EMC Test Report For Shenzhen Lisaier Tronics Co., Ltd. Headphone and Earphone Model: See Appendix 1

Similar documents
EMC TEST REPORT For. Webcam. Model Number: CAM67U

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

TEST REPORT EN (1997) +A1 (2001)

Test Report #: Date: April 8, 2005

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

Declaration of Conformity.

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.

Declaration of Conformity.

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

Declaration of Conformity.

Declaration of Conformity.

Electromagnetic Compatibility Test Report Test results of Floww equipment

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS AND CLASS A TESTING

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

Declaration of Conformity.

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC File reference No:

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT S-E

Declaration of Conformity.

TEST REPORT FROM RFI GLOBAL SERVICES LTD

RADIO TEST REPORT. EN SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL

EMC Test for Compliance with EU EMC Directive 2004/108/EU

TEST REPORT Rapporto di prova EMC N Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

CE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board

Dual Chamber Temporary External Pacemaker

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Waveguide Access Point WGA631. Product Guide

FIBRE-OPTICS POWER METER INSTRUCTION MANUAL

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J test set up, using measured current in NEC and simple TX equations.

Fibre Optic Solutions for your Test and Instrumentation needs

CHAPTER 6 INSTRUMENTATION AND MEASUREMENTS 6.1 MEASUREMENTS

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

AN3353 Application note

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613

Partial GSM TEST - REPORT

TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization

Draft ETSI EN V1.2.1 ( )

Coaxial Cable Feeder Influence on Yagi Antenna Dragoslav Dobričić, YU1AW

RX-AM4SF Receiver. Pin-out. Connections

CE Test Report. : Microchip Technology Inc West Chandler Blvd., Chandler, Arizona , USA

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

Automatic Distance/Time Speedmeter Handbook (Second Edition) Provisional

MSAN-001 X-Band Microwave Motion Sensor Module Application Note

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)

Edition 3 has been approved and released ahead of schedule. The status is shown in the table below:

DATA SHEET DVI - HDCP Extension Cable

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

Minimum requirements for DVB-T receiving antennas for portable indoor and portable outdoor reception

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date

NMI R 118 Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIML R 118:1995(E), NEQ)

Current Probes. User Manual

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz

Model BiConiLog Antenna MANUAL EMC TEST SYSTEMS, L.P. MARCH 2002 REV C PN

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Agilent P940xA/C Solid State PIN Diode Switches

The EMI-Receiver according to CISPR

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Item tested : Tecsonic DAB518. Type of equipment : DAB & FM radio. Client : Post- og teletilsynet

SR450 RECEIVER OPERATING INSTRUCTIONS

Human Exposure Limits

Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

SAR Comparison Report

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output

Radiated Emission and Susceptibility

Huawei NE5000E 400Gbps Flexible Line Processing Unit

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Embedded FM/TV Antenna System

ORION TELECOM NETWORKS INC. T1

RD625. Digital Migration Radio. Wall Mount Repeater for Indoor.

Design and Certification of ASH Radio Systems for Japan

Agilent E5100A Network Analyzer

Byonics Micro Trak 1000 High Altitude Balloon Tracker

Wireless Medical Telemetry Laboratory

NI USB-5681 RF Power Meter Specifications

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

LVDS Technology Solves Typical EMI Problems Associated with Cell Phone Cameras and Displays

BSA Technical Information

Telephone- and leased line modem for industrial applications TD-36

Antenna Splitter ASA 1. Instruction manual

Rules for Classification and Construction Additional Rules and Guidelines

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

IEC ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

Transcription:

EMC Test Report For Shenzhen Lisaier Tronics Co., Ltd. Headphone and Earphone Model: See Appendix 1 Prepared For : Shenzhen Lisaier Tronics Co., Ltd. NO. 22, Xihu Industrial Park, Xikeng Henggang Town, Longgang District, Shenzhen, China Prepared By : Beide (UK) Product Service Limited Flat 107, 25 Indescon Square, London, United Kingdom 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao'an Dist, Shenzhen, China Report Number: B-E14116436 Date of Test: Nov. 10-14, 2014 Date of Report: Nov. 17, 2014 Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 1 of 26

TABLE OF CONTENT Description Page Test Report Declaration 1. TEST RESULTS SUMMARY... 4 2. GENERAL INFORMATION... 5 2.1. Report Information... 5 2.2. Description of Device (EUT)... 5 2.3. Test Facility... 5 2.4. Test Uncertainty... 5 2.5. Test Condition... 5 2.6. Test Conditions... 6 2.7. Performance Criterion... 6 3. TEST INSTRUMENT USED... 7 3.1. For Radiation Emission Test... 7 3.2. For Electrostatic Discharge Immunity Test... 7 3.3. For Radio Frequency Electromagnetic Field... 7 4. RADIATION EMISSION TEST... 8 4.1. Block Diagram of Test Setup... 8 4.2. Test Standard... 8 4.3. Radiation Emission Limit... 8 4.4. EUT Configuration on Test... 8 4.5. Operating Condition of EUT... 8 4.6. Test Procedure... 9 4.7. Radiation Emission Test Results... 9 5. ELECTROSTATIC DISCHARGE TEST... 10 5.1. Block Diagram of Test Setup... 10 5.2. Test Standard... 10 5.3. Severity level and Performance criterion... 11 5.4. EUT Configuration on Test... 11 5.5. Operating Condition of EUT... 11 5.6. Test Procedure... 11 5.7. Test Results... 11 6. RF FIELD STRENGTH SUSCEPTIBILITY TEST... 13 6.1. Block Diagram of Test Setup... 13 6.2. Test Standard... 13 6.3. Severity level and Performance criterion... 13 6.4. EUT Configuration on Test... 13 6.5. Operating Condition of EUT... 13 6.6. Test Procedure... 14 6.7. Test Results... 14 APPENDIX I (MODEL) (1 page) APPENDIX II (TEST DATA) (2 pages) APPENDIX III (EUT PHOTOS) (6 pages) Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 2 of 26

TEST REPORT DECLARATION Applicant : Shenzhen Lisaier Tronics Co., Ltd. Address : NO. 22, Xihu Industrial Park, Xikeng Henggang Town, Longgang District, Shenzhen, China Client No. : 07551996 Manufacturer : Shenzhen Lisaier Tronics Co., Ltd. Address : NO. 22, Xihu Industrial Park, Xikeng Henggang Town, Longgang District, Shenzhen, China EUT Description : Headphone and Earphone Model No. : See Appendix 1 Technical Data : DC 5V Remark : Use 5200/HP do all the tests. Test Procedure Used: EN 55022:2010; EN 55024:2010 ( EN 61000-4-2:2009, EN 61000-4-3: 2006+A2: 2010 ) The device described above is tested by Beide (UK) Product Service Limited to determine the maximum emission levels emanating from the device, the severe levels which the device can endure and EUT s performance criterion. The test results are contained in this test report. Beide (UK) Product Service Limited is assumed of full responsibility for the accuracy and completeness of these tests. This report applies to above tested sample only and shall not be reproduced in part without written approval of Beide (UK) Product Service Limited. Date of Test : Nov. 10-14, 2014 Prepared by : (Jack) Checked by : ( Vivian) Approved by : (Johnson) Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 3 of 26

1.TEST RESULTS SUMMARY Test Results Summary Test Items Test Results 1 Radiation Emission Test PASS 2 Electrostatic Discharge Test PASS 3 Radio Frequency Electromagnetic Field PASS Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 4 of 26

2.GENERAL INFORMATION 2.1.Report Information 2.1.1. This report is not a certificate for quality, it only applies to the sample of the specific product/equipment given at the time of its testing. The results are not used to indicate or imply that they are application to the similar items. In addition, such results must not be used to indicate or imply that BEIDE approves recommends or endorses the manufacture, supplier or use of such product/equipment, or that BEIDE in any way guarantees the later performance of the product/equipment. 2.1.2. The sample/s mentioned in this report is/are supplied by applicant, BEIDE therefore assumes no responsibility for the accuracy of information on the brand names, model number, origin of manufacture or any information supplied. Additional copies of the report are available to the applicant at an additional fee. No third part can obtain a copy of this report through BEIDE, unless the applicant has authorized BEIDE in writing to do so. 2.2.Description of Device (EUT) Description : Headphone and Earphone Model Number : 5200/HP Applicant Manufacturer : Shenzhen Lisaier Tronics Co., Ltd. NO. 22, Xihu Industrial Park, Xikeng Henggang Town, Longgang District, Shenzhen, China : Shenzhen Lisaier Tronics Co., Ltd. NO. 22, Xihu Industrial Park, Xikeng Henggang Town, Longgang District, Shenzhen, China 2.3.Test Facility Site Description Tested by Site Location : Beide (UK) Product Service Limited : 6F, Bldg E, Hourui 3rd Ind Zone, Xixiang, Bao'an Dist, Shenzhen, China 2.4.Test Uncertainty Conducted Emission Uncertainty = ±2.66dB Radiated Emission Uncertainty = ±4.26dB 2.5.Test Condition Test Mode: On Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 5 of 26

2.6.Test Conditions Temperature: 26 Relative Humidity: 63% 2.7.Performance Criterion Performance criterion A: The equipment shall continue to operate as intended during the test. No change of actual operating state (for example change of channel) is allowed as a result of the application of the test. Multifunction equipment shall for each function meet the relevant requirements. Evaluation is carried out for audio and video functions. Performance criterion B: The equipment shall continue to operate as intended after the test. No loss of function is allowed after the test when the apparatus is used as intended. But failures which are recovered automatically but which cause temporary delay in processing, are permissible. No change of actual operating state for example change of channel or stored data and settings is allowed as a result of the application of the test. During the test, degradation of performance is allowed. Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 6 of 26

3.TEST INSTRUMENT USED 3.1.For Radiation Emission Test Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Spectrum Analyzer Rohde&schwarz FSEA20 DE25181 2014.08.18 1 Year 2. Positioning C&C CC-C-1F N/A 2014.08.18 1 Year Controller 3. Trilog Broadband Schwarzbeck VULB9163 9163-333 2014.08.18 1 Year Antenna 4. Horn Antenna Schwarzbeck BBHX9120 9120-426 2014.08.18 1 Year 5. RF Switch EM EMSW18 SW060023 2014.08.18 1 Year 6. Amplifier Agilent 8447F 3113A06717 2014.08.18 1 Year 7. Coaxial Cable Schwarzbeck AK9513 9513-10 2014.08.18 1 Year 8. EMI Test Receiver Rohde&schwarz ESPI 25498514 2014.08.18 1 Year 3.2.For Electrostatic Discharge Immunity Test Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. ESD Tester Noiseken ESS-200AX 0223 2014.08.18 1 Year 3.3.For Radio Frequency Electromagnetic Field Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Signal IFR 2032 203002/100 2014.08.18 1 Year Generator 2. Amplifier A&R 150W1000 301584 2014.08.18 1 Year 3. Dual Directional A&R DC6080 301508 2014.08.18 1 Year Coupler 4. Power Head A&R PH2000 301193 2014.08.18 1 Year 5. Power Meter A&R PM2002 302799 2014.08.18 1 Year 6. Field Monitor A&R FM5004 300329 2014.08.18 1 Year 7. Field Probe A&R FP5000 300221 2014.08.18 1 Year Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 7 of 26

4.RADIATION EMISSION TEST 4.1.Block Diagram of Test Setup 4.2.Test Standard EN 55022:2010 4.3.Radiation Emission Limit All emanations from a Class A computing devices or system, including any network of conductors and apparatus connected thereto, shall not exceed the level of field strengths specified below: FREQUENCY (MHz) DISTANCE (Meters) FIELD STRENGTHS LIMITS (dbμv/m) 30 ~ 230 3 40 230 ~ 1000 3 47 Notes: 1. The tighter limit shall apply at the edge between two frequency bands. 2. Distance refers to the distance in meters between the measuring instrument antenna and the closed point of any part of the EUT. 4.4.EUT Configuration on Test The test Class A regulations test method must be used to find the maximum emission during radiated emission test. The configuration of EUT is same as used in the test. 4.5.Operating Condition of EUT 4.5.1. Setup the EUT as shown on Section 4.1. 4.5.2. Turn on the power of all equipments. 4.5.3. Let the EUT work in test mode (On) and measure it and test it. Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 8 of 26

4.6.Test Procedure The EUT is placed on a turn table which is 0.8 meter above ground. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3 meters away from the receiving antenna which is mounted on a antenna tower. The antenna can move up and down between 1 to 4 meters to find out the maximum emission level. Broadband antenna (calibrated by dipole antenna) are used as a receiving antenna. Both horizontal and vertical polarization of the antenna is set on test. The bandwidth setting on the test receiver (R&S TEST RECEIVER ESPI) is 120kHz. The EUT is tested in Anechoic Chamber. 4.7.Radiation Emission Test Results PASS Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 9 of 26

5.ELECTROSTATIC DISCHARGE TEST 5.1.Block Diagram of Test Setup 5.1.1. Block Diagram of ESD Test Setup (Direct Discharge) 5.1.2. Block Diagram of ESD Test Setup (Indirect Discharge) 5.2.Test Standard EN 55024:2010 (EN 61000-4-2: 2009) Severity Level 3 for Air Discharge at 8kV Severity Level 2 for Contact Discharge at 4kV Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 10 of 26

5.3.Severity level and Performance criterion 5.3.1. Severity level Level Test Voltage Contact Discharge (kv) Test Voltage Air Discharge (kv) 1. 2 2 2. 4 4 3. 6 8 4. 8 15 X. Special Special Performance criterion: B 5.4.EUT Configuration on Test The configurations of EUT are listed in Section 4.4. 5.5.Operating Condition of EUT 5.5.1. Setup the EUT as shown in Section 4.5. except the test set up replaced by section 5.1. 5.6.Test Procedure 5.6.1. Air Discharge: This test is done on non-conductive surfaces. The round discharge tip of the discharge electrode shall be approached as fast as possible to touch the EUT. After each discharge, the discharge electrode shall be removed from the EUT. The generator is then re-triggered for a new single discharge and repeated 10 times for each pre-selected test point. This procedure shall be repeated until all the air discharge completed. 5.6.2. Contact Discharge: All the procedure shall be same as Section 5.6.1 except that the tip of the discharge electrode shall touch the EUT before the discharge switch is operated. 5.7.Test Results PASS Please refer to the following page. Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 11 of 26

Electrostatic Discharge Test Results Beide (UK) Product Service Limited Date: Nov. 11, 2014 Applicant : SHENZHEN LISAIER TRONICS CO., LTD. Test Date : Nov. 11, 2014 EUT : Headphone and Earphone Temperature : 26 M/N : 5200/HP Humidity : 63% Test Engineer : Jack Test Mode : On Air Discharge: ±8kV For each point positive 10 times and negative 10 times Contact Discharge: ±4kV Location Kind A-Air Discharge C-Contact Discharge Result Slots 20 points A PASS Surface 10 points A PASS HCP 5 points C PASS VCP 5 points C PASS Discharge should be considered on Contact and Air and Horizontal Coupling Plane (HCP) and Vertical Coupling Plane (VCP). Reviewer : Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 12 of 26

6. RF FIELD STRENGTH SUSCEPTIBILITY TEST 6.1. Block Diagram of Test Setup 6.1.1. Block diagram of Test Setup 6.2. Test Standard EN 55024:2010 (EN 61000-4-3: 2006+A2: 2010) Severity Level 2 at 3V/m 6.3. Severity level and Performance criterion 6.3.1. Severity level Level Field Strength V/m 1. 1 2. 3 3. 10 X. Special Performance criterion : A 6.4. EUT Configuration on Test The configuration of EUT is listed in Section 4.4. 6.5. Operating Condition of EUT Setup the EUT as shown in Section 6.1. The operating condition of EUT is listed in section 4.5. Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 13 of 26

6.6. Test Procedure The EUT and its simulators are placed on a turn table which is 0.8 meter above the ground. The EUT is set 3 meters away from the transmitting antenna which is mounted on an antenna tower. Both horizontal and vertical polarization of the antenna are set on test. Each of the four sides of EUT must be faced this transmitting antenna and measured individually. In order to judge the EUT performance, a CCD camera is used to monitor the EUT. All the scanning conditions are as follows: Condition of Test Remarks ---------------------------------------------- ---------------------------------- 1. Fielded Strength 3 V/m (Severity Level 2) 2. Radiated Signal Modulated 3. Scanning Frequency 80-1000 MHz 4. Sweeping time of radiated 0.0015 decade/s 5. Dwell Time 1 Sec. 6.7. Test Results PASS Please refer to the following page. Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 14 of 26

RF Field Strength Susceptibility Test Results Beide (UK) Product Service Limited Date: Nov. 11, 2014 Applicant : SHENZHEN LISAIER TRONICS CO., LTD. Test Date : Nov. 11, 2014 EUT : Headphone and Earphone Temperature : 26 M/N : 5200/HP Humidity : 63% Test Engineer : Jack Frequency Range : 80-1000MHz Test Mode : ON Modulation: AM Pulse none 1 khz 80% Criterion : A Frequency Range: 80-1000MHz Steps 1% 1% Horizontal Vertical Front Pass Pass Right Pass Pass Rear Pass Pass Left Pass Pass Reviewer : Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 15 of 26

APPENDIX I (MODEL NO.) HP-9310, HP-9320, HP-9330, HP-8010, HP-9030, HP-9040, HP-8900, HP-8501, HP-8502, HP-8503, 5100/HP, 5200/HP, 5300/HP, 5400/HP, 5500/HP, 5150/HP, CSHSIER100BL, CSHSIER200BL, CSHSIER300BL, i3, HP-8401V, HP-8801V, HP-8802V, HP-8711V, HP-8712V, HP-8714V, HP-8713V, HP-8715V, HP-8721V, HP-8722V, HP-8723V, HP-8724V, HP-8725V, HP-8601V, HP-8602V, HP-2391V, HP-8731V, HP-2144V, HP-2371V, HP-2390V, HP-2133V, HP-2840V, HP-2850, HP-2338V, HP-2819V, HP-8311V, HP-8810, HP-2900, HP-2761, HP-2762, HP-2763, HP-2764, HP-2777, HP-2780, HP-5600, HP-9010, HP-9020, HP-8510, HP-8520 Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 16 of 26

APPENDIX II (TEST DATA) Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 17 of 26

Job No.: LISAIER Polarization: Horizontal Standard: EN 55022 Power Source: DC 5V Test item: Radiation Test Date: 2014/11/13 Temp.( )/Hum.(%RH): 26 /63%RH Time: EUT: Headphone and Earphone Test By: Model: 5200/HP Distance: 3m Note: Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 18 of 26

Job No.: LISAIER Polarization: Vertical Standard: EN 55022 Power Source: DC 5V Test item: Radiation Test Date: 2014/11/13 Temp.( )/Hum.(%RH): 26 /63%RH Time: EUT: Headphone and Earphone Test By: Model: 5200/HP Distance: 3m Note: Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 19 of 26

APPENDIX III (EUT PHOTOS) Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 20 of 26

Figure 1 RADIATION EMISSION TEST Figure 2 APPEARANCE OF EUT Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 21 of 26

Figure 3 APPEARANCE OF EUT Figure 4 APPEARANCE OF EUT Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 22 of 26

Figure 5 APPEARANCE OF EUT Figure 6 APPEARANCE OF EUT Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 23 of 26

Figure 7 APPEARANCE OF EUT Figure 8 APPEARANCE OF EUT Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 24 of 26

Figure 9 APPEARANCE OF EUT Figure 10 APPEARANCE OF EUT Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 25 of 26

Figure 11 APPEARANCE OF EUT Figure 12 APPEARANCE OF EUT Beide (UK) Product Service Limited Tel: +86-755-27454498 Email: admin@szbeide.com Report No. B-E14116436 Page 26 of 26