Significance of Vibration Diagnosis of Rotating Machines during Commissioning: Few Case Studies

Similar documents
PeakVue Analysis for Antifriction Bearing Fault Detection

Pump Vibration Analysis

APPENDIX F VIBRATION TESTING PROCEDURE

Shaft. Application of full spectrum to rotating machinery diagnostics. Centerlines. Paul Goldman, Ph.D. and Agnes Muszynska, Ph.D.

Mobile field balancing reduces vibrations in energy and power plants. Published in VGB PowerTech 07/2012

export compressor instability detection using system 1* and proficy** smartsignal software

Interactive Computer Based Courses

Online Hydro Machinery Monitoring Protection, Prediction and Performance Monitoring Solutions

Case Studies on Paper Machine Vibration Problems

Vibration Analysis Services. FES Systems Inc. 1

PERPLEXING VARIABLE FREQUENCY DRIVE VIBRATION PROBLEMS. Brian Howes 1

Vibration Monitoring: Envelope Signal Processing

Machine diagnosis: Quick and easy through FFT analysis

Practical On-Line Vibration Monitoring for Papermachines

GMC 2013: Piping Misalignment and Vibration Related Fatigue Failures

Vibration analysis: what does it mean?

Pump Skid Fabrication for Magnetic Coupling. Rick Soltis Chief Mechanic City of Bedford

Highly flexible couplings

ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES

Oil and Coolant Circulating Heating System. Model - OCSM

ALERT AUTOMATED DIAGNOSTIC SOFTWARE

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

EXPERIMENTAL RESEARCH ON CHARACTERISTICS OF CENTRIFUGAL PUMP NOISE IN WATER PIPE SYS- TEM

Measurement Types in Machinery Monitoring

Reference Standards for Vibration Monitoring and Analysis

Testing Capabilities. Worldwide Designers & Manufacturers of Air Moving Equipment

Adaptive feature selection for rolling bearing condition monitoring

Coal Handling Plant Alignment Standards For Shaft To Shaft Alignment. By Makarand Joshi M.Tech

Mechanical &Electrical Research Institute, National Water Research Center, Delta Barrage, Egypt.

Troubleshooting accelerometer installations

Spectrum Analysis. The key features of analyzing spectra. Summary. By Jason Mais SKF USA Inc.

due to uncertainty. This, in turn, has a direct impact on equipment availability and maintenance costs. Unfortunately, due to misconceptions and

Loewe GK Installation and operating manual

Oil & Gas. CHTR Centrifugal, High-pressure, Multistage Barrel Pump to API 610, 10 th Edition.

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

Pumps 101: Operation, Maintenance and Monitoring Basics

TECHNICAL INFORMATION Bulletin

Increase System Efficiency with Condition Monitoring. Embedded Control and Monitoring Summit National Instruments

TECHNICAL INFORMATION Bulletin

What to Look for in a Vibration Consultant By Alan Friedman, DLI Engineering. Introduction. The Most Basic Form of Vibration Analysis

Unit 24: Applications of Pneumatics and Hydraulics

Selecting and Sizing Ball Screw Drives

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

CASE HISTORY #2. APPLICATION: Piping Movement Survey using Permalign Laser Measurement System

Mechanical Design Concepts for Non-Mechanical Engineers

Pipe Cutting and Beveling Clamshells

Vibration Diagnostics by Expert Systems that Link to Machinery Databases

SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006

COMPUTATIONAL TOOLS FOR SIGNAL PROCESSING APPLICATIONS FROM INDUSTRY AND BIOINFORMATICS 02/2006

SUSPENSION AND STEERING OVERVIEW

Schaeffler UK Training Courses

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Stuart Gillen. Principal Marketing Manger. National Instruments ni.com

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Field Application Note

Similar benefits are also derived through modal testing of other space structures.

MEMBRANE VACUUM MINI PUMPS

PUMP VIBRATION STANDARDS GUIDELINES

Calibrating a Large Compressor s Rotordynamic Model: Method and Application

Design and Modeling of Fluid Power Systems ME 597/ABE 591 Lecture 5

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

STUDY OF DAM-RESERVOIR DYNAMIC INTERACTION USING VIBRATION TESTS ON A PHYSICAL MODEL

13 common causes of motor failure

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

APPLICATIONS FOR MOTOR CURRENT SIGNATURE ANALYSIS

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Vibration Analysis Survey Report

WHAT IS INFRARED (IR) THERMOGRAPHY

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

Bearing Stiffness Determination through Vibration Analysis of Shaft Line of Bieudron Hydro Powerplant

Technical Data. 7. Bearing Fits. 7.1 Interference. 7.2 Calculation of interference F B LLLLLLLLL( A-54

Q&A Session for Advanced Ball Screws 102: Troubleshooting for Design Engineers

Rexroth Hydraulic Pump A10VO Series User Manual

AC-Synchronous Generator

7.3 Fit selection. Inner ring: Rotating. Outer ring: Stationary. Inner ring: Stationary. Outer ring: Rotating. Inner ring: Stationary

4" SUBMERSIBLE PUMPS

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

Hydrate Occurrence in Centrifugal Compressor Systems

Single-Phase AC Synchronous Generator

Vertical Multistage Centrifugal Electric Pumps SV Series NEW LASER TECHNOLOGY

REMOTE CONDITION MONITORING SYSTEM FOR A HYBRID WIND-DIESEL SYSTEM APPLICATION AT FERNANDO DE NORONHA ISLAND, BRAZIL

INDUSTRIAL KILN & DRYER GROUP KILN & DRYER ROLLER ADJUSTMENTS

SJT / SJM / SJP Large Vertical Pumps

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Dampers. Inlet guide vane. Damper. Louvre damper. Handbook Radial Fans / Chapter 3 - Dampers REITZ List 2010 DO 1. Dampers

Arun Veeramani. Principal Marketing Manger. National Instruments. ni.com

THE COMPOSITE DISC - A NEW JOINT FOR HIGH POWER DRIVESHAFTS

The use of Operating Deflection Shapes (ODS) to model the vibration of sanders and polishers HSL/2006/104. Project Leader: Author(s): Science Group:

Vibration Analysis of P - 29 Motor-Pump Assemblies

EXAMINER 1000 Vibration Meter Electronic Stethoscope

ALIGNMENT PITFALLS - HOW TO IDENTIFY AND ELIMINATE THEM

Document Title Press Maintenance Checklist used in performing routine maintenance on punch presses

ROTATING MACHINES. Alignment & Positioning of. Fast, easy and accurate alignment of rotating machines, pumps, drives, foundations, etc.

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

Reliability. The Essentials of Eliminating Downtime of your Electric Motor. Asset Management? Or, Maintenance Management, Re-branded?

Belt Drives and Chain Drives. Power Train. Power Train

On-line Machine Condition Monitoring [The CMS System]

Transcription:

National Symposium on Rotor Dynamics (NSRD-2003), December 15-17, 2003, IIT, Guwahati, India Significance of Vibration Diagnosis of Rotating Machines during Commissioning: Few Case Studies Jyoti K. Sinha Vibration Laboratory, Reactor Engineering Division, Bhabha Atomic Research Centre, Mumbai 400 085 ABSTRACT Satisfactory operation of any machine is always important for plant safety, increased productivity, and low downtime and maintenance overhead. Such requirements could usually be fulfilled by proper design and installation of machines at site. Design part is perhaps more matured in most cases, however installation may play a significant role in the dynamic behaviour even for properly designed machines. Vibration based condition monitoring and codes are well known and widely followed for most of the conventional rotating machines like Pumps, Motors, Turbines, etc. However many rotating machines often used in different process and power plants are not of conventional type wherein condition monitoring is also important, but the codes and the diagnostic techniques may not directly be applicable. The vibration measurements and analysis during commissioning is important to resolve the problems related to the machine installation, if any, and identify the parameters for future condition monitoring of different kinds of machines. It has been experienced that the vibration diagnosis during commissioning gives significant information about the proper installation vis-à-vis the vibration parameters to look for and the locations of measurements for future condition monitoring. The paper presents few such case studies on conventional and unconventional rotating machines. * Corresponding Author. Tel.: +91-22-25591501/02; fax: +91-22-25505151 Email address: vilred@magnum.barc.ernet.in

1. INTRODUCTION Rotating machinery used in practice can be classified into two categories Conventional and Unconventional. The machines often seen, for examples Electric Motors, Centrifugal pumps, Electric Generators, Turbines, etc. are herein referred as Conventional machines. Any other class of rotating machines used in different processing and power plants are not of conventional types, are referred as Unconventional machines. The proper design, assembly and installation are always needed to cater the optimal design performance as well as to enhance plant safety, increased productivity, and low downtime and maintenance overhead. In fact the vibration based condition monitoring techniques (Goldman and Muszynska, 1999, Sinha, 2002, Rao, 2000) and various international codes giving the guidelines for vibration assessment are widely accepted and used to meet the above objectives for the conventional machines. The Vibration Handbook by Harris (1988) gives a brief summary of different standards and codes on vibration severity limits for machines, and Parkinson and McGuire (1995) give the recent revisions in these standards. However, the application of these techniques and codes may not be straightforward for the unconventional machines. Nevertheless condition monitoring for such machines is also important. The rotating machine mainly consists of three major components namely rotor, bearing and foundation that include connecting piping and structures as well. In general, it has been observed that the design of the rotor and bearings are matured enough for the conventional machines, and may be for the unconventional machines for any intended application. So the problem in the machine due to rotor and to an extent in bearing is highly unlikely to exist. Even if some faults occur in the rotor and/or bearing over a period of operation, it can be identified using vibration based signal analysis which is well developed in the field of rotor dynamics for machines (Goldman and Muszynska, 1999, Sinha, 2002). However if the problem is due to improper installation of machine at site then the foundation structure needs to be investigated for the satisfactory performance of complete machine assembly. Considering these problems, vibration measurement and analysis during commissioning is important to resolve the problems related to the machine installation, if any, and to identify the parameters for future condition monitoring of different kinds of machines. It has been experienced that the vibration diagnosis during commissioning gives significant information about the proper installation vis-à-vis the vibration parameters to look for and the locations of measurements for future condition monitoring. In the present paper, few case studies on both the conventional and unconventional type of rotating machines are discussed.

2. CONVENTIONAL ROTATING MACHINES The vibration based condition monitoring for the operating conventional rotating machines are matured and usually the following measurements and analysis procedures are adopted for monitoring the health of machines. (a) Overall vibration measurements as per International Standard Codes (Harris, 1988, Parkinson and McGuire, 1995). (b) If the vibration amplitudes of machine exceed the severity limit as per codes, usually orbit plot, amplitude and phase plot, waterfall plot, Bode plot, etc. are looked into during normal and transient machine operation to identify the faults so that remedial action could be taken in a planned shut-down. The above analysis generally identify the rotor related problems like unbalance, mis-alignment, bend, crack, rub, etc. and the fluid bearing related oil whirl and whip. The deterioration in the anti-friction bearings is monitored by crest factor or/and by kurtosis value of the measured responses at bearing pedestals (Bendat and Piersol, 1985, Rao, 1999). The envelope, or more precisely the amplitude demodulation at the carrier frequency (usually the rotating speed of the machine) of the measured responses at bearing pedestal normally locate the exact nature of faults by identifying the bearing characteristic natural frequencies (Harris, 1988, Barkov et al., 1995a & b). These defects may develop due to the change in process parameters and/or over a long period of machine operation. However if the defects are arising due to improper machine installation, more precisely due to foundation dynamics, the above analysis will only identify the defects, and can be rectified before any catastrophic break-down. But such defects will frequently reoccur in machines because the root causes for such recurrence are often not identified adequately by the above analysis. Hence it is good to resolve such problems by conducting modal tests and vibration diagnosis during machine operation at the time of site commissioning. Two case studies on different class of the centrifugal pumps are discussed here. 2.1. CASE STUDY # 1 Figure 1 shows the schematic of the assembly of motor-pump and foundation structure. The motor-pump assembly rests on the top of three steel blocks (attached together by bolts) on either side. The pump is situated at the top of the motor. As shown in Figure 1 the motor and pump units are hung on their support. Total support height is 1.81 m and the length of the pump-motor

unit is 1.75 m which is anchored to the foundation at about 1m from the bottom of the motor. The nominal diameter of the shaft is 100 mm and supported through three bush bearings. The motor-pump shaft has a six bladed impeller at the top. Figure 2 shows the piping layout of the two pumps for both suction and discharge. The pump has an axial suction and a radial discharge pipe of 200mm OD. The suction and discharge lines for Pump 2 are 3 times lengthier than in Pump 1. Suction Line Discharge Line Bearing Shaft z x (parallel to discharge) y Pump Motor Supporting Blocks Figure 1 A schematic of the pump assembly Heat Exchanger Suction Pipe To Research Reactor Discharge Pipe z y Pump 2 x Pump 1 Figure 2 Piping layout for Pump 1 & 2

2.1.1. Vibration Diagnosis The pump can be operated at 1500 RPM or 3000 RPM depending upon the requirements. During commissioning stage the vibration measurements on the motor-pump assembly were carried out at site when pumps were operating at 1500 RPM. Vibration amplitudes for both the pumps were found to be well within the severity limit as per Hydraulic Institute Standard (1983). However Pump 2 was found to have relatively high overall vibration and with sub and higher harmonics of the rotating speed frequency peak (25 Hz) in the spectrum compared to Pump 1. A typical waterfall spectrum for both pumps at pump casing is shown in Figure 3. The waterfall spectrum consists of two startup events of the pump. The modal tests using the impulse-response method (Ewins, 2000) were then conducted on both the pump assemblies to explain their dynamic behaviour observed during the pump operation. The identified first few natural frequencies for Pump 1 are 23.76Hz, 31.81Hz, 37.76Hz, 45.58Hz and 59.69Hz, and the frequencies at 21.92Hz, 25.80Hz, 32.77Hz, 34.99Hz, 45.14Hz and 49.65Hz are identified modes for Pump 2. Suryam, Sinha and Rao (2003) gave the details of the vibration measurements, modal tests and their results. Since both pumps are supported on similar foundation, the difference in the identified modes for Pump 1 and 2 are suspected to be due to difference in suction and discharge lines. Figure 3 The waterfall spectrum in x-direction at pump casing ((A) Pump 1, (B) Pump 2) 2.1.3. Discussion It was observed from the pump dynamics during operation and test modal data that Pump 1 can be operated at 1500 RPM and 3000 RPM as there were no structural modes close to these speeds. However Pump 2 was not safe to operate at either speeds as these speeds are close to its structural modes at 25.80 Hz and 49.65 Hz. Moreover, Pump 2 also showed significant frequency components at 0.5X, 1.5X (near to critical speed 34.99Hz), 2X (near to critical speed

49.65Hz) and 6X (vane passing frequency) other than the operating speed of 25Hz (1X) in comparison to Pump 1. Frequency peak at 12.5Hz (0.5X, where X is rotating speed) is usually due to looseness in bearing assembly or due to gyroscopic effect (Bosmans, 1982). Other cause for 0.5X is due to shaft whirl which is unlikely for the pump, as there is no oil film journal bearing (Sinha, 2002). The possibility of the bearing looseness was unlikely as the pumps were recently assembled. So it could be due to the gyroscopic effect (Bosmans, 1982). The strong component at 0.5X in the Pump 2 indicates more influence of the gyroscopic effect than the Pump 1. This could be explained as the pump is operating close to one of its critical speed 25.80Hz, and so the motor-pump assembly is oscillating at its cantilever type foundation, and hence the combined effect of the shaft rotation and deformation of the entire assembly could result in this pronounced gyro effect. This effect was small in Pump 1 as it was operating slightly above the critical speed. Since in Pump 2 the gyroscopic effect is prominent and operating close to the critical speed 25.80Hz, the varying gap between the impeller and casing will be more that could cause higher hydraulic loading which leads to high vane passing frequency component in Pump 2 compared to Pump 1. High 2X component is also due to the existing critical speed at 49.65Hz compared to Pump 1. Based on the observation made, it was recommended to either rigidly support the bottom part of the motor or provide rigid support to the discharge and suction lines near pump casing to shift these structural modes for Pump 2. However Pump 1 does not require any modification. 2.2. CASE STUDY # 2 The moderator system of the nuclear power plant under study consists of five vertical pumps with four in operation and one available as a standby. Figure 4 shows the schematic of the layout of the pumps and piping. The pump assembly is shown in Figure 5(a). A vibration survey carried out during commissioning showed normal vibration on top of the motors (i.e., farthest location from the pump base) as per the Hydraulic Institute Standard (1983) but high vibration on the pump casing. The direction of high vibration was specific for each pump: N-S for Pump 2 & 4, and E-W for Pump 1 & 5. Pump 3 had low vibration in both directions. It may be noted that the inlet and outlet piping are similar for Pumps 2 & 4, and for Pumps 1 & 5. If the vibration assessment had been carried out strictly as per the Hydraulic Institute Standard (1983), all the pumps are considered to be healthy, however high casing vibration was not acceptable. This has been investigated and corrected.

Figure 4 Schematic layout of Pumps and Piping (a) Pump Assembly (b) Mode shapes Figure 5 Schematic of the Pump assembly and its mode shapes

2.2.1. Vibration Diagnosis The vibration spectrum of the pump consists mainly of the pump speed component (1X) i.e., 3000RPM, and hence not indicating any possible cause for high casing vibration. The modal tests were then conducted on pump assemblies by the impulse-response method (Ewins, 2000). The modal test results indicated that first two cantilever beam modes of the pump assembly were 20.3Hz and 54.7Hz in the N-S direction, and 12.5Hz and 76.5Hz in the E-W direction for Pump 2 & 4, whereas these modes were 17.2Hz and 53.1Hz in the E-W direction, and 11Hz and 76.5Hz in the N-S direction for Pump 1 & 5. The mode shapes for these modes in orthogonal directions for Pump 2 are shown in Figure 5(b). The anti-node for the second mode was observed to be located on the pump casing. Since the operating speed was close to the second mode, high casing vibration was observed during pump operation. Rao, Sinha and Moorthy (1991, 1997) gave the details of measurements and analysis. 2.2.3. Discussion and Solution The natural frequency close to 3000RPM (50Hz) for the pump assemblies were changed by additional stiffening of the pump stool by welding a thick plate on each side on the stool. The support to the discharge piping of the pump was also strengthened with additional U bolts. With these modifications, the casing vibration was reduced significantly. So far none of the pumps reported to have any problems since they have been commissioned in 1991. 3. UNCONVENTIONAL ROTATING MACHINES Many rotating machines often used in different process and power plants are not of conventional type where condition monitoring is also important, but the codes and the diagnostic techniques may not directly be applicable. In such cases it is important to carry out vibration measurements and diagnosis during commissioning so that the problem related to machine s natural frequency and RPM can be avoided, and moreover, the measured dynamic behaviour during commissioning can be preserved for future comparison and diagnosis. Two such case studies are discussed below. 3.1. CASE STUDY # 1 The Turbo-dryer is an equipment in which wet chemical in paste form is dried under high temperature and forced air circulation. Figure 6 shows the schematic of the dryer unit. The shaft of the tray unit and the turbo fan are coaxial and are driven by independent drives. They rotate in

opposite direction at 1/6 RPM and 33 RPM respectively. The shafts of the tray unit and fan are supported on bottom foundation through the carbon bush type thrust bearings. The tray shaft carries a number of trays at a number of stages. The tray and fan assemblies are housed in an octagonal casing which is supported independently on horizontal I-beams. The wet charge is continuously fed from the top and removed from the bottom as dry powder. The casing consists of a number of heaters, and.a number of levelers/ scrapers at each stage of the trays to maintain the level of powder/ paste in the tray by sweeping the excess charge to the lower stage trays. Finally the dry powder is taken out from the bottom of the casing. The dryer unit had a major breakdown after about 10 months of trouble free operation since commissioned in 1990. Large scale damages were seen to its internal structures. The unit was put back into operation after a few modifications. However the operators were cautioned to putoff the dryer whenever a loud noise and vibration occurred. CHEMICAL PASTE OCTAGONAL CASING LEVELER/ SCRAPER TRAY FAN Figure 6 Schematic of the Turbo-dryer

3.1.1. Vibration Diagnosis Vibration measurements were carried out in 1991. Vibration levels at different locations were found to be low at the start of the machine, and the operation was quiet and smooth. However with time the vibration level was found to be increasing, as well as the rubbing noise was also heard. The rubbing noise seems to be originating from an area close to the thrust bearings. The FFT analysis of the vibration signal indicates an occurrence of a dominating peak around 12Hz. Further investigation revealed that the casing with its support had a natural frequency near 12Hz which is close to fan motor speed of 710 RPM. The shaft rubbing with bearings were confirmed by the shaft vibration measurements using proximity probes. Hence the thrust bearings have been suspected to have provided the transmission path to cause the resonance of the casing at the motor RPM. The phase relationship between the lower foundation and the casing supports at 12 Hz was also found to be out-of-phase by 180 degree, hence closing the gap between the trays and levelers/scrapers. Since the casing and its supports are lightly damped structure, the gap closing may cause damage in the tray and leveler if the machine operated for long period. Rao, Sinha and Moorthy (1991) gave the details of measurements and analysis. 3.1.2. Discussion and Solution A similar machine in another unit of the plant had no such severe history of the failure. There was no rubbing noise and no appreciable vibration level. Detailed investigation revealed that the gap between the tray and leveler was more resulting in minimal chance of direct interference during operation. Secondly the casing structure is directly supported on the floor by eight vertical pillars and so the natural frequency would be much higher eliminating any possibility of resonance. For the present machine it was observed that there was no severe vibration during first few minutes of the machine start up, and there was no 12Hz component seen in the spectrum shown in Figure 7(a). It only indicates that there was no resonance during this period. However when the machine continued operation for longer period, a dominant peak at 12Hz with its harmonic observed as shown in Figure 7(b) with high rubbing noise indicating the phenomena of resonance. Such phenomena could only occur if there may be small shift in the casing natural frequency. It was suspected that there was no powder hold up at the bottom of the casing during machine start up resulting in a slightly natural higher frequency, however when the operation progresses the powder hold up increases which takes that natural frequency close to the fan motor RPM. The operation personnel further confirmed this suspicion.

One possible solution to reduce the machine vibration level was to increase the gap between the tray and leveler and to change the motor speed to avoid resonance, but these changes were a little involved, and hence not adopted. Alternatively, it was suggested to provide few additional supports like pillars from the floor to increase the frequency of the casing support. The later solution was implemented. After this no major breakdown has been reported in the Turbo-dryer after the support modification. 0.562Hz (FAN RPM) (a) Just after machine startup 12Hz (FAN MOTOR RPM) (b) During resonance at 12Hz Figure 7 Measured dynamic behaviour of the Turbo-dryer

3.2. CASE STUDY # 2 The Pilger mill is a combination of both rotating and reciprocating machine tool for rolling a small length of tube to the required size and wall thickness by applying compressive stresses during each stroke of the machine. The tube is fed progressively during each stroke to form the complete length. The schematic of the Pilger mill is shown in Figure 8. The crankshaft of the mill has five split roller bearings as indicated in figure. Two bearings are mounted on each of the crankpins, and one is mounted on the center pin, which has been deleted in the figure. One of the two bearings mounted on each crankpin is for the connecting arm of the roll-stand (designated as RSB) and the other bearing is for the balancing weight (designated as BWB). The two crankpins are identified as Operator side and Flywheel side. It was reported that the Operator side BWB has been failing frequently since the machine was commissioned in 1990. It had failed thrice within a period of 2 years. The root cause of this repeated failure was investigated by vibration measurements during normal operating conditions in the year 1992. Figure 8 The Pilger Mill 3.2.1. Vibration Diagnosis Vibration signals were picked up by the piezo-electric accelerometers on all the four bearings (as marked in Figure 8) at the full speed of 277.5 RPM of the crankshaft. The dynamic responses of the balancing weight on the Operator and Flywheel sides are shown in Figure 9 for comparison.

From the time waveforms, it appears that the balancing weight and its connecting arm on the Operator side is not moving freely. The piezo-electric accelerometer could pick up the propagated stress waves due to impact. The vibration signals were processed through an audio system. The audio output supports the above postulation of the obstruction to the free movement of the balancing weight on the Operator side. The bent in the connecting arm was suspected as one of the reason for such time waveform. The site further confirmed this suspicion of the bend. Sinha et al. (1992, 1996) gives the details of the measurements and analysis carried out for this identification. Figure 13 The dynamic response of balancing weight 3.2.2. Discussion and Solution During maintenance, the bent connecting arm was replaced by new arm, and the machine was put back into service in 1992. Since then, the machine has been working satisfactorily. Few more new machines of similar kinds were installed and commissioned in 1995. They were also put into operation after a certification from the vibration diagnosis by comparing the dynamic behaviour with respect to the Pilger mill (Meher et al., 1995), and none of them reported to have any breakdown so far.

4. CONCLUDING REMARKS In general, the conventional vibration based condition monitoring techniques used in rotating machines are important and useful in prediction of deterioration in different components so that the defects can be rectified either by replacing the defective components or by repair well in advance before any major breakdown. However if the failure of components is frequent and repeated in nature and particularly when it is occurring due to some kind of resonance, the conventional condition monitoring may not be suitable to identify the root cause in many cases except for identification of deterioration. Hence considering all these limitations, it is always important to carry out details vibration measurements and diagnosis including the dynamic characterization by modal tests during installation and commissioning of machines to avoid many unknown sources of vibration related problems. This has already been brought out through few case studies on different kind of machines. It has been observed that once the root cause of vibration is removed, machines are operating smoothly for years together without any major problem. In fact, each case study is also indicative of the vibration parameters to look for and the locations of measurements for future condition monitoring. For example Measurement of the natural frequencies of machine assembly over a period of machine operation, vibration measurement at casing for the vertical pump of the Case Study # 2, vibration measurement at bearings of the Pilger Mill, etc. Hence it can be concluded that if a machine is being installed and commissioned with such precautions, then the machine will operate smoothly, and its aging related problems, if any developed over a period of operation, can then be well taken care by the conventional condition monitoring to enhance the safety and availability of the machine. ACKNOWLEDGEMENTS All the staff members of the Vibration Laboratory, RED, BARC, Mumbai are acknowledged. REFERENCES Barkov, A., Barkova, N., Mitchell, J.S., 1995a. Condition Assessment and Life Prediction of Rolling Element Bearings Part 1. Journal of Sound and Vibration 29(1), 10-17. Barkov, A., Barkova, N., Mitchell, J.S., 1995b. Condition Assessment and Life Prediction of Rolling Element Bearings Part 2. Journal of Sound and Vibration 29(1), 27-31. Bendat, J.S., Piersol, A.G., 1985. Random Data: Analysis and Measurement Procedures. 2 nd edition, NY: Wiley. Bosmans, R. F., 1982. Detection and early diagnosis of potential failures of rotating machinery. Report L0411-00 (2/82), Bently Nevada Corporation, USA.

Ewins, D. J., 2000. Modal Testing Theory, Practice and Application. Research Studies Press, U.K., 2 nd Edition. Goldman, P., Muszynska, A., 1999. Application of Full Spectrum to Rotating Machinery Diagnostics. Orbit, pp 17-21, Bently Nevada Corporation, USA. Harris, C.M. (Editor), 1988. Shock and Vibration Handbook. 3 rd edition. NY: MaGraw-Hill. Hydraulic Institute Standard for Centrifugal, Rotary and Reciprocating Pumps, 1983. 14 th Edition, Hydraulic Institute. Meher, K.K., Rajput, N.B.S., Sinha, S.K., Moorthy, R.I.K., 1995. Vibration Assessment of the Condition of 25 VMR Pilger Mills. BARC Report Ref. No.- RED/VIB. LAB./2476/95 dated May 05, 1995. Parkinson, A.G., McGuire, P.M., 1995. Rotordynamics Standards: New Developments and the Need for Involvement. Proceedings of the Institute of Mechanical Engineers Part C Journal of Mechanical Engineering Science 209(C5), 315-322. Rao, A. R., Sinha, Jyoti K., Moorthy, R. I. K., 1991. Vibration Diagnosis of Moderator Pumps of NAPP-2. BARC Report. Rao, A. R., Sinha, Jyoti K., Moorthy, R. I. K., 1991. Diagnosis of Turbo Dryer Vibrations. BARC Report Ref. No. RED/RIK/1793/91 dated June 12, 1991. Rao, A. R., Sinha, Jyoti K., Moorthy, R. I. K., 1997. Vibration Problems in Vertical Pumps Need for Integrated Approach in Design and Testing. Shock Vibration Digest 29, 8-15. Rao, V.B., 1999. Kurtosis as a Metric in the Assessment of Gear Damage. Shock and Vibration Digest 31(6), 443-448. Rao, J.S., 2000. Vibration Condition Monitoring of Machines. India: CRC Press. Sinha, Jyoti K., 2002. Health Monitoring Techniques for Rotating Machine. Ph.D. Thesis. University of Wales Swansea, Swansea, UK. Sinha, Jyoti K., Sinha, S. K. Sinha, Moorthy, R.I.K., 1993. Vibration Diagnosis of 25 VMR Pilger Mill of NFC, Hyderabad. BARC report ref.-rddg/rik/293/1993 dated 4 th February 1993. Sinha, Jyoti K., Sinha, S.K., Moorthy, R.I.K., 1996. Diagnosis of the Bearing Failure in a Pilger Mill. Shock and Vibration Digest 28(2), 11-14. Suryam, B.C.B.N., Sinha, Jyoti K., Rao, A.R., 2003. Dynamic Analysis on 2MW Inpile Loop Main Loop Pump. BARC Report.