Building and Room Numbering Guidelines

Similar documents
Space and Door Numbering Standards (V1.0) Facilities Planning and Construction

Table of Contents. I Introduction 2. II Definitions & Area Calculation 2. III Room Numbering 7. IV Appendix A 9

Space Management Guidelines

Space Inventory Techniques

Applies to: All Employees within the Facilities Management Department (FMD)

LOUISVILLE FIRE PROTECTION DISTRICT 895 West Via Appia, Louisville, Colorado

Doughty Environmental Hygiene Associates

Chief Facilities Officer-Associate Vice President of Facilities

NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02

Office Space Standards and Guidelines

Part 2 Definitions for this Policy 2.1. ADA / TAS the Americans with Disabilities Act / Texas Accessibility Standards.

All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

Schematic Design: Quality Management Phase Checklist Project Phase Checklist Series

New York City Department of Buildings

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

DIVISION HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.

called and explain why it cannot be factored with algebra tiles? and explain why it cannot be factored with algebra tiles?

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)

Community Usher Handbook

3rd Annual Design Drafting Contest

Measuring Single Family Dwellings Town homes Condominium Units. P) ~ F)

SPECIFIC GUIDANCE FOR A HOUSE IN MULTIPLE OCCUPATION (HMO) CONVERTED ENTIRELY INTO SELF CONTAINED FLATS

DIVISION HARDWARE FORMAT 1. Technical specifications content and numbering system shall be based on 2004 CSI MasterFormat.

Firefighter Review. Instructor Guide

Scope: Communications and Electronic Systems addressed in this section include:

E000 CARSON TOWERS APARTMENTS ELECTRICAL INFORMATION SHEET OWNER STANDARD PROPERTY COMPANY CONSULTANT

NUMBER EFFECTIVE DATE. July 23, 2003

MILTON HALL BCO AWARDS 2014 THE WORKSPACE CONSULTANTS LLP

DESIGN REVIEW CHECKLIST Chapter 6 Special Consideration Design Guidelines

Elevation Certificates. Brad Loar FEMA Region IV

One of the fundamental design elements that every

17,280 square feet Overview:

INCIDENCE-BETWEENNESS GEOMETRY

Design Development Quality Management Phase Checklist Project Phase Checklist Series

FIRE AND LIFE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

I.S :2013 Fire Detection & Alarm Systems

Bold items are particular to the City of Euless

Work Space and Office Furniture Standards December 2014

Cleveland Clinic Drawing Standards. Version 2.2

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Hotel Accessibility Pack

Excel Database Management

Appendix P-0a: Suggested Implementation for All Performance Management Guidelines

Mechanical, Plumbing, and Fire Protection Conditions

I.S :2013 Fire Detection & Alarm Systems

University of Northern Iowa Design Documents Standards. October 2014

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

REQUIREMENTS FOR OBTAINING A THORNBURY TOWNSHIP, DELAWARE COUNTY PERMIT

Estimated Cost of Repair

PRODUCT AND ENGINEERING MANUAL

THE UNIVERSITY OF EDINBURGH. Paterson s Land.

CHAPTER 4 VENTILATION

Indiana Building Rehabilitation Standard

Electrical. This section applies to the design and installation of building power distribution systems.

Technical Assignment 2 TABLE OF CONTENTS

San Diego Convention Center Floor Plans

Page 4 of 17. Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology.

Schedule A. Civic Addressing Policy. of By-Law

Fraternity and Sorority House Fire Safety

SYSTEMWIDE REQUIREMENTS

SYSTEMS OF EQUATIONS AND MATRICES WITH THE TI-89. by Joseph Collison

ADDRESSES AND HOUSE NUMBERS

Segreti Design Scope of Interior Design Services

Overview of Hotel Fire Safety Requirements

Smoke Detector/Carbon Monoxide Detector Inspections

University Design Standard. Fire Alarm Systems

New York City Department of Buildings

SUMMARY OF ASBESTOS CONTAINING MATERIAL IN BUILDINGS AND BULK SAMPLE ANALYSIS

Excerpts from the Canadian National Building Code (NBC)

City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address

Department: Manager: Safety Coordinator: Date:

Effective Use of Two Stage Alarms & Voice Communication Systems

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

HOW TO STORE MORE IN LESS SPACE and

POINT UNIVERSITY CAMPUS SECURITY Emergency Response Plan

VAV Laboratory Room Airflow The Lowdown on Turndown

October 30, Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr.

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

National Flood Insurance Program Insurance Agent s Lowest Floor Guide

Fire Alarm Systems Requirements by Occupancy Type

Oliver House City Road, EC1. Design & Access Statement Addendum Oliver House

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Basic Excel Handbook

Foundation Evaluation Report for PROPERTY ADDRESS Houston, Texas August 30, Prepared for:

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R

Transcription:

1 of 5 Building and Room Numbering Guidelines GENERAL INFORMATION The primary function of room numbering is to serve as a wayfinding tool for building users. Room numbers also serve as a method of identifying each space for planning, scheduling, and other operational purposes. The following numbering conventions have been developed based upon nationally accepted industry standards specifically for Case Western Reserve University buildings and should be followed as closely as possible throughout all university facilities for the purpose of standardizing room numbers. Questions regarding building and room numbering guidelines should be directed to the University Space Administrator within the department of Campus Planning and Facilities Management. NEW BUILDINGS, ADDITIONS, AND RENOVATIONS New buildings shall implement these standards as closely as possible. All numbering of buildings, floors, and individual rooms shall be coordinated through the University Space Administrator within the department of Campus Planning and Facilities Management. Renovations and additions to existing buildings will initiate a review of the existing numbering system and a determination will be made to extend or abandon current numbering. An entire building, entire floor, entire suite, or segments of these may be renumbered to implement university standards. If the existing numbering system is used, existing room numbers shall not be duplicated. All numbering and/or renumbering of buildings, floors, suites, and individual rooms shall be coordinated through the University Space Administrator within the department of Campus Planning and Facilities Management. BUILDING IDENTIFICATION NUMBERS Each separate structure is given a unique building identification number. Building identification numbers are derived from a grid overlaid on the campus map and determined based upon the building s location. Whenever possible, building identification numbers should not be re-issued after building demolition. ROOM NUMBERS These guidelines have been created with the intention of creating a floor and room numbering scheme for each building that is structured so that numbers flow through the building, and campus-wide, in a consistent, comprehensible, and user-friendly pattern. Questions regarding building and room numbering guidelines should be directed to the University Space Administrator within the department of Campus Planning and Facilities Management. All accessible spaces with a minimum three foot ceiling height are required to have room number assignments. Each room shall have only one number, regardless of the number of doors entering into it.

2 of 5 Each room number within a building must be unique. Room numbering shall generally commence from the main entrance, or what is perceived as the main entrance, and proceed clockwise. The same room numbering sequence should be used on all floors within the same building. Room number systems on all floors should be similar to the greatest extent possible, even when floor plans are significantly different. All room numbers shall progress sequentially. Lower room numbers should be at one end of the building and higher room numbers at the other end of the building. Buildings with only one dividing corridor shall flow in an ascending order from one end of the building to the other. Even room numbers should be on one side of the primary hallway and odd room numbers on the other in so far as possible. Numbering shall cross the corridor, not go all the way around the outside, then all the way around the inside. In buildings with a more complex corridor system, numbers shall flow in an ascending order, in a clockwise direction from the main entrance or similar location such as an elevator lobby. Room numbers on one side of a corridor may be skipped in order to maintain succession with the room numbers on the opposite side of the corridor. Rooms in similar locations on different floors shall have similar room numbers so that room numbers are coordinated on a vertical basis (stacked) as well as a horizontal basis throughout the entire building. To the greatest extent possible, without creating other inconsistencies, rooms with the same digits in the last positions shall be located in the same position in the building. Thus, 01, 101, 201, etc. occur in a vertical stack. Room numbers shall be assigned to reasonably allow for renovations. Rooms shall be numbered in such a manner that, should renovations occur in the future, intervening numbers will be available for room assignments (especially where larger rooms are built that may be subdivided into smaller rooms at some time in the future). Sufficient numbers shall be reserved to allow for large spaces to be divided into standard size office spaces. The first two digits of a room number indicate the floor on which the room is located. Thus, 0101 is located on the first floor, 0301 is located on the third floor, and 1001 is on the tenth floor. Floors below-ground level will be preceded with 0B or SB. 0G shall only be used when partial sections of the building are underground. All room numbers contain seven digits in the University Space Inventory Database (0B01000, 0101000, 0201A00, 0301B20), although room signage does not typically reflect empty placeholders (01, 101, 201A, 301B2). Suites Alphabetic suffixes shall be used for rooms that can only be entered from within another room, such as in a suite of offices. Suffix letters are assigned in the order rooms are encountered and in the same clockwise direction as the overall numbering sequence beginning from the main entry. All interior rooms accessed from a primary room have an alphabetic character following the primary room number ( 0300A, 0300B, 0300C, etc.). A

3 of 5 secondary interior room shall have a single digit following the alphabetic character of the first level interior room ( 0300A1, 0300A2, etc.). All interior rooms do not require signage. * Alpha characters I and O should never be used. Large open offices with lab benches and cubicles shall be numbered in the same manner as rooms within a suite using the whole number of the room the cubicle resides followed by an alpha suffix ( 0101A, 0101B, 0101C, etc.). Areas with more than 25 (skipping I and O ) continue with a double alpha starting with AA ( 0101AA, 0101AB, 0101AC, etc.). Cubicles or benches located within rooms numbered with an alpha suffix shall number the cubicles using the room number followed by a numerical character ( 0101T1, 0101T2, 0101T3, etc.) NON-ASSIGNABLE SPACES All non-assignable rooms including bathrooms, corridors, stairwells, elevators, janitor closets, and mechanical and electrical rooms with a minimum height of 3 feet, shall be assigned a room number. All rooms do not require signage. Room numbering for corridors, stairwells, and elevator hoist ways are for record and drawing designation only and should not be reflected on building signage. Non-assignable spaces in similar locations on different floors shall be assigned similar room numbers so that room numbers are coordinated on a vertical basis (stacked) as well as a horizontal basis throughout the entire building to the extent possible. Thus, 01ST001, 02ST001, 03ST001, etc., occur in a vertical stack. Corridors Corridors are assigned room numbers beginning with the appropriate floor level followed by C. The main corridor is the first number for that floor s sequence. 01C010 is the main corridor on the first floor. Continuous corridors, regardless of length or configuration, carry one number. If a corridor is sectioned by doors, each sectioned length is assigned an alpha suffix. The main corridor on the first floor sectioned in three parts is numbered 01C0100, 01C01A0, and 01C01B0. Sectioned corridors are numbered in a clockwise direction beginning from the main entry. Main floor vestibules are considered a section of the main corridor and are numbered in the sequence. C: Corridor Numbered as: (01C010 01C990, 02C010 02C990, etc.) Stairwells Stairwells are assigned room numbers beginning with the appropriate floor level followed by ST according to relative importance and then sequentially in a clockwise direction, usually beginning from the main entry. ST: Stairwell Numbered as: (01ST001 01ST099, 02ST001 02ST099, etc.)

4 of 5 Elevators Each elevator on campus is assigned an identification number by the Customer Service department within Campus Planning and Facilities Management. The elevator identification number is assigned based upon the sequence elevators enter into the inventory. Elevator identification numbers shall not be re-issued after elevators are removed from service. Elevator hoist ways are assigned room numbers beginning with the appropriate floor level followed by EL and the appropriate elevator inventory number. EL: Elevator Numbered as: (0BEL069, 01EL069, 02EL069) FLOOR DESIGNATIONS The first two digits of a room number shall indicate the floor on which the room is located. 0102 is located on the 1 st floor, 0515 is located on the 5 th floor, and 1023A7 is located on the 10 th floor. Floors below grade will be preceded with B and/or SB. B01 is located in the basement. SB33 is located in the sub-basement. G may be used when partial sections of the building are underground. G23 is located on the ground level. Floor levels 1 through 9 are represented with two digits in the space inventory system (01, 02, 03, etc.), but building signage should not be created in this manner. Single level buildings shall be numbered 100 199. Multi-level buildings shall use the following room numbering structure: 3: Third level above grade, etc. Numbered as: 300-399 2: Second level above grade. Numbered as: 200-299 1: First level substantially above grade. Numbered as: 100-199 * Existing buildings may have this level designated as G numbered as: G01 G99 G: First level above grade. Numbered as: G01 - G99 * Ground is only to be used in buildings with at-grade entries that occur at different levels of the building, using 1 and G in descending order. B: First level fully below grade. Numbered as: B01 - B99 SB: Second level below grade. Numbered as: SB01 SB99

5 of 5 M: Mezzanine Numbered as: M01 - M99 * In existing buildings only - All mezzanines, attic floors, and penthouse levels should be numbered as whole floors. RENUMBERING PROCESS All renumbering of buildings, floors, suites, and individual rooms shall be coordinated through the University Space Administrator within the department of Campus Planning and Facilities Management working with the appropriate departments and staff to ensure changes occur with the least amount of disruption and addressing all appropriate operational and safety concerns. * Conduct a review of the existing building conditions. * If necessary, develop a numbering plan for the entire building. All buildings should anticipate future renovations and have renumbering plans in place. * Working with the department of Planning, Design & Construction and Marketing and Communications to ensure university signage standards are followed, review current signage and obtain quotes for all levels of implementation; single room, entire suite, entire floor, and entire building. Do not overlook directory and elevator signage. * Determine the appropriate level of action based on current building wayfinding conditions, current renovation project, overall impact, and associated costs. * Alert building occupants, facility managers, safety personnel, and Registrar (as needed) via email and general posting throughout the facility including conversion dates and contact information for questions. * The preferred time to implement renumbering is during the completion of a renovation project, over the weekend, or during a holiday period. * Installation of the entire program should occur at one time to avoid confusion. * Create and share a conversion sheet that identifies old and new in advance of implementation. Leave in prime areas (elevator lobbies) several weeks after implementation.