static filter systems Power Systems Camfil Farr - clean air solutions for turbomachinery

Similar documents
Clean air solutions for turbo machinery

DATA CENTRES. Camfil Farr Segment Brochure Data Centres Camfil Farr - Clean Air solutions

DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS

Reliability. The Essentials of Eliminating Downtime of your Electric Motor. Asset Management? Or, Maintenance Management, Re-branded?

ROTARY SCREW COMPRESSOR. RMD kw

i n d o o r a i r q u a l i t y I AQ EN 13779:2007 European standard Camfil Farr clean air solutions

Kompressoren. Oil Water Separators OWS

Camfil Farr Technical Services Bulletin

products 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN

Advantages Of A New And Advanced Nanofiber Coating Technology For Filtration Media Compared to The Electrospinning Process

ThermoStar Refrigeration Air Dryers

ThermoSorb Desiccant Dryers

Quick wins for energy savings in buildings

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES

GUIDELINE FOR GAS TURBINE INLET AIR FILTRATION SYSTEMS

White Paper: Free Cooling and the Efficiency of your Data Centre

Federation of European Heating, Ventilation and Air-conditioning Associations

FUNDAMENTALS OF GAS TURBINE ENGINES

Strong partners offer perfect solutions. Automatic filtration and maintenance of engine lubricating oil in diesel locomotives

Air Induction Systems

Energy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling

CIMAC Guideline

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

Calculating the cost of HVAC air filters

Refrigerated Air Dryers. Catalogue

Equipment Performance Monitoring

6 Crankcase Ventilation

Filter Media Technology Specially Formulated to Protect Gas Turbines, Compressors and Generators

State of the Art Energy Efficient Data Centre Air Conditioning

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

What You Don t See Is What You Should Look For

HVAC Design Requirements

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

A Review of Biomass Boiler Technologies. Fernando Preto CanmetENERGY, Natural Resources Canada

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

BRAZED PLATE INSTALLATION MANUAL

Performance Monitoring For Gas Turbines

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

Rotary screw compressors kw 5,5 7, , bar MODULO

Managing Heat Stress in Poultry

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

Frequently Asked Questions Generators

RPV - RP - RA air handling units

Redefining Spray Technology

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Industrial Power. SGT-800 Gas Turbine. Power Generation: (ISO) 47.5 MW(e) / 50.5 MW(e) / energy

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

GAS TURBINE PERFORMANCE UPGRADE OPTIONS

Offshore Substation. HVAC System. ETS-09 Rev. 2. technical standards. Dok Sag 09/1437

Tips for a Successful Diesel Retrofit Project

Refrigeration Air Dryers. Catalogue

O i l - B r i g h t I d e a s

Kompressoren. Adsorption Dryer AD

T U R B I N E G A S M E T E R

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Certification system of air filter quality (CAF mark)

SGT5-4000F Trusted Operational Excellence

DESIGN, OPERATION, AND MAINTENANCE CONSIDERATIONS FOR IMPROVED DRY GAS SEAL RELIABILITY IN CENTRIFUGAL COMPRESSORS

Data Centres A complete solution to noise control and acoustic packages

Innovative to the Core

Half the cost Half the carbon

February Service Division. Unrestricted Siemens AG All rights reserved.

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Trane CleanEffects. Patented technology. Superior performance. READ ONLY

COMMON EQUIPMENT FAILURES AND CAUSES. How breakdowns can impact the bottom line. A handy reference guide from Hartford Steam Boiler.

Introduction of the Solar Turbines Titan 250 Gas Turbine System

Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index

Which filter class for supply air is required in a typical HVAC system?

The Use of Exhaust Gas Recirculation (EGR) Systems in Stationary Natural Gas Engines. The Engine Manufacturers Association August 2004

How to Choose An Air Filter For Your Boat

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

Exhaust Scrubbers. What you need to know. Move Forward with Confidence

David Mezzacappa, P.E. SCS Engineers Contractor to U.S. EPA on LMOP

Chapter 12 Industrial Ventilation

Dehumidification Frequently Asked Questions

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Estimated emissions and CO2 savings deriving from adoption of in-place recycling techniques for road pavements

FORENSIC ENGINEERING ANALYSIS OF A COMBUSTION TURBINE COMPRESSOR BLADE FAILURE

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

Biomass Boiler House Best Practices. Irene Coyle & Fernando Preto CanmetENERGY

SENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Low Load Operational Flexibility for Siemens G-class Gas Turbines

Your oil can be saved!! Even when water is mixed

Technical Cleaning Ó

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Atlas Copco Quality Air Solutions. Compressed Air Filters

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.

industry revolves around

SUNON SPECIFICATION FOR APPROVAL

Rotary Screw Compressors SK Series

SGT-800 GAS TURBINE CONTINUED AVAILABILITY AND MAINTAINABILITY IMPROVEMENTS. Dr. Vladimir Navrotsky Lena Strömberg Claes Uebel

Rotary Screw Compressors UP-Series 4 & 5.5 kw

Transcription:

static filter systems Camfil Farr Power Systems Application brochure Power Systems Camfil Farr - clean air solutions for turbomachinery

static filter systems Static filter systems suitable for most land-based environments Air is vital to all combustion processes. Poorly filtered air can impair or damage essential parts in turbomachinery. Air containing solid particles, salt and other aggressive contaminants and aerosols can cause blockage and fouling, resulting in reduced performance, higher operating costs and expensive downtime. Contaminated process air can also lead to corrosion and erosion, causing damage to critical operational components and necessitating major repairs. Static filter systems are designed to clean inlet combustion- and ventilation air in installations with gas turbines, diesel engines and compressors in rural, urban and industrial environments. Highly efficient air filters help ensure the efficiency, the operating economy and the reliability of the process. Filter elements Our filter elements are specially developed for rotating machines. They are resistant to moisture, vibration and pressure surges. We have filter elements in many different filtration efficiency classes to provide the degree of protection required, combined with high dust-holding capacity and low pressure drop. The air filter s life depends on the air dust concentration in relation to the effective filter material used. To protect high-performance, sensitive machines and prolong both operating periods and accessibility, HEPA systems are often recommended. Low pressure drop in filters and other components saves fuel and cuts operating costs, thereby raising the installation s total efficiency. As a simple rule of thumb, if the filter area is increased by 50%, the filter s life increases by 100%. System features In addition to an optimized filter combination, the inlet system must be fitted with A suitable weather protection system. In some cases an anti-icing system and insect protection. Inlet air cooling is used to raise engine output in installations with high ambient temperatures. Note: A well designed air inlet system allows the turbomachinery to perform at its best. 2

Clean air essential for people and machines 3

static filter systems The Camfil Filter System increases efficiency and improves overall economy Economy There are many benefits of using an efficient air intake system. One main benefit is reliable operation with no unnecessary and costly downtime. Another is maintained high engine efficiency even in harsh environments with high dust load and fluctating humidity levels. Filters with a large surface, provides high dust loading capacity resulting in a low average pressure drop. This gives you the best possible operating economy. Environment Cleaner inlet air results in more efficient operation and lower fuel consumption, in turn leading to reduced carbon dioxide emissions. In addition, most of our filters are combustible. The filters are manufactured at the Camfil Farr Group s environmentally certified production facilities. Also our global presence puts us close to our customers, which reduces transport to site installations. Flexibility Camfil Farr Power Systems offers cost-effective, operationally reliable, highly flexible systems that can be fully customized to suit different environments and customer requirements. As part of the Camfil Farr Group, the world s largest developer and manufacturer of filters and clean air solutions, we offer a wide variety of products. 4

The cost of fouling When electricity is generated by gas turbines, the fuel cost typically represents 60% of the electricity selling price. Meanwhile, environmental requirements continue to increase. This is why many operators are now looking for better filtration systems to avoid fouling and keeping fuel consumption at a minimum. Axial compressor fouling is primarily caused by airborne submicron particles. Fouling changes the shape of both rotating and stationary vanes and results in a reduction of both mass flow and pressure ratio generated by the compressor. The net result of fouling is a reduction of power output and an increase in heat rate for a given combustor outlet temperature. Conversely, if an engine is not running at its temperature limit, a fouled Particle penetration Operation cost F7 F9 H10 H12 engine has to run hotter to produce a given output. A secondary effect of fouling is an increase in airfoil temperatures in the high pressure turbine, as fouling in the internal vane and blade cooling passages reduces heat transfer effectiveness and ultimately reduces the life of the hot section. The costs of fouling far exceed the cost of eliminating it, but since capital costs tend to weigh heavily in equipment purchase decisions, many gas turbines are equipped with inadequate inlet air filtration and the operator ends up paying many times more in extra operating costs. Many operators are now looking at possibilities to operate their gas turbines for longer periods of 2-3 years without shutdowns. Keeping the engine clean by preventing small particles from entering the air inlet system is one important step towards achieving this target. It means taking gas turbine filtration systems from the now typical medium efficiency technology to clean room technology or HEPA filtration. By going from the typical F8 grade to H12, penetration is dramatically reduced. For example, penetration on 0.4 micron particles is reduced from typically 25% for a F8 filter to less than 0.5% in a H12 filter a huge improvement which cuts fouling dramatically. In conclusion: the cost of clean air is not the cost of replacement filters it is how much energy the filters use during their working life at the desired efficiency. 0,1 Particle size 10 5

static filter systems A flexible system Weather protection (opt.) Hood Weather protection CamVane Prefilter Panel filter: G4 Prefilter Bag filter: F5, F6, F7 Selection guide The table provides recommendations for filters adapted to each environment. Filter combinations should be chosen according to the operating conditions at each facility. For detailed technical information, see separate data sheets. Air Inlet Protection Weather hood Snow hood Bird/Trash screen Insect/Bug screen CamVane Droplet separator Inlet air coolers Anti-icing systems Prefilter/Coalescer Hi-Cap G4 CamClose G4 R 30/30 GT G4 Cam-Flo / Hi-Flo F5-F7 Fine filters CamGT F7 CamGT F8 CamGT F9 Hepa filters CamGT H10 CamGT H12 Sofilair GT H10-H14 Rural countryside Large cities Industrial areas Coastal areas Tropical areas Artic areas = recommended = optional = not recommended/applicable 6

High eff. Filter: Cam GT F7, F8, F9 HEPA (opt.) Filter: Cam GT H10, H12 350 1,4 300 1,2 H12 Pressure drop Pa 250 200 150 100 50 HEPA (opt.) Filter: Sofilair H13, H14 F9 H10 G4 Cam Vane G5 F8 F7 1,0 0,8 0,6 0,4 0,2 Pressure drop inch wg (250 Pa = 1 inch) 0 0 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 1,4 Air flow m 3 /h 2000 2500 3000 3500 4000 4500 5000 Filter performance Air flow CFM A higher filter class means: A higher degree of separation. A cleaner engine. Longer service intervals. Higher availability. Lower operating costs. By going from the typical F8 grade to H12, penetration is dramatically reduced. For example, penetration on 0.4 micron particles is reduced from typically 25% for an F8 filter to less than 0.5% in an H12 filter a huge improvement which cuts fouling dramatically. Typical particle arrestance for clean filters during tests in accordance with EN779 2002 and EN 1822. The diagram shows the degree of separation for different particle sizes. Initial effiency % 110 100 90 80 70 60 50 40 30 20 10 F9 F7 H12 H10 F6 F8 F5 0 0,2 0,3 0,4 0,5 0,6 0,8 1 2 3 4 5 6 Particle size µm G4 7

On world standards...camfil Farr is the leader in clean air technology and air filter production. Camfil Farr conducts its own product development and R&D, and has worldwide local representation. Our overall quality goal is to develop, produce and market top-quality products and services that always exceed our customers expectations. We see our activities and products as an expression of our quality. To achieve overall high quality, it is necessary to establish an internal work environment where all Camfil Farr s employees can succeed together. This means an environment characterised by openness, confidence and always doing what s right for our customers. production: R&M, www.rochm.com, Photo: mats johansson/gothia, AND OTHERS www.camfilfarr.com info.gt@camfilfarr.com Camfil Farr Power Systems Europe: Americas: Middle East: Asia: Borås, Sweden tel: +46 33 17 85 00 Laval, Canada tel: +1 450 629 30 30 Dubai tel: +971 4 887 1796 India tel: +91 124 43 24 100 Bremen, Germany tel: +49 421 47886 0 tel: +1 800 976 93 82 Japan tel: +81 6361 38 36 (Tominaga & CO Ltd) Kreuzau, Germany tel: +49 2421 22 49 80 Brussels, Belgium tel: +32 2 68 80 520