MEASURING & MONITORING OF SOLIDS FLOW. High-precision & safe Contact-free Maintenance-free

Similar documents
S300 Series Dust Monitors

Bulk Flow Meter LB 442 P R O C E S S C O N T R O L

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Various Technics of Liquids and Solids Level Measurements. (Part 3)

I BAU HAMBURG Dry Product Handling

Integrated pressure measurement

Corona process The new ZEISS spectrometer system for the food industry

BB-18 Black Body High Vacuum System Technical Description

Expertise in heavy loads. ThyssenKrupp freight elevators.

WEATHER STATION FOR SOLAR FARM MONITORING

How To Use A Flowmeter

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

Control- and feedback head for integrated mounting on Robolux valves Type 2036

COMBIMASS. Technical Data COMBIMASS eco-bio +

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

High Security Heavy Duty Shredders VZ Perfect shredding and high performance in DIN security levels 4 and 5

IFC 070 Technical Datasheet

Conductive Level Switch FK 2 Technical Data:

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Vacuum drying oven for non-flammable solvents

Encoders for Linear Motors in the Electronics Industry

TEMPERATURE MEASURING GALVANIC SEPARATORS CONVERTORS, PRESSURE MEASURING

Optimize Your Process

How To Use A Corona Mdi 110

Dew-Point Measurement Solutions

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

German engineering under high pressure

Cooking at the Speed of light!

T 300 Tray sealer. Automatic tray packaging in the smallest of spaces

2000 Series Ultrasonic Welding

Material test chamber with mechanical convection

Introducing the Improved MAS DRD "Waterless" Cleaning System for Plastic Film, Flakes and Fibers

Working width m

Variable V Area Flowmeter Rotameter The Original

Increased flexibility and greater cost-efficiency in profile extrusion 32D twin-screw extruders profile series. Engineering Value

Wirbelstrom Prüfsysteme. eddyliner. digital

EFC Frequency converters

Measurement & Analytics. VIS Multiphase Flow Meter High gas content applications solved with no radioactive source - Measurement made easy

S 700 K point machine. Setting points reliably.

Turbine Flowmeter Vision 1000 Flowrates 0,1-2,5L/min. Turbine Flowmeter Vision 2000 Flowrates 0,5-35L/min

How To Use A Ds340 (Dsp)

FACTORY AUTOMATION INTELLIGENT CLAMP MONITORING FOR MACHINE TOOL SPINDLES WITH INDUCTIVE POSITIONING SYSTEMS

Thermal Flow Sensor Die

User s Manual Inductive Analog Position Sensor BIL SmartSens No E Edition 0802

DUST EMISSION MONITORING SYSTEM

VZ/VZM SERIES Heavy Duty Shredders 600-2,100 kg/h

Series 6000 Torque measured metal bellow coupling

System Expertise for Machine Tools

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Volkmann Vacuum Conveying Applications. Powder Handling in the Pharmaceutical Industry: A Case Study

Online Infrared Flue Gas Analyzer Gasboard 3000

Bypass level indicator With magnetic display Model BNA

COMBIMASS. Thermal gas flow measurement system. For measuring and balancing of normal volumetric or gas mass flows

Batching and Mixing Plants

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Instruction Manual. T3111 T3111L T3111P T3111Ex

Product Information Sheet UH36 Hi Pot Tester

Name Class Period. F = G m 1 m 2 d 2. G =6.67 x Nm 2 /kg 2

T U R B I N E G A S M E T E R

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Power Supply Systems. Performance guaranteed. Power Supply Systems single-voltage UIC-systems multi-voltage UIC-systems

API Marine. BMS Presentation. Ballast Measurement Systems

EXTRUDER FEEDING SYSTEMS

Air technology solutions for demanding applications. Product overview.

Everything you need for protection scheme testing

Valve Remote Control Systems Centralized Hydraulics for marine vessels and offshore installations

Efficiency on a large scale CFB Steam Boilers

Recommendations Regarding the Handling of Norit GL 50 in Flue Gas Clean up Systems

How To Make A Fronius Cl Power Inverter

Turbine Flow Sensor Series VTR

SEISMIC MONITORING & PROTECTION SYSTEMS

Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards.

Monitoring Bulk Solids Inventory

Discharge station for bags and big bags. MKSB

Typical Aluminum GFM Mass Flow Meter

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Linear Parameter Measurement (LPM)

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

For Multi-Parameter Meters see mvx

Kolbenschmidt Pierburg Group

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

Sensor to Systems Connectivity Flexible, Reliable, Ultra Low-Power

Stellantriebe. Electrical Actuators. General Overview.

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Electric Coolant Pumps. Always at the Correct Temperature

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Thermal Mass Flow Meters and Controllers for Gases

ELECTROMAGNETIC FLOWMETER COMPACT

Single Mode Fiber Lasers

Micro Motion ELITE CMFS Series Meter

Combi switchbox with integrated 3/2 way pilot valve

Confidential. Proportional reducer D386 ATEX. Male base connector View from weld side

Transcription:

MEASURING & MONITORING OF SOLIDS FLOW High-precision & safe Contact-free Maintenance-free

DYNAguard Series FLOW MONITORS FOR BULK SOLIDS PROCESSES Easy monitoring bulk solids es Preventive & safe Compact Cost-effective Contact-free Maintenance-free The monitoring device DYNAguard represents the most direct implementation of the electrostatic or microwave measuring principle. The function of these devices allows for simultaneous integral monitoring of solids flow and transport velocity (such as behind sieves, filters or directly in the conveying duct) for reliable ing. Adaptation to the conveying and adjustment of the limits to be monitored is done through self-explanatory elements of operation in the electronic housing IP67. DYNAguard K P V Solutions to practical problems: shot-off & sealing dosing & feeding conveying & distribution The three pictures show application examples of the DYNAguard. Of course we are pleased to discuss with you the possibilities of customised specific adaptions. DYNAguard GM PARTICULATE MONITOR FOR FILTER FAILURE Broken bag Gross failure Assembly error The dust monitor DYNAguard GM is used for the detection of filter malfunction e.g. broken bag or assembly error. The DYNAguard technology is based on a modified triboelectric principle detecting particles interacting with the sensing rod and such particles just passing the rod. Build up on the rod surface will not be detected, only moving particles generate a flow rate proportional signal which is monitored by the electronics. Special design for small frames

DYNAguard M FLOW INDICATOR FOR SOLIDS Microwave technique Relay output The microwave-indicator DYNAguard M is used for monitoring the mass flow in open and closed transport es also with big distances between sensor and conveyed material. Independent of particles moving direction solid materials with velocity of at least 0.1 m/s will be detected by passing the microwave field. Conveying or feeding problems of powders, pellets or granules are detected early and thus should be avoided. This helps to prevent plant failures like clogging, material loss, idle or other serious difficulties. The measurement procedure of the DYNAguard is based on the physical principle of the Doppler effect. The sensor sends out a microwave field. If solids move through this field, the microwaves are reflected and received by the sensor again. The electronics unit converts this into a switching operation. DYNAguard TECHNICAL DATA model DYNA guardm DYNA guardp DYNA guardk DYNA guardgm detection area 1 m 30 mm DN 10 - DN 100 250 mm - max. 800 mm (sensor rod length) temperature (optional 200 C) (optional 200 C) (optional 230 C) pressure 2 bar (optional 25 bar) 6 bar (optional 40 bar) 40 bar 6 bar coupling G 1 1 / 2 G 1 1 / 2 DN 10 - DN 100 G 1 1 / 2 output transistor transistor transistor ATEX

DYNAvel FOR THE DETERMINATION OF SOLIDS VELOCITY High-precision & safe Contact-free Maintenance-free The DYNAvel measuring system provides a method that is just as reliable as it is accurate, which gives you the contactless determination of the actual solids velocity in pneumatic flow es as well as in free fall applications, but also at filaments, films or sheets. For each case of application, there is a multitude of Sensor Mechanics Units for the connection of the velocity measuring system to the stream. This can easily be changed due to the modular system architecture. The whole measurement system consists of sensor and a communication unit which are connected to each other via CAN-Bus circuit. On the CAN-Bus up to 10 DYNAvel can be connected. Thanks to the non-contact measurement no maintenance costs arise. DYNArad DYNArad combines the measurement values of density and velocity to determine the mass flow rate at pneumatic conveying es and free fall applications. In particular for the flue ash humidification control at power plants (up to 450 t/h) DYNArad has proved its worth worldwide. DYNA M-flow DYNA M-flow + DYNAvel CONCENTRATION & SPEED FLOW MEASUREMENT OF BULK SOLIDS WITH MICROWAVE-TECHNOLOGY IN-LINE measuring without weighing Contact less and integral measuring Cost-efficient - Compact - Easy For the determination of the mass flow rate at transport es with changing solids speed (e.g. pneumatic conveying) a combination of DYNA M-flow with the speed measurement DYNAvel is recommended. Using state-of-the-art microwave technology the solid flow meter DYNA M-flow is designed for flow measurement at metallic pipes from a few kg/h to many t/h. The system is suitable for on-line measurements of powders, dust, pellets, and granular from 1 nm up to 2 cm in pneumatic or free fall applications. The measurement principle of the DYNA M-flow is based on the physical Doppler-Effect, whereas the sensor generates a uniform field in the microwave frequency range inside the pipe. These microwaves are being reflected by particles passing through the pipe. Calculation of frequency and amplitude changes allows for accurate determination of solid flow. Nonmoving particles like dust accumulation are excluded from calculations.

DYNAchute MASS FLOW RATE OF HIGH ACCURACY BY DYNAMIC WEIGHING High accuracy Without calibration Unaffected by solids properties DYNAchute is a chute weigher that combines proven and highly accurate velocity measurement and weighing technology to determine the mass flow rate of bulk solids. In the robust controller PR1713, the two absolute values weight and velocity are calculated calibration-free to the flow and output in digital or analog form. An integrator and a dosing function allow batch weighing (kg) besides continuous dosing (kg/h). As a modification of the method used in belt weigher technology, the weight of the bulk solids is determined continuously on a chute segment using standard weighing technology. At the same time, the sliding speed rate is measured contact-free. From these two absolute, meaning calibration-free parameters, the system then determines the flow rate. The great advantage of these separate measuring operations is that the measuring result is not influenced by fluctuating product properties or by changing conditions. TECHNICAL DATA OF MEASURING SYSTEMS model DYNAvel DYNA M-flow DYNA M-flow + DYNAvel DYNArad DYNAchute measuring range 0.2 100 m/s min. 1 kg/h min. 1 kg/h min. 100 kg/h min. 100 kg/h accuracy 0,5 % 3% 2 % 1 % 1 % temperature -20 / 130 C (optional 180 C) (optional 130 C) -20 / 130 C 0 / 50 C pressure 64 bar 1 bar (optional 40 bar) 1 bar (optional 40 bar) 64 bar ± 0.1 bar coupling up to DN 400 mm up to DN 200 mm up to DN 200 mm up to DN 400 mm 100-400 mm output RS 485, ethernet RS 485, pulse-output RS 485, ethernet RS 485, ethernet ATEX

Robust and proven technologies High application expertise In-house development In-house production Made in Germany WE ARE DEVELOPING AND PRODUCING SOLUTIONS FOR MORE THAN 15 YEARS DYNA Instruments GmbH Tempowerkring 7 D-21079 Hamburg fone: + 49 (0)40 79 01 85-0 fax: + 49 (0)40 79 01 85-18 mail: info@dynainstruments.com web: www.dynainstruments.com Contact your national or area sales and service office Technical data subject to change without notice DYNAInstruments_E01/012012 All data describe our products in a general manner. They are not warrenty of characteristics in the sense of 459, Paragraph 2 of the German Civil Code or similar regulations and effect no liability.