INSTALLATION & OPERATION MANUAL

Similar documents
POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

Troubleshooting Salt Generators

Heat Pump. Quick Start Guide Models: 035, 055, 075, 090, 115, 110, 120, 121, 135, 155, 156, & 175

SALTWATER CHLORINATOR OWNERS HANDBOOK

FAQ s & Product & Troubleshooting Guide 37

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Pro Logic Version Diagnostics Manual

Zodiac LM3 Salt Water Chlorinator Owners Manual

GeyserWise TSE. thermostat instruction manual. SANS 181 compliant

Aqua Rite & Aqua Rite XL Diagnostics Manual

INSTANT HOT WATER RECIRCULATING SYSTEM

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Overheating limit control

CPSC/CPA SERIES Salt Water Chlorine Generator By Compu Pool Products

SWIMMING POOL HEAT PUMP Owners Manual

Eco-Chlor EC CHLORINATOR

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Water Priming Mode Purge air from plumbing system. How do I solve ER-3 WATER PRIME: TIPS ON FILLING SPA IMPORTANT NOTE WARNING

Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS

Disposal of the appliance Environmental protection:

Powerware 5110 UPS User s manual

INTRODUCTION WARNING S!!! VOC SHOULD BE BETWEEN MUST NOT EXCEED 96 VOC USE DC CIRCUIT BREAKER/ISOLATOR BETWEEN SOLAR PANELS & CONTROLLER

How To Use A Power Supply Unit (Upu)

Users Instructions BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

INFRARED QUARTZ WALL HEATER

manual owners Poolrite Equipment Pty. Ltd. SURECHLOR 4000 Pool Management System Warranty Card

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

DX Series Heat Pump Genus Compliant

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Disposing of the product - Protection of the environment:

User Manual HomeGrid 3000 Solar Generator

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Installation and Operation Back-UPS 1250, 1300, 1500

SAVE THIS MANUAL FOR FUTURE REFERENCE

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

3 IN 1 BATHROOM HEATER

100 Series Maxi Internal Filters. Instruction Manual

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Operating instructions

12 Volt 30 Amp Digital Solar Charge Controller

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

HEAT PUMP FOR SWIMMING POOL Installation and Instruction Manual

TT TOYS TOYS - OWNER S MANUAL. We are delighted that you have decided to purchase this TT Toys Toys children s car.

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

Stenner Pump Chlorinator Installation & Start Up Guide

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

, User s Manual

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

HX Series Pool & Spa Heater

Design Utility Lever Thermostatic Bath Shower Mixer

User s Manual Before using the inverter, you need to read and save the safety instructions.

INSTALLATION INSTRUCTIONS & OWNERS GUIDE

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

User Manual THR840DUK Digital Thermostat

WATER & POOL&FLOOR HEATERS OWNER S MANUAL. Including Installation Instructions and Warranty Information

WE-350 Series ¼ Turn Electric Actuator

EKOS Cart. Instructions for Use

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Dealer Sales & Service Guide

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

AUTODIALLER / QUICKDIALLER - SA132

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

SSNICLRG SSNICSM PLNICLRG PLNICSM

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Troubleshoot resources for homeowner

User s Manual AURORA 1.2K/2.2K

GL-235 Solar Pool Controller

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

Digital Fingerprint safe

12-Volt 10-Amp Regulated Power Supply

Portable Air Conditioner

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Owners Guide and Installation Instructions

Accessory Manual Ventilation Section Model Comfort Circle

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

ClearView 100. Instruction Manual

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

LK Electric Boiler - 4,5

Transcription:

INSTALLATION & OPERATION MANUAL Auto Cell Cleaning Model With Timer: A15TS - A20TS - A25TS - A30TS - A35TS No Timer: A15 - A20 - A25 - A30 - A35 27/30 Mudgeeraba Road, Worongary Queensland 4213 Phone 61 7 5565 0000 Fax 61 7 5565 0010 E. sales@evolutionwls.com.au www.evolutionwls.com.au

EVOLUTION SALTWATER CHLORINATOR Foreword Congratulations on purchasing an Evolution Series Saltwater Chlorinator for your swimming pool. This system is designed for robust reliability and easy operation to give you many years of trouble free service. Please read the instructions thoroughly before operating your unit. If you have any concerns or require any further assistance, then please to not hesitate to contact our friendly staff or any of our Evolution distributors. Chemicals It is important to note that the Evolution Series chlorinator does not maintain the water chemistry of your swimming pool water; it simply produces chlorine from a mild salt solution. To ensure that your chemical balances are within the guidelines listed below you should also have your water tested regularly at your local pool shop to encourage a sparkling clean healthy pool. PH Total Alkalinity Cyanuric Acid Salt Chlorine 7.2 7.4 90ppm 150ppm 40ppm 65ppm 4000ppm 1.5ppm 2.0ppm For the best chlorine results in a balanced pool a salt level of 4000 parts per million (ppm) is required. This is easily achieved by using the formula below or approximately 20kg of salt per every 5000 litres. For example: Pool volume = Length x Width x Average Depth x 1000 = 9m x 4m x 1.5m x 1000 = 54000 litres Salt required = Pool Volume x 4 (salt level required, 4000ppm) 1000 = 54000 x 4 1000 = 216kg Or 11 x 20kg bags of pool salt NB: Before adding salt to your swimming pool, please make sure your Evolution Series Chlorinator is switched off to avoid overload damage. THIS WILL VOID ALL WARRANTY. It is recommended to manually add chlorine to your swimming pool on initial startup as a saltwater chlorinator is designed to maintain Chlorine levels and not run for unnecessary long hours to try to build an acceptable chlorine level. The manual addition of chlorine may also be required for unforeseen situations where your swimming pool has required a high chlorine demand, for example after large bather load. 1

Cell Housing Installation The electrolytic cell housing must be plumbed into the return line after the filter. Please see the installation diagram, fig.1, below for the preferred method. If a heater is plumbed into the system then the cell housing must be installed after the heater in the return line to protect the elements or heat exchanger. If a solar heating system is installed then the cell housing should be fitted after the line going up to the roof and after the return line coming back from the roof if it rejoins the main swimming pool return. The cell housing has allocations for either 40mm PVC pipe or 50mm PVC pipe with the use of the supplied PVC reducing bushes. 2

Power Pack Installation Mounting the Evolution chlorinator power pack is done by either using the supplied mounting bracket or directly hanging on the wall with screws. If mounting directly on the wall, use the guide notches on the top vents to position the holes for installation. The chlorinator power pack is to be mounted at least 800mm above ground level. It is strongly recommended that the unit be installed where it is protected from the elements. Rain and sunlight will prematurely age your unit. It should also be mounted in a position where it is away from accidental water spray. The unit should be installed so that adequate air flow can circulate freely around the power pack to allow the chimney drafting effect to perform efficiently. Functions Now that you have installed your Evolution power pack and cell correctly you can learn how to use it. All Evolution Series chlorinators are fitted with a 240v 10A power socket located on the right hand underside of the power pack. Your pool pump should be plugged into this socket so that the chlorinator and pump activate together when the timer switches on at the allocated time settings or in a model without a timer the pump and chlorinator is controlled by the on/off switch. 7 in fig 2..Failure to plug the pool pump into this socket could lead to the chlorinator staying on with no water circulation. In case of water probe failure, over heating and a possible gas build up may occur. This build up may shatter the cell housing. Please see fig.2 below in regards to function control. Fig 2. 3

1. Chlorine Output LEDs Fig.2 The output lights follow the curve of the distinguished Evolution logo. If the correct salt level is in the pool then all 10 lights will illuminate. Each light represents 10% chlorine output. If all lights are not illuminated then a higher salinity level will be required. Make sure all salt is dissolved properly before adding more. The chlorine control, 2 in fig. 2, will increase or decrease the chlorine output to suit your chlorine demand. If all of the indicator lights flash then there is a water fault problem. 2. Chlorine Control Fig. 2 The chlorine controller determines the amount of chlorine production. By simply turning the control clockwise you increase the chlorine output and by turning the control anti-clockwise you decrease the chlorine output. Do not force the control past its stop as this will damage the unit and void warranty. 3. High Salt Light Fig 2 This light is a red warning indicator and will only illuminate when the salt level in the swimming pool is higher than 4500 parts per million. If this light is on, decrease the output by turning the chlorine control, 2 in fig.2., anticlockwise until the high salt (red light) goes off and the 10 chlorine output LEDs are on. 1 in fig 2. If this light is the only one illuminated then the unit has gone into over temperature cutout and will reset once back to normal running temperature. 4. Polarity Light Fig 2 The polarity light is the first indicator light, 10% in the chlorine output array, 4 in fig.2. This light will alternate between orange and green every reversing cycle, 4-12 hours. Factory setting is a 12 hour cycle. 5. Timer Fig 2 The FM/1 series time switch is designed for control of the chlorinator and circulation pump 24 hours. Time Setting To set the time, turn the minute hand clockwise. Do not set the time by rotating the outer dial. Turn the minute hand clockwise until the time of day on the outer dial is aligned with the red marker on the inner dial (nine o clock position). For example, to set the chlorinator and pool pump for 3.00pm, adjust the timer as per Fig 3. The inner dial on the timer has 24 hr markings with 15 minute increments. Turn the minute hand clockwise until 15, 3.00pm, is aligned with the red mark on the inner dial. The hour and the minute dial will show exactly 3.00pm. It is very important to make sure that if you set the time to 3.00pm then the red mark on the inner dial must point to 15 not 3, which would be 3.00am. The time switch is programmed by pushing the captive trippers to the outer ring position for the entire period that the chlorinator and pump is to be turned ON, i.e. each tripper is worth 15 minutes on the 24 hour dial. When the tripper is pushed in, the timer is in the OFF position. Manual Switch Minute Hand Inner Dial 3.00pm must match the red mark on the inner dial (15.00) Comes on at 3.00pm (15.00) and turns off at 7.00pm (19.00) Fig 3 Outer Ring One Tripper is 15 Minutes 4

6. Circuit Breaker The circuit breaker mounted on the front right hand side of the Evolution chlorinator is designed to trip out in the event of power surge or overload. When tripped the yellow centre button will pop out shutting down the unit. To reset, press the yellow centre button back into resume normal function. Important note, turn off the chlorinator at the power point before attempting to reset the circuit breaker. Should the circuit breaker continue to trip then you should contact your local Evolution distributor. 7. Switch Timer Model (A_TS): This switch allows you to choose the timer operation mode for your chlorinator and pool pump. Switched to the left position, Timer, allows the chlorinator and pool pump to turn off and on at your designated timer settings. The Manual selection, switched to the right, allows the chlorinator and pump to work continuously until you physically change the chlorinator s mode. The Off position in the middle will turn the power off to the chlorinator and circulation pump. No Timer Model (A_): This switch allows you to turn the chlorinator and pump ON and OFF only. Maintenance Some of the components have already been discussed in this manual in regards to keeping a happy sparkling clean pool but here is a quick summary. Correct pool water chemistry is a must so take your water sample to your local pool shop and have it tested regularly. Even though you have purchased a self cleaning chlorinator, maintenance on the cell is imperative to promote optimum chlorine production and cell life. Where the chlorinator is producing Chlorine, a small amount of Calcium builds up on the cell plates. After 12 working hours Calcium may stay attached to the edges of the plates or the water probe hence requiring cleaning. There are too many variables to determine the regularity of cleaning the cell but it should be cleaned in a mild Hydrochloric Acid solution,1 part acid to 10 parts water, at least every six months. When cleaning the cell you must turn the chlorinator off or it will damage your unit and void warranty. Do not use any utensils or harsh chemical cleaners to remove any calcium buildup from the cell as it will damage the cell s semi precious coating and again void warranty. The chlorinator power pack should only be serviced by qualified electrical technicians. For your nearest Evolution recommended service technician, please contact Evolution Water & Lighting Solutions on +61 5565 0000 or email us on repairs@evolutionwls.com.au. 5

TROUBLESHOOTING Fault/Problem Possible Cause Remedy NO FLOW - All chlorine output LED s flashing as per note 1. Page 4 HIGH SALT - Red LED illuminated 3. Page 3 Pump turned off Valves closed Air in system Dirty filter/blockage Low water level Calcium buildup on water probe Sensor Salt too high, above 4500ppm Ensure pump is on Valves open Check all o-rings and grease Clean or Backwash filter Fill up pool Clean probe in a mild hydrochloric acid Page 5 Turn chlorine control anticlockwise as per note 3. Page 4 until salt levels reduce NO LIGHTS Circuit Breaker tripped, 6. Page 3 Reset Circuit Breaker as per note 6. Page 5. If it trips again immediately call a technician. LOW / NO CHLORINE PRODUCTION ABNORMAL CALCIUM BUILDUP ON CELL TIMER TIMES OUT OF SYNC OVER TEMPERATURE - Red LED Illuminated Only (no other lights) 3. Page 3 Mains power failure Chlorine output too low Salt level too low PH too high Timer period too short High phosphate levels Cell connections Calcium levels in swimming pool water are extremely high or water chemistry is not balanced Timer not set correctly Chlorinator installed on off peak tariff Timer / Off / Manual switch not switched correctly Salt Level too high, above 4500ppm Installed in an area where the ambient temperature is extremely high Check switches and switchboard circuit breaker Increase chlorine production as per note 2. Page 4. Increase salt level to 4000ppm and check stabiliser (Cyanuric) levels Adjust Ph between 7.2 7.4 Increase running time Add Starver Check connections at junction box under unit. Get your water tested and balanced as per the Langlier Saturation Index Unit not reversing, call a technician. Check setting procedure as per note 5, Page 4 Timer will need battery backup if installed on off peak tariff Make sure switch is selected as per note 7, Page 5 Turn chlorine control anticlockwise as per note 3. Page 4 until salt levels reduce. Supply adequate cooling. Install outside of the extreme temperature. 6

Warranty Your Evolution Series Chlorinator is covered by a 3 year full warranty from the date of purchase. The power pack controller and electrolytic cell are covered against defects in materials and assembly from the date of purchase in a domestic application. All electrical or mechanical failure due to faulty components will be repaired or replaced at no cost to the owner, including labour. Warranty will not be given without proof of purchase, so keep your original purchase invoice in a safe place. In field labour is limited to the Gold Coast city metropolitan area. Outside of these areas the complete unit should be returned to Evolution Water & Lighting Solutions or one of our warranty agents. Freight charges may apply and are completely at the discretion of Evolution Water & Lighting Solutions. Please contact us in regards to a recognised warranty agent in your area. Unfavourable environments and operating conditions beyond the control of the manufacturer such as incorrect power supply (Must be 230V 50 Hz), the Evolution Series chlorinator plugged into an ancillary device such as a Variable Frequency Drive, wear and tear, water and insect damage, extreme ambient temperatures or any other adverse situation that affects the Evolution Series Chlorinator will void warranty. All warranties only apply if the equipment is installed and operated in complete compliance with the installation and operating instructions. Evolution Series Chlorinators and electrolytic cells installed in a commercial situation are covered by a 1 year warranty. Commercial situations meaning motels/hotels, health spas, apartment/town house complexes and any situation with an unusually high bather load or abnormal conditions. Evolution Water and Lighting Solutions will not accept liability for any consequential loss or damage of any kind. FOR ALL WARRANTY ENQUIRIES PLEASE DO NOT HESITATE TO CALL +61 7 5565 0000 OR EMAIL repairs@evolutionwls.com.au 7

NOTES 8

NOTES 9

27/30 Mudgeeraba Road, Worongary Queensland 4213 Phone 61 7 5565 0000 Fax 61 7 5565 0010 E. sales@evolutionwls.com.au www.evolutionwls.com.au 10