PicoScope 6407 Digitizer

Similar documents
PicoScope 6000A/B Series

PicoScope 2200A Series PC OSCILLOSCOPES WITH ARBITRARY WAVEFORM GENERATOR

PicoScope 3000 A and B Series

PicoScope 3000 Series

PicoScope CHANNELS 12 BIT RESOLUTION. HIGH-PRECISION PC OSCILLOSCOPE 256 MS BUFFER MEMORY LOW COST PORTABLE

NEW PRODUCT ANNOUCEMENT

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

Oscilloscopes 3 Oscilloscope Overview 6 PicoScope Software 8 PicoScope 2000 Series 12 PicoScope 3000 Series 17 PicoScope 4000 Series 20 PicoScope

Embest DSO2300 USB Oscilloscope

Arbitrary/Function Generators AFG3000C Series Datasheet

How To Use A High Definition Oscilloscope

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

PicoScope 5000 Series (A API)

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

U1602A Handheld Oscilloscopes, 20 MHz

RF Measurements Using a Modular Digitizer

AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz

USB DrDAQ. USB DrDAQ: Making Data Logging Fun! VERSATI LE DATA AC QU I S ITI O N.

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Lab 1: The Digital Oscilloscope

ECONseries Low Cost USB DAQ

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

M4i.66xx-x8-16 bit 1.25 GS/s Arbitrary Waveform Generator

Analogue/Digital Analogue and Differential Oscilloscopes

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

User s Guide DSO-2150 USB PC Based Digital Oscilloscope Operation Manual

MODEL INDEX ADS1152CA ADS1102CA ADS1062CA ADS1022C

Description: Multiparameter System (4 or 8 channels)

FREQUENCY RESPONSE ANALYZERS

NI USB-5681 RF Power Meter Specifications

Agilent 8904A Multifunction Synthesizer dc to 600 khz

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

ADC-20/ADC-24 Terminal Board. User Guide DO117-5

This document lists the specifications for the NI PXIe-5160, 500 MHz digitizer.

Impedance 50 (75 connectors via adapters)

RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc.

R&S ZNBT8 Vector Network Analyzer Specifications

MATLAB Instrument Driver

LogicLab s.r.l Via della valle Carate Brianza (MI) Tel Fax

Agilent E5100A Network Analyzer

PicoScope 6 Self-Help Guide

Current Monitoring Kit QUICK START GUIDE

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal.

Current Monitoring Kit

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Gage Applied Technologies

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

AlazarTech SDK Programmer s Guide. Version May 28, 2010

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps

Agilent Technologies 3000 Series Oscilloscopes

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

AFG-100/200 series USB Modular Arbitrary Function Generator. Date: Oct, 2014

R&S ZNC Vector Network Analyzer Specifications

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

Oscilloscope Fundamentals Primer

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

DAC Digital To Analog Converter

Multi-Range Programmable DC Power Supplies 9115 Series

Digital Storage Oscilloscopes Models 2540B, 2542B, 2540B-GEN, 2542B-GEN

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

Ideal for high dynamic range measurements from compression to noise floor

DataSheet. SHS800 Series Handheld Digital Oscilloscope SHS820/SHS815/SHS810/SHS806. Application Domain

FFT Spectrum Analyzers

DataSheet. SHS1000 Series Handheld Digital Oscilloscope SH1102/SHS1062. Features & Benefits

Multi-Range Programmable DC Power Supplies 9115 Series

Cond-IS RF Conducted Immunity System

Figure 1: Multiple unsynchronized snapshots of the same sinusoidal signal.

USB-QUAD08. Eight-channel Quadrature Encoder Input Device. Specifications

1701/22 FieldMonitor Management Interface Module

USB Smart Power Sensor

User Manual. CFG253 3 MHz Function Generator

User Manual. TDS 200-Series Digital Real-Time Oscilloscope

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Type-D EEG System for Regular EEG Clinic

Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance

POCKET SCOPE 2. The idea 2. Design criteria 3

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Signal and Tracking Generator

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station І

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

AlazarTech SDK Programmer s Guide. Version June 16, 2011

US-Key New generation of High performances Ultrasonic device

Power Amplifier Gain Compression Measurements

Automotive. Aerospace. bout Us. Defense. Energy. Maritime. Education. Electronics. and more

R&S ZVA Vector Network Analyzer Specifications

ugrid Testbed. Rein in microgrid complexity. With ease.

Waveform Monitor Audio & Loudness Logging

khz to 2.7 GHz Spectrum Analyzer

Diagnostics Tools. for All Makes of agricultural machinery

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Transcription:

YE AR PicoScope 6407 Digitizer HIGH PERFORMANCE USB DIGITIZER Programmable and Powerful 1 GHz bandwidth 1 GS buffer size 5 GS/s real-time sampling Advanced digital triggers Built-in function generator USB-connected Signals Analysis On The Move www.picotech.com

Introduction to the 6407 Digitizer High-speed data acquisition The is a compact USB plug-in device that turns your PC or laptop into a high-speed digitizer. It can easily digitize a 1 GHz sine wave with a timing resolution of 200 ps. Huge buffer memory The PicoScope 6407 digitizer has a memory depth of 1 billion samples. Other digitizers have high maximum sampling rates, but without deep memory they cannot sustain these rates on long timebases. The PicoScope 6407 can sample at 5 GS/s at timebases all the way down to 20 ms/div, giving a total acquisition time of 200 ms. If that s not enough, the driver supports streaming mode for capturing unlimited gap-free data directly to the PC s RAM or hard disk at over 10 MS/s. The large buffer enables the use of segmented memory. Each captured waveform segment is stored in the buffer so you can rewind and review thousands of previous waveforms. No longer will you see a glitch on the screen only for it to vanish before you stop the scope. Advanced triggers As well as the standard range of triggers found on all oscilloscopes, the PicoScope 6407 offers a comprehensive set of advanced triggers including pulse width, windowed and dropout triggers to help you capture the data you need. Digital triggering Most digital oscilloscopes sold today still use an analog trigger architecture based around comparators. This can cause time and amplitude errors that can not always be calibrated out. The use of comparators often limits the trigger sensitivity at high bandwidths and can also create a long trigger re-arm delay. Since 1991 we have been pioneering the use of fully digital triggering using the actual digitized data. This reduces trigger errors and allows our oscilloscopes to trigger on the smallest signals, even at the full bandwidth. Trigger levels and hysteresis can be set with great precision and resolution. Digital triggering also reduces re-arm delay and this combined with the segmented memory allows the triggering and capture of events that happen in rapid sequence. At the fastest timebase you can use rapid triggering to collect 10,000 waveforms in under 20 milliseconds. Our mask limit testing function can then scan through these waveforms to highlight any failed waveforms for viewing in the waveform buffer. Arbitrary waveform and function generator The unit has a built-in function generator (including sine, square, triangle, ramp, sin (x)/x, Gaussian, half-sine, white noise, DC level, and PRBS). As well as basic controls to set level, offset and frequency, more advanced controls allow you to sweep over a range of frequencies. Combined with the spectrum peak hold option, this makes a powerful tool for testing amplifier and filter responses. Also included is a full arbitrary waveform generator with a 16k-sample buffer. High-end features as standard To protect your investment, both the API and the firmware inside the unit can be updated. We have a long history of providing new features for free via software downloads. Other companies make vague promises about future enhancements but we deliver on our promises year after year. Users of our products reward us by becoming lifelong customers, frequently recommending us to their colleagues. High signal integrity Most oscilloscopes are built down to a price; ours are built up to a specification. Careful front-end design and shielding reduces noise, crosstalk and harmonic distortion. Years of oscilloscope experience enable us to achieve improved pulse response and bandwidth flatness. We are proud of the dynamic performance of our products and publish these specifications in detail. The result is simple: when you probe a circuit, you can trust in the data you capture. Supplied with a full SDK SDK compatible with Windows XP, Windows Vista and Windows 7 Example programs available as part of the SDK Free Technical Support available

Specifications VERTICAL Number of Channels 4 Input connectors SMA Bandwidth (-3 db) 1 GHz Rise time (calculated) 350 ps Resolution 8 bits (12 bits with software enhancement) Input impedance 50 Ω ±2% VSWR < 1.5:1 DC to 1 GHz typical over full bandwidth of scope Input coupling DC Input sensitivity 20 mv/div (10 vertical divisions) Input ranges ±100 mv DC accuracy ±3% of full scale Overvoltage protection ±2 V (DC + Peak AC) HORIZONTAL Sampling rate (real time 1 Channel) 5 GS/s Sampling rate (real time 2 Channels) 2.5 GS/s (using A+C, A+D, B+C, B+D) Sampling rate (real time 4 Channels) 1.25 GS/s Sampling rate (cont. USB streaming) 1 MS/s in PicoScope software. >10 MS/s using supplied SDK (PC-dependent) Buffer memory 1 GS Waveform buffer (no. of segments) 1 to 10,000 Timebase accuracy ±5 ppm DYNAMIC PERFORMANCE (typical) Crosstalk 100:1 DC to 100 MHz 30:1 100 MHz to 1 GHz Step response ±3% after 3 ns, typical Noise <0.5 mv RMS TRIGGER Basic trigger modes Rising, falling Advanced digital triggers Edge: Single edge or dual edge with adjustable hysteresis Window: signal enters or exits a user-defined voltage range Pulse width: a negative or positive pulse is wider or narrower than a set width, or inside / outside a range of widths Window pulse width: signal is inside or outside a voltage range for a set time Dropout: signal does not cross a voltage threshold for at least a set time Window dropout: signal does not enter or exit a voltage range for at least a set time Interval: time between two edges is greater or less than a set time, or inside / outside a time range Logic: arbitrary logic state of Channels A, B, C, D and AUX matches a user-defined pattern Runt pulse: signal crosses one voltage threshold and returns without crossing the other Trigger sensitivity (Ch A, Ch B) Digital triggering provides 1 LSB accuracy up to full bandwidth of scope Max. pre-trigger capture Up to 100% of capture size Max. post-trigger delay Up to 4 billion samples Trigger re-arm time < 1 µs on fastest timebase Max. trigger rate Up to 10,000 waveforms in a 20 ms burst AUX TRIGGER/CLOCK INPUT Trigger types Edge, pulse width, dropout, interval, logic, delayed Input characteristics Rear panel BNC, 50 Ω ±1% Voltage range ±5 V, DC coupled Bandwidth (AUX TRIGGER) 25 MHz Threshold adjustment range ±1 V Overvoltage protection ± 5V Frequency Range (CLOCK INPUT) 5 MHz to 25 MHz

Technical Specifications Continued... SIGNAL GENERATOR Standard output signals Sine, square, triangle, ramp, sin (x)/x, Gaussian, half-sine, white noise, DC level, PRBS Standard signal frequency DC to 20 MHz Output frequency accuracy ±5 ppm Output frequency resolution < 0.1 Hz Output voltage range (Pk to Pk) ±250 mv to ±2 V (into high impedance load) Offset voltage adjustment ±1 V (max. combined output ±2.5 V) Amplitude flatness 1.5 db DC to 20 MHz, typical Connector type Rear panel BNC Overload protection ±5 V Sweep modes Up, down, dual with selectable start/stop frequencies and increments AWG Sample rate 200 MS/s Buffer size 16,384 samples Resolution 12 bits Bandwidth 20 MHz Rise time (10-90%) 10 ns, typical GENERAL PC connectivity USB 2.0 Power requirements 12 V DC, 3.5 A supply Dimensions 255 x 170 x 40 mm (including connectors) Weight < 1 kg Temperature range Operating: 0 C to 40 C (20 C to 30 C for stated accuracy) Safety approvals Designed to EN 61010-1:2010 EMC approvals Tested to EN61326-1:2006 and FCC Part 15 Subpart B Environmental approvals RoHS and WEEE compliant Software/PC requirements PicoScope 6, SDK and example programs. Microsoft Windows XP, Vista or Windows 7 (32-bit or 64-bit). Have you seen our PicoScope 6000 Series data sheet? It shows the full range of features available with the PicoScope software, which turns your into a powerful oscilloscope and spectrum analyzer. All of these capabilities are included in the price of your digitizer.

Connections DC power input USB AWG and function generator output Ch A Ch B Ch C Ch D The four SMA input connections on the front of the allow four signals to be sampled. Various attenuators can be fitted to these connections to allow a wider range of signals to be measured on the device. AUX trigger/reference Clock input Your PP795 product pack contains the following items: USB cable Quick Start Guide Software and Reference CD Carrying case (pictured right) Ordering Information ORDER CODE PART DESCRIPTION GBP USD* EUR* PP795 5995 9895 7255 TA077 Attenuator 3 db, 50 ohm SMA to SMA 30 50 37 TA078 Attenuator 6 db, 50 ohm SMA to SMA 30 50 37 TA140 Attenuator 10 db, 50 ohm SMA to SMA 30 50 37 TA141 Attenuator 20 db, 50 ohm SMA to SMA 30 50 37 TA061 Oscilloscope probe 1.5 GHz, x10, 50 ohm, SMA 199 329 241 www.picotech.com Pico Technology, James House, Colmworth Business Park, St. Neots, Cambridgeshire, PE19 8YP, United Kingdom T: +44 (0) 1480 396 395 F: +44 (0) 1480 396 296 E: sales@picotech.com *Prices are correct at the time of publication. Please contact Pico Technology for the latest prices before ordering. Errors and omissions excepted. Copyright 2011 Pico Technology Ltd. All rights reserved. MM027.en-3