In-wall, fan-driven, zone-controlled heat. Hydronic

Similar documents
IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

Synergy of demand water heaters with solar and radiant floor heating

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Fully Pumped Systems

High Efficiency Heating

Low Profile Unit Cooler

With colder weather approaching and heating costs continuing to skyrocket, ASHRAE is offering some simple ways to save energy and keep you and your

Energy Efficiency. Energy Efficient Home Cooling:

Domestic Hot Water Systems and Plumbing Products

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

warm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%.

ZUBA-CENTRALTM. Heating & Cooling. Evolved. HEATING AND AIR CONDITIONING FOR WHOLE-HOME, YEAR-ROUND COMFORT

Nordic Heat Pump Product Guide

MAC-120HE-01 Air-Cooled Chiller

PLBG/GAS SAFETY Information Bulletin

SECTION Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)

The space saving solution.

Cast Iron Radiator Heating Capacity Guide

Fan Convector Technical Specifications January 2006 Rev A

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

General Information. Do programmable thermostats really save energy?

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

GENERAL SUPPLEMENT 410. Radiantec CONTROLS FOR RADIANT HEATING CONTROLS PURPOSE OF RADIANTEC CONTROLS

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

INSTALLATION AND OPERATION MANUAL

HVAC Processes. Lecture 7

Slide 1. Slide 2. Slide 3 288,817,200,000. Thank you for attending the session on Hot Water Re-Circulation.

When considering your heating options, keep in mind that 60% of your energy. costs are attributed to space heating. You

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

ETS - Electric Thermal Storage Heating

LSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS

Why Daikin? 2015 Houston, Texas USA

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Glossary of Heating, Ventilation and Air Conditioning Terms

Overview of Baseboard Heating

Explosion-Proof Electric Unit Heaters

KONRAD. Hybrid Fancoil Series

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Delivering exceptional performance and Ecovalue. Ecocent

ENERGY EFFICIENT HEATING

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

Installation Questions

A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

HYDRONIC DESIGNER / INSTALLER MODULE DESCRIPTIONS

It Pays. To Save Energy FPO. Guide to Xcel Energy rebates, incentives and programs for residential customers in Minnesota

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

Test Code: 8297 / Version 1

CHAPTER 10: APPLIANCES AND LIGHTING

Energy Efficiency. Energy Efficient Water Heating: Purchasing a new electric water heater. Hot water use has a significant impact on your bill.

Condensing Boiler Efficiency

Building Energy Systems. - HVAC: Heating, Distribution -

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

Geothermal Comfort Systems

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Cooling Capacity CFM in. w.c. (125 Pa)

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

DESIGN AND CONSTRUCTION SUGGESTIONS

AHE S SERVICE MANUAL

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

Trane EnviroWise Geothermal Systems. Renewable energy keeps the comfort coming.

Cooling/Heat Pump Convertible Air Handlers

SAVE ENERGY AT HOME INSULATE AND AIR SEAL

RECON WATER HEATER INSTALLATION FORM

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

Features and Benefits. Product Overview. Installation Overview. Sales Strategy Overview FPO

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Floor Heating Warehouse.co.uk

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

Greensource iseries HY Model Unitary Air Handler/Fan Coil

Selecting a New Water Heater

1/9/2015. Create Energy Saving Comfort & Cut Costs with Affordable HVAC Zone Controls. Educate Builders on the Importance of ZONING.

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Printing and Publishing Energy Savings Guide

In Part 1 of this article (see January/February 2005

DIABLO VALLEY COLLEGE CATALOG

RESEARCH HIGHLIGHT. The Impact of Heat Pump Water Heaters on Whole-House Energy Consumption

High efficiency, cast-iron gas boiler

Principals of Condensing Boiler System Design

National Grid Small Business Energy Efficiency Program Overview. Central New York Energy Expo March 30, 2010

SunMor SM-V30 Solar Water Heater Installation Manual

Thermal Imaging for Home Inspectors

White paper on the comparative energy efficiency of zoned electric heaters Convectair, Inc. / Convectair-NMT Inc. September 2004

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

innovative comfort solutions

Versati Air to Water Heat Pump

COMMISSIONING OF HVAC SYSTEMS

ECO-AIR AIR CONDITIONING

CONDENSING TANKLESS WATER HEATERS

Boiler Applications Drawings

Local Dealer:

FTQ. Daikin Inverter Ducted Heat Pump

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Basic Nameplate Information

Transcription:

H series HT series HM series HME series HL series HLE series In-wall, fan-driven, zone-controlled heat. Hydronic Heats efficiently using energy from typical hot water source.

Hydronic. Comfort everywhere. Heat only the rooms which need it, borrowing energy from what s already there: the hot water heater. Compatible with typical hot water sources Reduce utility bills with individual room control Built well with high quality components More free space: no furnace room needed Safe for use with potable water Quiet operation H HT Hydronic wall-mount unit for bedroom and bathroom applications. 1800 to 10,500 Btu Hydronic Toe-Space unit for kitchen under-cabinet applications. 1700 to 9950 Btu HW Special King system-matched two-step thermostats provide precision zone control and smooth, consistent low-cost hydronic heat. HM HME HL HLE Hydronic medium and large size units for entry ways, large rooms or hallways. ECM versions offer the best heat and energy savings. 4690 to 27,250 Btu King s hydronic system offers cost-saving zone control, heat source sharing, near silent operation, quality construction, and easy installation. 2

How does King s hydronic system work? The concept is simple: Redirect existing hot water rather than expend energy to create a new heat source. King s hydronic heating system uses hot water from your hot water tank (any hot water source gas, electric, solar, etc.), passes it through highly efficient radiant heat plates, and returns the hot water to your tank. Inside the heater, a gentle fan draws room-temperature air across the radiant plates where the air is warmed before being pushed back out into the room. But the real magic is in our thermostat system, which maintains consistent individual room temperatures while using the smallest amount of energy possible. How does King s ECM fan and thermostat work together? The King HW system-matched thermostat has two steps. The first makes sure hot water is moving over the radiant plates, and the second activates the quiet, low-rpm fan once the radiant plates are up to temperature. The energy-saving ECM (electrically commutated motor) version has a progressive RPM which, in conjunction with the thermostat, adjusts airflow only as much as is needed to maintain room temperature. The HW thermostat controls the room temperature as accurately as + /- one degree (compared to + /- five degrees of other hydronic systems). Energy is saved because the unit begins heating when room temperature drops slightly, and runs briefly, just enough to bring the room back to temperature. System-matched King thermostats. model HW model HWP * model HWPT manual adjustment programmable seven-day temperature cycles programmable, with automatic pump cycle for 15 minutes every 24 hours. 40 watts standard motor 10 watts ECM motor Electronic line-powered 2-step hydronic fan coil thermostats UPC # 093319 Model Number Description 19048 HW120 120V 12AMP ELECTRONIC, 2 STEP - 3 WIRE 19047 HWP120 7-day programmable. 120V 12AMP, 2 STEP - 3 WIRE 19049 HWPT120 120V 12AMP ELECTRONIC 2 STEP, WITH 24-HOUR PUMP TIMER Tested to UL873 File E244053 * for use with potable hot water systems Why King s hydronic system makes sense today: Utilizes a hot water system already in place Minimal components to install, uses flexible hot-water lines Minimal floor space used no furnace footprint Maximized energy savings with ECM fan and two-step thermostat Single room temperature control lowers cost Near-silent operation, smooth, consistent, comfortable room heat Less temperature fluctuation than typical systems High-quality, American-made constuction means low maintenance Easier to install than forced air ducting Works with typical hot water energy source: gas, electric, solar, etc. 3

Hydronic. Comfort everywhere. Water heater, tankless water heater or boiler. 140º 160º Hot Water Source OPEN LOOP Hydronic System check valve < Domestic Cold Water Tempering Valve 120 Circulation Pump 120v power to pump To Domestic Hot Water 120 120v power to fan on one minute delay expansion tank check valve This drawing is a general diagram and was simplified for clarity. Other components like ball valves, check, bleed zone valves, pressure gauges or temperature wells may be required in the system to operate properly. 14/3 wire to each thermostat j-box. Third wire is pump power. L1 N 14/2 wire from j-box to heater. 15 amp maximum circuit size. 4

< Domestic Cold Water expansion tank Water heater, tankless water heater or boiler. CLOSED LOOP Hydronic System (isolated from potable water) < Domestic Hot Water Tempering Valve 120 check valve 140º 160º Hot Water Source check valve < Domestic Cold Water Circulation Pump 120v power to pump This drawing is a general diagram and was simplified for clarity. Other components like ball valves, check, bleed zone valves, pressure gauges or temperature wells may be required in the system to operate properly. expansion tank heat exchanger 120v power to fan on one minute delay 14/3 wire to each thermostat j-box. Third wire is pump power. 14/2 wire from j-box to heater. L1 N 15 amp maximum circuit size. 5

Hydronic. Comfort everywhere. Hydronic Small Model Number Volts Can Size Grille Size H412 all versions 120 9½"h x 14 3 /8"w x 4¾"d 10½"h x 15¾"w x 7 /8"d H612 all versions 120 11"h x 14 3 /8"w x 4 ¾"d 12 ½"h x 15 ¾"x 7 /8"d All King hydronic heaters are tested to UL 1995 standards. Approved for USA and Canada CSA /C22.2 1800 to 10,500 Btu H MODEL H412 2/3 H412 3/4 H612 4/5 H612 6/8 FINS PER INCH Btu@2GPM 200ºF 93ºC AMPS RPM CFM 4.36 High Speed 1,800 2,500 3,600 3,500 4,100.54 2000 80 4.36 Low Speed 1,200 1,400 1,700 2,000 2,300.51 1750 50 8.36 High Speed 2,200 3,100 4,000 4,800 6,100.54 2000 80 8.36 Low Speed 1,200 1,800 2,400 3,000 3,800.51 1750 50 4.54 High Speed 3,600 4,700 5,800 7,100 8,500.48 2550 120 4.54 Low Speed 3,200 4,000 5,000 6,100 7,300.40 1850 105 8.54 High Speed 4,100 6,000 7,600 9,100 10,500.48 2500 120 8.54 Low Speed 3,700 5,200 6,500 7,900 9,600.40 1850 105 * most common water temperature range Hydronic toe-space, under-cabinet 1700 to 9950 Btu Model Number Volts Can Size Grille Size HT all versions 120 3 3 /8"h x 18¼"w x 13½"d 3 3 /8"h x 20"w x ¾"d HT MODEL FINS PER INCH Btu@2GPM 200ºF 93ºC AMPS RPM CFM HT412 2/3 HT612 4/5 HT612 5/6 8.36 High Speed 1,700 2,500 3,400 4,600 5,200.54 2000 83 8.36 Low Speed 1,600 2,400 3,200 4,000 5,000.51 1800 76 8.54 High Speed 2,800 4,000 5,100 6,900 8,200.54 2000 83 8.54 Low Speed 2,400 3,250 4,350 6,000 6,500.51 1800 76 H series 8.72 High Speed 3,600 5,000 6,600 7,500 9,950.54 2000 83 8.72 Low Speed 3,200 4,300 5,400 7,000 8,400.51 1800 76 * most common water temperature range Aqua stat: turns on fan when radiant plates reach 115 F. To specify aqua stat add AS to model number. Fan switch: optional two-speed fan switch with center off. To specify fan switch add FS to model number. Grille colors: available in white, black or almond. To specify, add GW for white, GB for black, or GA for almond. Coils are made of copper alloy 122 manufactured to ASTM B-75 specifications. Brazing alloy is AWS-BCUP2 for use with potable water systems. Electrical circuit size: 15 amp maximum. Model Number Legend H 6 12 6/8 AS-FS GW GW Grill White AS-FS Aqua Stat / Fan Switch 6/8 6000 Btu heat output @ 140 Degree 8000 Btu heat output @ 160 Degree water input 12 Voltage 120 water input 6 Number of copper tubes in coil H H Series Hot Water 6 Btu ratings based on 68º entering air. To calculate 1 GPM, multiply by 0.95. To calculate 4 GPM, mulitply by 1.05.

Hydronic Medium and Hydronic Medium with ECM Model Number Volts Can Size Grille Size HM & HME 812 & 1012 all versions 120 21¾"h x 14 ¼"w x 4¾"d 23¼"h x 15½"w x ¾"d 4960 to 18,700 Btu HM Unit Bearing Motor Motor Hi/Lo CFM Decibles at 3-ft distance Hi/Lo: Amps Hi/Lo: Watts HM812 6/9.72 4800 Btu 3300 Btu 6250 Btu 4900 Btu 9500 Btu 7100Btu 13700 Btu 11000 Btu 3 watt output 250 /150CFM Hi 55 dba Lo 52 dba.30/.29 Amps 36/34.8 Watts HM812 8/11.72 6000 Btu 4800 Btu 8550 Btu 7100 Btu 11200 Btu 8000 Btu 14800 Btu 11000 Btu 5 watt output Hi 62 dba Lo 58 dba HM1012 10/13.90 7500 Btu 5500 Btu 10000 Btu 7900 Btu 13500 Btu 9750 Btu 16600 Btu 12000 Btu 3 watt output 250 /150CFM Hi 55 dba Lo 52 dba.30/.29 Amps 36/34.8 Watts HM1012-11/15.90 6600 btu 8800 btu 14000 btu 5 watt output Hi 62 dba Lo 58 dba HME ECM Motor Progressive CFM Run/Start Energy saver HME 812-8/11.72 6000 Btu 4800 Btu 8550 Btu 7100 Btu 11200 Btu 8000 Btu 14800 Btu 11000 Btu 150 to 375 High 150 to 250 Low Hi 57/54 dba Lo 54/51 dba.06 /.04 Amps 7.2 /4.8 Watts HME1012-11/15.90 6600 btu 8800 Btu 14000 btu 150 to 375 High 150 to 250 Low Hi 63/60 dba Lo 54/51 dba.09 /.06 Amps 10.8 /7.2 Watts * most common water temperature range Hydronic Large and Hydronic Large with ECM. Model Number Volts Can Size Grille Size HL & HLE 1012 & 1412 all versions 120 24¾"h x 14 ¼"w x 4¾"d 26¼"h x 15½"w x ¾"d 6700 to 27,250 Btu HL Unit Bearing Motor Motor Hi/Lo CFM Decibles at 3-ft distance Hi/Lo: Amps Hi/Lo: Watts HL1012 8/11.90 6000 Btu 4700 Btu 8550 Btu 6200 Btu 11100 Btu 8000 Btu 14800 Btu 11000 Btu 3 watt output 250 /150CFM Hi 57/55 dba Lo 54/52 dba.30/.29 Amps 36/34.8 Watts HL1012 10/13.90 7500 Btu 5500 Btu 10000 Btu 8000 Btu 13500 Btu 9750 Btu 16600 Btu 12000 Btu 3 watt output 250 /150CFM Hi 57/55 dba Lo 54/52 dba.30/.29 Amps 36/34.8 Watts HL1012-11/15.90 6600 btu 8800 btu 14000 btu 5 watt output Hi 64/62 dba Lo 60/58 dba HL1412-15/20 1.2 10600 Btu 7400 btu 20000 Btu 15000 Btu 26000 Btu 19500 Btu 5 watt output Hi 64/62 dba Lo 60/58 dba HL1412-20/25 1.2 17000 Btu 13000 Btu 20000 Btu 16800 Btu 24050 Btu 19100 Btu 27250 Btu 22500 Btu 9 watt output Hi 64/62 dba Lo 60/58 dba HLE ECM Motor Progressive CFM Energy saver HLE 1012-11/15.90 6600 btu 8800 btu 14000 btu 150 to 375 High 150 to 250 Low Hi 57/55 dba Lo 54/52 dba.06 /.04 Amps 7.2 /4.8 Watts HLE 1412-15/20 1.2 10600 Btu 20000 Btu 26000 Btu 150 to 375 High 150 to 250 Low Hi 63/61 dba Lo 54/52 dba.09 /.06 Amps 10.8 /7.2 W * most common water temperature range 7

Hydronic. Comfort everywhere. King: Made to last. All King hydronic heaters are tested to UL 1995 standards. Approved for USA and Canada. CSA /C22.2 At King, we take great pride in standing behind our products, inside and out. We go beyond certification requirements, and execute a build quality we can be personally proud of. When you purchase King, you re buying peace-of-mind, knowing you re dealing with a strong U.S.A. manufacturer serving the trades and consumers for over fifty years. The optional aqua stat component makes sure the water temperature is over 115º before the fan is turned on. All models include a pre-wired, clear, easy-to-read terminal board with wiring diagram. The optional fan speed switch allows fan speeds of high, low and a center off position. HM HME HL HT Non-clogging radiant plate heat exchanger air flow-through design 2 speed motor H wall box HLE Whisper-quiet blower Wing tabs for quick wall box installation 5/8" tubing The H and HT series use a silent-running squirl-cage fan. The HM and HL use a four-pole unit-bearing motor. The HME and HLE use a DC computer-controlled two-pole motor. All of King s hydronic heaters carry a five year warranty. Why King? Since 1958 King Manufacturing Company has been a leader in the heating industry, with several patents to our credit. In this age of conglomeration, big business, and a global economy, King is still proudly family-owned and continuously based out of Seattle, Washington. Our products are made right here in the good ol U.S.A. In our 50 years we have seen exciting changes in the comfort and convenience of heating homes and businesses. Technology has improved to create exciting new possiblilities in established heating systems. King continues to emphasize research and development, product quality, and genuine pride to ensure that our customers enjoy the best heating options possible at any given time. Designed and manufactured in the United States. Residential or commercial electric heat: at King we anticipate your needs and provide you with the best!