MIST ELIMINATORS LIFE STORIES
|
|
- Morgan Merritt
- 8 years ago
- Views:
Transcription
1 MIST ELIMINATORS LIFE STORIES
2 8 th Mesa Redonda, Rd d Chile
3 THELIFEOFMESHPAD DEMISTERS 1. CORROSION OF METAL WIRES This Lewmet demister was removed for washing and there corrosion of one D section s mesh was found. There was an inlet pipe directly below the position of this section in the tower, with SO 3 vent vapour from an Oleum tank. The pipe was shut & the tank was fitted with our Becoflex BFCF vent system
4 THELIFEOFMESHPAD DEMISTERS 1. CORROSION OF METAL WIRES There is often a detrimental effect of ferrous sulphate falling down onto a demister from the central carbon steel exit duct above. If left like that corrosion of the small diameter wires can increase. As the corrosion will attack the whole circumference of the wire, the wire can disappear quickly.
5 THELIFEOFMESHPAD DEMISTERS 1. CORROSION OF METAL WIRES Sulphates and sulphuric acid left ignored in a meshpad during a shutdown, or during an outage where moist air can enter the tower, have a high risk of increasing corrosion as weak acid attacks the wires. In most European plants where metal mesh is used, 316L Stainless Steel lasts well. Alloy 20 and SX are examples of more corrosion resistant wire materials for non EU duty. We supplied SX wire demisters for the 3 Outotec Ma aden plants in 2009.
6 THELIFEOFMESHPAD DEMISTERS 2. HEAT SHRINKAGE OF PLASTIC WIRES Shrinkage of sides of sections of D.T. meshpad made in Halar E.C.T.F.E. material SO 3 effect on Halar E.C.T.F.E. Softeningand relaxing of HalarE E.C.T.F.E. CTFE mesh material layers all the formed crimp wave is gone
7 THELIFEOFMESHPAD DEMISTERS 2. HEAT SHRINKAGE OF PLASTIC WIRES Heat shrinkage of sides of sections of D.T. upper meshpad made in Hostaflon E.T.F.E. material + gaps filled with Halar E.C.T.F.E. material, which is discoloured dand damaged dby SO 3 attack SO3 damaged Halar E.C.T.F.E. wire melted onto packing Heat shrinkage of lower Hostaflon + PTFE fibre coalescer + blackened Halar material in gaps
8 THELIFEOFMESHPAD DEMISTERS 3. SOLIDS BLOCKAGE AND WASHING DAMAGE Sulphur sublimation in Smelter plant D.T. meshpad Sulphates Nitrosyl crystals in Spent Acid Regen plant D.T. meshpad
9 THELIFEOFMESHPAD DEMISTERS 3. SOLIDS BLOCKAGE AND WASHING DAMAGE Every time that a meshpad is washed it is at risk from damage during handling and poor refitting into the vessel. In this photo you can see a damaged section of demister with the grid obviously not fitted properly p at the end. This then affects mesh to mesh (or mesh to wall) seals Puerto Varas October
10 THELIFEOFMESHPAD DEMISTERS 3. SOLIDS BLOCKAGE AND WASHING DAMAGE
11 THELIFEOFMESHPAD DEMISTERS 3. SOLIDS BLOCKAGE AND WASHING DAMAGE Although metal mesh pads are generally resistant to rough handling, damage can be done if the fitters are not careful. As can be seen when aligning 2 sections on the right, a mesh tomesh seal will only be possible if the sections are over compressed when re fitted, leading to other gaps.
12 THELIFEOFMESHPAD DEMISTERS 4. MAINTENANCE SUGGESTIONS All meshpads are made with +/ 25mm space between adjacent section grids. Use simple U clips on the top grids when fitting, to act as a mesh compression guide. Angle the final meshpad sections in the remaining space using a thin metal sheet against the mesh sides ; push down on the ridge and slide the sections in place
13 THELIFEOFMESHPAD DEMISTERS 4. MAINTENANCE FRIENDLY DESIGN SUGGESTION Early versions of an externally removable meshpad used a traditional horizontal arrangement, with awkward, risky results when removing heavy, wet sections, high up a tower. The externally removable, Vertical meshpad design was developed between Begg Cousland and Outotec, and the new Noracid idchile plant features it.
14 THELIFEAND DEATH OF FIBRE BED MIST ELIMINATORS 1. CORROSION OF METAL FILTER STRUCTURES The wires of the inner and outer mesh cages of a fibre bed mist eliminator are the main victims of corrosive attack. The wire is corroded over the whole circumference, so a 2.5mm.5mmdia. wire survives < 1.25mm corrosion. The wires at the bottom of cages are the most at risk, from un drained acid / sulphates on the tubesheet for standing type, and residual acid in the fibre for all types
15 THELIFEAND DEATH OF FIBRE BED MIST ELIMINATORS 1. CORROSION OF METAL FILTER STRUCTURES The use of raised stool flanges (part of tubesheet or part of candle filter as shown), avoid these extra corrosion risks.
16 THELIFEAND DEATH OF FIBRE BED MIST ELIMINATORS 1. CORROSION OF METAL FILTER STRUCTURES Inspection from below did not show anything obvious.
17 THELIFEAND DEATH OF FIBRE BED MIST ELIMINATORS 1. CORROSION OF METAL FILTER STRUCTURES From above the sulphate deposits on the wall showed serious abnormality.
18 THELIFEAND DEATH OF FIBRE BED MIST ELIMINATORS 1. CORROSION OF METAL FILTER STRUCTURES The missing top part of one filter was then obviously the issue.
19 THELIFEAND DEATH OF FIBRE BED MIST ELIMINATORS 1. CORROSION OF METAL FILTER STRUCTURES The cage was corroded by localised weak acid formation, due to vent pipe inlet below this filter.
20 THELIFEAND DEATH OF FIBRE BED MIST ELIMINATORS 1. CORROSION OF METAL FILTER STRUCTURES Corroded hanging type candles (or the bits that remained of them) viewed at the distributor level. This Russian customer had decided to wash the tubesheet and filters with water.
21 THELIFEAND DEATH OF FIBRE BED MIST ELIMINATORS 1. CORROSION OF METAL FILTER STRUCTURES Corroded top flange (8mm) Corroded cage mesh Corroded bottom plate (8mm) Puerto Varas October
22 THELIFEAND DEATH OF FIBRE BED MIST ELIMINATORS 1. CORROSION OF METAL FILTER STRUCTURES High Velocity type candle filters from a D.T. in a plant that had been shutdown for some months due to the Financial Crisis. No preventive maintenance, washing / neutralising of the filters Retained H2SO4 in the filters and sulphates led to (random) weak acid corrosion of the cages The wire of the cage mesh was 3mm dia. Cage corroded here below the top plate
23 THELIFEAND DEATH OF FIBRE BED MIST ELIMINATORS 2. CORROSION OF FIBRES Corroded dglass fibre in Asian Ai Cu Smelter plant Carbon Fibre : Resistant to HF Brownian Diffusion efficiency Corroded glass fibre in European Cu Smelter plant
24 THELIFEAND DEATH OF FIBRE BED MIST ELIMINATORS 3. BLOCKAGE WITH SOLIDS AND WASHING DAMAGE Hanging candle filters blocked by sulphates Sublimed sulphur blocking the fibre 5 year old hanging candle filters blocked by insoluble solid dusts, with a new filter added.
25 THELIFEAND DEATH OF FIBRE BED MIST ELIMINATORS 3. BLOCKAGE WITH SOLIDS AND WASHING DAMAGE Washing mist eliminators is an obvious way of extending filter life and saving money on a new set. It is not always easy or quick, and can be expensive to do. Only wash when you really need to. Washing can involve risk of damage. Washing Guide available from Begg Cousland
26 THELIFEAND DEATH OF FIBRE BED MIST ELIMINATORS 3. BLOCKAGE WITH SOLIDS AND WASHING DAMAGE Only wash when you really need to. Washing can involve risk of damage. Although h these hanging filters look kdiscoloured d in the tower, when removed you can see that there is no serious surface solids. Washing without reason can lead to fibre damage and mishandling of the structures, which can finish a filter s life.
27 THELIFEAND DEATH OF FIBRE BED MIST ELIMINATORS 3. BLOCKAGE WITH SOLIDS AND WASHING DAMAGE The mist eliminator below was automatic removed for washing under a shutdown schedule. Unnecessary washing causes abnormal liquid load stress to the fibre, a risk to High Velocity fibres ThePD hd had only risen by 10% over 18 The lighter density fibre bd beds can also months so neither the PD nor the be damaged easily by too high water visible solids justify washing pressure & handling
28 THELIFEAND DEATH AND REBIRTH OF FIBRE BED MIST ELIMINATORS 4. MAINTENANCE COST SAVING SUGGESTION REPACKING STRUCTURES WITH NEW FIBRE BEDS / RECYCLING FLANGES Why leave re useable parts lying in a scrap heap because they are not able to be cleaned or have been damaged when being removed / washed. hd? Re cycle the structure by sending it to us for repacking in the USA, Italy or India. Alternatively re cycle only the top and bottom flange sets.
29 THELIFEAND DEATH AND REBIRTH OF FIBRE BED MIST ELIMINATORS 4. MAINTENANCE COST SAVING SUGGESTION REPACKING STRUCTURES WITH NEW FIBRE BEDS / RECYCLING FLANGES If a structure has this amount of damage and distortion, then it will not be possible to repack it. Cut off the top and bottom flanges and only return them to us. So save freight cost. So save fibre stripping time and cost. Those savings can off set the cost of a new set of cages welded to the returned flanges, and boxes.
30 EXTENDING THE MIST ELIMINATORS LIFE 1. COLLECTING INFORMATION Mist eliminators performance can be monitored by : Pressure Loss Stack Exit Appearance
31 EXTENDING THE MIST ELIMINATORS LIFE 1. COLLECTING INFORMATION Mist eliminators performance can be monitored by : Pressure Loss Acid Drainage
32 EXTENDING THE MIST ELIMINATORS LIFE 1. COLLECTING INFORMATION Mist eliminators performance can be monitored by : Pressure Loss Sludge Presence
33 EXTENDING THE MIST ELIMINATORS LIFE 1. COLLECTING INFORMATION Mist eliminators performance can be monitored by : Pressure Loss High Corrosion Rate
34 EXTENDING THE MIST ELIMINATORS LIFE 1. COLLECTING INFORMATION Mist eliminators performance can be monitored by : Pressure Loss Mist Sampling and / or Stick Test
35 EXTENDING THE MIST ELIMINATORS LIFE 2. UNDERSTANDING / INTERPRETING THE INFORMATION Stick Test result changes with gas volume? Stick Test result changed noticeably but the gas volume is the same?
36 EXTENDING THE MIST ELIMINATORS LIFE 2. UNDERSTANDING / INTERPRETING THE INFORMATION Stick Test result does not relate to stack plume? Droplets not very visible Spitting marks on & not seen at stack exit. ground may be Droplets only usually seen or car owners indicate reentrainment. t may find paintwork Check PD and trend. damaged & claim.
37 EXTENDING THE MIST ELIMINATORS LIFE 2. UNDERSTANDING / INTERPRETING THE INFORMATION An updated Troubleshooting Guide is available, as well as Guides to Shutdown Inspection, Stick Tests and to Mist Eliminator Design & Selection
38 MIST ELIMINATORS LIFE STORY FOOTNOTE OLEUM /SO3 TANK VENT SCRUBBER PACKAGE The 1 st use of our Becoflex Rotary Brush Scrubber in a H 2 SO 4 plant was in the UK, at the plant where a tank vent pipe led to corrosion of the candle filter shown. The customer stomerinstalled the Becoflex BFCF unit on top of the Oleum tank, spraying water onto the rotating brush to hydrolyse the SO 3 very effectively within the fan volute. All the H 2 SO 4 mist formation took place before the 2 nd stage candle filter, so there is an invisible exit.
39 MIST ELIMINATORS LIFE STORY FOOTNOTE OLEUM /SO 3 TANK VENT SCRUBBER PACKAGE The unit has its own recirculation tank to minimise the water effluent. The combination of dynamic contact between gas and liquid within the fan volute minimises unit size. A key feature is the suction generated by the rotating brush, which means that there is no need for a separate fan unit. The Becoflex is also self cleaning if any solid matter is entrained from the tank.
40 MIST ELIMINATORS LIFE STORY FOOTNOTE OLEUM /SO 3 TANK VENT SCRUBBER PACKAGE The 2 nd user of our Becoflex Rotary Brush Scrubber was in S. America, at the plant where the Oleum tank vent pipe led to the corrosion of the demister seen earlier. They also use the Becoflex to treat the fugitive vapours fromthe wagon loadingstation station. For further information ask for a copy of the Becoflex Brochure or a copy of the Data Questionnaire.
41 THEBEGG COUSLANDLIFESTORYLIFE STORY
Self Assessment Exercise
Self Assessment Exercise Read the following extract of supporting documentation for Permit Application for Galvos plc galvanising facility and the accompanying tables. Decide if the proposed control techniques
More informationCorrugated Tubular Heat Exchangers
Corrugated Tubular Heat Exchangers HEAT EXCHANGERS for the 21st CENTURY Corrugated Tubular Heat Exchangers (CTHE) Corrugated Tube Heat Exchangers are shell and tube heat exchangers which use corrugated
More informationA Guide to Trouble-Free Cooling Towers
A Guide to Trouble-Free Cooling Towers A basic understanding of cooling tower operation and maintenance will help keep a cooling water system running in top condition, year after year By David M. Suptic
More informationSECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
More information1-800-214-7716 www.midwestair.com COMPOSITE MESH PAD (CMP) DRY SCRUBBERS III TM ENFORCER III
1-800-214-7716 www.midwestair.com Bulletin ENF-06 MIDWEST AIR PRODUCTS CO., INC. COMPOSITE MESH PAD (CMP) DRY SCRUBBERS ULTRA-MACTACT TM wet scrubbers chrome (CMP) scrubbers mist eliminators (CMP) exhaust
More informationFILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS
FILTRATION SOLUTIONS Pharmaceutical Manufacturing filtration specialists Delivering quality filtration products As one of Europe s leading manufacturers of process filters, Amazon Filters is able to offer
More informationOptimizing Tank Cleaning Operations
Optimizing Tank Cleaning Operations Choosing the best way to thoroughly clean your tanks while minimizing use of costly chemicals, water and manual labor can be challenging. There are several things you
More informationSIGRAFLEX EMAIL. Properties. Applications
Multilayer sealing sheet, adhesive-free made from flexible graphite foil reinforced with stainless steel foils especially for use in PTFE envelope gaskets SIGRAFLEX EMAIL has been developed specially for
More informationSelect Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
More informationINSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR
INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR INTRODUCTION The Cirro MK 3 is a fully professional mist generator for producing sufficient airborne reflection particles to enable effect lighting to
More informationTYPICAL FIRE SAFETY INSPECTION VIOLATIONS
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to
More informationMulti-pollutant control solutions for coal based power plants
Multi-pollutant control solutions for coal based power plants By Luca Mancuso and Hans Janssen Content SOx control Wet Scrubbers Open towers Dual Flow Tray Technology Semi-Dry SDA CFB Scrubbers Dust control
More informationIn-Line Air Separators
Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI
More informationBest Basement Water Management Practices
Best Basement Water Management Practices Guide written by Patrick Sluss Sluss Construction (330) 224 5394 When a home owner is faced with a leaking basement there is a way to correct the problem and a
More informationEurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
More informationBest Practice in Boiler Water Treatment
Best Practice in Boiler Water Treatment Boiler Water Treatment Part 2 Internal Treatment Objectives of Internal Water Treatment 1 To control the level of total dissolved solids (TDS) within the boiler
More informationColonnade Security Pipe
Description: Round & Square downpipe formed from extruded 6060 T4 aluminium in various sizes (Ø83mm, Ø108mm, 83x83 mm & 108x108mm*) & supplied with a complete range of accessories i.e. Offsets, bends,
More informationSteam System Best Practices Condensate System Piping
Steam System Best Practices Condensate System Piping Summary The best method for improving steam system energy efficiency, reducing chemical costs, and reducing make-up water costs is to return the maximum
More informationScreen Melts. Introduction. Selecting Screen Material. Prefire Before Using. Spalling. Kiln Shelf
Introduction There are two terrific reasons for melting glass through screens. First because screen melts produce uniquely intricate patterns not possible any other way and second because it does it using
More informationWaterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries Introduction Wastewater of petrochemical industries and refineries contains high amounts of emulsified aliphatic or
More informationCooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
More informationBeautifully Traditional
Arcade 800mm Single Sliding Door Quadrant - nickel Arcade 900mm Single Sliding Door Quadrant - nickel ARC48 ARC49 INSTALLATION INSTRUCTIONS A www.arcadebathrooms.com IMPORTANT - Please read before installation
More informationUB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
More informationPackaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
More informationExternal Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902
External Wrapping of Steel Riser Pipe Case Study HJ3 CS200902 Introduction Refineries process a wide variety of petroleum products. As part of the process, they rely on cooling towers, which recycle water
More informationDesuperheater Online Program Sizing Guidance
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More information5.2. Vaporizers - Types and Usage
5.2. Vaporizers - Types and Usage 5.2.1. General Vaporizers are constructed in numerous designs and operated in many modes. Depending upon the service application the design, construction, inspection,
More informationHow To Clean Up A Reactor Water Cleanup
General Electric Systems Technology Manual Chapter 2.8 Reactor Water Cleanup System TABLE OF CONTENTS 2.8 REACTOR CLEANUP SYSTEM... 1 2.8.1 Introduction... 2 2.8.2 System Description... 2 2.8.3 Component
More informationReport on Sanctuary/Chancel Crawl Space Inspection. St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove. Project No.
Report on Sanctuary/Chancel Crawl Space Inspection St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove Project No. E112056 1. Background St. John in the Wilderness (SJITW) is considering
More informationThe soot and scale problems
Dr. Albrecht Kaupp Page 1 The soot and scale problems Issue Soot and scale do not only increase energy consumption but are as well a major cause of tube failure. Learning Objectives Understanding the implications
More informationPAAM COMMERCIAL PRIVATE LIMITED
METAL PACKAGING We at Paam Group have been providing vast range of packaging products to our customers based on their preferences, needs and specifications. We provide all the materials required in metal
More informationStructural Failures Cost Lives and Time
Structural Failures Cost Lives and Time Recent failures of storage bins, silos and other structures highlight the need to increase awareness of hazards associated with these structures. Since 2010, one
More informationInstallation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
More informationDRY CLEANING PLANTS REQUIREMENTS FOR INSTALLATION AND OPERATION
DEPARTMENT OF TRADE MERCHANT SHIPPING NOTICE NO.M.847 DRY CLEANING PLANTS REQUIREMENTS FOR INSTALLATION AND OPERATION Notice to Shipowners, Masters, Shipbuilders and Repairers 1. It has come to the notice
More informationShower and Floor Gullies Channel Drain and Tile Drain SECTION
Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions
More informationPuddle Flange. FRANK Puddle Flange
Puddle Flange FRANK Puddle Flange The problem Problems keep on occurring when connecting pipes during construction work. Pipes laid in the ground must be introduced into concrete walls or shafts. In many
More informationStandard Sleep Pod Side Entry Assembly Instructions
Standard Sleep Pod Side Entry Assembly Instructions www.podtime.co.uk enquiries@podtime.co.uk Working House Ltd How to assemble your pod Pod assembly onsite is a relatively simple exercise for two people
More informationWelding of Plastics. Amit Mukund Joshi. (B.E Mechanical, A.M.I.Prod.E)
Welding of Plastics Amit Mukund Joshi (B.E Mechanical, A.M.I.Prod.E) Introduction Mechanical fasteners, adhesives, and welding processes can all be employed to form joints between engineering plastics.
More informationUltipleat High Flow Filter System
Data Sheet PIUFFSENa Ultipleat igh Flow Filter System Description The Ultipleat igh Flow filter is a large diameter, coreless, single open ended, pleated cartridge with an inside-to-outside flow pattern.
More informationFacility Support Services
Facility Support Services The Precision Group has a breadth of experience delivering innovative, first class facility support service solutions to clients across the public and private sectors. Our expert
More informationKompressoren. Compressed Air Filters PF/DF/MF/SF/AF
Kompressoren Compressed Air Filters PF/DF/MF/SF/AF ALUP Filter For Compressed Air Purity Compressed air quality is related directly to the operating conditions of your compressor. Most compressor intake
More informationOIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: 31 3362-2400 w.tecni-ar.com.br
OIL-X EVOLUTION ENGINEERING YOUR SUCCESS. OIL-X EVOLUTION High Efficiency Compressed Air Filtration OIL-X EVOLUTION is a range of high efficiency compressed air filters consisting of coalescing filter
More informationThe Comprehensive Coatings Service Provider to Industry
Coating Systems Excellent Engineering Solutions The Comprehensive Coatings Service Provider to Industry 2 Coating Systems Weir Coatings specialises in the application of high performance protective linings
More informationFoundation Experts, LLC Specializes in Foundation Repair and Waterproofing
1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize
More informationSpray Booth Guideline
Department of Development Service 135 North D Street, Perris CA. 92570 Phone: (951) 443-1029 Fax: (951) 943-3293 PURPOSE The intent of this guideline is to provide the information necessary to ensure that
More informationGuidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters
Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters When water is heated, it naturally expands and allowance has to be made for this. Vented water heaters usually
More informationINTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
More informationDuring Various Aluminum Fabricating Operations
Guidelines for Handling Aluminum Fines Generated During Various Aluminum Fabricating Operations F-1 Guidelines for Handling Aluminum Fines Generated During Various Aluminum Fabricating Operations SCOPE
More informationRemoving Moisture within Large Double Glazed Windows
Removing Moisture within Large Double Glazed Windows Copyright: Max Cottrell www.mcottrell.co.uk This article gives the reasons and a method of removing accumulated moisture from double glazed windows,
More informationINJECTION MOULD DESIGN: MARPLEX PVC RESINS
MACHINE RECCOMENDATIONS PVC requires reciprocating screw injection moulding machine with a plasticising screw to produce homogeneous melt. It is recommended that a shot weight of the part should take two
More informationproducts 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN
products > Energy & Cost Saving Products OUTSIDE 35 C HUMIDITY 90% 22 º C Inside PROVIDED BY HEINEN & HOPMAN Heating Ventilation Air Conditioning Refrigeration HVAC energy & COST SAVING POSSIBILITIES A
More informationInstruction Manual. Image of SP-3015 & SP-3815. Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function
Important Safeguards READ ALL INSTRUCTIONS BEFORE USE. Instruction Manual Automatic Dispensing Hot Water Pot with Reboil Function Image of SP-3015 & SP-3815 SP-3015: 3.0L SP-3815: 3.8L SP-3017: 3.0L (Stainless
More informationHeat Exchanger Thin Film Foul Release Applications Corrosion Resistant Protective Coatings Grit Blast Surface Prep of Tubular Equipment
Heat Exchanger Thin Film Foul Release Applications Corrosion Resistant Protective Coatings Grit Blast Surface Prep of Tubular Equipment Non-Destructive Examination Heat Exchanger Mechanical Repair Services
More informationTEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE: WWW.WERMAC.ORG/
TEMA DESIGNATIONS OF HEAT EXCHANGERS Because of the number of variations in mechanical designs for front and rear heads and shells, and for commercial reasons, TEMA has designated a system of notations
More informationImportant Information
Single Door Quadrant Instruction Manual ESQ Important Information Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed according to
More informationRehabilitation of an Aging Concrete Reservoir Adit Tower
Rehabilitation of an Aging Concrete Reservoir Adit Tower Raymond S. Tombaugh, Senior Coatings Consultant KTA-Tator, Inc. and Mongkol Mahavongtrakul, P.E. Corrosion Control Contract Manager San Francisco
More informationSubpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
More informationStilling Well Recommendations
White Paper June 24, 2009 Stilling Well Recommendations This document describes general requirements for stilling wells used for radar tank gauging applications. Automation solutions for oil & gas, defense
More informationCalcite PH Nutralizer System
Calcite PH Nutralizer System Installation, Operation & Maintenance Manual Facts About Calcite Ph Neutralizers Calcite is a crushed and screened white marble media which can inexpensively be used to neutralize
More informationMGB Chrome Bumper Conversion
MGB Chrome Bumper Conversion Installation Instructions For 1974 1/2-1980 MGB This kit requires cutting, welding, and painting. Professional installation recommended. Note: Every MGB body is slightly different
More informationCHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS
CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,
More informationINSTALLATION OPERATIONPERATION MAINTENANCE
1-800-214-7716 www.midwestair.com SCRUB-MAN 06 INSTALLATION OPERATIONPERATION MAINTENANCE DO NOT STORE GRAY PVC SCRUBBERS IN DIRECT SUNLIGHT Wet Scrubbers MW-100, MW-200, MW-300 MW-100 FUME SCRUBBER PO
More informationLecture 6 - Boundary Conditions. Applied Computational Fluid Dynamics
Lecture 6 - Boundary Conditions Applied Computational Fluid Dynamics Instructor: André Bakker http://www.bakker.org André Bakker (2002-2006) Fluent Inc. (2002) 1 Outline Overview. Inlet and outlet boundaries.
More informationAtlas Copco Quality Air Solutions. Compressed Air Filters
Atlas Copco Quality Air Solutions Compressed Air Filters Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air for superior operational
More information1.2 Refrigerant Equipment. General
Part 1 General 1.1 Summary.1 Unless otherwise indicated, follow the standards below when specifying heating, ventilation and air conditioning (HVAC) work. These standards are not intended to restrict or
More informationSPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION 1. SCOPE Pipe subsoil drains shall be constructed in accordance with this specification and in conformity with the lines, grades and cross-sections shown
More informationGas-Fired, Residential Storage Type Water Heaters
Consulting, Resource, Education, Training, and Support Services for Home Inspectors A candle loses no light when it lights another candle. Gas-Fired, Residential Storage Type Water Heaters Most inspectors
More informationIH 17025 E Sigma Island 90
INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood
More informationTITANIUM FABRICATION CORP.
TITANIUM FABRICATION CORP. Titanium, Zirconium, and Tantalum Clad Construction General Considerations In many applications, particularly for large pressure vessels designed for high temperature and pressure,
More informationWATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
More informationseries 5350 5351 Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN 12165 CW617N
Pre-adjustable pressure reducing valves with self-contained cartridge - series CCREDITED ISO 9 FM ISO 9 No. CLEFFI / GB replaces / GB Function Pressure reducing valves are devices which, when installed
More information7. Chemical Waste Disposal Procedures
7. Chemical Waste Disposal Procedures Substances that Can and Cannot be Disposed of via Sink Drains or in Regular Solid Refuse Containers 1. It is prohibited to pour down a sink or floor drain, or place
More informationFree piston Stirling engine for rural development
Free piston Stirling engine for rural development R. Krasensky, Intern, Stirling development, r.krasensky@rrenergy.nl W. Rijssenbeek, Managing director, w.rijssenbeek@rrenergy.nl Abstract: This paper presents
More informationOptimization of Cleaning-In- Place (CIP) processes in bottled water industry
Optimization of Cleaning-In- Place (CIP) processes in bottled water industry V. Davy, Nestlé Waters MT AquaFit4Use Mid-Term Conference, Oviedo 15 th June 2010 Introduction CIP principles Cleaning-In-Place
More informationThe Suitability of CRA Lined Pipes for Flowlines Susceptible to Lateral Buckling SUT Global Pipeline Buckling Symposium, 23 24 February 2011
The Suitability of CRA Lined Pipes for Flowlines Susceptible to Lateral Buckling SUT Global Pipeline Buckling Symposium, 23 24 February 2011 Duncan Wilmot, Technical Manager, Cladtek International, Australia
More informationBRAZED PLATE INSTALLATION MANUAL
www.brazedplate.com BRAZED PLATE INSTALLATION MANUAL S.E.C. Heat Exchangers P.E.I. CANADA C0A 1A0 tel; 902-659-2424 fax; 902-659-2800 Table of Contents Description...2 Mounting position...3 Piping connections......3
More informationPRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133
More informationwww.steelformcatering.com
www.steelformcatering.com catering cat e r i n g We are specialized in the production and sub furniture of components for mechanical industry, sector for which we even furnish advice and collaborate in
More informationBPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap
1263050/6 IM-P126-07 ST Issue 6 BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation
More informationReplacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin americancraftsmanwindows.com Project Requirements: Failure to follow these instructions may void product
More informationDrive shaft, servicing
Volkswagen Passat B6 - Drive shaft, servicing Стр. 1 из 41 40-7 Drive shaft, servicing Drive shafts, overview I - Assembly overview: Drive axle with CV joint VL100 40-7, Drive axle with CV joint VL100,
More informationOil and Gas Pipeline Design, Maintenance and Repair
Oil and Gas Pipeline Design, Maintenance and Repair Dr. Abdel-Alim Hashem Professor of Petroleum Engineering Mining, Petroleum & Metallurgical Eng. Dept. Faculty of Engineering Cairo University aelsayed@mail.eng.cu.edu.eg
More informationStainless steel grade chart
Stainless steel grade chart ATLAS STEELS METAL DISTRIBUTION Chemical analysis (%) specified C Si Mn P S Cr Mo Ni Other Austenitic stainless steels 253MA S30815 0.05 1.1-2.0 0.8 0.040 0.030 20.0-22.0 10.0-12.0
More informationCurved Quadrant Instruction Manual
Curved Quadrant Instruction Manual Consumer Guarantee - Please make sure the purchaser/end user completes and returns the Guarantee card which is enclosed with this product. Failure to validate the Guarantee
More informationIMPORTANT INFORMATION
Curved Quadrant Instruction Manual CQ IMPORTANT INFORMATION Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed according to our guidelines.
More informationFlyMe Environmental impact assessment MHI/ 24-1-2007 Page 1(6) 2 Description and assessment of the Production process
Page 1(6) Fly Me CHAIR 1 Description and assessment of the Materials used in the Product 2 Description and assessment of the Production process 3 Description and assessment of the Surface Treatment Methods
More informationThe integrity evaluation of the reactor building at unit4 in the Fukushima Daiichi nuclear power station
The integrity evaluation of the reactor building at unit4 in the Fukushima Daiichi nuclear power station May 2012 Government and TEPCO s Mid-to Long Term Countermeasure Meeting Management Council Outline
More informationAsbestos Work Permit Procedures
These procedures are to be followed by all persons required to perform the following work: Handling, installation or removal of non-friable manufactured products known to contain asbestos provided no sanding,
More information[[ ;/LON/P&M/896/8/09 Date: 22-05-2013. Notice inviting quotation for Repairing heating system
[[ ;/LON/P&M/896/8/09 Date: 22-05-2013 TENDER NOTICE Notice inviting quotation for Repairing heating system 1. High Commission of India invites bids from the prospective Heating/Boilers Companies with
More informationDRAIN, WASTE AND VENT PLUMBING
Flow of waste in a drain system Solid and liquid waste flows in vertical pipes much differently than it does in horizontal systems. In near horizontal pipes we talked about maintaining the slope of the
More informationCooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
More informationRooflight INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary
More informationProfiles for floors of same height Cerfix Projoint
PROFILPAS S.P.A. VIA EINSTEIN, 38 35010 CADONEGHE (PADOVA) ITALY TEL. +39 (0)49 8878411 +39 (0)49 8878412 FAX. +39 (0)49-706692 EMAIL: INFO@PROFILPAS.COM s for floors of same height Cerfix Projoint Application
More informationSECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
More informationPRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major
More informationQualification Guide. BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation. BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation
Qualification Guide BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation BPEC 600/5270/3 - Level 2 NVQ Diploma in Plumbing and Heating BPEC
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL FIBERGLASS FUME SCRUBBER VERTICAL COUNTER CURRENT SERIES ECV Serial Number: Date Manufactured: Drawing Number: Tag Reference Project Sales Office: 2143 Convention
More informationHow to build a Pizza Oven in 4 days
How to build a Pizza Oven in 4 days Preparation day (slab) 1. Foundation 1500 deep x 1300 wide x 75mm deep Required 20 bags cement pre mix. If you already have a concrete base, you save this prep day DAY
More informationSchlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
More information