National Flood Insurance Program Insurance Agent s Lowest Floor Guide
|
|
|
- Erin Walton
- 10 years ago
- Views:
Transcription
1 National Flood Insurance Program Insurance Agent s Lowest Floor Guide
2 Insurance Agent s Lowest Floor Guide PUTTING IT INTO PERSPECTIVE Sections A and C of the 2009 Elevation Certificate provide fields for entering numerous measurements that the surveyor must record in completing an elevation survey. This data will be used to not only help insurance agents accurately rate a flood insurance policy, but also assist FEMA and the local communities with their floodplain management compliance issues. The 2009 Elevation Certificate does not specifically identify the Lowest Floor Elevation that must be used for rating purposes. Based upon your knowledge of the rules and regulations of the National Flood Insurance Program, you must make the final determinations regarding which elevation should be used to accurately rate the policy and calculate the premium. This guide must be used in conjunction with information provided on the Flood Insurance Application form. This guide will provide you with some helpful information and hints. WHERE TO START The following are some suggested guidelines for interpreting the elevation information in Section C: STEP 1: Review the Elevation Certificate. Find the referenced Building Diagram Number in Section A, Item A7. This diagram number refers to one of the building diagrams located on Instructions Pages 7-9 of the Elevation Certificate. STEP 2: Once the correct building diagram has been determined, review the data contained in Section C, Item C2 of the Elevation Certificate. The circled letters and numbers on the building diagram correspond to the elevations entered in Items C2. a-h in Section C, Item C2. Check the Lowest Floor Guide found on the inside of this brochure as well as in the Flood Insurance Manual. STEP 3: Review the Elevation in. If the elevation in is lower than the elevation in Item C2.f, then you have a building with a basement. The correct lowest floor elevation rating will be (Building Diagrams 2, 4, or 9). For Building Diagrams 1A, 1B, and 3, if is higher than C2.f, the building is slab on grade, or a WHERE TO GET HELP walkout first level. Rate as no basement and use Item C2.a as the lowest floor elevation for rating. If Item C2.c is given, and the property is in a V Zone, Item C2.c will be the correct lowest floor elevation for rating if there are no enclosures (Building Diagram 5). If Item C2.c is higher than, then you have an elevated building with enclosure(s) below the elevated level. Use Item C2.c as the lowest floor elevation for rating V Zones if the enclosure is less than 300 sq. ft., the walls are breakaway, and machinery and equipment are elevated at or above the BFE. Otherwise use the bottom of if the enclosure is 300 sq. ft. or greater, the walls are supporting walls, or machinery and equipment are below the BFE and an enclosure of any size exists (Building Diagram 6). IMPORTANT HINT: If Item A8 and/or Item A9 shows flood openings, and the openings are adequate for the square footage of the enclosed area, then you have an elevated building with proper venting. The lowest floor elevation for rating is Item C2.b, top of the next higher floor, as long as the building is not located in a V Zone (Building Diagrams 7 and 8). The Lowest Floor Guide will assist you in determining the lowest floor for rating purposes for the majority of your business. However, if you are unable to make the determination, contact your WYO Company underwriting staff or, for NFIP direct policies, the NFIP Servicing Agent underwriting department for assistance.
3 Lowest Floor Guide for Zones A, AE, A1-A30, AH, AR, AR Dual BUILDING DIAGRAM #1A All slab-on-grade single- and multiple-floor buildings (other than split-level) and high-rise buildings, either detached or row type Lowest Floor for Rating: Top of slab or lower attached garage if it has Distinguishing Feature: The area below the elevated floor is open, with walls. No obstructions below the elevated floor. no obstruction to flow of floodwaters (open lattice work and/or insect screening is permissible). or Item C2.d (if structure has attached garage) BUILDING DIAGRAM #5 Lowest Floor for Rating: Lowest elevated floor machinery and equipment below BFE unless the garage is properly vented BUILDING DIAGRAM #1B Lowest Floor Guide for Zones A, AE, A1-A30, AH, AR, AR Dual All raised slab-on-grade or slab-on-stem-wall-with-fill single- and multiple-floor buildings (other than split-level) and high-rise buildings, either detached or row type (e.g., townhouses); with or without attached garage. Lowest Floor for Rating: Top of slab or lower attached garage if it has machinery and equipment below BFE unless the garage is properly vented BUILDING DIAGRAM #6 walls with full or partial enclosure below the elevated floor. either partially or fully. In A Zones, the partially or fully enclosed area below the elevated floor is with or without openings** present in the walls of the enclosure. Lowest Floor for Rating: Lowest elevated floor or top of bottom floor if or Item C2.d (if structure has attached garage) conditions in the Flood Insurance Manual are met BUILDING DIAGRAM #2 All single- and multiple-floor buildings with basement (other than split-level) and high-rise buildings with basement, either detached or row type or Item C2.b BUILDING DIAGRAM #7 Lowest Floor for Rating: Top of basement floor either partially or fully. In A Zones, the partially or fully enclosed area below the elevated floor is with or without openings** present in the walls of the enclosure. All buildings elevated on full-story foundation walls with a partially or fully enclosed area below the elevated floor. This includes walkout levels, where at least one side is at or above grade. The principal use of this building is located in the elevated floors of the building. Lowest Floor for Rating: Lowest elevated floor or top of bottom floor if conditions in the Flood Insurance Manual are met BUILDING DIAGRAM #3 Distinguishing Feature: The bottom floor (excluding garage) is at or above All split-level buildings that are slab-on-grade, either detached or row type or Item C2.b BUILDING DIAGRAM #8 ground level Lowest Floor for Rating: Top of slab Distinguishing Feature: The area below the first floor is enclosed by solid All buildings elevated on a crawlspace with the floor of the crawlspace at or above grade on at least one side, with or without attached garage. or partial perimeter walls. In A Zones, the crawlspace is with or without openings** present in the walls of the crawlspace. Lowest Floor for Rating: Next higher floor or top of bottom floor if conditions in the Flood Insurance Manual (Lowest Floor Determination) for A zones are met BUILDING DIAGRAM #4 All split-level buildings (other than slab-on-grade), either detached or row type Lowest Floor for Rating: Top of slab (basement floor) or Item C2.b BUILDING DIAGRAM #9 Distinguishing Feature: The bottom (crawlspace) floor is at or below All buildings (other than split-level) elevated on a subgrade crawlspace with or without attached garage. ground level (grade) on all sides.* (If the distance from the crawlspace floor to the top of the next higher floor is more than 5 feet, or the crawlspace floor is more than 2 feet below the grade (LAG) on all sides, use Diagram 2.) Lowest Floor for Rating: Top of subgrade crawlspace BUILDING DIAGRAMS Lowest Floor Guide for Zones AO and A (without Estimated BFE) Distinguishing Feature: All buildings or Item C2.b Lowest Floor for Rating: Difference between the top of the bottom floor and highest adjacent grade Use the measurement provided in Item E1. If the top of the bottom floor is below the highest adjacent grade, show this difference as a negative number on the application. For buildings similar to diagrams 6-9 with proper openings, use the measurement provided in Item E2. **An opening is a permanent opening that allows for the free passage of water automatically in both directions without human intervention. Under the NFIP, a minimum of two openings is required for enclosures or crawlspaces. The openings shall provide a total net area of not less than 1 square inch for every square foot of area enclosed, excluding any bars, louvers, or other covers of the opening. Alternatively, an Individual Engineered Flood Openings Certification or an Evaluation Report issued by the International Code Council Evaluation Service (ICC ES) must be submitted to document that the design of the openings will allow for the automatic equalization of hydrostatic flood forces on exterior walls. A window, a door, or a garage door is not considered an opening; openings may be installed in doors. Openings shall be on at least two sides of the enclosed area. If a building has more than one enclosed area, each area must have openings to allow floodwater to directly enter. The bottom of the openings must be no higher than 1 foot above the higher of the exterior or interior grade or floor immediately below the opening. For more guidance on openings see NFIP Technical Bulletin 1.
4 Lowest Floor Guide for Zones V, VE, V1-V30 BUILDING DIAGRAM #1A All slab-on-grade single- and multiple-floor buildings (other than split-level) and high-rise buildings, either detached or row type Lowest Floor for Rating: Bottom of slab Lowest Floor Guide for Zones V, VE, V1-V30 BUILDING DIAGRAM #5 Distinguishing Feature: The area below the elevated floor is open, with no walls. No obstructions below the elevated floor. obstruction to flow of floodwaters. Insect screening is permissible, as are wooden or plastic lattice, slats, or shutters if at least 40 percent of their area is open. Maximum thickness is ½ inch for lattice, 1 inch for slats or shutters. Any machinery or equipment below the lowest elevated floor must be at or above the BFE. Lowest Floor for Rating: Bottom of lowest horizontal structural member Item C2.c. BUILDING DIAGRAM #1B All raised slab-on-grade or slab-on-stem-wall-with-fill single- and multiple-floor buildings (other than split-level) and high-rise buildings, either detached or row type (e.g., townhouses); with or without attached garage. Lowest Floor for Rating: Bottom of slab BUILDING DIAGRAM #6 walls with full or partial enclosure below the elevated floor. either partially or fully. Lowest Floor for Rating: Bottom of lowest horizontal structural member, or bottom of slab if conditions in the Flood Insurance Manual are met or Item C2.c.*** BUILDING DIAGRAM #2 All single- and multiple-floor buildings with basement (other than split-level) and high-rise buildings with basement, either detached or row type BUILDING DIAGRAM #7 either partially or fully. Lowest Floor for Rating: Bottom of slab (basement floor) Lowest Floor for Rating: Bottom of slab (lowest floor) BUILDING DIAGRAM #3 Distinguishing Feature: The bottom floor (excluding garage) is at or above.*** All split-level buildings that are slab-on-grade, either detached or row type ground level BUILDING DIAGRAM #8 Distinguishing Feature: The area below the first floor is enclosed by solid Lowest Floor for Rating: Bottom floor All buildings elevated on a crawlspace with the floor of the crawlspace at or above grade on at least one side, with or without attached garage. or partial perimeter walls. Lowest Floor for Rating: Bottom of slab (lowest floor) BUILDING DIAGRAM #4 All buildings elevated on full-story foundation walls with a partially or fully enclosed area below the elevated floor. This includes walkout levels, where at least one side is at or above grade. The principal use of this building is located in the elevated floors of the building..*** All split-level buildings (other than slab-on-grade), either detached or row type garage) is below ground level (grade) on all sides. Buildings constructed above crawlspaces that are below grade on all sides should also use this diagram.* BUILDING DIAGRAM #9 Distinguishing Feature: The bottom (crawlspace) floor is at or below ground level (grade) on all sides.* (If the distance from the crawlspace to the top of the next higher floor is more than 5 feet, or the crawlspace floor is more than 2 feet below the grade (LAG) on all sides, use Diagram 2.) Lowest Floor for Rating: Bottom of slab (basement floor) Lowest Floor for Rating: Bottom of subgrade crawlspace All buildings (other than split-level) elevated on a subgrade crawlspace with or without attached garage.. and Item C2.b. ***Use Item C2.c if available; otherwise subtract 12 inches from for one-to-four family residences. For buildings other than one-to-four family residences subtract 18 inches from. ***Use Item C2.c if available; otherwise subtract 12 inches from for one-to-four family residences. For buildings other than one-to-four family residences subtract 18 inches from.
5 F-441 (7/09)
LOWEST FLOOR GUIDE I. LOWEST FLOOR DETERMINATION
This section is to be used as a guide for identifying the lowest floor for rating buildings being considered for coverage under the National Flood Insurance Program. I. LOWEST FLOOR DETERMINATION The following
Elevation Certificates. Brad Loar FEMA Region IV
Elevation Certificates Brad Loar FEMA Region IV What is the purpose of the Elevation Certificate? The Elevation Certificate is an important administrative tool of the National Flood Insurance Program (NFIP).
April 2, 2009. Write Your Own (WYO) Company Principal Coordinators and NFIP Servicing Agent
U.S. Department of Homeland Security 500 C Street SW Washington, DC 20472 W-09020 April 2, 2009 MEMORANDUM TO: Write Your Own (WYO) Company Principal Coordinators and NFIP Servicing Agent FROM: SUBJECT:
LOWEST FLOOR GUIDE I. LOWEST FLOOR DETERMINATION. Previous Section Table of Contents
Previous Section Table of Contents Next Section This section is to be used as a guide for identifying the lowest floor for rating buildings being considered for coverage under the National Flood Insurance
NFIP LOWEST FLOOR GUIDE ABRIDGED
NFIP LOWEST FLOOR GUIDE ABRIDGED National Flood Insurance Program SCROLL DOWN 1 NFIP LOWEST FLOOR GUIDE QUICK REFERENCE This is an abridged version of the 2013 Flood Insurance Manual Lowest Floor Guide.
LOWEST FLOOR GUIDE I. LOWEST FLOOR DETERMINATION
Previous Section Main Menu Table of Contents Next Section This section is to be used as a guide for identifying the lowest floor for rating buildings being considered for coverage under the National Flood
SPECIFIC RATING GUIDELINES
NATIONAL FLOOD INSURANCE PROGRAM SPECIFIC RATING GUIDELINES April 2015 FEDERAL EMERGENCY MANAGEMENT AGENCY FEDERAL INSURANCE AND MITIGATION ADMINISTRATION RISK INSURANCE DIVISION UNDERWRITING BRANCH This
LOWEST FLOOR GUIDE I. LOWEST FLOOR DETERMINATION
LOWEST FLOOR GUIDE This section is to be used as a guide for identifying the lowest floor for rating buildings being considered for coverage under the National Flood Insurance Program (NFIP). I. LOWEST
Agenda. Presenter. The Current Form. Adobe Fillable Form. Elevation Certificates FEMA Form 81-31. Elevation Certificates Training 11/14/2013
NORFMA Floodplain Conference November 14, 2013 Boise, Idaho Agenda Introductions & Housekeeping Overview Basics of FEMA Form 81-31 Building Diagrams Exercise Common Errors Using ECs in Floodplain Development
FEMA Elevation Certificate
FEMA Elevation Certificate 2013 MARLS Conference Larry Schock, CFM DNRC Missoula Regional Office (406) 542-5885 [email protected] FEMA Elevation Certificate Presentation Overview National Flood Insurance
Elevations Certificates: Update 2009 Presented by Wendy Lathrop, PLS, CFM
Elevations Certificates: Update 2009 Presented by Wendy Lathrop, PLS, CFM The objectives of the National Flood Insurance Program (NFIP): Reduce the exposure to flood damages through the use of minimum
CONDOMINIUMS I. METHODS OF INSURING CONDOMINIUMS. Previous Section Table of Contents. Important Notice to Agents/Producers:
Previous Section Table of Contents Next Section Important Notice to Agents/Producers: CONDOMINIUMS Boards of directors of condominium associations typically are responsible under their by-laws for maintaining
Elevation Certificate Completion Guide
Elevation Certificate Completion Guide General Comment: The latest FEMA Elevation Certificate form must be used. The form can be downloaded directly from the FEMA website (FEMA.gov). All information requested
Table of Contents. Comments on the Technical Bulletins should be directed to:
Openings in Foundation Walls and Walls of Enclosures Below Elevated Buildings in Special Flood Hazard Areas in accordance with the National Flood Insurance Program Technical Bulletin 1 / August 2008 Table
Openings in Foundation Walls for Buildings Located in Special Flood Hazard Areas
Openings in Foundation Walls for Buildings Located in Special Flood Hazard Areas in accordance with the National Flood Insurance Program FEDERAL EMERGENCY MANAGEMENT AGENCY FEDERAL INSURANCE ADMINISTRATION
PIMA COUNTY REGIONAL FLOOD CONTROL DISTRICT TECHNICAL PROCEDURE
PIMA COUNTY REGIONAL FLOOD CONTROL DISTRICT TECHNICAL PROCEDURE TECHNICAL PROCEDURE TECH-113 EFFECTIVE DATE: 5/23/2007 REVISED DATE(S): 1/16/2008, 11/30/2009, 2/2/2012, 7/17/2014 PROCEDURE TITLE: Elevation
Producer Name. Producer Street Address. Producer City/State/Zipcode. Producer Phone Number. Producer Number. Insured s Name: Mailing Address:
Excess Flood Insurance Policy Application Policy Form House Condominium Cooperative Other permanent structure Policy Type New Endorsement Underlying Flood Policy #: Requested Policy Effective Date: 12:01
3/23/2015 FEMA NFIP. Session Overview
FEMA NFIP A g e n t Tr a i n i n g P r o g r a m 1 Session Overview 2 1 Introduction to the Session Session 2 Module 5: Loss Settlement Module 6: Building an NFIP Policy Module 7: Base Flood Elevation
DEPARTMENT OF PLANNING AND DEVELOPMENT
DEPARTMENT OF PLANNING AND DEVELOPMENT FLOODPLAIN DEVELOPMENT PERMIT APPLICATION FOR NON-RESIDENTIAL DEVELOPMENT Property Owner Telephone Street/P.O. Box City State ZIP Agent (if any) Relationship to Property
Summary of Coastal Construction Requirements and Recommendations
Summary of Coastal Construction Requirements and Recommendations HOME BUILDER S GUIDE TO COASTAL CONSTRUCTION FEMA 499/August 2005 Technical Fact Sheet No. 2 Purpose: To summarize National Flood Insurance
CONDOMINIUMS I. METHODS OF INSURING CONDOMINIUMS. Important Notice to Agents/Producers:
Important Notice to Agents/Producers: CONDOMINIUMS Boards of directors of condominium associations typically are responsible under their by-laws for maintaining all forms of property insurance necessary
Elevating Your House. Introduction CHAPTER 5
CHAPTER 5 Elevating Your House Introduction One of the most common retrofitting methods is elevating a house to a required or desired Flood Protection Elevation (FPE). When a house is properly elevated,
EXISTING STRUCTURES 1) FAIR MARKET VALUE OF STRUCTURE(s) BEFORE IMPROVEMENT: 2) COST OF IMPROVEMENTS:
Date Received: Received By: Project/Permit Number: Fee: (To be Completed by MOA) FLOOD HAZARD PERMIT APPLICATION (Please fill out application completely; Indicate NA if necessary. Property information
Ignoring Flood Insurance Equals an E & O Exposure
Ignoring Flood Insurance Equals an E & O Exposure Picture Courtesy of FEMA Photo Library Quick Reference - National Flood Insurance Program This is intended for overview purposes only. For complete underwriting
Quick RefeRence Guide comparison of Select nfip and Building code Requirements for Special flood Hazard Areas
Quick RefeRence Guide comparison of Select nfip and Building code Requirements for Special flood Hazard Areas This guide illustrates the similarities and highlights the differences between the National
CITY OF PITTSBURGH Department of City Planning 200 Ross Street, Pittsburgh, PA 15219 412-255-2241 412-255-2561(fax)
CITY OF PITTSBURGH Department of City Planning 200 Ross Street, Pittsburgh, PA 15219 412-255-2241 412-255-2561(fax) APPLICATION Construction and Development In the Flood Plain Overlay District This is
Local Administrator s Handbook for Floodplain Management
APPENDIX E Excerpts from unpublished Local Administrator s Handbook for Floodplain Management North Carolina Division of Emergency Management Introduction...2 Agreement between Communities and the NFIP...3
Permit Application No. Development Address. Legal Description. A. Flood Plain and Floodway Information and Sources: (To be completed with Staff)
FLOOD PLAIN DEVELOPMENT PERMIT APPLICATION of Olathe, Department of Public Works 1385 S. Robinson Drive P.O. Box 768 Olathe, Kansas 66051-0768 (913) 971-9045 FAX (913) 971-9099 Olathe, Kansas, Community
Flood Insurance Rating: Facts and Factors. Jana Green, CFM 2013 NJAFM Annual Conference October 17, 2013 Concurrent Session #3
Flood Insurance Rating: Facts and Factors Jana Green, CFM 2013 NJAFM Annual Conference October 17, 2013 Concurrent Session #3 Purpose of Presentation THIS PRESENTATION IS INTENDED TO PROVIDE: A clear and
SECTION 19 RESIDENTIAL CONSTRUCTION IN FLOODZONES
SECTION 19 RESIDENTIAL CONSTRUCTION IN FLOODZONES The purpose of the following information and documents are to clarify procedures used by the Sonoma County Permit & Resource Management Department to enforce
Understanding the National Flood Insurance Program (NFIP)in Georgia Jeff Brady September 10, 2015 2:45 PM 4:15 PM
Education Session H Understanding the National Flood Insurance Program (NFIP)in Georgia Jeff Brady September 10, 2015 2:45 PM 4:15 PM GREC Course Code # 66076 / 66077 / 66078 You must attend two 1½-hour
Free-of-Obstruction Requirements
Free-of-Obstruction Requirements for Buildings Located in Coastal High Hazard Areas in accordance with the National Flood Insurance Program Technical Bulletin 5 /August 2008 Table of Contents Introduction...1
Reducing Flood Risk to Residential Buildings That Cannot Be Elevated
Reducing Flood Risk to Residential Buildings That Cannot Be Elevated FEMA P-1037 / September 2015 Elevated utility readable from standing height ~6.5' above grade Basement infill with gravel Approximate
FLOODPLAIN MANAGEMENT IN ILLINOIS
FLOODPLAIN MANAGEMENT IN ILLINOIS 2001 Illinois Department of Natural Resources Office of Water Resources 524 South Second Street Springfield, IL 62702 (217) 782-3863 http://dnr.state.il.us/waterresources
780 CMR 120.G FLOOD-RESISTANT CONSTRUCTION AND CONSTRUCTION IN COASTAL DUNES Note that this Appendix is unique to Massachusetts
780 CMR 120.G FLOOD-RESISTANT CONSTRUCTION AND CONSTRUCTION IN COASTAL DUNES Note that this Appendix is unique to Massachusetts 120.G.101.1 General: All buildings and structures erected in areas prone
4.3.5 - Breakaway Walls
4.3.5 - Breakaway Walls Elevation of a structure on a properly designed foundation reduces the potential for water damage from flooding. When the space below the lowest elevated floor is maintained free
FLOOD DAMAGE PREVENTION ORDINANCE
FLOOD DAMAGE PREVENTION ORDINANCE SECTION 1.0 STATUTORY AUTHORIZATION, FINDINGS FO FACT, PURPOSE, AND OBJECTIVES 1.1 STATUTORY AUTHORIZATION The Legislature of the State of Washington has in RCW delegated
Elevator Installation for Buildings Located in Special Flood Hazard Areas in accordance with the National Flood Insurance Program
Elevator Installation for Buildings Located in Special Flood Hazard Areas in accordance with the National Flood Insurance Program FEDERAL EMERGENCY MANAGEMENT AGENCY FEDERAL INSURANCE ADMINISTRATION FIA-TB-4
How To Build A Floodproofed Basement
General Basement Exception Guidelines National Flood Insurance Program (NFIP) floodplain management criteria at 44 CFR 60.6 (c) provide for the granting of exceptions to permit construction of floodproofed
ARTICLE 12 FLOOD DAMAGE PREVENTION
ARTICLE 12 FLOOD DAMAGE PREVENTION SECTION 12.1 AUTHORIZATION 12.1.1 General The Legislature of the State of North Carolina has in Part 6, Article 21 of Chapter 143; Parts 3 and 4 of Article 18 of Chapter
Control filling, grading, dredging, and other development which may increase erosion or flood damage; and
ARTICLE 16. FLOOD DAMAGE PREVENTION Section 16-1: Findings of Fact The flood hazard areas of the Town of Lillington are subject to periodic inundation which results in loss of life and property, health
Frequently-Asked Questions about Floodplains and Flood Insurance FLOOD INSURANCE
Frequently-Asked Questions about Floodplains and Flood Insurance What is a floodplain? The floodplain is any area covered by water during normal water flows, and which could be inundated as a result of
Introduction to the National Flood Insurance Program: A Guide for Coastal Property Owners
Introduction to the National Flood Insurance Program: A Guide for Coastal Property Owners Maine Beaches Conference 2015 Sue Baker, CFM State NFIP Coordinator [email protected] 207-287-8063 NFIP Goal:
Single Family Residential Basement Finish
How to Use This Guide Building Guide Pottawattamie County Planning & Development Department Building & Safety Division Single Family Residential Basement Finish Provide two (2) sets of plans and complete
http://library1.municode.com/default/docview/10251/1/101/103
Page 1 of 8 ARTICLE II. FLOOD DAMAGE PREVENTION* *Cross references: Buildings and building regulations, ch. 67; floor elevation standards, 67-32; flood damage prevention for utility systems, 67-34; drainage
CHAPTER 3 page 69 LOCAL FLOODPLAIN REGULATIONS AND NFIP STANDARDS
CHAPTER 3 page 69 LOCAL FLOODPLAIN REGULATIONS AND NFIP STANDARDS LOCAL FLOODPLAIN REGULATIONS AND NFIP STANDARDS, page 69 THE PARTICIPATION OF A COMMUNITY IN THE NFIP IS MADE POSSIBLE BY ITS ADOPTION
Floodproof Construction Requirements
Floodproof Construction Requirements CITY OF FARGO BUILDING INSPECTION DIVISION Updated April 2015 The State of North Dakota requires that you call 1-800-795-0555 at least two business days before you
Sample Flood Damage Prevention Ordinance
Sample Flood Damage Prevention Ordinance COUNTY OF RABUN STATE OF GEORGIA ORDINANCE AN ORDINANCE ADOPTING FLOOD DAMAGE PREVENTION REGULATIONS OF THE CITY OF CLAYTON, GEORGIA WHEREAS; The Mayor and City
OKANOGAN COUNTY OFFICE OF PLANNING AND DEVELOPMENT FLOODPLAIN DEVELOPMENT PERMIT APPLICATION
OKANOGAN COUNTY OFFICE OF PLANNING AND DEVELOPMENT FLOODPLAIN DEVELOPMENT PERMIT APPLICATION Okanogan County Code, OCC 15.08, Floodplain Management The State of Washington has authorized county governments
SECTION 15 FLOODPLAIN MANAGEMENT
SECTION 15 15.1 Purpose Certain areas of the City of Gardiner, Maine, are subject to periodic flooding, causing serious damages to properties within these areas. Relief is available in the form of flood
Flood Insurance for Risk Managers
Flood Insurance for Risk Managers Basics of the National Flood Insurance Program August 20, 2012 Susan W. Wilson DHS/FEMA Region IV NFIP Created by National Flood Insurance Act of 1968 THIS Adopt a local
Chapter 2: Foundations
Chapter 2: Foundations Crawlspace [V502.1.2] Vents. Vents in the crawlspace help keep floor insulation and floor framing dry. Crawlspace vents also reduce the potential for radon buildup under the floor.
Tippecanoe River, White County February 2008. Indiana Department of Natural Resources Division of Water
Tippecanoe River, White County February 2008 Indiana Department of Natural Resources Division of Water October 2008 Table of Contents Foreword... Page 3 Preparing before the Flood... Page 4 Become Familiar
FEMA s FLOOD INSURANCE RATE MAPS
My Lender is requiring me to purchase Flood Insurance Options for San Diego County Residents in Unincorporated Areas This document is intended to help San Diego County residents who have been contacted
Flood Insurance Premium Increases And Increased Cost of Compliance Eligibility
Flood Insurance Premium Increases And Increased Cost of Compliance Eligibility January 11, 2015 (This document is updated frequently, so please consult the most recent edition) Margaret Becker Director
Kanawha County Floodplain Regulations Quick Guide & Overview
Kanawha County Floodplain Regulations Quick Guide & Overview CHUCK GRISHABER, CFM KANAWHA COUNTY FLOOD PLAIN MANAGER Office: 304.357.0570 Mobile: 304-356.0979 Fax: 304.357.0572 [email protected]
July 20, 2015. Subject: 7 th Avenue Creek Project Update & Elevation Certificates
July 20, 2015 Subject: 7 th Avenue Creek Project Update & Elevation Certificates Below are a few updates regarding the 7 th Avenue Creek Project. As you may recall there are two concurrent and independent
TYPICAL PATIO COVERS 111
City of Laguna Niguel Building Division 30111 Crown Valley Pkwy Laguna Niguel, CA 92677 (949) 362-4360 FAX 362-4369 www.cityoflagunaniguel.org TYPICAL PATIO COVERS 111 PLEASE NOTE: This information Bulletin
Elmore County Flood Damage Prevention Ordinance. (Non-Coastal Communities)
Elmore County Flood Damage Prevention Ordinance (Non-Coastal Communities) Adopted: April 20, 2006 Amended: July 11, 2011 FLOOD DAMAGE PREVENTION ORDINANCE Non-Coastal Communities ARTICLE 1. SECTION A.
FEMA Flood Zone Designations
Note: SFHA "Special Flood Hazard Area" FEMA Flood Zone Designations Zone VE Zone A Zone AE Zone X Zone X500 UNDES along coasts subject to inundation by the 100-year flood with additional hazards due to
Kentucky Model Flood Damage Prevention Ordinance. 2015 KAMM Annual Conference Carey Johnson Kentucky Division of Water
Kentucky Model Flood Damage Prevention Ordinance 2015 KAMM Annual Conference Carey Johnson Kentucky Division of Water Flood Damage Prevention Ordinance Also referred to as Floodplain Management Ordinance
STANDARD OPEN PATIO COVER
STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist
UNIT 9: FLOOD INSURANCE AND FLOOD MANAGEMENT
UNIT 9: FLOOD INSURANCE AND FLOOD MANAGEMENT In this unit While you are probably not an insurance agent, you should be aware of the close relationship between floodplain management and flood insurance.
17.19. Chapter 17.19 FLOOD DAMAGE PREVENTION
17.19 Chapter 17.19 FLOOD DAMAGE PREVENTION Sections: 17.19.010: Authorization, Findings of Fact, Purpose, and Objectives 17.19.020: Definitions 17.19.030: General Provisions 17.19.040: Administration
Residential Adjustments. Overview 4.1
Overview 4.1 Summary This chapter contains an overview of residential structural components, quality of construction, main dwellings, and construction types. It also provides adjustments such as wall height,
Residential Accessory Buildings
City of Republic Residential Accessory Buildings REVISION DATE: FEBRUARY 2012 Buildings less than 120 square feet (120 sq. ft.) do not require a building permit unless they: are built on a permanent concrete
Changing Flood Maps: A Guide for Homeowners and Consumers
Changing Flood Maps: A Guide for Homeowners and Consumers The flood maps in your community are being changed. What does this mean to you? Flood maps, also known as Flood Insurance Rate Maps or FIRMs, are