Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Similar documents
4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Pressure reducing valve, direct operated, Type ZDR 6 D

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

2-way flow control valve Type 2FRM 6

3/2- and 2/2-way cartridge valve type BVE

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

2/2 and 3/2 Way Size 6 Seat Valves

Pressure and flow control system

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

Proportional pressure regulators VPPE

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Analog Command Value Card Type VT-SWKA-1

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Chapter 5: Flow Valves

Fixed displacement vane pumps

Electro-hydraulic pressure switches type DG

Load-sensing control block in mono and sandwich plate design

Chapter 6: Check Valves

3/2 Solenoid Cartridge Valve, Size 6

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Open center control block in monoblock design MO-40

4/2-Way Pneumatic Solenoid Valve

Pressure relief valves Size 6

Single sub-base valve

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Assisted lift operated 2/2-way solenoid valves Type EV250B

Unit 24: Applications of Pneumatics and Hydraulics

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Directional seated valves type VP 1

3/2-way Solenoid Valve, direct-acting, NC or NO

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

HERZ-Thermal Actuators

Electro-pneumatic control valves

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Pressure transmitter For general industrial applications Model A-10

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Cable Plug acc. to DIN EN , Form A

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Actuators and Sensors. Products

Proportional Pressure Reducing Valves

Hydraulic Flow Control Valves

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Mounting Instructions. Torque Transducer. A en

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Coils - Connectors. Coils Connectors. Summary. RE /03.16 Replaces: RE / Description

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

E-STOP relays, safety gate monitors

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Digital inductive conductivity transmitter

How To Use A Flowmeter

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Hydraulic Control Solutions

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

System 8. ü ( System 8

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Instruction Manual Differential Pressure Transmitter

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

type V46, solenoid or pneumatic operated

Contact expansion modules

Safety technique. Emergency stop module BO 5988 safemaster

Inductive sensor NI10-M18-Y1X-H1141

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Combi switchbox with integrated 3/2 way pilot valve

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

SOLENOID VALVES 3-4 WAY

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Coils - Connectors. Coils Connectors. Summary. RE / /10 Replaces: RE / Description

Electronic Pressure Switch EDS 300

Seat Valves. 1 Description. Series SVH Technical data. 1.2 Performance graphs

Electronic Pressure Switch EDS 3000

G1/4 Q8. Standard with biased position

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

4 Posiflow Proportional Solenoid Valves

Proportional Pressure Relief Valves

3-Component Measuring System

Control blocks for two-hand start ZSB

Hydraulic cylinders Tie rod design. Type CD70 / CG70. Contents. Features. RE Edition: Replaces: 08.08

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Transcription:

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback RE 29163/07.05 1/12 Type DBEBE10Z Nominal size 10 Unit series 1X Maximum working pressure A, B, X 315 bar, Y 2 bar Maximum flow rate Q nom 120 l/min List of Contents Contents Page Features 1 Ordering data 2 Preferred types, symbol 2 Function, sectional diagram 3 Technical data 4 to 6 On-board trigger electronics 7 and 8 Characteristic curves 9 Unit dimensions 10 Features Pilot operated valves with position feedback and on-board electronics for limiting system pressure (pilot oil internal only) Adjustable through the position of the armature against the compression spring With position control, minimal hysteresis < 1 %, rapid response times, see Technical Data Pressure limitation to a safe level even with faulty electronics (solenoid current I > I max ) For subplate attachment, mounting hole configuration to ISO 5781-AG-06-2-A Subplates as per catalog sheet RE 45055 (order separately) Plug-in connector to DIN 43563-AM6, see catalog sheet RE 08008 (order separately) Data for the on-board trigger electronics Complies with CE, EMC directives EN 61000-6-2: 2002-08 and EN 61000-6-3: 2002-08 U B = 24 V nom DC Electrical connection 6P+PE Signal actuation Standard 0...+10 V (A1) Version 4...20 ma (F1) Valve curve calibrated at the factory

2/12 Bosch Rexroth AG Hydraulics DBEBE10Z RE 29163/07.05 Ordering data DBEB E 10 Z 1X XY G24 K31 A1 M * Proportional pressure relief valve with inductive position transducer on the cone With on-board electronics = E Nominal size = 10 Mounting hole configuration to = Z ISO 5781-AG-06-2-A Unit series 10 to 19 = 1X (10 to 19: installation and connection dimensions unchanged) Max. pressure stage up to 180 bar = 180 up to 315 bar = 315 Relief port X Pilot oil port Y = XY * Variant F1 (4...20 ma version) available on request G24 = A1 = K31 = M = Further information in plain text NBR seals, suitable for mineral oils (HL, HLP) to DIN 51524 Interface for trigger electronics* Setpoint input 0...+10 V Electrical connection without plug-in connector, with unit plug to DIN 43563-AM6 Order plug-in connector separately Voltage supply of trigger electronics 24 V DC Preferred types Type...A1 (0... +10 V) Material Number DBEBE10Z 1X/180XYG24K31A1M 0 811 402 115 DBEBE10Z 1X/315XYG24K31A1M 0 811 402 116 Symbol For on-board electronics D E A Y X B

RE 29163/07.05 DBEBE10Z Hydraulics Bosch Rexroth AG 3/12 Function, sectional diagram General Type DBEBE10Z proportional pressure relief valves are pilot operated and are used to limit system pressure. They are actuated by means of a position-controlled proportional solenoid with on-board electronics. The valve body contains a logic element (poppet valve) of the normally closed type. This is pilot operated and is in conical seat design. EN 61000-6-2: 2002-08 EN 61000-6-3: 2002-08 Basic principle To adjust the system pressure, a setpoint is set in the trigger electronics. Based on this setpoint, the electronics control the position-controlled solenoid. The proportional solenoid maintains its position against a spring force, which is proportionate to the system pressure. The pilot stage is supplied with pilot oil at a flow rate of < 0.8 l/min through a bore. The p max pressure stage is determined by the cone and seating bore configuration. Pressure limitation for maximum safety If a fault occurs in the electronics, so that the solenoid current (I max ) would exceed its specified level in an uncontrolled manner, the pressure cannot rise above the level determined by the maximum spring force. Proportional solenoid with position transducer Pilot valve Poppet valve cartridge Alternative Accessories Type Material Number (4 x) f ISO 4762-M10x80-10.9 Cheese-head bolts 2 910 151 309 * Plug-in connectors 6P+PE, KS 1 834 482 022 see also RE 08008 KS 1 834 482 026 MS 1 834 482 023 MS 1 834 482 024 KS 90 1 834 484 252 Testing and service equipment Test box type VT-PE-TB3, see RE 30065 Measuring adapter 6P+PE type VT-PA-2, see RE 30068

4/12 Bosch Rexroth AG Hydraulics DBEBE10Z RE 29163/07.05 Technical data General Construction Pilot stage Poppet valve Main stage Pressure relief valve Valve cartridge Poppet valve, normally closed, with pilot oil bore Actuation Proportional solenoid with position control and OBE Connection type Subplate, mounting hole configuration NG10 (ISO 5781-AG-06-2-A) Mounting position Optional Ambient temperature range C 20...+50 Weight kg 7.8 Vibration resistance, test condition Max. 25 g, shaken in 3 dimensions (24 h) Hydraulic (measured with HLP 46, oil = 40 C ±5 C) Pressure fluid Hydraulic oil to DIN 51524...535, other fluids after prior consultation Viscosity range, recommended mm 2 /s 20...100 max. permitted mm 2 /s 10...800 Pressure fluid temperature range C 20...+70 Maximum permitted degree of contamination of pressure fluid Purity class to ISO 4406 (c) Class 18/16/13 1) < 190 < 325 Direction of flow See symbol Max. set pressure (at Q min = 1 l/min) bar 180 315 Minimum pressure (at Q min = 1 l/min) bar 6 8 Max. mechanical pressure limitation bar level, e.g. when solenoid current I I max Max. working pressure bar Port A, B: 315 Port Y: 2 external pilot oil drain Port X: 315 relief port Internal pilot oil flow l/min 0.8 Max. flow l/min 120 for Q max, see Characteristic Curves Static/Dynamic Hysteresis % 1 Manufacturing tolerance for p max % ±5, see Characteristic Curves Response time 100 % signal change ms 80 dependent on dead volume or system volume Thermal drift < 1 % at T = 40 C Conformity EN 61000-6-2: 2002-08 EN 61000-6-3: 2002-08 1) The purity classes stated for the components must be complied with in hydraulic systems. Effective filtration prevents problems and also extends the service life of components. For a selection of filters, see catalog sheets RE 50070, RE 50076 and RE 50081.

RE 29163/07.05 DBEBE10Z Hydraulics Bosch Rexroth AG 5/12 Technical data Electrical, trigger electronics integrated in valve Cyclic duration factor % 100 % Degree of protection IP 65 to DIN 40050 and IEC 14434/5 Connection Plug-in connector 6P+PE, DIN 43563 Supply voltage Terminal A: Terminal B: 0 V 24 V DC nom Min. 21 V DC/max. 40 V DC Ripple max. 2 V DC Power consumption Solenoid 45 mm = 40 VA max. External fuse 2.5 A F Input, standard version A1 Differential amplifier, R i = 100 kω Terminal D: U E Terminal E: 0...+10 V 0 V Input, ma signal version F1* Terminal D: I D E Terminal E: I D E Max. voltage to differential inputs over 0 V Test signal, standard version A1 Terminal F: U Test Terminal C: Test signal, ma signal version F1* Terminal F: I F C Terminal C: I F C Safety earth conductor and shield Recommended cable Burden, R sh = 200 Ω 4...20 ma Current loop I D E feedback D B E B } max. 18 V DC LVDT 0...+10 V Reference 0 V Calibration * Variant F1 (4...20 ma version) available on request Version A1: Standard LVDT signal 4...20 ma at external load 200...500 Ω max. 4...20 ma output Current loop I F C feedback See pin assignment (installation in conformity with CE) See pin assignment up to 20 m 7 x 0.75 mm 2 up to 40 m 7 x 1 mm 2 Calibrated at the factory, see valve curve Supply 24V = Signal: 0 +10V A LVDT Signal: 0 +10V (Ri = 100kΩ) 7 5 Y X B * Version F1: ma signal Supply 24V = Signal: 4 20mA LVDT Signal: 4 20mA (Bürde: 200Ω) 1 A 5 Y X B

6/12 Bosch Rexroth AG Hydraulics DBEBE10Z RE 29163/07.05 Connection For electrical data, see page 5 and Operating Instructions 1 819 929 083 Technical notes for the cable Version: Type: Multi-wire cable Extra-finely stranded wire to VDE 0295, Class 6 Safety earth conductor, green/yellow Cu braided shield e. g. Ölflex-FD 855 CP (from Lappkabel company) No. of wires: Determined by type of valve, plug type and signal assignment Cable Ø: Outside Ø: 0.75 mm 2 up to 20 m long 1.0 mm 2 up to 40 m long 9.4...11.8 mm Pg11 12.7...13.5 mm Pg16 Important Power supply 24 V DC nom., if voltage drops below 18 V DC, rapid shutdown resembling Enable OFF takes place internally. In addition, with the ma signal version: I D E 3 ma valve is active I D E 2 ma valve is deactivated. Electrical signals emitted via the trigger electronics (e.g. actual values) must not be used to shut down safety-relevant machine functions! (See also European Standard, Technical Safety Requirements for Fluid-Powered Systems and Components Hydraulics, EN 982.

RE 29163/07.05 DBEBE10Z Hydraulics Bosch Rexroth AG 7/12 On-board trigger electronics Circuit diagram/pin assignment Version A1: U D E 0...+10 V Supply U B Supply zero Ref. zero * Setpoint 0...+10 V Actual value 0...+10 V Safety earth conductor Shield * Do not connect to supply zero! Pin assignment Version A1: U D E 0...+10 V (R i = 100 kω)

8/12 Bosch Rexroth AG Hydraulics DBEBE10Z RE 29163/07.05 On-board trigger electronics Circuit diagram/pin assignment Version F1: I D E 4...20 ma OBE 2.5 AF +24 V= Supply +U B +15 V -15 V DC DC Logic Diff. amp. ma V R sh 200Ω 4 20mA A B C D E F 0 V Supply zero Loop I F C I D E 4...20 ma Test I F C (4...20 ma) Safety earth conductor Shield +U B + - PID S U Pin assignment 6P+PE Version F1: I D E 4...20 ma (R sh = 200 kω)

RE 29163/07.05 DBEBE10Z Hydraulics Bosch Rexroth AG 9/12 Characteristic curves (measured with HLP 46, oil = 40 C ±5 C) Pressure in port A as a function of the setpoint * Factory setting at Q = 1 l/min ±5 % manufacturing tolerance 1) Version: U D E = 0...+10 V 2) Version: I D E = 4...20 ma U D-E 1 ) [V] 4,0 7,2 10,4 13,6 16,8 20 I D-E 2 ) [ma] Pressure in port A as a function of the main stage nominal flow rate p = f (Q)

10/12 Bosch Rexroth AG Hydraulics DBEBE10Z RE 29163/07.05 Unit dimensions (nominal dimensions in mm) Not included in scope of delivery Mounting hole configuration: NG10 (ISO 5781-AG-06-2-A) For subplates see catalog sheet RE 45055 1) Deviates from standard 2) Thread depth: Ferrous metal 1.5 x Ø* Non-ferrous 2 x Ø * NG10 min.10.5 mm Required surface quality of mating component X Y A B X Y G F 1 F 2 F 3 F 4 27.2 35.8 21.4 21.4 31.8 0 42.9 42.9 20 33.35 33.35 58.7 27,9 66.7 0 20 66.7 66.7 14.7 14.7 24.8 24,8 27.5 M10 2) M10 2) M10 2) M10 2)

RE 29163/07.05 DBEBE10Z Hydraulics Bosch Rexroth AG 11/12 Notes

12/12 Bosch Rexroth AG Hydraulics DBEBE10Z RE 29163/07.05 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Telefon +49 (0) 93 52 / 18-0 Telefax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.