8-32 ground stud in the lower left corner of the EPO box. Mount additional EPO boxes To mount additional EPO boxes at other exit doors, follow the instructions in Mount the system on a wall on page 3. You have two alternatives for wiring your additional EPO boxes. You can cascade the boxes so that you only wire devices to one box (see page 8), or you can wire devices directly to each EPO box (see page 10). 8 EPO System Installation and Operation

Installation Cascading multiple EPO boxes When cascading EPO boxes, connect a wire pair from each device to the first EPO box according to the procedure in Connect devices to the EPO box on page 7. Jumper the subsequent EPO boxes with cascading cables (standard Cat-5 cable) this will join the EPO boxes in parallel. InfraStruXure Device InfraStruXure Device InfraStruXure Device Auxiliary Non-InfraStruXure Breaker InfraStruXure Device 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 CAT-5 CAT-5 EPO Box 1 EPO Box 2 EPO Box 3 InfraStruXure Device InfraStruXure Device InfraStruXure Device InfraStruXure Device The recommended maximum total distance of wire you can run per circuit is 1000 feet (300 meters). EPO System Installation and Operation 9

Installation Cascade the InfraStruXure devices with Cat-5 cables. Connect the Cat-5 cables to the jacks inside the EPO box. Each cable can support up to four InfraStruXure device wire pairs. Follow these guidelines when connecting Cat-5 cables: Use only the bottom jacks (# and $) if you are cascading four or fewer InfraStruXure devices. Use both the bottom and the top jacks (!, ", #, and $) if you are cascading five or more InfraStruXure devices. Connect the output jacks (! and #) of the first EPO box to the input jacks (" and $) of the second EPO box. Continue until all boxes are connected. If necessary, use the white cable clamps to secure the Cat-5 cables. Box 1 Box 2 Output In put! " # $ Cascade the auxiliary device with wire pairs. After you have ran wires from your auxiliary device (!) to terminal block position 9, run a second set of wires (") from terminal block position 9 on the first EPO box to terminal block position 9 on the second EPO box. Continue until all boxes are connected. (See the diagram on page 8 for reference.) 10 EPO System Installation and Operation

Installation Direct wiring alternative If the InfraStruXure devices are centrally located between exit doors, it may be more practical to run separate wire pairs from the devices to each EPO box. This requires terminal block connections in every EPO box, rather than cascading cables between boxes. Connect wire pairs from the Normally Open (NO) contacts on the InfraStruXure devices to each EPO box. Because this alternative results in multiple wire pairs at the terminals of the InfraStruXure devices, it is not recommended for use with more than three EPO boxes. InfraStru Xure Device InfraStru Xure Device 1 2 3 4 5 6 7 8 9 InfraStru Xure Device 1 2 3 4 5 6 7 8 9 EPO Box 1 Auxiliary Non-InfraStruXure EPO Box 2 Breaker EPO System Installation and Operation 11

Verify connections at each EPO box 1. Verify that the wiring is correct before attaching critical load devices to your InfraStruXure devices: a. With the devices powered ON, use a small tool to press each check point, one at a time. Warning Pressing the check point will shut down the connected device and any load it is supporting. If you have an APC FM Series Precision Air Conditioning System connected, pressing the check point will shut off functionality to the unit, but it will still be powered. b. After you have verified the wiring, close the system box, making sure not to pinch wires or disturb connections, and secure with the screws you previously removed. c. As a final test, apply power to all InfraStruXure and auxiliary devices, and then press the EPO button. All connected devices should power OFF immediately. Repeat this final test at every EPO box in your system. See also The InfraStruXure PDUs have an EPO test feature that verifies EPO operation without shutting down the connected loads. Refer to your PDU operation manual for details. 12 EPO System Installation and Operation

Operation To engage the system: Lift the shield on any of the boxes that are installed and press the button. When you lift the shield, a red flag drops down from the box to indicate that the shield on the EPO box has been opened, so that if the button is engaged, you will have an easy visual mark as to which EPO box in your room has been activated. To reset the EPO system: Pull the button toward you. Pulling the button does not bring power back to connected equipment; it only resets the EPO system. To close the shield: Push the flag (!) back up into the box and snap the shield tight ("). " To reset your equipment: Apply power to your devices according to the procedures for each device.! EPO System Installation and Operation 13

APC InfraStruXure Devices The list below is a selection of compatible APC InfraStruXure devices that you can connect to the EPO system. InfraStruXure for Computer Rooms and Wiring Closets Smart-UPS 3000/5000 RM Symmetra RM UPS InfraStruXure for Medium Data Centers Symmetra PX UPS InfraStruXure PDU InfraStruXure for Large Data Centers Symmetra MW UPS InfraStruXure PDU Precision Air Products NetworkAIR FM The EPO system connects to the InfraStruXure PDU, unless the UPS is sold alone. 14 EPO System Installation and Operation

Mounting Hole Template The following illustration shows the location of the mounting holes on the rear of the EPO box. The measurements are in inches (millimeters). 7.87 (200) 7.64 (194) EPO System Installation and Operation 15

1 2 Wiring Diagram SW9 2 3 1 1 2 J9 SW8 2 3 1 1 2 J8 SW7 2 3 1 1 2 J7 SW6 2 3 1 1 2 J6 SW5 2 3 1 1 2 J5 SW4 2 3 1 1 2 J4 SW3 2 3 1 1 2 J3 SW2 2 3 1 1 2 J2 SW1 2 3 1 J1 1 3 5 2 4 6 7 8 16 EPO System Installation and Operation

Specifications Electrical Input/Output Voltage 24VDC (InfraStruXure circuits) 48VDC/240VAC (External circuit) Current 1A at 24VDC (InfraStruXure circuits) 1A at 48VDC (External circuit) Frequency 50/60Hz Circuits (qty) 9 Contact state Normally open (NO) Physical Dimensions (W L D) EPO box 8.9 9.9 2.6 in (226 251 66mm) Shipping 12 12 5.5 in (305 305 140mm) Weight EPO box 6.4 lb (2.9kg) Shipping 6.9 lb (3.1kg) Mounting Surface mount Connection Removable panels in rear,.-in and /-in knockouts on top and bottom Push button Standard, 22-mm metallic body; 40-mm mushroom head; Push/pull Wire connections #24 to 18 AWG wire ground stud for #8 ring lug Environmental Temperature Humidity Elevation Compliance 23 to 113 F ( 5 to 45 C) 5 to 95% RH, non-condensing 10000ft (3000m) above MSL Standards NFPA 70, NFPA 75, NEC Article 645, 29 CFR 1910.36, 29 CFR 1910.306 Approvals UL, C-UL, CE EPO System Installation and Operation 17

Warranty and Service Limited warranty APC warrants the Emergency Power Off (EPO) System to be free from defects in materials and workmanship for a period of 2 years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. This warranty does not apply to equipment that has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser. Warranty limitations Except as provided herein, APC makes no warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. Some jurisdictions do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser. Except as provided above, in no event will APC be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of this product, even if advised of the possibility of such damage. Specifically, APC is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you specific legal rights and you may also have other rights, which vary according to jurisdiction. Obtaining service To obtain support for problems with your Emergency Power Off (EPO) System: 0 1. the serial number and date of purchase. 2. Contact Customer Support at the phone number on the back of this document. A technician will try to help you solve the problem by phone. 3. If you must return the product, the technician will give you a return material authorization (RMA) number. If the warranty expired, you will be charged for repair or replacement. 4. Pack the unit carefully. The warranty does not cover damage sustained in transit. Enclose a letter with your name, address, RMA number and daytime phone number; a copy of the sales receipt; and a check as payment, if applicable. 5. Mark the RMA number clearly on the outside of the shipping carton. 6. Ship by insured, prepaid carrier to the address provided by the Customer Support technician. 18 EPO System Installation and Operation

APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests. www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. www.apc.com/support/ Global support searching APC Knowledge Base and using e-support. Contact an APC Customer Support center by telephone or e-mail. Regional centers: Direct InfraStruXure Customer Support Line (1)(877)537-0607 (toll free) APC headquarters U.S., Canada Latin America Europe, Middle East, Africa (1)(800)800-4272 (toll free) (1)(401)789-5735 (USA) (353)(91)702020 (Ireland) Australia (61) (2) 9955 9366 China (86) (10) 8529 9888 India (080) 5737497 Local, country-specific centers: go to www.apc.com/support/contact for contact information. Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support. Entire contents copyright 2004 American Power Conversion. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC, the APC logo, and InfraStruXure are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions. All other trademarks, product names, and corporate names are the property of their respective owners and are used for informational purposes only. 990-1611B 08/2004 *990-1611B*