Digital M tester. Instruction Manual

Similar documents
Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

User s Manual Before using the inverter, you need to read and save the safety instructions.

How To Use A Power Supply Unit (Upu)

User Guide. 4 wire Earth Resistance Tester Model GRT300

User s Manual AURORA 1.2K/2.2K

DLP-PU/E Instruction Manual

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

TIG INVERTER INSTRUCTION MANUAL

Online UPS. PowerWalker VFI 1000R/1U

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Telefon (+45) Telefax (+45) Installation and operating manual

Product Information Sheet UH28CS-12kV Hi Pot Tester

Manual Ranging MultiMeter

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

FC6 FOOT CONTROLLER OWNER S MANUAL

Instruction Manual for IV-08MTV LCD Color Monitor

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Advantium 2 Plus Alarm

AutoRanging Digital MultiMeter

I STAR COMPUTER CO., LTD

INSTALLATION & SERVICE MANUAL. Display Panel

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

TOA 900 SERIES II MIXER POWER AMPLIFIER

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Adjustment functions for both span and shift have been incorporated

Drayton Digistat +2RF/+3RF

=============================== WARNING

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Water Leak Detection System

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

User's Guide. True RMS Industrial Multimeter

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

RY2 miniature industrial relays

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

How To Read A Pipe From A Sensor

Solid-State Timer H3G

PD 100A. Printing data system

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

T7560A,B,C Digital Wall Module

Power supply unit Model: PAC-SC50KUA

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

ADM1TE 5/30A DIN rail single phase two wire energy meter

ACS-30-EU-EMDR-10-MOD

COLOR VIDEO DOOR PHONE CDV-71BE/D

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

MCR1900 Media Converter 19-Slot Chassis

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

WD-AMX Water Detection Controllers

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Model UT33A: OPERATING MANUAL Table of Contents (1)

12 Volt 30 Amp Digital Solar Charge Controller

Part No. IA Feb USER S MANUAL INSULATION RESISTANCE TESTER TOS7200

is then retained absolutely without interruption.

PowlVac Vacuum Integrity Tester

Basic Specifications. Electrical. EPSON Perfection Color EPSON MatrixCCD TM line sensor. device Effective pixels

LOXONE 12 Channel Amplifier

DAB+ / FM Tuner Model: TU-201

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

Product Information Sheet UH36 Hi Pot Tester

GST301. (Single Protection Zone) Operation Manual

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

10000HXL31/15000HXL31/20000HXL31

Digital Keypad Use s Manual

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

7 FUNCTION DIGITAL MULTIMETER

Model 1756 Test Lead Kit

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

User Manual. Video Doorphone CDV-1020AQ

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

CQM1-SF200/CS1W-SF200

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

USER S MANUAL HSC-24A

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

OPERATION MANUAL. VDA-106A Video Distribution Amplifier. 1 st Edition - Rev.1

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

D/N VANDAL RESISTANT 700TVL VARI-FOCAL IR DOME CAMERA CMR6082X/6082MX3.6 N/P CMR6086X/6086MX3.6 N/P

How To Use A Cdm250 Digital Multimeter

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

UT202A Operating Manual. Contents

Cross-beam scanning system to detect slim objects. 100 mm in

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

GSM HOME SECURITY SYSTEM

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Power source. Input. Contact / Open collector Voltage input (SELECTABLE) AC V DC12-24V AC V. Output indicator

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

Transcription:

MODEL 356A series Digital Mtester Instruction Manual I-01138 TSURUGA ELECTRIC CORPORATION

Contents 1. Preface... 2 1-1 General notes... 2 1-1-1 Inspection... 2 1-1-2 Storage... 2 1-2 Preparations prior to use... 2 1-2-1 Power source... 2 1-2-2 Power source cord... 2 1-2-3 Replacement of fuse... 2 1-2-4 Handing notes... 3 2. Name of parts and functions... 3 2-1 Front panel... 3 2-2 Rear panel... 4 3. Operation... 5 3-1 Power source... 5 3-2 Change-over of measuring range... 5 3-3 Comparator operation... 5 3-3-1 Conditions for comparison... 5 3-3-2 Comparison output... 5 3-3-3 Adjustable range... 5 3-4 Mask time... 5 3-4-1 Adjustable range... 5 3-5 Protective action... 6 3-6 NORMAL mode... 6 3-7 CONTINUE mode... 6 3-8 Manual operation... 7 3-9 Remote operation... 7 4. Measurement... 8 4-1 Measuring method... 8 5. Panel mount use (option)... 9 5-1 Mounting... 9 5-2 Dimension when fitted with escutcheon... 9 6. Specifications... 10 6-1 Model names and measuring range... 10 6-2 General specifications... 10 6-3 External dimensions... Back cover 1. Preface Thank you very much for your purchase of our MODEL 356A. For safety and proper use of the product, please observe the following precautions and read the instructions carefully before the initial operation. 1

CAUTION To avoid break-down, malfunction or shortening the life time of the product, do not use this product in such places where: exposed to rain, water drops or direct sunlight. high temperature or humidity, heavy dust or corrosive gas. affected by external noise, radio waves or static electricity. Do not dismantle or modify the product. The model 356A is the digital megger provided with a comparator function which enables to perform insulation resistance tests of domestic electric appliances or electronic apparatus based on the electric appliances regulations and various foreign regulations. It employs an easy-to-read green LED and is a compact insulation resistance tester with its digital comparator of GOOD/NG judgement speed 0.2 sec. As an escutcheon for panel mounting is available at option, it is easy to mount the tester in the system panel. 1-1 General notes 1-1-1 Inspection Upon receiving the tester, confirm that it corresponds to the specifications and that it has not been damaged during the transportation. If any damage or inconvenience is found, please consult our dealer or us informing of the model number and serial number of the product. 1-1-2 Storage In case of storing the tester for a long time, choose the place with the low ambient humidity and where it is not exposed to the direct sunlight. 1-2 Preparations prior to use 1-2-1 Power source The power source voltage is set to 100VAC at the factory before delivery and it is indicated on the caution plate fitted to the rear panel. When the tester is used as originally set, use it with the power source voltage within 90V~132VAC and frequency 50/60Hz. In case that the tester is used with the power source voltage 180~264VAC, change over the internal selection switch to the 180~264V side, and replace the caution plate [90V~132VAC] with [180~264 VAC] accordingly. Be sure to make a change of selection switch after confirming the power source voltage to use. Also ensure that the power switch is OFF when connecting the power source cord. 1-2-2 Power source cord The plug of power source cord connected to the tester is for 100VAC use. When the tester with 200VAC, replace the plug with appropriate one for 200VAC use. is used 1-2-3 Replacement of fuse A 0.5A power source fuse is mounted at the factory before delivery. In case that the tester is used with the power source voltage 180~264VAC, replace it with an attached 0.25A power source fuse. The power source fuse is housed in the fuse holder on the rear panel. Be sure to unplug the power source cord before replacing the fuse. 1-2-4 Handling notes 1) To avoid an electric shock, do not touch the measuring terminals (EARTH, LINE, GUARD terminals on the front/rear panel) during the test. 2

2) When switching on the main power just after it is switched off, be sure to wait for several seconds before switching it on again. 3) To avoid an electric shock, do not touch the metallic parts of measuring lead during the test. 4) In case of high resistance display, the stability of display becomes bad due to response speed but it is not a defect. 2. Name of parts and functions 2-1 Front panel Fig.2-1 1Power ON/OFF switch (ON/OFF) Switch to power ON or OFF the tester. 2Power display LED (POWER) LED lights on when main power is ON. 3Measuring terminal (EARTH) +side measuring terminal. Connect to the grounded side of the sample when it is grounded. 4Measuring terminal (LINE) -side measurement terminal, connected to the non-grounded side of the sample. 5Measuring terminal (GUARD) Terminal to guard a leak current of LINE. 6Mask volume (MASK) For setting the waiting time for judgement in NORMAL operation mode. It is adjusted by a small minus driver. 7Measuring range change-over switch For change-over of 2 ranges (500V-2000MΩ, 1000V-2000MΩ) 8Display (MΩ) 1999.9 green LED to display the measured resistance value. 9In-measurement light (TEST) Yellow LED lights on when measuring voltage outputs. 10Lower limit setting switch (LOWSET) For setting the lower limit. 11Good judgement display (GOOD) Green LED is lit up when measurement result is good. 3

12Lower limit judgement display (LOW) Red LED is lit up when the display value is at or lower than lower limit value. 13Mode switch (NORMAL/CONTNUE) Change-over switch to select NORMAL or CONTINUE mode. 14Remote switch (REMOTE/MANU) Change-over switch to select remote or manual operation. 15Buzzer Fault warning buzzer. 16Buzzer switch (BUZZ/OFF) Buzzer becomes mute when switch is turned OFF. 17Start switch (START) For starting a test in manual operation mode. 18Reset switch (RESET) For resetting a test in manual operation mode. 2-2 Rear panel Fig.2-2 19Power source cord (AC LINE) 20Fuse holder 0.5A miniature type fuse is used (0.25A for 200V). 21Power source voltage selection switch 100VAC or 200VAC is selected. 22Earth terminal (G) Ground terminal. 23Good judgement contact output (GOOD) When measuring result is good, a contact (1a) turns ON. Contact capacity AC250V, 1A resistive load 24Lower limit judgement contact output (LOW) When the display value is at or lower than the lower limit value, a contact (1a) turns ON. Contact capacity AC250V, 1A resistive load 25Reset input (COM-RST) Input terminal for reset signal of test, in remote operation mode. 26Start input (COM-ST) 4

Input terminal for start signal of test, in auto operation mode. 27Rear measuring terminal (EARTH) Common with3measuring terminal (EARTH) on the front panel. 28Measuring terminal (LINE) Common with4measuring terminal (LINE) on the front panel. 29Measuring terminal (GUARD) Common with5measuring terminal (GUARD) on the front panel. 3. Operation 3-1 Power source After confirming that the power source switch of the tester is OFF, plug the power source cord into the receptacle and turn ON the power source switch. The tester will promptly be ready to operate, but it is recommended to have a pre-heating time for 30 minutes or more. 3-2 Change-over of measuring range The measuring range DC500V-2000MΩ or DC1000V-2000MΩ can be selected by measuring range change-over switch. Note) Do not change measuring range during a test operation. 3-3 Comparator operation It is a digital comparator which compares a display value with the lower limit value. 3-3-1 Conditions for comparison Displayed value Lower limit value... GOOD output Displayed value Lower limit value... LOW output 3-3-2 Comparison output Relay contact output : GOOD, LOW, each 1a contact 250VAC, 1A resistive load Display : Red for LOW, green for GOOD Buzzer : Buzzer sounds at LOW output. (Buzzer sound can be turned OFF by BUZZ switch on the front panel.) 3-3-3 Adjustable range Lower limit: 0~19999, the last digit corresponds to the resolution 0.1MΩ and no decimal point is set. e.g.) To set the lower limit value 10.0MΩ, set the digital switch to 00100. 3-4 Mask time It is a timer to prohibit the comparator operation for a certain time and functions in the NORMAL operation mode. It is set in such measurement of the samples with delay like condenser load etc. as may require the judgement waiting time. Set MASK volume fully to the S side. 3-4-1 Adjustable range 0.1~10.0 sec. 3-5 Protective action It notifies abnormality without lighting TEST LED on in case of: 1) making EARTH terminal short-circuit to GUARD terminal. 2) abnormality of measuring voltage. 3-6 NORMAL Mode In this operation mode, when the judgement becomes LOW during the measurement, the tester holds 5

the judgement result and display value, and shuts down the measuring voltage, then ends the measurement. To start the measurement, press start switch to output the measuring voltage and to activate mask timer. During the mask timer operation, comparator does not operate. To end the measurement, shut down the measuring voltage by reset switch, and reset the judgement result and display value. In case of the measurement ended with LOW judgement, start the measurement again after reset. Timing chart 3-1 3-7 CONTINUE Mode In this operation mode, the measurement continues without shutting down the measuring voltage, even if the LOW judgement is made during the measurement. To start the measurement, press start switch to output the measuring voltage and to activate mask timer. To end the measurement, shut down the measuring voltage by reset switch, and reset the judgement result and display value. In this operation mode, MASK timer does not work. Timing chart 3-2 6

3-8 Manual operation When REMOTE switch is at MANU side, it is in the manual operation mode. During the manual operation, start or end the test with START switch or RESET switch on the front panel. Operating procedures Set REMOTE switch at MANU side. Set NORMAL or CONTINUE mode by mode switch. Select the measuring range by measuring range change-over switch. Set BUZZ switch OFF on necessity.. Set the lower limit value with the digital switch of the comparator. Turn the power source switch ON. Test (1) To start a test, switch start switch ON. (2) Applying the measuring voltage to the measuring terminal, start the measurement. (3) To end a test, switch reset switch ON. 3-9 Remote operation When the remote switch on the front panel is at the REMOTE side, it is in the remote operation mode. During the remote operation mode, start or end the test by ST or RST terminals at terminal block on the rear panel Operating procedures Set REMOTE switch at REMOTE side. Set the NORMAL or CONTINUE mode by mode switch. Select the measuring range by measuring range change-over switch. Set BUZZ switch OFF on necessity. Set the lower limit value with the digital switch of comparator. Turn the power source switch ON. Test. (1) To start a test, switch ST (start signal) ON (min. width 10ms). (2) Applying the measuring voltage to the measuring terminal, start the measurement. (3) To end a test, make RST (reset signal) ON (min. width 10 ms) Fig.3-1 7

4. Measurement 4-1 Measuring method (1) Connect the earth lead (black) plug into EARTH terminal, the line lead into (red) LINE terminal respectively. When getting the probe in contact with the sample, the insulation resistance is displayed. (2) When measuring the insulation resistance of the sample grounded, measure it by connecting the grounded side to EARTH terminal. (3) GUARD terminal is used when the fluctuation of display value is big due to the influence of leak or inductive current. Also, the volume or surface resistance of the cables, insulation materials and etc. can be measured by using GUARD terminal. Fig.4-1 (4) As the measuring terminal on the front panel and the measuring terminal on the rear panel are internally connected, use either measuring terminal. Both measuring terminals can not be used simultaneously. 5. Panel mount use (option) 8

5-1 Mounting When the tester is used by mounting in the panel (console), use the optional escutcheon and mounting brackets. Fig.5-1 Remove the feet (4 parts) from the bottom of the tester. Fix the panel mount attachments to the escutcheon with M36 flat tight screws. Fix the panel mount attachments to the both side of the tester with M48 binding screws. Insert the tester from the front of the panel and fix it to the panel with mounting brackets. Note) In case of mounting the tester to a chassis using the taps for fixing the feet at the bottom of the tester, the length of screw needs 6 + thickness of the chassis (mm). If the length of the screw is too long, it will touch the printed circuit board and which fact causes malfunction. 5-2 Dimensions when fitted with escutcheon 6. Specifications 6-1 Model names and measuring range Fig.5-2 9

Model name 356A Measuring range Measuring range Mean value Accuracy 0~199.9 MΩ (2%rdg. +3digit) DC500V/2000MΩ 200.0~1000.0 MΩ 50MΩ (3%rdg. +8digit) 1000.1~1999.9 MΩ (5%rdg. +8digit) 0~199.9 MΩ (2%rdg. +3digit) DC1000V/2000MΩ 200.0~1000.0 MΩ 50MΩ (3%rdg. +8digit) 1000.1~1999.9 MΩ (5%rdg. +8digit) Accuracy: 23 o C5 o C, 45~75%RH 6-2 General specifications Applicable standard Conformity with JIS C1302-1994 Voltage with no load +30%, -0% of rated voltage or less Rated measuring current 1mA Short circuit current 12mA or less 0~19999 green LED (character height 14.2mm) Display Auto zero suppress function Flashing with 1999.9 at over-range or open input Sampling rate 10 times/sec. Display response within 0.2 sec. * Note 1 Setting for lower limit value, digital comparison system Comparator Adjustable range : 0~19999 Judgement time : within 0.2 sec. * Note 2 Judgement display : Red for LOW, Green for GOOD Judgement output : LOW, GOOD, each 1a contact Contact capacity - 250VAC, 1A (resistive load) Judgement buzzer Electronic buzzer for LOW, NG. Buzzer OFF function provided Mask timer 0.1~10.0 sec. Insulation resistance Terminals - Enclosure : 1000VDC 100MΩ or more Case - Power source, input/output : 2000VDC for 1 min. Withstanding voltage terminals, control input, relay terminals Power source - Input/output terminals, : 1500VAC for 1 min. control input Power source 100VAC (90~132V) or 200VAC (180~264V) 50/60Hz *Note 3 Power consumption approx. 15VA Operating ambient temperature 0~50 o C Storage temperature -20~70 o C Weight approx. 1.2 kg Diameter 206(W)74(H)179(D)mm Accessories 1 Measuring lead 1 Power source fuse 0.25A 1 Instruction manual Note 1: Time required for the value to reach the rated accuracy when the mean value resistance is suddenly connected to the open measuring terminal. Note 2: Time required to make a judgement operation when the judgement value is set to the mean value and the open measuring terminal is suddenly short-circuited. Note 3: The tester can be used at 100VAC or 200VAC by change-over switch on the rear panel of the tester. 6-3 External dimensions 10

Fig.6-1 11