GENERAL PENSTOCK OPERATING

Similar documents
Unit 24: Applications of Pneumatics and Hydraulics

Business Philosophy. 15 Reasons Why customers choose Ham Baker HISTORY. Section number and title. Integrity in management Quality of product

A descriptive definition of valve actuators

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.

MECHANICAL PRINCIPLES OUTCOME 4 MECHANICAL POWER TRANSMISSION TUTORIAL 1 SIMPLE MACHINES

Selecting and Sizing Ball Screw Drives

Aluminium systems profile selection

OUTCOME 1 STATIC FLUID SYSTEMS TUTORIAL 1 - HYDROSTATICS

ANSWER KEY. Work and Machines

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

Design Aspects of Robot Manipulators

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE STYLE Consult factory for sizes

Electric Motors and Drives

BUTTERFLY VALVES. An industry leader in underground and in-plant applications. STYLE STYLE Consult factory for sizes

DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS

Mechanical Cylinders

BRAKE SYSTEMS 101. Energy Conversion Management. Presented by Paul S. Gritt

Step 11 Static Load Testing

Mechanical Principles

Experience In Motion. Valtek Spring Cylinder Linear Actuators

Chapter 2 Lead Screws

International Journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

V&A PROCONTROL. Rotary Valve Actuators Pneumatic & Hydraulic On-Off / Control / ESD Double Acting Spring Return All Steel SIL 3

Belt Drives and Chain Drives. Power Train. Power Train

Introduction to Process Control Actuators

Hydraulically actuated clutches and spring-applied brakes clutch/brake combined units

Q&A Session for Advanced Ball Screws 102: Troubleshooting for Design Engineers

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

Up and Running with Autodesk Inventor Professional Simulation in 90 Minutes!

ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP

Product catalogue, pipe and sewer cleaning systems

HOPPER SHAPE KNIFE GATE VALVE

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

CHAPTER 15 FORCE, MASS AND ACCELERATION

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

VT VERES KFT

3 Work, Power and Energy

Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves

Fisher 657 and 667 Diaphragm Actuators

CABLE TENSIOMETER ATTACHMENTS FOR ISO 1000

RUBBER SLEEVE KNIFE GATE VALVE

Introduction to Linear Actuators: Precision Linear Motion Accomplished Easily and Economically

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

Rotary vane steering gear for smaller vessels

OPERATOR S MANUAL SUPPORTED TORQUE CALIBRATION BEAM. Part Number Issue 4 Original Instructions (English)

SERVICE MANUAL. Corpus 3G. Seat system for electric wheelchair

Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column

SELECTION, APPLICATION AND MAINTENANCE

Airplane wing test stand for simulating the airstream. Airbus Deutschland GmbH

SURFACE TENSION. Definition

ATLAS RESISTANCE Pier Foundation Systems

Fric-3. force F k and the equation (4.2) may be used. The sense of F k is opposite

MONDOATHENS BASKETBALL SET (Reference PK110)

Innovative Products For Unique Applications. A Tradition of Excellence. Creative Engineering for Fluid Systems. Earthquake Proof Valves

1.1 DOOR'S SYSTEM INTRODUCTION - IRIZAR'S I6 DOOR SYSTEM

FLUID FLOW Introduction General Description

Manufacturing Equipment Modeling

TEPZZ 8 8 A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (51) Int Cl.: G01N 3/04 ( ) G01N 3/08 (2006.

Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water

Oil Dampers with Fixings on. Both Ends. Damping Engineering Oil Dampers with Fixings on Both Ends. Technical Data

Flash Butt Welding Machines

SOLID MECHANICS DYNAMICS TUTORIAL PULLEY DRIVE SYSTEMS. This work covers elements of the syllabus for the Edexcel module HNC/D Mechanical Principles.

Mechanical Systems. Grade 8 Unit 4 Test. 1. A wheelbarrow is an example of what simple machine? Class 1 lever. Class 2 lever.

UNIT II Robots Drive Systems and End Effectors Part-A Questions

Calculation maximum speed outdoor robot platform: The maximum speed of the outdoor robot platform can be calculated with the formula below.

Water hammering in fire fighting installation

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

Installation Instructions

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear

NAGEL ECO 180 FLEXIBLE HONING SYSTEM

B.TECH. (AEROSPACE ENGINEERING) PROGRAMME (BTAE) Term-End Examination December, 2011 BAS-010 : MACHINE DESIGN

HT3 series Peck Feed Drills, with Equal Drill Time

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Screwdriver Function Module for the automatic Screw-Assembly

M Series Manual Handwheel Gear Actuators for Fisher Butterfly Valves

Solar Tracking Application

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Green Thread Product Data

Formulas for gear calculation external gears. Contents:

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Key Features. Product Overview. Threaded Joint Rate Simulator

F output. F input. F = Force in Newtons ( N ) d output. d = distance ( m )

Design of a Universal Robot End-effector for Straight-line Pick-up Motion

2010 APPLICATION REFERENCE GUIDE

Pipe Cutting and Beveling Clamshells

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE

Hydraulic Control Technology for Wind Turbine Generators

Stability Of Structures: Additional Topics

MECHANICS OF SOLIDS - BEAMS TUTORIAL 2 SHEAR FORCE AND BENDING MOMENTS IN BEAMS

The word teamster today means a truck driver,

Work, Energy and Power

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

PFT Two stage axial fan The high pressure fan for modern boiler plants

SITEMA PowerStroke. Technical Information TI-P12. 1 Function. 2 Applications. Mould Closing Devices series FSKP. Contents

Transcription:

TREBLE R FABRICATIONS UNIT 42 CROSSGATE ROAD PARK FARM INDUSTRIAL ESTATE REDDITCH WORCS B987SN. tel 01527 503 303 fax 01527 503 325 web www.treblerfabrications.co.uk ACTUATOR BEVEL GEAR BOX SPURBOX SQUARE CAP HANDWHEEL PROTECTION TUBE FOOTPLATE BRK T GUIDE BRACKET THRUST HOUSING GENERAL PENSTOCK OPERATING MUFF COUPLING SURFACE BOX PILLAR

Operating Gear All penstock gates require opening and closing by a connecting spindle and operating device. This can be either mounted direct to frame or remotely at coping level. The operating device can be either of the following :. Square Cap. Handwheel. Electric Actuator. Bevel or Spur Gearbox. Hydraulic or Pneumatic Cylinder

NON-RISING STEM APPLICATIONS Operation for Non-Rising stem applications. This series provides an extensive range of operating equipment for Non-Rising Stem applications for use with Penstocks and a wide selection of valves. The operating equipment illustrates typical applications and can be configured to satisfy specific requirements.

Operating Equipment: Non-Rising Stem Applications Option A B C D E F Description Electric Actuator on a floor pillar Bevel Gearbox on a floor pillar Handwheel assembly on a floor pillar Bevel gearbox on a floor pillar with universal couplings Adapter square for tee key operation in surface box Handwheel assembley on a coping bracket Item Description 1 Penstock Unit 2 Non-rising Stem 3 Thrust Assembly 4 Adjustable Guide Bracket 5 Muff Coupling 6 Extension Stem 7 Pillar 8 Coping Bracket (Footplate) 9 Handwheel Assembly 10 Electric Actuator 11 Bevel Gearbox 12 Adapter Square 13 Universal Coupling

RISING STEM APPLICATIONS Operation for Rising Stem Applications. This series provides an extensive range of operating equipment for Rising Stem Applications for use with Penstocks and a selection of Valves. The operating equipment illustrates typical applications and can be configured to satisfy specific requirements.

OPERATING EQUIPMENT: RISING STEM APPLICATIONS Option A B C D E Description Electric Actuator on with clear polycarbonate or steel protection tube on a floor pillar Bevel Gearbox with clear polycarbonate or steel protection tube on a floor pillar Handwheel and thrust assembly with clear polycarbonate protection tube on a floor pillar Hydraulic or pneumatic linear actuator on a floor pillar Handwheel and thrust assembly with clear polycarbonate protection tube on a floor pillar Item Description 1 Penstock Unit 2 Lower rising Stem 3 Adjustable Guide Bracket 4 Muff Coupling 5 Upper rising Stem 6 Pillar 7 Short Floor Stool 8 Coping Bracket (Footplate) 9 Manual Thrust Assembly 10 Electric Actuator 11 Bevel Gearbox 12 Linear Actuator 13 Polycarbonate Protection Tube 14 Steel Protection tube

Penstocks/Sluice Gates TECHNICAL DETAILS AND SPECIFICATIONS Civil Work Loading The thrust generated during opening or closing of the penstock can be transferred to the supporting structure in two ways. 1. Locally in the penstock 2. Remotely at the floor, coping or corbel level. Thrust tubes can be introduced between the operator and the penstock frame to enable the operating thrust to be transferred to the penstock for remote operation. For lower operating duties and smaller sized penstocks wall brackets can be supplied to transfer the thrust to the coping. However, for larger and higher duty penstocks we recommend that a corbel is constructed. Vertical Reactions on Civil Work Installations where operating thrust has to be taken at an independent floor pedestal. The concrete corbel or similar structure to which it is attached, must be designed to withstand the maximum forces transmitted to it by the operating gear. An approximate value for the vertical reaction may be derived from:- Vr = [A (300H + K)] F x 9.81 Where Vr = Vertical reaction (N) A = Area of aperture (m2) H = Head from invert of door/gate (m) K = Penstock/sluice gate factor F = 1 for manual operation or 1.5 for power/gearbox operation. Penstock/Sluice Gate Series K Factor Treble R Fabrications Parallel 125 Treble R Fabrications Adjustable 150 Thrust calculations for loadings on civil structures can generally be supplied on request. Note: When an electric actuator is fitted the vertical reaction is based on the rated torque of the actuator.

Penstocks/Sluice Gates TECHNICAL DETAIL AND SPECIFICATION Operating Thrust The method of calculating the vertical reactions on civil work demonstrated on the previous page is an approximation and satisfactory for the purpose intended. However, calculation of operating torque and thrust must be more precise for determination of actuator or gearbox sizes. The maximum thrust is required from the operator during off-seating and raising the door; this is due to the frictional effect of the adjusters and lifting the mass of the door and stem. In closing, or normally the downward movement of the door, the mass of the door and stem act in the direction of the motion and reduce the force required when compared to the unseating condition. The force required to activate the gate is, in part empirically determined. The mass of the door and stem, the head of water on the door at the centreline of the opening, and the friction of the door against the seats and wedges are required to calculate the force to open the gate. These factors can be presented as follows:- F = 9.81 [f.a.h. + (1.5 P1 + P)]..(Equation 1) F1 =9.81 [f.a.h. + (P1 + P2)] (Equation 2) Where: F = Maximum force (thrust) required to open door, in kilo newtons (KN) F1 = Maximum force (thrust) required to close door, In kilo newtons (KN) f = Friction factor between the door and seats, 0.25 (resilient seals) A = Area of aperture, in metres (M) H = Head of water at door centreline, in metres (M) P1= Mass of door, in tonnes (t) P2 = Mass of stem, in tonnes (t) The friction factor (f) between the door on the seats may be taken as 0.25 for seating and off seating penstocks. The force to overcome the frictional effect of the wedges is accounted for by empirically assigning a factor of 1.5 to the mass of the door. The mass of the door can be provided by the penstock manufacturer; however, as stem mass must be estimated in the initial calculation to determine the thrust. Recalculation will be necessary for an accurate thrust value when the stem diameter has been determined.

Penstocks/Sluice Gates Determination of Stem Diameter Several factors govern the size of electric actuator or gearbox: that is, the thrust, torque, stem diameter etc. When the operating thrust has been determined the maximum (off-seating) value should be used in the stem diameter calculation. The basis of the calculation method is the Euler Column Formula for critical buckling load: - P = C x Pye x Pye x E x A x (r/l)2 Equation 3 Where P = Axial thrust on stem in newtons (N) C = End restraint conditions E = Modulus of elasticity in N/mm2 A = Area of stem in mm2 R = radius of gyration in mm L = length of span between supports in mm Clearly, the, euler Column Formula, equation 3 in the format presented is unsuitable for stem diameter calculation. However, with transposition and manipulation equation 4 can be derived as follows: - D = [64 x P x L x L ] 0.25.Equation 4 [C x Pye x Pye x Pye x E ] Where D = Stem diameter in mm P = Axial thrust on stem in Newton (N) C = End restrain conditions, as value of 2 is recommended l = unsupported length in mm F = Factor of safety (minimum of 5 recommended) E = Modulus of elasticity in N/mm2 Equation 4 will provide a theoretical stem diameter. However, for practical purposes the next largest bar size available should be used. The stem slenderness ration must be less than 200 (.SR < 200), this can be established using equation 5. Unsupported length = 1 or 41 Slenderness ration (SR) = radius of gyration r D..Equation 5 D The radius gyration 4 is valid for circular sections

TECHNICAL DETAILS AND SPECIFICATIONS The unsupported length is the distance between fixed ends of the stem or support bracket spacings ; sufficient spacing should be allowed for the door travel on rising stem applications. Determination of Torque Determination of the operating torque depends on several factors. Some have already been calculated: that is the operating thrust and the stem diameter. To complete the torque calculation the thread lead and profile is required to determine the thread efficiency. Tan oc Thread efficiency e = Tan ( oc + ko..equation 6 Where Lead of thread Tan oc = Pye x effective diameter Equation 7 Tan 1 O = 0.15 for lubricated stems (rising type) or 0.20 for unlubricated stems (non-rising type) 1 K = cos B where.. B = half the included thread flank angle, this is a constant applied to tan 1 o So PL T = 2 Pye e..equation 8 Where T = Torque at stem in Nm P = Total thrust in N L = Lead of thread in metres (m) e = Efficiency of thread. Calculation of the maximum thrust (eq. 1), stem diameter (eq. 4) and the operating torque (eq. 8) enables the size of the actuator or gearbox to be determined. The rated output torque from the operator should be converted to thrust by transposition of equation 8, and the stem diameter confirmed by completing a calculation using equation 4 again. The rated torque can be used for civil work loading calculation with the appropriate factors of safety with increased accuracy over the method demonstrated previously.