FTTH FOR THIS CENTURY: HOW TO BUILD NETWORKS THAT LAST AND SURVIVE FUTURE REQUIREMENTS

Similar documents
Increasing Data Traffic Requires Full Spectral Window Usage In Optical Single-Mode Fiber Cables

OFS AllWave Zero Water Peak (ZWP) single-mode

MTS/T-BERD Platforms Very Long Range (VLR) OTDR Module

Fiber-to-the-Home/FTTH

FTTH ARCHITECTURE WHITE PAPER SERIES

FTTH ARCHITECTURE WHITE PAPER SERIES

DATA CENTER CABLING DESIGN FUNDAMENTALS

Fiber Characterization Service

Next Generation Optical Fibre: Making Your Broadband Network Go Further

TROUBLESHOOTING AT THE SPEED OF LIGHT EMBEDDED OTDR FOR OPERATIONAL EXCELLENCE IN PASSIVE OPTICAL NETWORKS

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Properties and Potential Applications of a Bend Optimised Singlemode Optical Fibre

FTTX Solutions FDH 3000 Cross-Connect

WDM-PON: A VIABLE ALTERNATIVE FOR NEXT GENERATION FTTP

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

New Installation and Maintenance Tools for CWDM Networks

Field Measurements of Deployed Fiber

Application Note Fiber Optic Standards Reference Guide

OSMIUM HIGH DENSITY FIBER OPTIC CHASSIS

Cabling & Test Considerations for 10 Gigabit Ethernet LAN

200-Micron Single-Mode Fiber Enables New Cable Designs Copyright 2014 OFS FITEL, LLC

BroadbandSoHo. Verizon MDU FTTP Overview. Document Description:

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and optical systems characteristics Optical fibre cables

Understanding and Optimizing MDU Optical Cabling Systems

The Infrastructure of Tomorrow, Available Today. Luca Rozzoni RCDD Business Line Manager TE Connectivity

Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces

Cisco - Calculating the Maximum Attenuation for Optical Fiber Links

Fiber to the Home: Enabling Innovation & Growth. Stuart Elby, PhD Vice President -- Technology

Passive Optical Networks: Recent Developments and Issues

Gigabit Passive Optical Networks

Competition for consumer voice,

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

PON Technology A Shift in Building Network Infrastructure. Bob Matthews Technical Manager CommScope Canada

FTTH Technology Developments and Trends. Stephen Hardy Editorial Director & Associate Publisher Lightwave

Aurora Networks, Inc.

4 Small Cables Sealing Kit: Wrap Style

FTTH Explained: Delivering efficient customer bandwidth and enhanced services Michael Kunigonis Product Line Manager Access Corning Cable Systems

Cisco SFP Optics for Gigabit Ethernet Applications

Enhanced xdsl solutions Deploy faster and lower your costs

DATA CENTER APPLICATIONS REFERENCE GUIDE Networking & Storage

Infrastructure for the next three generations

Connect & Go with WDM PON Ea 1100 WDM PON

Genexis FTTH Network Architecture

Alcatel 7342 Intelligent Service Access Manager (ISAM) Fiber to the User (FTTU)

Gigabit Ethernet Copper-to-Fiber Converters

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

Guidelines. LANscape Solutions Recommended Fiber Optic Test Guidelines. Table of Contents. 1. Introduction. 2. Why Test? 1. Introduction...

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION STRUCTURE CABLING TESTING

ClearGain Tower Mounted Amplifiers A Deployment Guide for Wireless Carriers

New FTTH-based Technologies and Applications A White Paper by the Deployment & Operations Committee

10/40/100 MIGRATION IN DATA CENTERS The Three P s : Path, Polarity and Pins

Fundamentals of Fiber Cable Management. White Paper

Faster Method for Connecting Customers in the Colocation Data Center

An advanced Dark Fiber Monitoring System for Next Generation Optical Access Networks

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano

Fiber Optic Specifications

Joint ITU-T/IEEE Workshop on Next Generation Optical Access Systems. Verizon FiOS FTTP Deployment and NG PON Perspectives

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

Optimux-34, Optimux-25

Splicing and Fiber Assembly Compatibility for Non-Zero Dispersion-Shifted Fiber and Standard Single-Mode Fiber

USE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION INTERNATIONAL ELECTROTECHNICAL COMMISSION

Removing the Mystery from OTDR Measurements. Keith Foord Product Manager Greenlee Communications

Industry solutions: Broad cast

BT and The Developing Optical Access Network Malcolm Campbell BT Design

CADDSTAR V7.0 FEATURES AND FUNCTIONALITY

Optical Fibers Fiber Optic Cables Indoor/Outdoor

BOTDR Measurement Techniques and Brillouin Backscatter Characteristics of Corning Single-Mode Optical Fibers

Next Generation Access Network (in)security

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER

HP Multimode OM3 LC/LC Optical Cables Overview. Models HP 50 m Multimode OM3 LC/LC Optical Cable

Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method

Patch Cords for Data Center Applications

Technical Bulletin. User s Guide To Fiber Optics

Module 13 : Measurements on Fiber Optic Systems

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

ElectroniCast Consultants

Technical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations

WIRELESS /// INTERREACH FUSION FOR BUSINESS INTERREACH FUSION FOR BUSINESS (F4B) WIRELESS SERVICE SIMPLIFIED

Fiber Selection and Standards Guide for Premises Networks

Discontinued. Volition. Fiber Optic Cable. 3Innovation

MINIMIZING PMD IN CABLED FIBERS. Critical for Current and Future Network Applications

Healthcare. Passive Optical LAN Solutions

Cisco ONS Multiservice Transport Platform 7.0

GEPON & GPON Comparison. James Young, Technical Director, APAC

Data Center Market Trends

Designing Fiber Optic Systems David Strachan

A Principled Technologies white paper commissioned by Dell Inc.

WHITE PAPER. Achieving Total Traffic Visibility in Enterprise and Carrier Grade Optical Networks

CWDM: lower cost for more capacity in the short-haul

TR-311 Fiber Infrastructure Management System: Architecture and Requirements

Solutions Focus: IPTV

QuickSpecs. Models HP X131 10G X2 CX4 Transceiver. HP X131 10G X2 Transceivers (SR, LRM, LR, ER and CX4) Overview. HP X131 10G X2 SC LRM Transceiver

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network

As today s evolving data centers

FTTP OSP Design to Maximize Coverage and Upgradeability

TE Connectivity Simplifies Passive Optical Network Deployment for the Telecommunications Industry Association (TIA)

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

Graphical User Interface Capabilities of MATLAB in Centralized Failure Detection System (CFDS)

Transcription:

HOW TO BUILD NETWORKS THAT LAST AND SURVIVE FUTURE REQUIREMENTS

ABSTRACT The optical fiber network infrastructures installed today will typically see four generations of transmission systems over the network s expected lifetime. As recent history has shown, the amount of data traffic these networks will carry will increase dramatically and continuously. In order to cope with this increasing growth, a completely open spectral transmission window from 1260nm to 1625nm for data transmission and up to 1650nm for network monitoring is necessary in all portions of the optical network, including the access portion of FTTH network deployments. Introduction Networks are built to last for decades, and they need to support, without interruption or failure, increasingly heavy traffic at higher bandwidths. Factors that contribute to the network s reliability and longevity, such as the need for good fiber/ cable management and highly reliable connections throughout the network, have been accepted as necessary. In addition to meeting today s needs, operators need to build networks with an eye to future requirements. These have long been standard considerations for long-haul, core and metro networks. What happens when FTTH fiber access networks are built? Today s situation New standards and new technologies in the development of fiber optic cabling and connectivity directly impact operators network considerations. Single-mode optical fibers are designed to operate with wavelengths ranging from 1260 nm up to 1650 nm. Below 1260 nm, the fiber behaves as a multi-mode fiber, while above 1675 nm the fiber glass material starts to absorb the light. Figure 1 shows a typical attenuation curve. Bends in the fiber cause an attenuation increase at longer wavelengths (above 1550 nm). As shown in Figure 2, standard ITU-T G.652D fiber will typically show the following wavelength-dependent attenuation increase when making 10 turns on fiber with a certain diameter. Figure 2 indicates that a minimum bend radius of 20 mm can be accepted for ITU-T G.652D fibers. However, when installing fiber at customer premises, this minimum installation radius is not at all practical. ITU-T G.657 bend insensitive fibers were introduced as a solution. Attenuation (db/km) 0.4 0.2 0 1250 1350 Figure 1: Spectral attenuation of single-mode fibers over different ITU-T transmission bands For G.657 A2 fibers stored with a bend radius of 10 mm, the macrobending loss is about 10 to 20 times lower than that of G.652D fibers with the same bend radius. Also note that for the same O E S C L U 1450 1550 1650 ITU-T has defined the following transmission bands: O-band (Original) 1260 nm to 1360 nm Loss (in db) E-band (Extended) S-band (Short wavelength) C-band (Conventional) L-band (Long wavelength) U-band (Ultra long wavelength) 4 3.6 3.2 2.8 2.4 2 1.6 1.2 0.8 0.4 Spectral macrobending loss of G652D fiber for 10 loops MFD (1310 nm): 8.9µm 9.5µm R Radius 10mm 0 1250 1300 1350 1400 1450 1500 1550 1600 1650 Wavelength (in nm) 1360 nm to 1460 nm 1460 nm to 1530 nm 1530 nm to 1565 nm 1565 nm to 1625 nm 1625 nm to 1675 nm (used for monitoring only) Radius 15mm Radii 20mm Figure 2: Wavelength dependent attenuation caused by macrobending fiber with the same bend radius, the bend loss at 1625 nm will be about 2 to 2.5 times higher than that at 1550 nm.

GPON Up GPON Down RF Video 1260 1290 1330 1480 1500 1550 1625 When ITU-T G.657 bend insensitive fibers were introduced in FTTH roll outs, attention to installation quality and management of fibers and cables seemed to disappear. At the time, it was assumed that using bend insensitive fibers in FTTH PON architectures using wavelengths up to 1550 nm maximum, meant that relaxed patch cord specifications and less fiber management were permissible (Figure 3). Having looser specifications allowed operators to employ crews with lower technical skills in building out their FTTH network. Access and FTTH networks are very large and training the vast number of people required to build them is time consuming and costly. To reduce costs, to save time and meet commitments to various stakeholders, and to match the realities of the competitive landscape, operators have employed installation crews with limited fiber handling skills. Less-skilled crews, however, mean even greater attention must be given to selection of materials and to network architecture. For example, proper fiber splicing requires skill, training and experience. And fullytrained splice technicians are expensive and increasingly rare. A network architecture that minimizes the number of splice locations, concentrating them and increasing their individual splice density, can help reduce costs but must be planned in from the beginning of the network s design. On top of that, many Figure 3: GPON transmission wavelength bands + RF video overlay CO CO FTTH network business cases were calculated to have pay-back in shorter timeframes and focused primarily on initial costs. This resulted in reduced specifications (at 1310 nm and 1550 nm only) of optical fiber cables and optical connectors and reduced attention to installation practices (uncontrolled bends in stored fibers). This trend can soon become a costly issue since the current networks might not be able to deal with systems operating at wavelengths above 1550 nm. Should network deployment decisions be based on financial CAPEX calculations without considering the long-term effects of these decisions and ignoring related OPEX costs? It is tempting to implement savings on the quality of material used, on training installation crews and assuring that specifications meet the real needs, although the relative cost for this quality is typically a very small part of the network s complete total cost of ownership. We should remember that the initial CAPEX of an FTTH deployment consists mainly of civil costs (about 70 percent), cost of actives (about 23 percent) and civil hardware (cables, connectors, closures, distribution frames (about 7 percent) [1]. So the passive equipment, which in general sees long service lives sometimes in the harshest conditions, is a relatively small cost of the overall installation. However, their impact on later OPEX, due to the costs involved in replacing them, can be huge. OPEX costs (assumed to be around 15 percent of CAPEX, but occurring annually) impact the network business case only later on and for that reason seem to be ingnored during fiber access/ftth network builds. [1] Percentages are averages and vary depending on construction types -- buried, aerial, facade, etc. Expected mechanical reliability of fiber lines in various network locations Core Long Haul Trunk Junction Metropolitan Very high reliability Failure probability targets per fiber line < 10-7 over 20 years for core networks Impact of a failure is severe (>1000 customers affected) CO Access network High reliability Splitter cabinet Failure probability targets per fiber line < 10-6 over 20 years for access networks. Impact of a failure is relative severe (less than 64 customers affected) Terminal Wall outlet Drop Distribution network Building distribution box Acceptable reliability Failure probability < 10-5 over 20 years - frequent re-entries expected - smaller fiber bendradii for smaller products - cost effective - impact of a failure is less severe Figure 4: Expected mechanical reliability in various optical networks PAGE 3

XG-PON Up GPON Up GPON Down NG-PON2 Up RF Video XG-PON Down NG-PON2 Down OTDR 1260 1280 1290 1330 1480 1500 1530 1540 1550 1575 1581 1600 1625 1650 Figure 5: Wavelength allocation of various PON transmission protocols Let s consider how use of G.657 bend insensitive fibers impact CAPEX and OPEX. Although optical performance of macrobending improved greatly, the fibers mechanical reliability remained the same as for G.652D fibers. By allowing smaller bend radii, the probability of mechanical failure also increases, without an optical attenuation warning. The careful reader might have seen that in the ITU-T G657 document, a failure probability of 10-5 is considered acceptable for FTTH applications. For long haul networks, a much lower failure probability is requested as one failure could affect the transmission of several thousand customers. As shown in Figure 4, the expected reliability of the fiber lines depends on the type of network. In core, metro and long haul fiber networks, attention has traditionally been paid to the deployed network s long-term reliability. Networks have been built to last for decades, and have had to support, without interruption or failure, increasingly heavy traffic at higher and higher bandwidths. Reduced network quality inevitably leads to increased downtimes. Downtime affecting residential customers was historically not the highest priority for network operators but times, and customer expectations, have changed. One network operator executive described the change of customer contacts at downtimes as an increasing drama effect. Customer calls are much more emotional than in the past as people are almost continuously on line. Fortunately, as pressure and expectations from both business and residential customers has increased, technology has evolved. In recent years, standards and technologies have opened a wider portion of the fiber spectrum to assure that expensively deployed networks are built to last. Requirements for future transmission systems The new NG-PON2 transmission standards that are under discussion at ITU-T allow operators to increase the FTTH networks bandwidth capacities and reduce deployment cost by sharing the same fiber with more connected customers or sharing networks with multiple operators. The new NG- PON2 standards, using transmission wavelengths from 1260 to 1625 nm, employ more of the same fiber deployed and allow seamless overlays of new services to existing GPON networks (Figure 5). With both a wider spectrum, and a less forgiving customer base, are we still willing to introduce components with reduced specifications today into future-generation access networks? The NG-PON2 downstream channels will operate in the wavelength band between 1600 nm and 1625 nm. These are the transmission wavelengths most sensitive for bending of the fiber (Figure 6). Attenuation increase with one turn of ITU-T G.657A2 fiber with radius R 1.0 R = 7.5 mm R XG-PON Up GPON Up GPON Down NG-PON2 Up RF Video XG-PON Down NG-PON2 Down OTDR Attenuation (db) 0.5 0.0 R = 10 mm R = 15 mm 1260 1280 1290 1330 1480 1500 1530 1540 1550 1575 1581 1600 1625 1650 Figure 6: Macrobending attenuation for ITU-T G.657 A2 fiber

Surprisingly enough, the current ITU-T and IEC performance standards for cables and connectors do not always reflect the requirements for these future transmission wavelengths (Table 1). For future-proof networks, all network components should be specified for use at 1625 nm. Standardization bodies like ITU-T and IEC will pay attention to this in the revisions of the standards for cables and connectors. In the past, operators replaced connectivity components in the core network when they started to use longer wavelengths in order to increase the capacity of their fiber builds. For FTTH networks the impact of such rework would obviously be multiplied as the number of connectivity points is huge compared to those in core networks. IEC and ITU performance standards for various network components Network component 1310 nm 1550 nm 1625 nm Fibers ITU-T G.65x series IEC 60793 series Cables none IEC 60794 series Splices Connectors Splitters IEC 61753-131 series ITU-T L.12 none IEC 61753-021 series ITU-T L.36 IEC 61753-031 series ITU-T L.37 WDM some IEC 61753-08x series Fiber Management Systems Enclosures IEC 61753-101 series ITU-T L.51 IEC 61753-111 series ITU-T L.13 Table 1: IEC and ITU performance standards for various network components Conclusion As pressure and expectations from both business and residential customers has increased, technology has to evolve. In recent years, standards and technologies have opened a wider portion of the fiber transmission spectrum to assure that expensively deployed networks are built to last, even when new transmission equipment or systems are added to the line. Factors that contribute to reliability and longevity, such as the need for reliable connections and good fiber/ cable management systems throughout the network, are necessary. To survive and grow, operators need to build networks with an eye to future requirements change will happen, that is certain. What form the change will take is less clear, but future use of wavelengths up to 1625 nm is a certainty. Lessons from the past training crews to handle fiber properly, using solutions supporting correct cable management, using connectors with the right performance specification provide both short- and long-term benefits to operators and customers alike. PAGE 5

SAM LEEMAN Sam Leeman is Senior Manager of Application Engineering for EMEA at TE Connectivity. Sam leads the EMEA team of field technical engineers supporting customer applications across TE s full spectrum of industryleading FTTH, structured cabling, DAS, central office, and outside plant solutions. Sam Leeman joined Raychem in 1998 in R&D as product development engineer. Over the following 16 years, he held a variety of positions in project management, product management and business development for both the Enterprise and Telecom Divisions but has spent most his career working in the field of FTTH Network Solutions. DANIEL DAEMS Since 1988, Daniel Daems has developed optical fiber management systems for outside plant applications. Currently Senior R&D Manager of the Fiber Optic Technology and Standards Department at TE Connectivity in Belgium, Daniel is Chairman of IEC SC86B (Fiber optic interconnecting devices and passive components) and Convener of the Cenelec (European standards) TC86BXA WG2 for fiber optic enclosures. te.com TE Connectivity, TE connectivity (logo) and Every Connection Counts are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity s obligations shall only be as set forth in TE Connectivity s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. 2015 TE Connectivity Ltd. family of companies All Rights Reserved. 319934.1 01/15 Revision WHITE PAPER TE Connectivity Broadband Network Solutions - EMEA Diestsesteenweg 692 3010 Kessel-Lo, Belgium Tel 32-16 351 011 www.te.com/bns Tyco Electronics Raychem bvba, a TE connectivity company.