HVAC DEFAULT Macro (9902) Drive Only (NO Bypass)

Similar documents
ACH550 BCR/BDR/VCR/VDR E-Clipse Bypass Drives. User s Manual. ACH550 E-Clipse Bypass User s Manual 2-1

ABB HVAC Drives ACH400 Vertical Electronic Bypass to ACH550 E-Bypass, 208V, 480V (R1... R4 Frame Size Drives)

GPD 506/P5 Start-up Procedure and Checklist

NX Series Inverters. HVAC Pocket Programming Guide

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

ACH550-UH HVAC Drives. User s Manual. ACH550-UH User s Manual 1-1

ABB drives. User s manual ACS310 drives

Installation and Start-up Guide. RS485 and RS232 Adapter for product type ACS 140

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

Low voltage AC drives. ABB drives for HVAC Committed to your comfort zone

ACS800. Firmware Manual ACS800 Standard Control Program 7.x

VLT 6000 HVAC. Contents

Configure Inverter output for two utility settings, (1)120V/60Hz, (2)220V/50Hz

32VFD Variable Frequency Drives for Centrifugal Chillers

A1000 Cheat Sheet (Open Loop Vector)

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

Electronic Control Devices The European Product Catalogue 2007

INSTALLATION INSTRUCTIONS

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

ABB general machinery drives. User s manual ACS355 drives

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

OPL BASIC. Dosing System for Professional Laundry machines. Contents

PART 11: START-UP PROCEDURES FOR THE INSTALLER

ACS800. Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program

Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

ABB machinery drives. User s manual ACS355 drives

Automatic Voltage Regulator User s Manual

ACS800. Firmware Manual ACS800 Standard Control Program 7.x

PRODUCT PROFILE FEATURES

NXL Series Inverters. HVAC Inverters made simple

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

WinLIN Setup and Operation:

ABB drives. User s manual ACS150 drives ( kw, hp)

ACS800. Firmware Manual ACS800 Pump Control Application Program 7.2 (+N687)

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

ABB Drives. User s Manual HTL Encoder Interface FEN-31

RLC Series Resonance

Specifying a Variable Frequency Drive s

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Operational Overview and Controls Guide

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Installation and Operation Guide for PD4000 Series Power Control Center

SX460. Generator Automatic Voltage Regulator Operation Manual

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Surface Technology. Centrifugal Fan GMD

Softstarters. Type PST/PSTB Fieldbus communication CANopen for PST sw CU SFC132070M0201 February SFC132070M0201 1

Electronic, Digital and Mechanical Vibration Switches

Product Bulletin. ABB drives for HVAC applications ACH550, 1 to 550 Hp

Oil and Coolant Circulating Heating System. Model - OCSM

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

Installation and Operation Guide for PD4100 Series Power Control Centers

TAKEDO -3VF V20 INSTRUCTION MANUAL REL. DATE T.M. Check and Approval

HERZ-Thermal Actuators

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

SPEEDMASTER MICRO SERIES COMPACT INVERTERS

*.ppt 11/2/ :48 PM 1

Number 1 in efficiency

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

GAS DETECTOR CONTROL PANEL (TWENTY CHANNEL)

POINTS POSITION INDICATOR PPI4

ABB general purpose drives. Firmware manual ACS580 standard control program

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

SMC FLEX QUICK START BULLETIN 150

Operating and installation instructions. Professional plasma torch height control. Model: MyPlasm THC

Features, Benefits, and Operation

Allen-Bradley/Rockwell

Installation manual. Generator Paralleling Controller GPC multi-line C

Via dell' Industria, S. Vendemiano (TV) Tel Fax Acquisti@elettrolab.

Pumping Technology OMEGA ECOFLEXX GLANDED PUMPS INSTALLATION AND OPERATION MANUAL

Installation and Maintenance manual. Softstarters PST / PSTB

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Instruction Manual for Operating Panel 301 and 302

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide

PUMP DRIVES ENTRAÎNEMENTS DE POMPES PUMPENANTRIEBE MOTOR DE BOMBAS UNITÀ DI CONTROLLO POMPA OPERATING MANUAL: MODE D EMPLOI:

Buck - Boost Transformers

Designed for multi-injector endurance testing, the

FAQ s on Siemens Magmeters

Installation, Operation and Maintenance Manual

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

omega.com ΩOMEGA RS232 Multi-Drop FMA1600-MDB Multi-Drop Box

Installation Manual Version 7.3 IMPORTANT:

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

PDS-375-TR Touring CB Power/Data Supply Operator s Manual Rev 1.2

PARAGON ELECTRIC, INC. LIQUID LEVEL CONTROLLER USER MANUAL MODELS: LLC-I, LLC-II AND TELEMETRY OPTIONS

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

GE Industrial Solutions ASTAT BP. User Manual

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

REGAL-BELOIT. Installation and Operation Manual. Variable Speed AC Motor Drives. Micro and PowerWash Series

GSM-DL2 GSM auto dialer

computer (please download the software from the official website if there is no CD available).

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

SYSTEM 45. C R H Electronics Design

Transcription:

Mech-Line ABB ACH550 Simplified Startup X Check For and Correct as Necessary Before Powering Drive The drive is securely mounted Space above and below drive meets specifications for cooling (8 in. R1-R6 sizes 6 in. R7-R8 sizes) Motor and driven equipment are ready to start (ie. No mechanical obstructions) Proper grounding (Follow national and local codes) Input power voltage matches drive rating (Label is located on left side of unit) Input power connections are connected and are tight Input power branch circuit protection is in place (ie. Fuses or circuit breaker) Motor connections are connected and are tight Input power, motor and controls are each in separate conduit runs (Recommended) NO foreign objects, shavings or tools are left in the drive NO alternate power source for the motor (such as a bypass connection) is connected to the motor or is connected to the drive output section (ie. NO voltage is applied to the drive output!!!) HVAC DEFAULT Macro (9902) Drive Only (NO Bypass) Jumpers Connected to Drive Control Board Connect #10 24V to #16 DI4 Connect #11 GND to #12 DCOM 10 24V 11 GND 12 DCOM 13 DI1 14 DI2 15 DI3 16 DI4 17 DI5 18 DI6 2 AI1 + 3 AI1 -

E CLIPSE BYPASS Macro (9902) Drive WITH Bypass Jumpers Connected to RBCU-01 Bypass Control Board JUMPERS ARE IN PLACE THERE IS NO NEED TO ADD ADDITIONAL JUMPERS AT THIS TIME 1 +24VDC 2 +24VDC 3 DIGITAL INPUT COMMON 4 GROUND 5 DI1 START/STOP 6 DI2 NOT USED 7 DI3 START ENABLE 1 8 DI4 NOT USED 9 DI5 NOT USED 10 DI6 SMOKE CONTROL The information below shows the welcome message that may be on the display screen when the drive is initially powered up and how to remove it from the screen permanently. Initial Startup for ACH550 with or without bypass Initial screen is Welcome to the ABB ACH550 Drive Screen is Do you want to use the Start-up Assistant Screen is Show Start-up Assistant on Next Boot Press OK (Right Soft Key) Press to Highlight NO Press OK (Right Soft Key) Press to Highlight NO Press OK (Right Soft

Basic Programming This is to access programming. Right Soft Key will access all parameters and will make all changes. The key function however will change from screen to screen. Follow the steps listed below to make changes. They are as follows: MENU will be above right soft key (Note: all parameter changes will be made and/or entered using this key) EXIT will be above left soft key Press MENU (Right Soft Key) Look for PARAMETERS Press ENTER (Right Soft Key) Look for the Parameter Group Number you wish to see by using or arrows Press SEL (Right Soft Key) Look for the Parameter you wish to change by using the or arrows Press EDIT (Right Soft Key) The parameter will now take up the entire screen Change the Parameter by using or arrows Press SAVE (Right Soft Key) to accept the change that has been made Press EXIT (Left Soft Key) to go back to the Parameter(s) list to choose a new Parameter to change Repeat above procedures to continue to make changes as necessary Press EXIT (Left Soft Key) repeatedly to return to main screen once all changes have been made and you wish to run the drive Basic Parameter Settings (Does NOT Include All Parameters) The only parameters that will be listed below will be those that would be changed.

When using the default Macros such as HVAC Default or E- Bypass the Start/Stop and Safeties will be preset and should not need to be changed provided the proper digital closures are to be used for these. When using the default Macros such as HVAC Default or E-Bypass the External Reference will be preset and should not need to be changed provided a voltage of 0-10 VDC or 4-20mA is to be used and is connected to AI1. Parameter Value 9901 Language English (AM) 9902 Applic Macro HVAC Default (Drive Only..Verify) E-Clipse (With Bypass..Verify) 9906 Motor Nom Curr Set as required 9908 Motor NOM Speed Set as required 9909 Motor Nom Power Set as required 1301 Minimum AI1 20% (To be used for 4-20mA) 0% (To be used for 0-10VDC) 2003 Max Current Set as required 2007 Minimum Freq 15 Hz (To be used for fans) 20 Hz (To be used for pumps and cooling towers using gearbox design fan) 2605 U/F Ratio Linear 3002 Panel Comm Err Last Speed 3005 Motor Therm Prot Not Sel 3104 AR Overcurrent Enable This simplified start-up allows you to set the drive to run the process. If attempts by unauthorized personnel extend beyond these items, the result could be added time to the ABB Certified Startup if so requested and could result in added charges for additional time.

Motor Rotation Changes With a Drive and Bypass Bypass Unit will display a Failt 3020 PHASE SEQUENCE Fault if input rotation is incorrect. The input phase wires would need to be swapped in order to correct this. Rotation should then be checked or rechecked. If the motor rotates correctly there will be no other changes needed. If the motor rotates in the wrong direction then the motor output wires would need to be swapped.