Digital flow ELEMENT transmitter for continuous flow measurement

Similar documents
How To Use A Flowmeter

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Digital inductive conductivity transmitter

Cable Plug acc. to DIN EN , Form A

Electric Rotary Actuator - On/Off or programmable control actuator

Control- and feedback head for integrated mounting on Robolux valves Type 2036

4/2-Way Pneumatic Solenoid Valve

3/2-way Solenoid Valve, direct-acting, NC or NO

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

3/2-way pneumatic cartridge solenoid valve

Inductive sensor NI10-M18-Y1X-H1141

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

Turbine Flow Sensor Series VTR

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Assisted lift operated 2/2-way solenoid valves Type EV250B

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Color Mark Sensor with Red or Green LED E3S-VS

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Proportional pressure regulators VPPE

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

4 Posiflow Proportional Solenoid Valves

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Combi switchbox with integrated 3/2 way pilot valve

Plastic tube flowmeters Series PT/PS

Digital display DA 48

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

BOS 73K... BOS 74K...

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Digital input modules

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Magnetic proximity switches

Duct Humidity Transmitter

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Pressure transmitter For general industrial applications Model A-10

SITRANS F flowmeters SITRANS F M

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

System 8. ü ( System 8

ELECTROMAGNETIC FLOWMETER COMPACT

How To Use A Corona Mdi 110

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Cross-beam scanning system to detect slim objects. 100 mm in

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Liquid Level Limit Switch liquiphant T FTL 20

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

IFC 070 Technical Datasheet

Electronic Pressure Switch EDS 300

Solenoid valves 2/2-way direct-operated Type EV210A

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

SELECTION, APPLICATION AND MAINTENANCE

Type 3353 Angle Seat Valve

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

2.24. Pump Controller 704. Data Sheet

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Safety at a high level!

! WARNING. Before using product, read and understand instructions.

Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for Gases

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

3/2-way Mini Solenoid Valve

VAD. Variable Area Desuperheaters

Typical Aluminum GFM Mass Flow Meter

Conductive Level Switch FK 2 Technical Data:

Technical Information RIA14

VAD Variable Area Desuperheaters

2/2 and 3/2 Way Size 6 Seat Valves

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Series DFMT Digital Paddlewheel Flowmeter

Instruction Manual. T3111 T3111L T3111P T3111Ex

PIEZOMETER AIRFLOW MEASURING RING

Capacitive Prox E2K-X

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

HF series Hall effect joysticks

Operating Instructions for Plastic Flow Meter. Model: KSK

PRODUCT PROFILE FEATURES

T U R B I N E G A S M E T E R

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Solenoid Valve Island Type 3965

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

HERZ-Thermal Actuators

Hose and Tube Fittings Series 1-3

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Single sub-base valve

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

Transcription:

Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single or dual 4-20 ma current output(s) Removable backlit display of flow and/or two totalized volumes Automatic-calibration: TEACH-IN, simulation of outputs signals provided without the need for real flow Type S030 INLINE fitting Type 2101 (8692) Continuous TopControl system Type 6213 Solenoid valve Type 2030 On/Off Diaphragm valve Type 8644 Valve islands Type 8611 econtrol universal controller The Bürkert transmitter Type 8036 is a compact device, specially designed for measuring the flow rate in solid-free liquids, in a variety of applications (water, waste water monitoring, chemical processing...). The transmitter is made up of a compact INLINE fitting equipped of a sensor with paddle-wheel and an enclosure with cover, containing the electronic module. A removable display completes this transmitter. This ensemble (SE36) is quickly and easily connected to the fitting (S030) by a Quarter-Turn. The flow transmitter can operate without the display, but it will be required for programming the transmitter (i.e. set parameters, restore default parameters, programme information to be displayed, programme access codes, adjust 4-20 ma output(s)...) and also for visualizing continuously the measured and processed data. The device Type 8036 is available with: - 2 programmable outputs : one transistor output (NPN) and one 4-20 ma current output (2-wire) - 3 programmable outputs : two transistor outputs (NPN/PNP) and one 4-20 ma current output (2-wire) - 4 programmable outputs: two transistor outputs (NPN/PNP) and two 4-20 ma current outputs (3-wire) General data Compatibility Materials Housing cover Gaskets Screws Fixed connector mounting plate Fixed connector Display Navigation key Quarter-Turn system Display (accessories) Electrical connections 2 or 3 outputs transmitter 4 outputs transmitters Connection cable Environment Ambient temperature Relative humidity Any pipe from DN 06 to 65 which are fitted out with Bürkert INLINE Fitting S030 (see corresponding data sheet) See exploded view, on next page Stainless steel 1.4561, PPS EPDM Stainless steel Stainless steel 1.4404 (316L) Brass nickel plated PBT Grey dot matrix 128 x 64 with backlighting 1 x 5-pin M12 male fixed connector, 1 x 5-pin M12 male and 1 x 5-pin M12 female fixed connectors Shielded cable -10 up to +60 C (32 to 140 F) (operating and storage) 85%, without condensation The device Type 8036 converts the measured signal, displays different values in different units (if display mounted) and computes the output signals, which are provided via one or two M12 fixed connectors. Thanks to 1 or 2 transistor outputs, the transmitter can be used to switch a solenoid valve, activate an alarm and, thanks to 1 or 2 current outputs, establish one or two control loops. www.burkert.com p. 1/7

Complete device data (Pipe + transmitter) Pipe diameter DN 06 to 65 Measuring range 0.3 up to 10 m/s Medium temperature with fitting in PVC PP PVDF, brass or stainless steel Medium pressure max. Viscosity / Particles rate Measurement error Teach-In Standard K-factor Linearity ±0.5% of F.S.* 1) Repeatability ±0.4% of Reading 1) 0 up to 50 C (32 to 122 F) 0 up to 80 C (32 to 176 F) -15 up to 100 C (5 to 212 F) PN10 (145 PSI) (with plastic fitting) - PN16 (232 PSI) (with metal fitting) - (PN40 on request, see S030 data sheet) - see pressure / temperature chart 300 cst max. / 1% max. ±1% of Reading (at Teach-In flow rate value) 1) ±2.5% of Reading 1) 1) Under reference conditions i.e. measuring fluid=water, ambient and water temperature=20 C (68 F), applying the minimum inlet and outlet pipe straights, matched inside pipe dimensions. * F.S.=Full scale (10 m/s) Electrical data Power supply 2 or 3 outputs transmitter (2-wire) 4 outputs transmitter (3-wire) Characteristics of the power source (not provided) of UL recognized devices Current consumption with sensor 2 or 3 outputs transmitter (2-wire) 4 outputs transmitter (3-wire) Power consumption Reversed polarity of DC Voltage peak Short circuit Output Transistor 1 Transistor output (Transmitter 2-wire) 14-36 V DC, filtered and regulated 12-36 V DC, filtered and regulated Limited power source (according to 9.3 of the UL61010-1 standard) or, Class 2 type power source (according to the 1310/1585 and 60950-1 standards) 1 A (with transistors load) 25 ma (at 14 V DC without transistors load, with current loop) 5 ma (at 12 V DC without transistors load, without current loop) 40 W max. Protected Protected Protected for transistor outputs NPN, open collector, 1-36 V DC, max. 700 ma Pressure / temperature chart A : application range for complete device (Fitting + transmitter) Materials view Brass, nickel plated EPDM PPS 2 Transistor outputs (Transmitter 2 or 3-wire) Current 1 Current output (Transmitter 2-wire) Configurable as sourcing or sinking (respectively both as PNP or NPN ), open collector, max. 700 ma, 500 ma max. per transistor if the 2 transistor outputs are wired NPN-output: 1-36 V DC PNP-output: Power supply 4-20 ma programmable as sourcing or sinking (in the same mode as transistors), max. loop impedance: 1100 at 36 V DC ; 610 at 24 V DC; 180 at 14 V DC Stainless steel EPDM 2 Current outputs max. loop impedance: 1100 at 36 V DC; (Transmitter 3-wire) 610 at 24 V DC; 100 at 12 V DC 4... 20 ma measurment error ±1% Standards, directives and approvals Protection class IP65, IP67, NEMA 4X and NEMA 6P with M12 cable plug mounted and tightened and cover fully screwed down Standard and directives EMC Pressure Vibration / Shock Approvals UL-Recognized for US and Canada EN 61000-6-2 (2005), EN 61000-6-3 (2001) Complying with article 3 of 3 from 97/23/CE. directive* EN 60068-2-6 / EN 60068-2-27 UL61010-1 + CAN/CSA-C22 No.61010-1 * For the 97/23/CE pressure directive, the device can only be used under following conditions (depend on max. pressure, pipe diameter and fluid). Type of fluid Fluid group 1, 1.3.a Fluid group 2, 1.3.a Fluid group 1, 1.3.a Fluid group 2, 1.3.a Conditions DN 25 only DN 32 DN > 32 and PN*DN 1000 PN*DN 2000 DN 200 p. 2/7

Principle of operation Bürkert designed fitting (S030) ensures simple installation of the electronic housing of the 8036 into pipes from DN 06 to DN 65. The sensor with integrated paddle-wheel is mounted in the fitting. When liquid flows through the pipe, the paddle-wheel with 4 inserted magnets is set in rotation, producing a measuring signal in the sensor (Hall sensor). The frequency modulated induced voltage is proportional to the flow velocity of the fluid. A conversion coefficient (K-factor, available in the instruction manual of the S030 fitting), specific to each pipe (size and material) enables the conversion of this frequency into volume. The electronic component converts the measured signal into several outputs (according to the transmitter version) and displays the actual value. Counters are used to obtain the volume of fluid passed through the pipe. In-line installation The electronic SE36 can easily be installed into any Bürkert INLINE fitting system (S030), by means of a Quarter-Turn. Minimum straight upstream and downstream distances must be observed. According to the pipe's design, necessary distances can be bigger or use a flow conditioner to obtain the best accuracy. Fore more information, please refer to EN ISO 5167-1. EN ISO 5167-1 prescribes the straight inlet and outlet distances that must be complied with when installing fittings in pipe lines in order to achieve calm flow conditions. The most important layouts that could lead to turbulence in the flow are shown below, together with the associated prescribed minimum inlet and outlet distances. These ensure calm, problem-free measurement conditions at the measurement point. DN = orifice Fluid direction --> Regulating valve 2 x 90 elbow joint Extension 2 x 90 elbow joint 3 dimensional 90 elbow joint or T-piece Reduction The flow rate sensor can be installed into either horizontal or vertical pipes. Pressure and temperature ratings must be respected according to the selected fitting material. The suitable pipe size is selected using the diagram Flow / Velocity / DN. The flow transmitter is not designed for gas flow measurement. p. 3/7

Selection of fitting / pipe size Example: - Specification of nominal flow: 10 m 3 /h - Ideal flow velocity: 2...3 m/s For these specifications, the diagram indicates a pipe size of DN40 [or DN50 for (*) mentioned fittings] Flow rate Not recommended * For following fittings: - with external threads acc. to SMS 1145 Flow velocity - with weld-ends acc. to SMS 3008, BS 4825 / ASME BPE or DIN 11850 Series 2 - with Clamp acc. to SMS 3017 / ISO 2852, BS 4825 / ASME BPE or DIN 32676 Dimensions [mm] of transmitter Type 8036 DN H with S030 fitting 06 160 08 160 15 165 20 163 25 163 32 166 40 170 50 177 65 177 p. 4/7

Ordering information for compact transmitter Type 8036 A complete flow transmitter Type 8036 consists of a compact flow ELEMENT transmitter Type SE36, a removable display/programmer and a Bürkert INLINE fitting Type S030 The following information is necessary for the selection of a complete device: Item no. of the desired compact flow transmitter Type SE36 (see ordering chart on p. 6) Item no. of the selected INLINE fitting Type S030 (see separate data sheet) You have always to order separately two components. Attention! When you order devices without display, please take care that you also order at least one display module for the operation. Order no. of the removable display / programming module (see ordering chart on p. 6) When you click on the orange box "More info." below, you will come to our website for the resp. product where you can download the data sheet. Example Compact transmitter without display Type SE36 Complete flow transmitter Type 8036 Compact transmitter without display Type SE36 Removable display/programmer + INLINE fitting Type S030 p. 5/7

Ordering chart for compact transmitter Type SE36 Specifications Voltage supply Output Electrical connection UL Approval without display Item no. with display 2 outputs 14-36 V DC 1 x transistor NPN + 1 x 4-20 ma (2-wire) 5-pin M12 male fixed connector No 560 880 561 880 560 883 561 883 Recognized 3 outputs 14-36 V DC 4 outputs 12-36 V DC 2 x transistors NPN/PNP + 1 x 4-20 ma (2-wire) 2 x transistors NPN/PNP + 2 x 4-20 ma (3-wire) 5-pin M12 male fixed connector 5-pin M12 male and 5-pin M12 female fixed connectors No 560 881 561 881 560 884 561 884 Recognized No 560 882 561 882 560 885 561 885 Recognized Note: Order separately (see accessories) - M12 cable plugs (only female for single 4-20 ma, 1 male + 1 female for dual 4-20 ma transmitter) Ordering chart for accessories Description Item no. Removable display/programmer module (with instruction sheet) 559 168 Black blank cover with seal 560 948 Transparent cover with EPDM seal 561 843 5 pin M12 female straight cable plug with plastic threaded locking ring, to be wired 917 116 5 pin M12 male straight cable plug with plastic threaded locking ring, to be wired 560 946 5 pin M12 female straight cable plug moulded on cable (2 m, shielded) 438 680 5 pin M12 male straight cable plug moulded on cable (2 m, shielded) 559 177 p. 6/7

Interconnection possibilities with other Bürkert devices Type 8611 - Single channel controller Type 2101 - Process Valve with positioner Type 6642 - Solenoid valve PLC Type SE36 - Compact flow transmitter Type S030 - INLINE fitting To find the nearest Bürkert, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. Subject to alteration Christian Bürkert GmbH & Co. KG 1401/4_EU-en_00895130 p. 7/7