General Specifications



Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

Manuals for This Product

DeltaV Remote Client. DeltaV Remote Client. Introduction. DeltaV Product Data Sheet. Remote engineering and operator consoles

General Specifications

Terminal Server Software and Hardware Requirements. Terminal Server. Software and Hardware Requirements. Datacolor Match Pigment Datacolor Tools

Ultra Thin Client TC-401 TC-402. Users s Guide

For the latest information, check the product home page ( en/products/rack2_smart).

DeltaV Executive Portal

Relational Production Information Control System PREXION TM with Smart Client MIB

NEC Projector User Supportware 2 Software Utility Installation Guide

AXIS Camera Station Quick Installation Guide

General Specifications

How To Use Safety System Software (S3)

X Series Application Note 43:

Customer Tips. Xerox Network Scanning TWAIN Configuration for the WorkCentre 7328/7335/7345. for the user. Purpose. Background

Autodesk Building Design Suite 2012 Standard Edition System Requirements... 2

SECTION CONTROL SOFTWARE

DVR4C Remote Viewer Operation Manual Table of Contents EN 3 1. OVERVIEW MINIMUM PC REQUIREMENTS INSTALLING THE PROGRAM...

Grant Management. System Requirements

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

WebEx. Remote Support. User s Guide

Web Supervisor/Agent. System Requirements & Troubleshooting Guide. 989 Old Eagle School Road Wayne, PA (610)

To get started, you will need the following items Product Key Router with firewall capability Network cables

INSTALLATION GUIDE. AXIS Camera Station

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

================================================================== CONTENTS ==================================================================

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.

Network Disk Recorder WJ-ND200

Fleet Management System FMS. User Manual

Autodesk 3ds Max 2010 Boot Camp FAQ

USB-MIDI Setup Guide. Operating requirements

Using. Microsoft Virtual PC. Page 1

Licenses of savic-net for Integrated Building Management System for FDA Title 21 CFR Part 11 Compliance

TrueAlarm Fire Alarm Systems

User Guide Win7Zilla

LockView 4.2 CompX Database & Network Configuration & Installation Manual

Avigilon Control Center Server User Guide

User's Manual. License Management IM 32Q01C60-31E IM 32Q01C60-31E. 4th Edition

Metalogix SharePoint Backup. Advanced Installation Guide. Publication Date: August 24, 2015

For designers and engineers, Autodesk Product Design Suite Standard provides a foundational 3D design and drafting solution.

Microsoft Office Outlook 2013: Part 1

Preparing the Windows version of the software for use

DiskPulse DISK CHANGE MONITOR

Abila Grant Management. System Requirements

Multi-Share User Instructions

Autodesk Inventor on the Macintosh

NETWRIX IDENTITY MANAGEMENT SUITE

Frequently Asked Questions (FAQ)

LockView CompX Database & Network Configuration & Installation Manual

InventoryControl for use with QuoteWerks Quick Start Guide

Remote Support. User Guide 7.23

Microsoft Office 2010 system requirements

Ovation Operator Workstation for Microsoft Windows Operating System Data Sheet

DTAP3000 DTSX3000 Control Visualization Software LAS2.0 Data Conversion Guide

FactoryTalk Gateway Getting Results Guide

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

LOREX CLIENT Remote Software 4.0

EasyMP Network Projection Operation Guide

PARALLELS SERVER 4 BARE METAL README

AXIS Camera Station Comprehensive video management software for monitoring, recording, playback and event management

Core Protection for Virtual Machines 1

Mitchell 1 / ShopKey Shop Management Installation

Solution Brief: Creating Avid Project Archives

Sharp Remote Device Manager (SRDM) Server Software Setup Guide

Licenses of savic-net for Integrated Building Management System, and for FDA Title 21 CFR Part 11 Compliance

EasyMP Multi PC Projection Operation Guide

DCPS STUDENT OPTION HOME USE PROGRAM SIGN UP INSTRUCTIONS

USB 3.0 to HDMI External Multi Monitor Graphics Adapter with 3-Port USB Hub HDMI and USB 3.0 Mini Dock 1920x1200 / 1080p

Quick Start Using DASYLab with your Measurement Computing USB device

Topaz Installation Sheet

DUKANE Intelligent Assembly Solutions

Chapter 12: Windows XP, Vista, and 7

Web VTS Installation Guide. Copyright SiiTech Inc. All rights reserved.

Xerox Multifunction Devices. Verify Device Settings via the Configuration Report

SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional.

Installing Emageon PACS Remote Ultravisual

Sage Grant Management System Requirements

Ekran System List of Frequently Asked Questions

TECHNICAL BULLETIN. Checking the products and their versions that we have confirmed the operation on Windows 8 and Windows 8.1.

Revit products will use multiple cores for many tasks, using up to 16 cores for nearphotorealistic

Monitor Wall 4.0. Installation and Operating Manual

Autodesk Revit 2016 Product Line System Requirements and Recommendations

Operating Instructions

PARALLELS SERVER BARE METAL 5.0 README

intertrax Suite resource MGR Web

Priority Pro v17: Hardware and Supporting Systems

Cisco IP Communicator (Softphone) Compatibility

Why Use ThinManager to Manage Thin Clients? White Paper. For more information, please visit:

Enterprise Edition Technology Overview

RICOH Web SmartNetMonitor. Device Management Software

USB 3.0 to VGA External Multi Monitor Graphics Adapter with 3-Port USB Hub VGA and USB 3.0 Mini Dock 1920x1200 / 1080p

Multi-Profile CMOS Infrared Network Camera

A+ Guide to Software: Managing, Maintaining, and Troubleshooting, 5e. Chapter 3 Installing Windows

Transcription:

GR0001 Distillation column 100 100 Column flow AUT NR PV M3/H 70.0 SV M3/H 50.0 MV % 65.0 100.0 80.0 60.0 40.0 20.0 0.0 TDA 37.5? 53.8? RC-10 23.4 % TRC 49.2? 38.9? LICA 25.4 % 51.3? PAC LICA 45.7 % 48.9 Tank1 100 TIC301 TIC301 AUT NR 100.0 0.0 TG1001 Block:10 Group:01 102.3 82.3 62.3 42.3 22.3 2.3 2 1 00:12:00 100% 13:34 13:36 13:38 13:40 13:42 13:44 1 001. PV Inlet flow 72.1 M3/h 100.0 0.0 2 002. PV Outlet flow 53.3 M3/h 100.0 0.0 3 LIC100. PV Level 3.8 M 100.0 0.0 4 TIC100. PV Temp A 25.7 DEGC 100.0 0.0 5 TIC200. PV Temp B 14.1 DEGC 100.0 0.0 6 7 8 <<Contents>> <<Index>> General Specifications GS 33K05D20-50E LHS1150, LHM1150 Server for Remote Operation and Monitoring Function GENERAL CENTUM VP Server for Remote Operation and Monitoring Function can be executed from the remote PCs for plant operation and monitoring. By using the terminal service (TS) server of the Windows Server, the Server for Remote Operation and Monitoring Function allows multiple PCs which are connected with one server simultaneously operating and monitoring in the TS server. If a PC is located away from the instrument room, as long as the PC is connected to the HIS terminal service server through the network, the operation and monitoring view on the HIS can be displayed on the remote PC. The remote PC does not need to have the operation and monitoring applications. LHM1150 is a package for CENTUM VP Entry Class, which is suitable for small systems. The basic features are the same as LHS1150. FUNCTION SPECIATIONS System Configuration The Server for Remote Operation and Monitoring Function runs on a in Windows Server OS, allowing it to be a server for remote-access operation and monitoring. If user names are entered and logged on from a network client PC connected to the server for remote operation and monitoring, the functions running on the server for remote operation and monitoring can be used on the client PC. Distillation column 41.4 TDT Client PC 001.PV Office building Site Client PC Intranet CENTUM VP HIS Server for Remote Operation and Monitoring Vnet/IP FCS Central control room Figure Example of Configuration of Server for Remote Operation and Monitoring Function A maximum of eight simultaneous sessions (a session stands for a logic connection to the server for remote operation and monitoring function started from logon and ended at logoff) can be run on one server for remote operation and monitoring. Logging on from the server for remote operation and monitoring is also counted as one session. A client PC can display screens on a session-by-session basis regardless of the screens displayed on the server for remote operation and monitoring or on other clients. It may take a few seconds for the client PC to display the screens depending on the network speed. When using the Server for Remote Operation and Monitoring Function, please set up one or more standard HIS along with the client PC on the control network (Vnet/IP or V net). The standard HIS has better reliability for real-time operations than the client PC. For instance, the control network communication fails between the Server for Remote Operation and Monitoring and the client PC, the operation and monitoring from the client PC become unavailable while the standard HIS continues its control and monitoring. F01E.ai Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5634 Fax.: 81-422-52-9802 GS 33K05D20-50E Copyright Aug. 2011 (YK) 6th Edition June 12, 2013 (YK)

2 Functions Available for Remote Operation and Monitoring The functions running on the server for remote operation and monitoring can be used on the client PC. Standard builder functions realize engineering with a remote PC using the TS functions directly. In this case, the standard builder function can connect only one session apart from eight sessions for operation and monitoring. System views on multiple PCs, including the server for remote operation and monitoring, cannot be started simultaneously. However, if reference builders are called up in reference mode, screens can be displayed on multiple PCs. If LHM1150 (CENTUM VP Entry Class) is used, select the packages that are in parentheses. Packages with no parentheses can be directly used in CENTUM VP Entry Class (except for LHS4000). Table Package Coexistence in the Server for Remote Operation and Monitoring (1/2) Model Name Coexistence Note LHS1100 (LHM1101) Standard Operation and Monitoring Function X LHS1120 Console HIS Support Package for Enclose Display Style - LHS1130 Console HIS Support Package for Open Display Style - LHS2411 Exaopc OPC Interface Package (for HIS) X When the OPC package is used on the remote operation and monitoring server, it behaves slightly different when it is used with the standard HIS. Confirm the operation of the application program under the server for remote operation and monitoring environment is required. LHS2412 CENTUM Data Access Library X The operation check is required in each created application. LHS4000 Million Tag Handling Package X LHS4100 Configured information Reference Package X LHS4150 Output to External Recorder Package - LHS4190 Line Printer Support Package - LHS4200 Consolidated Historical Message (Meeting FDA) - LHS4410 (LHM4410) Control Drawing Status Display Package X LHS4420 (LHM4420) Logic Chart Status Display Package X LHS4450 Multi project Connection Package X LHS4600 Multiple-Monitor Support Package - LHS4700 Advanced Alarm Filter Package - LHS6510 Long-term Data Archive Package X LHS6530 Report Package - A remote operation environment can be constructed by installing the Report Package in the client PC. LHS6660 (LHM6660) LHS6710 (LHM6710) X: Yes - : No Process Management Package FCS Data Setting/Acquisition Package (PICOT) - X Please define the server for remote operation and monitoring as a client station in the process management configuration definition.

3 Table Package Coexistence in the Server for Remote Operation and Monitoring (2/2) Model Name Coexistence Note LHS5100 (LHM5100) Standard Builder Function X Only one session is available simultaneously. LHS5110 Access Control package X Only one session is available simultaneously. LHS5150 Graphic Builder X Only one session is available simultaneously. LHS5165 Batch Builder X Only one session is available simultaneously. LHS5166 Recipe Management Package X Only one session is available simultaneously. LHS5170 Access Administrator Package (FDA:21 CFR Part 11 compliant) X Only one session is available simultaneously. LHS5420 (LHM5150) Test Function - LHS5425 Expanded Test Package - LHS5426 FCS Simulator Package - LHS5427 HIS Simulator Package - LHS5450 Multiple Project Connection Builder X Only one session is available simultaneously. LHS5490 (LHM5490) Self-documentation Package X Only one session is available simultaneously. LHS5495 Electronic Instruction Manual X Only one session is available simultaneously. LPC6920 Sem Sequence of Event Manager (for FIO) X X: Yes - : No

4 Operation Screen Mode and Display Mode HIS provides two operation screen modes, full-screen mode and window mode. In each mode, HIS displays views such as the Graphic View or the Trend View. Moreover, a remote HIS terminal connected through the Server for Remote Operation and Monitoring Function package also has two display modes. Operation Screen Mode Full-Screen Mode In this mode, HIS displays a frame that consists of several views assigned for a certain function or purpose. On a standard HIS, a number of tabbed frames can be displayed and overlapped in full-screen mode. However, on a remote HIS terminal connected through the Server for Remote Operation and Monitoring Function package, only a fixed frame can be displayed. In this mode, a Pop-Up Window such as a Faceplate View can be displayed in front of the frame. Window Mode In this mode, several windows can be displayed in cascade style of Microsoft Windows so that the windows are overlapped. Each window contains only one view. Display Mode On a remote HIS terminal connected through the Server for Remote Operation and Monitoring Function package, the display mode can be either desktop mode or panel mode. The mode can be selected when the client PC is connecting to the server for the remote operation and monitoring services. Desktop Mode In desktop mode, the operation and monitoring activities on a remote HIS can be carried out in the same style as on a standard HIS where the System Message Banner is displayed on the top and the Browser Bar is displayed on the left. Browser Bar System Message Banner HIS0163 - Remote Desktop Recycle Bin HIS0163T... 0? 17 0 Overview View Trend Plant TG0701 TG0801 GR0003 GR0004 GR0005 TG0901 GR0006 GR0007 SYSTEM.AL?.OG.SO.SH.SA.SF FCS0101.SF FCS0102.PR PRODUCT Comment Process Alarm Address /SYSTEM/.AL Favorite favorite-1 P MYPJT1 FCS0101 Batch Manager Ready FCS0101 RIGHT Control FCS0101 RIGHT Manual Reset Start GR0001 Distilation Column Distillation column TDA 37.5 C 41.4 % TDT 53.8 C 38.9? TRC 49.2 C LICA 25.4 % PAC 51.3 C LICA 45.7 % 48.9 2008/03/03 14:35 200 Reactor flow AUT NR PV SV MV 001 M3/H 55.3 M3/H 50.0 % 65.1 100.0 80.0 60.0 40.0 12% Copy 40% 11 12 1 10 9 8 2 3 4 7 6 5 Pop-Up Window Name Input Search 20.0 HIS0163 - Remo... 10:58 F02E.ai Figure Desktop Mode HIS Window Display in Full-Screen

5 Panel Mode In panel mode, a designated view such as Graphic View or Trend View can be displayed on desktop. The System Message Banner and the Browser Bar are not displayed. The session can be established much faster than it is in the desktop mode. Recycle Bin HIS0163 - Remote Desktop GR0001 Distilation Column 11 12 1 10 9 8 2 3 4 7 6 5 HIS0163T... Distillation column TRC 49.2 C TDA 37.5 C PAC 51.3 C 41.4 % TDT 53.8 C 38.9? LICA 25.4 % LICA 45.7 % 48.9 HIS 0163 - Remote... 10:58 F03E.ai Figure Panel Mode HIS Window Display in Full-Screen Maximum Number of Windows Maximum number of windows can be displayed on a client PC varies according to the HIS operation screen mode and the display mode defined in the Server for Remote Operation and Monitoring Function package. Operation Screen Full-Screen Mode Window Mode Mode Display Mode Frame Pop-Up Window Window Desktop Mode 1(Fixed) Maximum 2 Maximum 5 Panel Mode 1(Fixed) 1(Fixed) 2(Fixed)

Window Update Period The update period for windows displayed on a client PC can be specified in seconds (1 to 30 seconds). This is commonly set during each client session logged onto the server for remote operation and monitoring. Security System The Server for Remote Operation and Monitoring Function can be run in an independent operation and monitoring security system for each client PC by logging on using different user names. The security system for remote monitoring can be restricted. Operating Record Operating messages generated at terminal equipment identify the client PC. Buzzer A client PC can issue a buzzer via a sound device. In the panel mode, because buzzer reset key is not displayed, buzzer output is restricted compared with the desktop mode as follows: Buzzer Panel mode Desktop mode System N Y Process (high-priority alarm N Y Process (medium- or low-priority alarm) N Y Operator guide message N Y Illegal operation Y Y Confirmation Y Y Recovery N Y Click Y Y Y: Buzz N: Silent Automatic Log-off If there are no operations carried out at a client PC within a specified period of time, automatic log-off occurs. This is commonly set during each client session logged onto the server for remote operation and monitoring. The inactive period for automatic log-off can be set in minutes (1 to 59 minutes). Automatic log-off can be disabled. 6 Functional Difference between the Server for Remote Operation and Monitoring Function and the Standard HIS Below is functional difference between the Server for Remote Operation and Monitoring Function and the standard HIS. A sound function is required on the client PC in order to use a buzzer with the remote operation and monitoring function server. The operation and monitoring range on a remote HIS terminal can be defined by the settings on the User Security Builder. The operation and monitoring range on a standard HIS is the range that is permitted by both the settings on HIS Constants Builder defined for each HIS and the settings on the User Security Builder defined for each user. The security settings on HIS Constants Builder defined for each HIS are not valid for the remote HIS terminal, only the settings on the User Security Builder are valid. When restricting the range of operation and monitoring of a user according to the security seetings for the user, the alarm and operator guide messages can be inhibited but not the corresponding buzzer sounds. The buzzer sound of a message will be triggered anyway as long as an alarm or an operator guide message occurs even though the message is inhibited by security settings. Therefore, when applying user security settings to restrict user s operation and monitoring range, it is necessary to turn off the buzzer of the client PC. Operation keyboards cannot be used on both the server PC and the client PC. Up to 50 simultaneous primitives of the trend can be displayed in the client PC. Displaying the Graphic Window to which a number of primitive trends are allocated in several sessions might not display some primitive trends. The function automatically printing messages such as the process alarm is not equipped. The print function from the historical report window and the process data window and the hard copy button are available just like HIS. Functional Difference between the Client PC and the Server PC Below is functional difference between the client PC and the server PC. The function from the scheduler is executed only on the server PC. The request of the sequence message is processed only on the server PC. The panel set is displayed only on the server PC. When the Windows are called up from another HIS, the Windows are displayed only on the server PC. When the message is generated, the automatic window switching is performed only on the server PC.

7 OPERATING ENVIRONMENT LHS1150, LHM1150 Server for Remote Operation and Monitoring Function Hardware Operating Environment For Windows Server 2008 CPU Xeon dual core minimum 2.93 GHz Main memory 4 GB Hard disk Free space of minimum 40 GB (*1) Recommended Free space of minimum 70 GB (*1) Display Minimum SXGA (1280x1024) resolution, True Color (min. 16.77 million colors) For wide screen Minimum WXGA+ (1440x900) resolution, True Color (min. 16.77 million colors) Graphics DirectX 9-class GPU(Graphics Processing Unit) that supports A WDDM(Windows Driver Display Model) Driver Pixel Shader 2.0 in hardware 32 bits per pixel 128 MB Graphics memory Expansion slot 1 slot is used for control network interface (*2) Mouse Optical disc drive DVD-ROM *1: When the optional software package (Long-term Data Archive Package) is used, see also the GS Long-term Data Archive Package (GS 33K05J10-50E). *2: VI702/VI701 or VF702/VF701 is required for control network interface card. For Windows Server 2008 R2 CPU Xeon dual core minimum 2.93 GHz Main memory 8 GB Hard disk Free space of minimum 40 GB (*1) Recommended Free space of minimum 70 GB (*1) Display Minimum SXGA (1280x1024) resolution, True Color (min. 16.77 million colors) For wide screen Minimum WXGA+ (1440x900) resolution, True Color (min. 16.77 million colors) Graphics DirectX 9-class GPU(Graphics Processing Unit) that supports A WDDM(Windows Driver Display Model) Driver Pixel Shader 2.0 in hardware 32 bits per pixel 128 MB Graphics memory Expansion slot 1 slot is used for control network interface (*2) Mouse Optical disc drive DVD-ROM *1: When the optional software package (Long-term Data Archive Package) is used, see also the GS Long-term Data Archive Package (GS 33K05J10-50E). *2: VI702/VI701 or VF702/VF701 is required for control network interface card. Software Operating Environment Windows OS The relations between Windows and CENTUM VP Windows Server 2008 Standard Edition 32-bit SP2 Windows Server 2008 Standard Edition R2 64-bit SP1 R5.01 Yes Yes R5.02 Yes Yes R5.03 Yes Yes Yes: Compatible No: Incompatible Note: Service Pack is abbreviated as SP (Example: SP1 stands for Service Pack 1). Note: To enable this function, LHS1100 or LHM1101 Standard Operation and Monitoring Function is required for the server PC. Neither LHS1100 nor LHM1101 Standard Operation and Monitoring Function is required for the client PC. Note: A server PC with Windows Server 2008 or Windows Server 2008 R2 itself cannot be used for operation and monitoring function. In addition to a Server License and Windows Server Client Access License (CAL), following licenses are needed. for Windows Server 2008: Terminal Services Client Access License (TS CAL) for Windows Server 2008 R2: Remote Desktop Services Client Access License (RDS CAL) GS 33K05D20-50E June 12, 2013-00

8 Client PC Operating Environment Hardware Operating Environment Maintain the operating environment of the hardware requirements for LHS1100, LHM1101 Standard Operation and Monitoring Function. If used in desktop mode, it is recommended that the display resolution be at least 1280 x 1024 pixels. If used in panel mode, it is recommended that the display resolution be 1024 x 768 pixels or greater. Software Operating Environment Windows 7, Windows Vista MODELS AND SUFFIX CODES Model Suffix Option Description Server for Remote Operation and LHS1150 Monitoring Function -V Software License 1 Always 1 1 English version Number of client PCs that can be /N0004 simultaneously connected: Up to four Number of client PCs that can be /N0008 simultaneously connected: Up to eight Note: Be sure to specify one of the optional specifications. Model Suffix Description Server for Remote Operation and LHS1150 Monitoring Function -E Additional Client License 1 Always 1 1 English version Additional number of client PCs that /N0408 can be connected simultaneously (up to four up to eight) ORDERING INFORMATION Specify model and suffix codes. TRADEMARKS CENTUM is a registered trademark of Yokogawa Electric Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and/or other countries. Ethernet is a registered trademark of XEROX Corporation in the United States and/or other countries. Other product and company names appearing in this document are trademarks or registered trademarks of their respective holders. Model Suffix Option Description Server for Remote Operation and LHM1150 Monitoring Function (for CENTUM VP Entry Class) -V Software License 1 Always 1 1 English version Number of client PCs that can be /N0004 simultaneously connected: Up to four Number of client PCs that can be /N0008 simultaneously connected: Up to eight Note: Be sure to specify one of the optional specifications. Model Suffix Description Server for Remote Operation and LHM1150 Monitoring Function (for CENTUM VP Entry Class) -E Additional Client License 1 Always 1 1 English version Additional number of client PCs that /N0408 can be connected simultaneously (up to four up to eight) Subject to change without notice. GS 33K05D20-50E Feb. 8, 2012-00