Vane Type Mist Eliminators

Similar documents
Filtering Samples to On-Line Process Analyzers. Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers

Mist Elimination. Droplet Formation. Uses of Mist Eliminators. Equipment for gas-liquid separations and vapor flow conditioning.

Multi-pollutant control solutions for coal based power plants

HIGH EFFICIENCY NOZZLES FOR THE POLLUTION CONTROL INDUSTRY

Use of OpenFoam in a CFD analysis of a finger type slug catcher. Dynaflow Conference 2011 January , Rotterdam, the Netherlands

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance

Driven by knowledge, proven by results

5.2. Vaporizers - Types and Usage

Desuperheater Online Program Sizing Guidance

DESIGN, TESTING, AND OPERATING EXPERIENCE OF A SALTWATER DISPOSAL SYSTEM OIL-WATER SEPARATOR

MIST ELIMINATORS LIFE STORIES

TABLE OF CONTENT

Back End C2 Hydrogenation for Ethylene Production

Optimization Design for Sulfur Dioxide Flow Monitoring Apparatus in Thermal Power Plants Hao-wei Hu 1, a, Xue Yang 1, b and Xiao-wei Song 1, c

SEPARATING DUST PARTICLES USING AN AERODYNAMIC DEDUSTER

VAD. Variable Area Desuperheaters

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

Heat Pipe Selection Revision 12/04/2001

VAD Variable Area Desuperheaters

ENVIROENERGY SOLUTIONS. Presentation of APC and Wet Electrostatic Precipitation Technology

Pulverized Coal Pipe Testing and Balancing

INTRODUCTION. Fact Sheet: Air Pollution Emission Control Devices for Stationary Sources

PRINCIPLES OF FLUE GAS WATER RECOVERY SYSTEM

5.4 WET SCRUBBERS Particle Collection and Penetration Mechanisms Types of Wet Scrubbers

Chilled Water HVAC Systems

Mixing in the process industry: Chemicals Food Pharmaceuticals Paper Polymers Minerals Environmental. Chemical Industry:

Air Eliminators and Combination Air Eliminators Strainers

A Guide to Trouble-Free Cooling Towers

Optimizing Tank Cleaning Operations

No. Name Description Main input Data Main Output Data. cooling duty, process in/out temperature, inlet air temperature

Pros and Cons. of CFD and Physical Flow Modeling. A White Paper by: Kevin W. Linfield, Ph.D., P.E. Robert G. Mudry, P.E.

COMPOSITE MESH PAD (CMP) DRY SCRUBBERS III TM ENFORCER III

Domino VGS. Domino. Vertical Gravity Separator VGS. Oil Out. Clean Water Outlet. Oily Water In. Sludge Outlet. Everything Water PTY LTD

Guidelines for Precast Concrete Grease Interceptors

TEACHER BACKGROUND INFORMATION THERMAL ENERGY

WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )

Description & Working

Chapter Test A. Elements, Compounds, and Mixtures MULTIPLE CHOICE. chemically combined? MIXs2 a. element b. compound c. mixture d.

13.1 The Nature of Gases. What is Kinetic Theory? Kinetic Theory and a Model for Gases. Chapter 13: States of Matter. Principles of Kinetic Theory

Increasing Power Plant efficiency for safe wet stack Operation

Handling Corrosive or Abrasive Liquids

Critical Radius and Supersaturation. Condensed Water Molecules. Cloud Droplet Nucleation. Bubbles. Clouds. Change in number of liquid molecules

Atlas Copco Quality Air Solutions. Compressed Air Filters

In-Line Filters and Coalescers with Automatic Drains

Gas/Liquid Separation Technology. Sulzer Chemtech

Liquid Distributors. Liquid Redistribution. Liquid Distribution. INTALOX Distributors

Mechanical Seal Piping Plans

In-Line Air Separators

KINETIC MOLECULAR THEORY OF MATTER


2 MATTER. 2.1 Physical and Chemical Properties and Changes

TABLE OF CONTENT

Contamination Control

Pure Substances, Mixtures, and Solutions

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

Goulds AF. Axial Flow Pump

DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS

Cooling Tower Sidestream Filtration A Green, Proven Cost Reduction Technology

Putting a chill on global warming

Strong partners offer perfect solutions. Automatic filtration and maintenance of engine lubricating oil in diesel locomotives

2 1/2 Pipe. 40 = height. the gauge pressure inside the vessel from the gauge pressure at the nozzle inlet as shown:

Warm-Up 9/9. 1. Define the term matter. 2. Name something in this room that is not matter.

FLUID FORCES ON CURVED SURFACES; BUOYANCY

Sewage and Wastewater Odor Control Dr. Giancarlo Riva, Ozono Elettronica Internazionale, Muggio, Italy

Air Pollution and its Control Measures

Cartridge Filter Application Notes

Kompressoren. Oil Water Separators OWS

HELPFUL HINTS ON PREPARING COMPRESSED AIR

(Walter Glogowski, Chaz Shapiro & Reid Sherman) INTRODUCTION

6. Base your answer to the following question on the graph below, which shows the average monthly temperature of two cities A and B.

Radial-axial Radial mixing is based on the premise that the fluids to be mixed enter the mixer in the correct proportions simultaneously

Computational Fluid Dynamics (CFD) and Multiphase Flow Modelling. Associate Professor Britt M. Halvorsen (Dr. Ing) Amaranath S.

WASTEWATER TREATMENT OBJECTIVES

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

When the fluid velocity is zero, called the hydrostatic condition, the pressure variation is due only to the weight of the fluid.

CTour Simultaneous Removal of Dispersed and Dissolved Hydrocarbons in Produced Water John B. Sabey, VP Business Development, ProSep Technologies, Inc.

TR40 Sterilizing Filtration of Gases A comparison with TR26 Sterilizing Filtration of Liquids

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

Heterogeneous Homogenous. Mixtures; Solutions. Phases of matter: Solid. Phases of Matter: Liquid. Phases of Matter: Gas. Solid, Liquid, Gas

SECOND GRADE 1 WEEK LESSON PLANS AND ACTIVITIES

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Storm Drain Inlet Protection - IP

Automatic Self-Cleaning Strainers

GAS FUEL CLEAN-UP SYSTEM DESIGN CONSIDERATIONS FOR GE HEAVY-DUTY GAS TURBINES C. Wilkes GE Power Systems Schenectady, NY

Chapter 12 Industrial Ventilation

Liquid-Liquid Coalescer Design Manual


Medical Air Systems: Scroll

Filtration Guide. Introduction. Benefits of Clean Water

How does solar air conditioning work?

Scheduling Maintenance for Infiltration Basins and Trenches

Determination of a Chemical Formula

FLUE GAS DESULPHURIZATION

LECTURE 6: Fluid Sheets

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Chokes. Types Reasons Basics of Operations Application

Transcription:

Vane Type Mist Eliminators

2 Vane or baffle Type Mist Eliminator Air Water Soil Corporation offers a full range of air pollution control technologies, waste and primary water treatments and industrial fluids purification systems. The fluids purification system division is specialized in the design of mist eliminators, liquid-liquid separators, coalescers, solid-liquid separators, static mixers. Definitions: Mist and Spray Mistandspraycanbeincludedinthemainfamilyofaerosolthat are suspended particulate, either solid or liquid, which is slow to settle by gravity. The particle sizes is from the submicrometer range up to 10 to 20 μm. These mist eliminator types are widely used in industry to separate liquid droplets from gas streams. In all the applications where a contact between liquid and flowing gas is involved, tiny mist droplets are carried away with the gas. TYDE VANE type mist eliminators of AWS are specifically made to remove mainly liquid droplets together with solid particles from an air or gas stream. Aerosol particles diameter for different sources, μm Unlike filters, which hold particles indefinitely, TADE VANES mist eliminators of AWS separate fine droplets and drain the liquid away from the gas stream. GAS OUT Mists are fine suspended liquid dispersions usually resulting from condensation and ranging upward in particle size from around 0,1 μm. Spray refers to entrained liquid droplets. The droplets may be entrained from atomizing process (i.e. absorption towers). Size will range from the finest 10 μm uptoaparticlewhoseterminal settling velocity is equal to the entraining gas velocity (if some settling volume is provided). VANE SEPARATOR Evaporator ABSORBING LIQUID IN FGD scrubber Cooling tower Typical vertical flow VANE separator installed at top of a scrubber Typical spray size and example of sources

3 Typical droplet size removal Collection mechanism of VANE TYPE mist eliminators TIDE VANES have a wide open area which render them true candidates for removal of high liquid amounts combined with high gas flow rates. Due to their high resistance to fouling, they can work perfectly when in presence of sticky or insoluble solids. However, TIDE VANES show good removal efficiency when the mass of the droplets to be removed is in the range of 10 micron and larger. Below 10 micron they still show reasonable efficiency which is higher, the higher is the face gas velocity. Our process engineers are skilled to provide customers with all information regarding efficiency curves of our TIDE VANES for specific applications and installations. TIDE VANE mist eliminators of AWS are made of zig-zag baffles thatcausethemistladengastochange direction quickly as it flows through the oriented baffles or blades. The liquid droplets, due to their momentum, impact on the baffles and are separated from the gas flow as they are unable to follow the gas streamlines. TIDE VANE are inertial separators because liquid droplets are removed due to their inertial momentum. Particles which are too small (less than 5 micron in diameter) are therefore not to be considered as a good candidate for this type of mist eliminator. GAS OUT FIRST STEP: Mesh Coalescer SECOND STEP: Vane separator LIQUID DRAIN OVERFLOW For liquid particles size lower than 10 μm, AWS can engineer combined mist separators which foresee a coalescing stage followed by a separation stage, as illustrated in the above drawing. Incaseofupwardgasflowasintheabovepicture,collectedliquid droplets disengage from the bottom of the vanes as droplets are large enough to fall down through the rising gas. In the case of horizontal gas flow as shown below, the collected liquid droplets trickle down the vanes to a drain below.

4 Installation TIDE VANES can perfectly work both for vertical or horizontal flow depending on type of service. In vacuum pans and evaporators they are usually installed at the column top in horizontal position i.e. working for vertical flow. In cooler condensers and in compressed gas services, they are normally installed in vertical position i.e. working for horizontal flow. In horizontal flow (vertical position)the face gas velocity can be higher than vertical flow because the collected liquid flows down orthogonal to the gas direction thus reducing the possibility of liquid re-entrainment. Horizontal flow installation is therefore preferred where a smaller TIDE VANES area is needed to be accommodated inside vessels or drums with space limitations. Features The advantages of using vane type mist eliminators are the following: Capacity Due to their open geometry, these separators can work at higher face velocities as compared to wire mesh separators without causing any re-entrainment of liquid. In fact, the critical velocity, which is the velocity above which reentrainment occurs, is much higher and therefore these separators canhandlelargeamountsofgasandliquidloadswithoutgetting flooded. Resistance to plugging Due to their construction layout made by zig-zag baffles with open space among them, the resistance to fouling even in severe applications is guaranteed. Solids accumulation on baffles or blades canbeeasilywashedoutwiththeuseofspraynozzleswhichare located upstream or downstream the vane pack depending from the specific process. High efficiency TIDE VANE separator panel GAS OUT VANE SEPARATOR TIDE VANE mist eliminator panels in SS 304L Pressure drop LIQUID DRAIN Vane type mist eliminator in high pressure separator The main characteristic of vane type mist eliminators is their extremely low pressure drop which is mostly in the range of a few millimeters of water column. The pressure drop is proportional to the distance of the blades, to the gas face velocity, to the number of direction changes (passes) and to the gas density.

5 VANE packs from AWS Our TIDE VANE panels have been studied to accomplish several applications, namely: evaporators vacuum evaporators concentrators cooling towers scrubbers packedtowers cooler-condensers high pressure separators knockoutdrums FGD scrubbers TIDE VANE panels can be manufactured in different materials: carbon steel stainless steel special alloy steel P.V.D.F. Polypropylene Reinforced polypropylene Titanium GAS OUT VANE SEPARATOR TIDE VANE panels in SS 316L and in PP LIQUID DRAIN Typical installation in a K.O. drum evaporator The industry we serve includes: pulp and paper sugar food chemical and petrochemical geothermal power stations coal and oil power stations gas compression stations VANE SEPARATOR GAS OUT

Main office AWS Corp. srl Vicolo Scuri, 123 24059 Urgnano (BG) - ITALY Phone +39 035 4819906 / +39 035 6014844 Fax +39 035 19967687 info@awscorp.it - www.awscorp.it B04 VANES R03