DELIVERY SPECIFICATIONS

1. Scope This specification is applied to ICR Product Specification Table 1 No. Item Rated Performance Remark

BAO TONG USA dba TYSONIC BATTERY. SPECIFICATION SHEET FOR 9V NI-MH RECHARGEABLE BATTERY TY-9V-200mAH

Li-Polymer Battery Technology Specification

Specification. Li-ion Rechargeable Battery

Lithium Ion Battery Specifications

Li-ion Rechargeable Battery. Specification

LITHIUM BATTERY CR123A SPECIFICATION

Spec. No. ICR C Version No. 0.0

Li-ion Polymer Battery Specification

NI-ZN BATTERY SPECIFICATION

EVERGREEN (C.P.) USA INC. TEL: (650) FAX: (650) SPECIFICATIONS Lithium Battery CR123A- 1700mAh

LI-POLYMER BATTERY PACKS. Specification. Type: mAh. Prepared/Date Auditing/Date Approved/Date WANG MAR 16, 2006 LI MAR 16, 2006

li-ion Polymer Battery Specification

Approval Sheet for. Li-ion Battery (Lithium Iron Phosphate) Model: LiR14505F-600mAh

Title Li-ion Battery Specifications (Steel) Page 1/11

Specification Approval Sheet

PRODUCT SPECIFICATION

Lithium-Polymer Battery

Product Specification

A23 TECHNICAL SPECIFICATION FOR ALKALINE MANGANESE DIOXIDE BATTERY DATE : 21/8/2003

Product Specification

Superior Lithium Polymer Battery

Product Specification

Product Specification

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

Handbook. We aim to bequeath a beautiful Earth for our future generations.

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

Height w/o Terminals (in)

IEC nd Edition: All you need to know about the new standard

Carefree Sealed Lead Acid (SLA) MSDS

NC2000 Charge Controller for Nickel-Cadmium and Nickel-Metal Hydride Batteries

SHENZHEN PKCELL BATTERY CO., LTD. Li-Polymer Battery Technology Specification

Lithium-ion Battery Specification

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

LITHIUM BALANCE CHARGER

How To Use A Power Supply Unit (Upu)

INSTALLATION AND OPERATION MANUAL. Batteries for electric drive of bikes EVBAT48V9A-R EVBAT36V13A-R

Alkaline Manganese (Mercury free) IEC: LR03; JIS: AM-4; ANSI: AAA; MN2400; Micro chemical system: Zn / KOH-H 2 O / MnO 2

NI-MH HANDBOOK INDUSTRIAL BATTERIES APPLICATIONS

400 Amp Rechargeable Jump Start System RAC-HP082

TELEDYNE BATTERY PRODUCTS. INSTRUCTIONS FOR CONTINUED AIRWORTHINESS and COMPONENT MAINTENANCE MANUAL. For

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

It is strongly recommended to completely read this manual before use! Damage resulting from misuse or modification will void your warranty.

User Manual for CH-PFC76810

HHR120AA Cylindrical 4/5AA size (HR 15/43) Dimensions (with Tube)

Thyristor-controlled power supplies and battery chargers

Height w/o Terminals (in)

HYPERION EOS0606i-B USER S MANUAL Visit for the newest manuals and news

User s Manual AURORA 1.2K/2.2K

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

TRANSPORT OF DANGEROUS GOODS

Important Safety Instructions

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

BB800 Off-Grid Solar System

Battery Model: 25 Part Number: Nominal Voltage: 12 volts NSN: Number applied for, product currently available

UN Manual of Tests and Criteria, Sub-section 38.3, Amendments to the 5 th edition, effective 2014 January 1 st

Aluminum Electrolytic Capacitors Power Eurodin Printed Wiring

#178 Maintenance and Care of 3M Powered Air Purifying Respirator (PAPR) Battery Packs

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

Alkaline Manganese Dioxide Battery Product Safety, Transportation and Disposal

Lithium-Ion Battery SPECIFICATION

Guidance for upgrading to GB (IEC : 2005, MOD)

3 WATT LED SPOTLIGHT Model No. SLM

S P E C I F I C A T I O N F O R L I T H I U M B A T T E R Y. M o d e l : C R

Mini Power Bank and Charger

International English

Ni-MH Rechargeable Batteries

AS A Low Dropout Voltage Regulator Adjustable & Fixed Output, Fast Response

Charge Regulator SCR 12 Marine

User s Manual Before using the inverter, you need to read and save the safety instructions.

Odyssey of the Mind Technology Fair. Simple Electronics

Solar Controller / Battery Charger User s Manual

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

12 Volt 30 Amp Digital Solar Charge Controller

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Aluminum Electrolytic Capacitors Radial Miniature, Low Impedance, High Vibration Capability

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac

handbook, 2 columns handbook, halfpage 085 CS

Overlander RC-6S Pro User s Manual

Aluminum Electrolytic Capacitors Power Economic Printed Wiring

Battery Cell Balancing: What to Balance and How

Temperature Compensated Charging of Lead Acid Batteries

UT202A Operating Manual. Contents

QuickSaver Charge Controller for Nickel-Cadmium and Nickel-Metal Hydride Batteries

CHARGING METHODS. Methods of Charging the Valve Regulated (Sealed) Lead-Acid Battery. 19 Valve Regulated (Sealed) Lead-Acid Batteries

Product Title Abstract

Model 70A00-1. GSM Cellular Communications Center

Nickel Metal Hydride (NiMH) Handbook and Application Manual

Aluminum Electrolytic Capacitors Axial Miniature, Long-Life

HAIR CLIPPER. Model No. HC5150 HC

Solar Home System Kit Quality Standards

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Maintenance-free sealed lead accumulators. HAGEN drysafe

Primary lithium battery LST 14250

Application Manual. Nickel Cadmium 11/06/01 Page 1 of 12

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Transcription:

Document Number: TQS4205 Rev.: 03 Page 0 of 4 Modification History: Rev. Description Originator Approver Date 02 1. Change the Remarks of Capacity from Up to 3 cycles are allowed to Up to 3 cycles are allowed. The test shall be terminated at the end of the first cycle which meets the requirement. GB Zhan HB Zhang 26/Apr./2010 2. Change the specification of Accelerated Cycle Life form > 300 to > 200 3. Add point 24 to section 7. CAUTION 03 1. Change the specification of Nominal Capacity from 930 to 950; Change the specification of Minimum Capacity from 930 to 950; 2. Change the current of 0.1C from 93 to 95; 3. Change the specification of Storage Temperature GB Zhan HB Zhang 2013-05-10 from -20 ~ 35 to -20 ~ 30 ; 4. Change the specification of Charge Retention from > 390(60%)(28 days at RT or 7 days at 45 ) to > 665(70%) (6months at RT). 1.

Document Number: TQS4205 Rev.: 03 Page 1 of 4 1. SCOPE This specification governs the performance of the following GP Nickel-Metal Hydride Cylindrical Cell and its stack-up batteries. GP Model: GP100AAAHC Cell Size: AAA The data involving nominal voltage and the approximate weight of stack-up batteries shall be equal to the value of the unit cell multiplied by the number of cells in the battery. For example, a stack-up battery consists of three unit cells: Nominal Voltage of unit cell = 1.2V Thus, nominal voltage of stack-up battery = 1.2V x 3 = 3.6V 2. RATINGS Description Unit Specification Conditions Nominal Voltage V 1.2 Unit cell Typical Capacity mah 970 Standard Charge / Discharge Nominal Capacity mah 950 Standard Charge / Discharge Minimum Capacity mah 950 Standard Charge / Discharge Standard Charge ma 95 (0.1C) T a = 0 ~ 45 Hr 16 (See Note 1) Fast Charge 950 (1C) -ΔV = 0 ~ 5mV/ cell or ma Timer cutoff = 105% input capacity hr 1.05 approx. (See Note 2) Temp. cutoff = 45 ~ 50 T a = 10 ~ 45 dt/dt = 0.8 ~ 1 /min (1C) ** for ref. only Trickle Charge ma 47.5 (0.05C)~95 (0.1C) T a = 0 ~ 45 Discharge Cut-off Voltage V 1.0 Unit cell Maximum Discharging Current ma 2850 (3C) T a = -20 ~ 50 Storage Temperature -20 ~ 30 Typical Weight g 15.2 Unit cell 3. PERFORMANCE Unless otherwise stated, tests should be done within one month of delivery under the following conditions: Ambient Temperature, T a : 20 + 5 Relative Humidity : 65 + 20%RH

Document Number: TQS4205 Rev.: 03 Page 2 of 4 Notes: Standard Charge / Discharge Condition Charge : 95mA (0.1C) x 16hrs Discharge : 190mA (0.2C) to 1.0V/cell Test Unit Specification Conditions Remarks Capacity mah > 950 Standard Charge / Discharge Open Circuit Voltage (OCV) V >1.25 Within 1hr after standard charge Up to 3 cycles are allowed. The test shall be terminated at the end of the first cycle which meets the requirement Unit cell Internal Impedance (Ri) mω < 55 Upon fully charge (1kHz) Unit cell High Rate Discharge (0.5C) High Rate Discharge (1C) minute > 108 Standard Charge, 1hr rest before discharge min > 48 Standard Charge, 1hr rest before discharge Overcharge N/A No leakage nor 95mA (0.1C) charge for 1yr explosion Charge Retention mah > 665(70%) Standard Charge, Storage: 6months at 20, Standard Discharge IEC Cycles Test Cycle > 500 IEC 61951-2 (2011) 7.5.1 (See Note 3) Accelerated Cycle Life Cycle > 200 Charge: 950mA (1C) Cycling charging cutoff Discharge: 950mA (1C) to condition: 1.0V/cell -ΔV = 0 ~ 5mV/cell or timer End of life: 80% of nominal cutoff = 105% of input capacity capacity Leakage N/A No leakage nor Fully charged at 950mA deformation (1C), stand for 14days External Short circuit N/A No fire and no explosion. After standard charge, short circuit the cell at 20+/-5 until the cell temperature returns to ambient temperature. (The resistance of the inter-connecting circuitry shall not exceed 0.1 ohm.)

Document Number: TQS4205 Rev.: 03 Page 3 of 4 Test Unit Specification Conditions Remarks Vibration N/A Change of voltage Charge at 0.1C for 16hrs, Unit cell Resistance ΔV < 0.02V and then leave for 24hrs, Change of Internal check battery before / after impedance vibration ΔRi< 5mΩ Amplitude: 1.5mm Vibration: 3000CPM (Any direction for 60mins) Impact N/A Change of voltage Charge at 0.1C for 16hrs, Unit cell Resistance ΔV < 0.02V and then leave for 24hrs, Change of Internal check battery before / after impedance drop ΔRi< 5mΩ Height: 50cm Thickness of the wooden board: 30mm Direction is not specified Test for 3 times 4. CONFIGURATIONS, DIMENSIONS AND MARKINGS Please refer to the related drawing. 5. EXTERNAL APPEARANCE The cell / battery shall be free from cracks, scars, breakage, rust, discoloration, leakage and deformation. 6. WARRANTY One year limited warranty against workmanship and material defects. 7. CAUTION 1. Batteries should be charged prior to use. 2. For charging methods please referred to our technical handbook. 3. Use the correct charger for Ni-Cd or Ni-MH batteries. 4. Do not reverse charge batteries. 5. Do not subject batteries to adverse condition such as extreme temperature, deep cycling and excessive over charge/over discharge. 6. Avoid batteries being used in an airtight compartment. Ventilation should be provided inside the battery compartment; otherwise batteries may generate hydrogen gas, which could cause an explosion if exposed to

Document Number: TQS4205 Rev.: 03 Page 4 of 4 an ignition source.. 7. Do not attempt to take batteries apart or subject them to pressure or impact. Heat may be generated or fire may result. The alkaline electrolyte is harmful to eyes and skin, and it may damage clothing upon contact. 8. Keep away from children. If swallowed, contact a physician at once. 9. Do not short circuit batteries; permanent damage to batteries may result. 10. Do not incinerate or mutilate batteries, may burst or release toxic material. 11. Do not solder directly to cells or batteries. 12. Store batteries in a cool dry place. 13. If find any noise, excessive temperature or leakage from a battery, please stop its use. 14. When not using a battery, disconnect it from the device. 15. When using a new battery for the first time or after long-term storage, please fully charge the battery before use. 16. Do not mix new batteries in use with semi-used batteries, over-discharge may occur. 17. When connecting a battery pack to a charger, ensure correct polarity. 18. When the battery is hot, please do not touch it and handle it, until it has cooled down. 19. Do not remove the outer sleeve from a battery pack nor cut into its housing. 20. When find battery power down during use, please switch off the device to avoid over discharge. 21. Unplug a battery by holding the connector itself and not by pulling at its cord. 22. After use, if the battery is hot. Before recharging it, allow it to cool in a well-ventilated place out of direct sunlight. 23. Never put a battery into water or seawater. 24. In order to maintain satisfactory cell/battery performance when being stored under extending period of time, cycling (i.e. charging and discharging) of the cell / battery within 6 months period is highly recommended. At least one times cycling should be conducted within one year. Notes : 1. T a : Ambient Temperature 2. Approximate charge time from discharged state, for reference only. 3. IEC 61951-2(2011) 7.5.1 Endurance in cycles: Cycle No. Charge Rest Discharge 1 0.1C x 16hrs None 0.25C x 2hrs20mins 2-48 0.25C x 3hrs10mins None 0.25C x 2hrs20mins 49 0.25C x 3hrs10mins None 0.25C to 1.0V/cell 50 0.1C x 16hrs 1-4hr(s) 0.2C to 1.0V/cell Cycle 1 to 50 shall be repeated until the discharge duration on any 50th cycle becomes less than 3hrs