USB-TG44A Tracking Generator User Manual

Similar documents
Field Calibration Software

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

HP 8970B Option 020. Service Manual Supplement

Agilent 8753ET/8753ES Network Analyzers

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Agilent PN RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

Impedance 50 (75 connectors via adapters)

User's Guide. Integrating Sound Level Datalogger. Model Introduction

DSA800 Series Spectrum Analyzer

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

khz to 2.7 GHz Spectrum Analyzer

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

FREQUENCY RESPONSE ANALYZERS

AVerMedia AVerKey imicro User s Manual

VME IF PHASE MODULATOR UNIT. mod

SEE2 UV150 QUICK INSTALL GUIDE

PERF10 Rubidium Atomic Clock

USB Smart Power Sensor

A Guide to Calibrating Your Spectrum Analyzer

Calibration Guide. Agilent Technologies ESG Vector Signal Generator

Amplified High Speed Fiber Photodetectors

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Agilent E5100A Network Analyzer

Understanding Mixers Terms Defined, and Measuring Performance

AN1991. Audio decibel level detector with meter driver

Site Master Cable and Antenna Analyzer with Spectrum Analyzer

R&S ZNC Vector Network Analyzer Specifications

USB Smart Power Sensor

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

User's Guide Integrating Sound Level Datalogger Model

Signal and Tracking Generator

iva Cable & Antenna Analyzer

USB Smart Power Sensor

VM-4 USB Desktop Audio Device Installation Guide

MoCA 1.1 Specification for Device RF Characteristics

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

VM-8 USB Desktop Audio Device Installation Guide

R&S ZNBT8 Vector Network Analyzer Specifications

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. B

User Manual. CFG253 3 MHz Function Generator

Power Amplifier Gain Compression Measurements

M2M Cellular Signal Amplifier

Designing the NEWCARD Connector Interface to Extend PCI Express Serial Architecture to the PC Card Modular Form Factor

R&S ZCxxx Millimeter-Wave Converters Specifications

Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer

How To Use A Sound Card With A Subsonic Sound Card

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices

R&S SMZ Frequency Multiplier Specifications

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

USB Focus Motor Controller User Manual Model FCUSB

HYDRA Z Owner s Manual

A Low Frequency Adapter for your Vector Network Analyzer (VNA)

LabelWriter. Print Server. User Guide

iva Cable & Antenna Analyzer

GPS 35 USB. installation and quick start guide

LT-82 Stationary IR Transmitter

Spectrum Analyzers And Network Analyzers. The Whats, Whys and Hows...

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer

Universal Wireless Effects Controller USER S GUIDE SA115

RF Communication System. EE 172 Systems Group Presentation

OMNIYIG. .5 TO 2 GHz, 1 TO 4 GHz, 6 to 18 GHz Thin Film YIG-TUNED OSCILLATORS OUTLINE DIMESIONS MOUNTING SURFACE GND +15V + TUNE - HTR HTR

DCX300 - DCX400 - DCX600

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

Installation and Operation Manual. for the. IPC-1, Bi-Directional stereo level matching interface

Experiment 7: Familiarization with the Network Analyzer

9,'(2 #6(3$5$725 8VHU V#0DQXDO

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Dolphin 9900 Mobile Computers

Agilent 8720 Family Microwave Vector Network Analyzers

MACTek Corporation. USB HART Interface. Users Manual

RF Network Analyzer Basics

Network Analyzer Operation

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Agilent Test Solutions for Multiport and Balanced Devices

A Network Analyzer For Active Components

PIR-1 Owner s Manual

Installation & User Manual

High Power Amplifier Measurements Using Agilent s Nonlinear Vector Network Analyzer

Model: HD11-ARC. Installation Guide

Handheld Spectrum Analyzers, 3.3 GHz & 8.5 GHz Models 2650A, 2652A, 2658A

R&S ZVA Vector Network Analyzer Specifications

IVIS IVIS - Indoor Video Insertion System

HA5. HDMI To HD-SDI/SDI Video and Audio Converter User Manual

Dual-Cool Notebook Cooler Pad. User s Manual

0HDVXULQJWKHHOHFWULFDOSHUIRUPDQFH FKDUDFWHULVWLFVRI5),)DQGPLFURZDYHVLJQDO SURFHVVLQJFRPSRQHQWV

Agilent PN Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth

2. The Vector Network Analyzer

AN437. Si4432 RF PERFORMANCE AND FCC COMPLIANCE TEST RESULTS. 1. Introduction. 2. Relevant Measurements to comply with FCC

Video Splitter VS-104 / VS-108 User's Manual

We reserve the right to make technical changes.

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

ELECRAFT KX3 EXTENDED VFO TEMPERATURE COMPENSATION PROCEDURE Copyright 2012 Elecraft LLC Rev. A8, October 27, 2012

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Transcription:

USB-TG44A Tracking Generator User Manual

Signal Hound USB-TG44A User Manual 2015, Signal Hound, Inc. 35707 NE 86th Ave La Center, WA 98629 USA Phone 360.263.5006 Fax 360.263.5007 This information is being released into the public domain in accordance with the Export Administration Regulations 15 CFR 734 2

Contents 1 Preparing For Use... 1 1.1 INITIAL INSPECTION... 1 1.2 SOFTWARE INSTALLATION... 1 2 Getting Started... 2 2.1 THE USB-TG44A FRONT & REAR PANELS... 2 3 Taking Measurements... 3 3.1 MEASURING INSERTION LOSS OR GAIN... 3 3.1.1 Improving Accuracy... 4 3.1.2 Testing High Gain Amplifiers... 4 3.1.3 Measuring Insertion loss > 80 db... 4 3.2 MEASURING RETURN LOSS... 4 3.2.1 Adjusting an Antenna... 5 4 Theory of Operation... 5 5 Troubleshooting... 5 5.1.1 General Troubleshooting Procedure... 6 5.1.2 General Advice to avoid problems... 6 6 Calibration and Adjustment... 6 7 Specifications... 7 7.1 FREQUENCY... 7 7.2 AMPLITUDE... 7 7.3 SPECTRAL PURITY... 7 7.4 INPUTS AND OUTPUTS... 7 7.5 ENVIRONMENT... 7 7.6 CALIBRATION... 7 7.7 ADJUSTMENTS... 8 8 Revision History... 8 9 Warranty and Disclaimer... 8 9.1.1 Warranty... 8 9.1.2 Warranty Service... 8 9.1.3 Limitation of Warranty... 8 9.1.4 Exclusive Remedies... 9 9.1.5 Certification... 9 3

9.1.6 Credit Notice... 9 4

Preparing For Use INITIAL INSPECTION 1 Preparing For Use Unpacking your Tracking Generator and Installing Software The Signal Hound USB-TG44A is a USB-based 10 Hz to 4.4 GHz economy tracking generator that works with the USB-SA series and BB60C spectrum analyzers, facilitating scalar network analyzer measurements. The Signal Hound USB-TG44A is powered from the USB cable, eliminating the need for a separate power supply. Measuring less than 8 inches long and weighing only ten ounces, the Signal Hound can be used virtually anywhere! 1.1 INITIAL INSPECTION Check your package for shipping damage before opening. Your box should contain a USB cable, a CD- ROM, an SMA M-M adapter, a 3' BNC cable, and a Signal Hound USB-TG44A. 1.2 SOFTWARE INSTALLATION The USB-TG44A uses the same Spike software as your Signal Hound spectrum analyzer. No additional software installation is required. Additionally, there is a small standalone utility for using your USB- TG44A without a USB-SA44B or USB-SA124B. 1

Getting Started THE USB-TG44A FRONT & REAR PANELS 2 Getting Started Learn about the basic functions and features of your Signal Hound Tracking Generator The primary use for the USB-TG44A tracking generator is to form a scalar network analyzer when paired with the USB-SA44B spectrum analyzer and the Spike software. The insertion loss of filters, amplifiers, cables, and attenuators can be measured quickly and accurately from 10 Hz to 4.4 GHz. By adding a directional coupler, return loss can be measured as well. The Spike software is set up to sweep active devices, such as amplifiers, and passive devices, such as filters and attenuators. By default, high dynamic range is selected, which typically offers 90 db of dynamic range (0 to -90 db for passive devices, +20 to -70 db for active devices, or +40 to -50 db for active devices with a 20 db fixed attenuator). High dynamic range sweeps take about ½ second for a 100 point sweep (span > 100 khz). For crystals or other very high Q circuits, a second operating mode is available. This narrow-band mode is selected automatically when your span is 100 khz or less. In this mode, a 100 point sweep takes about 7 seconds, but the sweep updates at each point. See the Spike Software User Manual for more information. 2.1 THE USB-TG44A FRONT & REAR PANELS The front panel includes a 50Ω SMA RF input. Do not apply signal or DC to this port. It is a DC-coupled output. Applying DC or signals in excess of +20 dbm will cause damage. A READY / BUSY LED flashes orange each time a command from the computer is processed. The rear panel has three connectors: 1. 10 MHz Reference output. Used in the legacy software for some modes requiring 0 ppm frequency error. 2. A USB type B connector. Connect to your PC using the included USB cable. 3. TG Sync. Connect to the USB-SA44(B) Sync Out port for all spans of greater than 100 khz. 2

Taking Measurements MEASURING INSERTION LOSS OR GAIN 3 Taking Measurements Learn how to take path loss, amplifier gain, and mixer gain/loss measurements The Signal Hound USB-TG44A Tracking Generator (TG), combined with the USB-SA44B Spectrum Analyzer (SA) and Spike software, is capable of making a wide range of scalar network analysis measurements. Whether you are tuning an RF filter, sweeping an amplifier to plot gain, or verifying a step attenuator, measurements are quick and easy with the USB-TG44A tracking generator. 3.1 MEASURING INSERTION LOSS OR GAIN The Signal Hound USB-TG44A Tracking Generator may be used to measure insertion loss or gain. To measure insertion loss of a cable or attenuator, the following approach is recommended: 1. Plug the spectrum analyzer and tracking generator devices into the PC using the supplied USB cables. 2. Connect the spectrum analyzer and tracking generator nose-to-nose using the SMA barrel connector provided. 3. Connect the TG Sync to the spectrum analyzer Sync Out. 4. Launch the Spike software. 5. Set start / stop / center / span frequencies to desired sweep range 6. Set your reference level to +10 dbm. This will place the zero insertion loss line one division from the top of the graticule. 7. Select Analysis Mode > Scalar Network Analyzer 8. Select your ideal sweep size. This will help the software determine step size (the frequency step between measurements). 9. If your device is passive (e.g. attenuator, filter, or cable), select Passive Device. For amplifiers with gain of up to 20 db, select Active Device and change your reference level to +20 dbm. 10. If you wish to double the sweep speed and cut the dynamic range in half, un-check High Range. 11. With the spectrum analyzer and tracking generator still connected nose-to-nose, wait for a complete sweep to finish. Then click Store Thru. This will correct for the amplitude offsets 3

Taking Measurements MEASURING RETURN LOSS between the TG and SA, and give you a stable line at 0 db insertion loss. Note: If you change any settings after Store Thru, repeat this step. 12. (Optional) For maximum accuracy below -45 db, insert a fixed attenuation of 20 to 30 db, and then click Store 20 db Pad. The actual attenuation used can be anywhere from 20 to 30 db, and will be factored out automatically. This corrects for small offsets between the higher range and lower range readings. This is only used for settings of High Range, Passive Device. If you omit this step, accuracy below -40 db should be treated as +/- 1 db typical. 13. Insert the device to test and take measurements. 3.1.1 Improving Accuracy One shortcoming of the Signal Hound Spectrum Analyzer and Tracking Generator is poor VSWR / return loss performance. However, this can be easily overcome by adding good 3 db or 6 db pads (fixed SMA attenuators) to the output of the tracking generator and / or the input of the spectrum analyzer. A good 6 db pad will improve return loss by nominally 12 db to >20 db, and should enable accurate measurements relative to a 50 ohm system. These may be included when sweeping the "thru," effectively nulling them out. This will decrease your overall dynamic range. 3.1.2 Testing High Gain Amplifiers When measuring an amplifier that will have gain of 20 to 40 db, the use of a 20 db pad is required. Simply insert the 20 db pad before you Store Thru, and leave the pad on either the SA or TG when connecting to the amplifier. For amplifiers with Psat>+20 dbm, the pad should go on the output of the amplifier. If an amplifier cannot safely handle -5 dbm, place the pad on the amplifier s input. 3.1.3 Measuring Insertion loss > 80 db To measure more than 80-90 db insertion loss, you will need to use Utilities > Tracking Generator Control. Set your frequency to the desired test frequency, and set the amplitude to -10 dbm. Find the CW signal using the USB-SA44B at about a 100 khz span. Decrease your span down to about 10 khz, keeping the signal centered, then reduce your RBW to 10 Hz or 100 Hz, depending on the dynamic range required. With a 10 Hz RBW, your noise floor will generally show about 140 db of insertion loss. This method is especially good for tuning notch filters where your ultimate rejection at a specified frequency may need to be 100 db or greater 3.2 MEASURING RETURN LOSS A directional coupler of appropriate frequency range (sold separately) may be used to make approximate return loss measurements. Connect your tracking generator to the "OUT" port, and connect your spectrum analyzer to the "COUPLED" port. Use the "IN" port as your S-parameter test port. Sweep this setup as the "thru" with the test port open (reflecting 100% of power). Then connect your device to test (e.g. antenna) to the "IN" port. Return loss or S11 will be displayed. 4

Theory of Operation MEASURING RETURN LOSS Once again, measurement accuracy will benefit from 3 to 6 db pads on the Signal Hound devices. This method is not as accurate as using a precision vector network analyzer with a full two port calibration, but with a good directional coupler, measurements from 0 to -20 db should be accurate. 3.2.1 Adjusting an Antenna To adjust an antenna for a certain frequency, it is often sufficient to simply maximize return loss at that frequency. This may be done in a swept or CW tracking generator mode. Mount your antenna and ground as you normally would, then connect to the "IN" port as above. Lengthen, shorten, and tweak impedance matching elements until the desired return loss is achieved. Be aware that you will be radiating some RF during this process. It is your responsibility to understand and obey laws regarding transmitting on those frequencies. 4 Theory of Operation Learn about the internal blocks that make up the Signal Hound Tracking Generator The Signal Hound Tracking Generator is built around a 32-bit programmable modulus direct digital Synthesizer (DDS). This allows the firmware to set precise 10 Hz steps. The DDS generates frequencies from 10 Hz to 28 MHz directly. To produce higher frequencies this signal is multiplied by an integer from 5 to 200. Below 28 MHz, the output has low harmonic content. However, above 28 MHz, harmonics are generated and not filtered. Typically, harmonics as high as -10 dbc will be observed for much of the RF spectrum. For use as a tracking generator, the presence of harmonics has very little impact on the measurement, since the harmonics will generally be well outside the spectrum analyzer's input bandwidth. However, when verifying the output power level with an RF power meter, the harmonic content can add up to 0.7 db to the measured output. Please note that the phase noise of the USB-TG44A is higher than the USB-SA44. However, this will have minimal impact on readings as out-of-band energy is rejected by the spectrum analyzer. 5 Troubleshooting There is a known intermittent power-on problem with the USB-TG44A. The remedy is to simply unplug the USB, count to 10, then plug it back in. If you repeatedly experience this power on problem, contact Test Equipment Plus for repair or replacement. 5

Calibration and Adjustment MEASURING RETURN LOSS 5.1.1 General Troubleshooting Procedure 1. Unplug the USB cable from your Tracking Generator, count to 10, and plug it back in. If the LED is green, proceed. Otherwise, try a different USB port or cable. Verify the USB-SA44(B) spectrum analyzer is plugged in to USB as well. 2. Launch the application software. Set your spectrum analyzer to SPAN 100 KHz, CENTER FREQ 10 MHz. 3. Connect the TG RF output to the spectrum analyzer RF input. 4. Check for a 10 MHz output from the TG between -20 and -25 dbm. This is the default power on state. 5. If no signal is present, repeat steps 1-4. If there is still no signal, contact technical support at http://www.signalhound.com 6. Verify that the TG SYNC is connected to the SYNC out of the spectrum analyzer using a BNC cable. Connect the TG and spectrum analyzer nose-to-nose using the SMA barrel connector. 7. Analyzer. In 1-2 seconds you should see a trace near 0 db +/- 4 db. If you do not see this and your TG LED is red, verify your SYNC cable. If the cable is damaged, replace it. If sections of the sweep are missing, your TG likely needs repair. Otherwise, contact technical support at http://www.signalhound.com 5.1.2 General Advice to avoid problems Unplug your USB-TG44A from the USB port when not in use, or before shutting down your computer. For maximum stability, a 15 minute warmup is recommended for sensitive measurements. 6 Calibration and Adjustment Contact Test Equipment Plus for more information regarding calibration software and required equipment. 6

Specifications FREQUENCY 7 Specifications 7.1 FREQUENCY Frequency range Frequency Accuracy Frequency steps 10 Hz to 4.4 GHz ±1ppm 19 selectable step sizes from 10 Hz to 10 MHz 7.2 AMPLITUDE Amplitude range Absolute Amplitude accuracy Amplitude steps -30 to -10 dbm ±2.0 db 1 db 7.3 SPECTRAL PURITY Harmonics Typically < -10dBc 7.4 INPUTS AND OUTPUTS BNC Timebase Output (10 MHz output) BNC TG Sync SMA RF Output 7.5 ENVIRONMENT 20 C to 25 C to achieve published specifications 0 C to 70 C safe operating range with derated amplitude specifications 7.6 CALIBRATION Test with factory calibration software to verify that USB-TG44A is operating within tolerance. Recommended calibration interval is 1 year at 20 C to 25 C. 7

Revision History ADJUSTMENTS 7.7 ADJUSTMENTS Factory adjustment software shall be used to generate new calibration constants when USB-TG44A will not pass calibration. 8 Revision History Version 3.00 Initial release under the Spike software 9 Warranty and Disclaimer Copyright 2015 Signal Hound. All rights reserved Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. 9.1.1 Warranty The information contained in this manual is subject to change without notice. Test Equipment Plus makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties or merchantability and fitness for a particular purpose. Test Equipment Plus shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This Test Equipment Plus product has a warranty against defects in material and workmanship for a period of one year from date of shipment. During the warranty period, Test Equipment Plus will, at its option, either repair or replace products that prove to be defective. 9.1.2 Warranty Service For warranty service or repair, this product must be returned to Test Equipment Plus. The Buyer shall pay shipping charges to Test Equipment Plus and Test Equipment Plus shall pay UPS Ground, or equivalent, shipping charges to return the product to the Buyer. However, the Buyer shall pay all shipping charges, duties, and taxes, to and from Test Equipment Plus, for products returned from another country. 9.1.3 Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper use by the Buyer, Buyersupplied software or interfacing, unauthorized modification or misuse, operation outside of the environmental specifications for the product. No other warranty is expressed or implied. Test 8

Warranty and Disclaimer ADJUSTMENTS Equipment Plus specifically disclaims the implied warranties or merchantability and fitness for a particular purpose. 9.1.4 Exclusive Remedies The remedies provided herein are the Buyer s sole and exclusive remedies. Test Equipment Plus shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory. 9.1.5 Certification Test Equipment Plus certifies that, at the time of shipment, this product conformed to its published specifications. 9.1.6 Credit Notice Windows is a registered trademark of Microsoft Corporation in the United States and other countries. 9