9000 Series Accelerometers Specifications

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

PROXPAC XL Proximity Transducer Assembly

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

Proximity Transmitters and Seismic Vibration Transmitters

3500/62 Process Variable Monitor

3300 XL 8mm Proximity Transducer System Bently Nevada* Asset Condition Monitoring

How To Power A Schen

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

3500/22M Transient Data Interface

Description. Specifications and Ordering Information 3300 Proximity Transducer System Patents: 5,016,343; 5,126,664; 5,351,388; and 5,685,884

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Givare NC-SRS 280 och 880

3300 XL NSv* Proximity Transducer System Bently Nevada* Asset Condition Monitoring

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

2100 Eddy Current Probe Systems Specifications

1900/65A General Purpose Equipment Monitor

SEISMIC VELOCITY TRANSDUCER T1-40

Differential-Hall-Effect based Sensors Series A5S Overview

QR12 (1.22 ) Diameter Optical Encoder

Current Probes. User Manual

1900/65A General Purpose Equipment Monitor

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

db MISER ULTRA LOW LOSS CABLE ASSEMBLIES Are you a design or test engineer fighting a challenging loss budget?

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Inductive sensor NI10-M18-Y1X-H1141

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

IMVIB. Online vibration monitoring for Ariel compressors

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Times Microwave Systems Hermetically Sealed Assemblies

Series 8146/5-V37 and Series 8150/5-V37

VIBRATION SWITCHES SOLID STATE

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Technical data sheet TDS0070

Technical Data. Dimensions

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Directory chapter 04

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

LIEBERT VNSA Installation Sheet

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Troubleshooting accelerometer installations

I-PEX MHF4 Micro Coaxial Connector

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

The Do s and Don ts of Pressure Transducers

DTS-HAZ DTS-HAZ-DC. Installation Instructions. for use with Self-Regulating, Constant Wattage & Mineral Insulated Electric Heating Cables

Toroidal Conductivity Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

How To Read A Pipe From A Sensor

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Linear Luminaire with LED Series EXLUX 6402/2

SMA Waterproof. Cable Assembly. Filtered Audio Connector. Dataport Receptacle. Dataport Plug

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Waterproof Connectors for Outdoor Use

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

8146/5 Series Breaker Panelboards

A99B Series Temperature Sensors

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

How To Use A Flowmeter

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.

Rosemount 751 Field Signal Indicator

Absolute Rotary Encoder E6CP

Industrial Ringdown/Autodialer Telephone SCR Series

1756 ControlLogix Chassis Specifications

Electronic Pressure Switch EDS 300

3DLevelScanner II TECHNICAL DATA SHEET

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Description. Dimensions. Features. precision works better

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Mounting instructions. Acceleration Transducer B12. B 26.B12.10 en

Capacitive Prox E2K-X

ABSOLUTE ROTARY ENCODER ETHERNET/IP

gesis IP + Heavy Duty Class I, Zone 2

MIL-STD-1553 Data Bus

Transcription:

330525 Velomitor* XA Piezo-velocity Sensor Bently Nevada* Asset Condition Monitoring Description The Velomitor* XA (extended Application) Sensor is a ruggedized version of Bently Nevada's 330500 Velomitor Sensor. Its 316L stainless steel case and unique, weatherproof connector and cable assembly permit mounting without a housing. The Velomitor XA Sensor cable assembly is suitable for use in moist environments, and the Velomitor XA Sensor design meets the requirements of IP-65 and NEMA 4X when properly installed with a mating extension cable. Caution If housing measurements are being made for overall protection, give thought to the usefulness of the measurement for each application. Most common machine malfunctions (imbalance, misalignment, etc.) originate at the rotor and cause an increase (or at least a change) in rotor vibration. For any housing measurement alone to be effective for overall machine protection, the system must faithfully transmit a significant amount of rotor vibration to the bearing housing or machine casing, or more specifically, to the mounting location of the transducer. In addition, exercise care when choosing the physical installation of the transducer. Improper installation can change the transducer amplitude and frequency response and/or generate signals that do not represent actual machine vibration. Upon request, we can provide engineering services to determine the appropriateness of housing measurements for the machine in question and/or to provide installation assistance. Page 1 of 6

Specifications Parameters are specified from +20 to +30 C (+68 to +86 F) and 100 Hz unless otherwise indicated. Hazardous Area Approvals Multiple approvals for hazardous areas certified by Canadian Standards Association (CSA/NRTL/C) in North America and by LCIE in Europe. Note: Operation outside the specified limits may result in false readings or loss of machine monitoring. Electrical Sensitivity: Frequency Response: 3.94mV/mm/s (100 mv/in/s) ±5%. North America: Ex ia IIC T4 AEx ia IIC T4 Class I, Div 1 Groups A, B, C & D Class II, Groups E, F, and G Class III Temperature Sensitivity: Velocity Range: Transverse Sensitivity: Amplitude Linearity: Mounted Resonant Frequency: Broadband Noise Floor (4.5 Hz to 2 khz): Maximum cable length: 4.5 to 2,000 Hz (270 to 120,000 cpm) ±3.0 db, 6.0 to 1,000 Hz (360 to 60,000 cpm) ±0.9 db. -14% to +7.5% typical over the operating temperature range. 1270 mm/s (50 in/s) peak. Less than 5% of sensitivity. ±2% to 152 mm/s (6 in/s) peak. Greater than 12 khz. 0.004 mm/s (160 µin/s) rms, nominal. 305 metres (1,000 feet) of cable, BN part number 02173007 with no degradation of signal. European/ATEX: IECEx: Brazil: Ex nl IIC T4 AEx na IIC T4 Class I, Div 2 Groups A, B, C & D Per DWG 167539 II 1 G Ex ia IIC T4 Ga II 3 G Ex na IIC T4 Gc Ex ia IIC T4 Ga Ex na IIC T4 Gc Ex ia IIC T4 Ga For further certification and approvals information please visit the following website: http://www.ge-mcs.com/en/bently-nevada.html Environmental Limits Operating Temperature Range: Shock Survivability: -55 C to +121 C (-67 F to +250 F) 5000 g peak, maximum Page 2 of 6

Relative Humidity: Magnetic Field Susceptibility: Physical Weight: Diameter: Height: To 100% non-submerged; case is hermetically-sealed. <51 µin/s/gauss (50 gauss, 50-60 Hz) 156 g (5.5 oz), typical 28 mm (1.1 in) 73.1 mm (2.88 in) Interconnect Cable 106765-AA A: Length in metres Minimum length: 1 metre (3.3 feet) Maximum length: 25 metres (82 feet) Order in increments of 3 metres. Terminal Housing Terminal Housing for terminating Velomitor XA Sensor cable to bulk cable listed above. The Terminal Housing provides local connection of the Velomitor XA Sensor signal wires to the monitor field wiring. Each Terminal Housing can accommodate up to 2 Velomitor XA Sensor Cables. 106769-AA A: Conduit Fitting Option 0 0 No fittings supplied 0 1 One ¾ NPT fitting 0 2 Two ¾ NPT fittings Case Material: Connector: Mounting Torque: Polarity: Cable Bend Radius: 316L stainless steel 2-pin Mil-C-26482 hermeticallysealed, 316L stainless steel shell. 45 N-m (33 ft-lb) maximum Pin A goes positive with respect to pin B when the sensor case motion is toward the connector. 1.5-in minimum bend radius. Note: Please read and understand the User Manual before attempting to install and use this product. Ordering Options Approvals 330525-AA A: Agency Approval Option 0 0 None Required 0 1 CSA/NRTL/C 0 2 SIRA/CENELEC Accessories 100076-01 02173007 103537-01 03839144 330500 Velomitor Sensor and Velomitor XA Sensor Manual. Bulk cable; 2 conductor twisted, shielded. 22 AWG cable without connectors or terminal lugs. Specify length in feet. Terminal Mounting Block. Provides simple field wiring connection and can be mounted inside any standard Proximitor Sensor housing. One terminal mounting block is needed for each Velomitor XA Sensor connection. Splash-resistant boot cover for interconnect cable assembly. The boot is made from fluorosilicone elastomer. Boot color is blue. Page 3 of 6

03839142 Bottom clamp used to secure the boot to the Velomitor XA Sensor case. 03839143 Top clamp used to secure the boot to the interconnect cable assembly. Page 4 of 6

Graphs and Figures 1 2 635 ± 76 (25.00 ± 3.00) 50.8 ± 13 (2.00 ± 0.50) 5 6 3 8 4 63.5 (2.50) 127 ± 13 (5.00 ± 0.50) 7 1. Splash-resistant boot with clamps 5. A (white) 2. Stainless steel armor over cable 6. B (black) 3. 0.382 mm 2 (22 AWG) 7. SHLD (green) 4. Clear shrink tubing 8. Overall length ± 200 (7.8) Figure 1: Dimensions for 106765 Cable Arial check all figure headings Dimensions are in millimeters (inches) Page 5 of 6

1 2 70.1 (2.76) 3 14.2 (0.56) 27.8 (1.096) 1. MIL-C-26482 receptacle 2. 25.4 (100) hexagonal 3. 1/4-18 NPT Figure 2: Dimensions for 330525 Velomitor XA Piezo-Sensor Dimensions are in millimetres (inches) * Denotes a trademark of Bently Nevada, Inc., a wholly owned subsidiary of General Electric Company. 1999 2014 Bently Nevada, Inc. All rights reserved. Printed in USA. Uncontrolled when transmitted electronically. 1631 Bently Parkway South, Minden, Nevada USA 89423 Phone: 775.782.3611 Fax: 775.215.2873 www.ge-mcs.com/bently Page 6 of 6