Although excellent sensitivity

Similar documents
Protocol for the safe administration of iodinated contrast media in diagnostic radiology

According to its FDA-approved product labeling (PI), Visipaque is indicated for the following (emphasis in original; footnotes omitted):

Nefropatia de Contraste

Update on Contrast Material Use in Children Jonathan R. Dillman, M.D.

8. Strategies in Patients at Risk for Allergic Reactions to IV Contrast for CT

Imaging of Thoracic Endovascular Stent-Grafts

Imaging of Acute Stroke. Noam Eshkar, M.D New Jersey Neuroscience Institute JFK Medical Center Edison Radiology Group

IV Contrast Extravasation PQI Project Feed-Back Document from the Society of Abdominal Radiology & American College of Radiology

Main Effect of Screening for Coronary Artery Disease Using CT

The Principles of Contrast Mammography

Court Rules that GE Healthcare Engaged in False Advertising Campaign against Bracco Diagnostics

Power Injectors for Diagnostic Imaging

MYOCARDIAL PERFUSION COMPUTED TOMOGRAPHY PhD course in Medical Imaging. Anne Günther Department of Radiology OUS Rikshospitalet

List of Publications. Evaluation of stents and grafts. de Graaf FR, Schuijf JD. EuroIntervention 2010; 6 Suppl G: G48-56.

ASGE Technology Status Evaluation Report: radiographic contrast media used in ERCP

The Official Journal of the International Andreas Gruentzig Society SPECIAL SUPPLEMENT

HYPERTENSION ASSOCIATED WITH RENAL DISEASES

MANAGEMENT OF DIABETIC PATIENTS IN RADIOLGY. Edition 2

Renovascular Hypertension

Update in Contrast Induced Nephropathy

What are contrast materials and how do they work? Contrast materials enter the body in one of three ways. They can be:

ECG may be indicated for patients with cardiovascular risk factors

Cardiac Assessment for Renal Transplantation: Pre-Operative Clearance is Only the Tip of the Iceberg

First floor, Main Hospital North Services provided 24/7 365 days per year

Contrast-Induced Nephropathy: Pathophysiology and Preventive Strategies

Nierfunctiemeting en follow-up van chronisch nierlijden

IV solutions may be given either as a bolus dose or infused slowly through a vein into the plasma at a constant or zero-order rate.

Pediatric Hospitals Bring Low-dose CT to the Middle East

Low-gradient severe aortic stenosis with normal LVEF: A disturbing clinical entity

La prevenzione della nefropatia da contrasto nel paziente cardiologico. Carlo Guastoni U.O. Nefrologia Ospedale Civile di Legnano

CT scans and IV contrast (radiographic iodinated contrast) utilization in adults

RADIOLOGY SERVICES. By Dr Lim Eng Kok 1

STONY BROOK UNIVERSITY HOSPITAL VASCULAR CENTER CREDENTIALING POLICY

RADIOLOGY HOUSE STAFF MANUAL

Clinical Research Intracoronary Stenting with Crushing in Coronary Artery Bifurcation Lesions: Initial Results and Medium-Term Follow Up

Cilostazol versus Clopidogrel after Coronary Stenting

CORONARY ARTERY BYPASS GRAFTS, STENTS, AND EXTRACORONARY CARDIAC DZ. Charles White MD

Steven J. Yakubov, MD FACC For the CoreValve US Clinical Investigators

Acute abdominal pain in the elderly patient: Impact of early MDCT examination on diagnosis and management

CT Angiography (CTA) What is CT Angiography?

Renal Blood Flow GFR. Glomerulus Fluid Flow and Forces. Renal Blood Flow (cont d)

YUCK YUM. The Black and White of Contrast Radiography. Contrast Radiography. Contrast Radiography Today. Definition of Contrast.

Stephen P. Wood, ACNP-BC, MS

CT THORAX, ABDOMEN & PELVIS PREPARATION AT HOME

State-of-the-Art Technology in Cardiac CT

CONTRAST MEDIA TUTORIAL CT CONTRAST AGENTS

KIDNEY FUNCTION RELATION TO SIZE OF THE TUMOR IN RENAL CELL CANCINOMA

Non-invasive functional testing in 2014

ESUR GUIDELINE*: GADOLINIUM BASED CONTRAST MEDIA AND NEPHROGENIC SYSTEMIC FIBROSIS (17 July 2007) Overview

UC San Diego Health System Intravenous Contrast Media Guidelines Adult Approved by P&T Committee 6/18/2014

Pharmacologic Stress Agents: Protocol and Safety

Ultrasound in Vascular Surgery. Torbjørn Dahl

The sensitive marker for glomerular filtration rate (GFR) Estimation of GFR from Serum Cystatin C:

Series 1 Case Studies Adverse Events that Represent Unanticipated Problems: Reporting Required

Cardiac Rehabilitation An Underutilized Class I Treatment for Cardiovascular Disease

How To Improve Your Ct Image Quality

Questions and Answers for Health Care Providers: Renal Dosing and Administration Recommendations for Peramivir IV

Abdominal CT Perfusion: Effects of Breath Control Technique

Patient Prep Information

Quantitative Imaging In Clinical Trials Using PET/CT: Update

Low-dose CT for Pulmonary Embolism

Computed Tomography (CT) - Sinuses

What is creatinine? The kidneys maintain the blood creatinine in a normal range. Creatinine has been found to be a fairly reliable indicator of kidney

PHARMACOLOGICAL Stroke Prevention in Atrial Fibrillation STROKE RISK ASSESSMENT SCORES Vs. BLEEDING RISK ASSESSMENT SCORES.

Cardiac catheterization and complications: initial experience

Multi-slice Helical CT Scanning of the Chest

Hydration Protocol for Cisplatin Chemotherapy

Duplication Images in Vascular Sonography

University College Hospital. Contrast agent for radiotherapy CT (computed tomography) scans. Radiotherapy Department Patient information series

Chest 1: Pulmonary Nodule Follow-up: Low-Dose Helical CT (Unenhanced) (Non-metastatic) Gantry Rotation Time. mas (Reg-Lg) 40-80

CHAPTER 4 QUALITY ASSURANCE AND TEST VALIDATION

CMS Manual System Pub Medicare National Coverage Determinations

Package nephro. February 23, 2015

Measure #257 (NQF 1519): Statin Therapy at Discharge after Lower Extremity Bypass (LEB) National Quality Strategy Domain: Effective Clinical Care

在 急 症 部 進 行 電 腦 掃 描 造 影 時, 使 用 平 板 電 腦 去 簽 署 動 畫 輔 助 同 意 書 的 效 果

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

Copyright March 1, 2016 by AAPM. All rights reserved.

Tunneled Hemodialysis Catheters: Placement and complications

Estimated GFR Based on Creatinine and Cystatin C

Computed Tomography (CT) - Chest

POAC CLINICAL GUIDELINE

Perioperative Cardiac Evaluation

Questions and Answers

Procedures/risks: Radiology (CT, DXA, MRI, ultrasound, X-ray)

Rb 82 Cardiac PET Scanning Protocols and Dosimetry. Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals

Critical Appraisal of Article on Therapy

Atherosclerosis of the aorta. Artur Evangelista

CARDIAC SURGERY INTRAVENOUS INSULIN PROTOCOL PHYSICIAN ORDERS INDICATIONS EXCLUSIONS. Insulin allergy

Positron Emission Tomography - For Patients

All patients presenting to the Emergency Department with symptoms suggestive of

FFR CT : Clinical studies

Coronary angiogram : An author view Patwary MSR

CTA OF THE EXTRACORONARY HEART

What You Should Know About Cerebral Aneurysms

X-Rays Benefits and Risks. Techniques that use x-rays

Standards of practice of computed tomography coronary angiography (CTCA) in adult patients

GE Healthcare. Revolution EVO. More than just high tech. Higher purpose.

Homeostatic Model Assessment (HOMA)

ΠΟΙΟ ΑΝΤΙΠΗΚΤΙΚΟ ΓΙΑ ΤΟΝ ΑΣΘΕΝΗ ΜΟΥ? ΚΛΙΝΙΚΑ ΠΑΡΑΔΕΙΓΜΑΤΑ. Σωκράτης Παστρωμάς Καρδιολόγος Νοσοκομείο Ερρίκος Ντυνάν

Use of lead shielding for adult chest CT. patient & radiographer experiences

Transcription:

RAD Magazine, October 8 Which Contrast Agent For Coronary CT Angiography? Address for correspondence: Dr. Francesca Pugliese MRC - Clinical Sciences Centre - PET Cardiology E-mail: francesca.pugliese@libero.it francesca.pugliese@imperial.ac.uk Dr. Francesca Pugliese MRC - Clinical Sciences Centre Hammersmith Campus London, UK and Radiology Royal Brompton Hospital London, UK Introduction Although excellent sensitivity has been reported for computed tomography angiography (CTA) in the detection of significant coronary artery stenoses (1, 2), a prerequisite for successful and robust coronary CTA is prominent vascular enhancement. The type and iodine concentration of the contrast agent used in coronary CTA have assumed increasing importance because the attenuation that can be achieved within the vessel lumen greatly affects the diagnostic yield (3, 4). These considerations are particularly important for imaging the coronary arteries because of the small caliber and tortuous anatomy of these vessels, and because of the decreased blood flow in the presence of stenosis or obstruction. Contrast enhancement in coronary CTA The pattern of enhancement in coronary arteries can be described by plotting the attenuation values within the vessel against time after intravascular injection of contrast. This curve is also called bolus geometry. The ideal condition for the enhancement curve is a rectangular profile that overlaps the acquisition window exactly. In practice, the enhancement curve has an upslope, a smooth peak resembling a plateau and a wash-out portion (Figure 1). Being aware of the attenuation changes in a vascular territory (and how to modify them) is not trivial because CTA is based on the acquisition of data strictly synchronized with the arterial passage of contrast agent.

How to optimize contrast enhancement in coronary CTA The minimum intracoronary attenuation to be achieved when performing coronary CTA is 250- HU at the lowest (5). Coronary arteries have a small diameter (2-5 mm) and blood flow can be decreased in Figure 1. Attenuation-time curves after contrast injection. A: in ideal settings, the enhancement curve (dotted line, 1) has a rectangular shape and overlaps exactly the CT acquisition window (light grey rectangle). The real enhancement curve (continuous line, 2) has a steep upslope, a rounded peak and a wash-out downslope. In practice, portions of all the three enhancement phases are imaged. PME = peak of maximum enhancement. tpme = time to peak of maximum enhancement. B: increasing the contrast volume (ml), injection rate (ml/s) and iodine concentration ([I]) increases the PME. The increase in contrast volume increases the tpme; the increase in injection rate decreases the tpme; the tpme is not affected by the iodine concentration. the presence of a stenosis or obstruction. Roughly, good coronary enhancement requires iodine administration rates of 1.6-2 g/s. An increase in contrast volume increases absolute intravascular attenuation but delays the peak of maximum enhancement (Figure 1B). An increase in the iodine concentration yields proportionally higher intravascular attenuation (6), and so does an increase in the injection rate. However, whereas an increase in injection rate decreases the time to the peak of maximum enhancement, the latter remains unaffected by concentration changes (Figure 1B). It can be argued that the iodine administration rate can be modified more easily by changing the injection rate than by changing the contrast iodine concentration. However, the injection rates that are feasible in routine clinical practice are 4 5 ml/sec. The use of higher injection rates would require larger needles, larger veins, more time for setting the intravenous line and could potentially increase the risk of contrast extravasation. Increasing the iodine concentration is always feasible in any condition. Thus the use of high-concentration (-400 mgi/ ml) contrast agents is preferred over lowconcentration ones.

The influx of contrast of very high concentration may cause high-density artefacts. A saline bolus following the contrast bolus may compensate for this. Moreover, contrast viscosity increases with iodine concentration and decreases with rising temperatures. Hence high concentration contrast agents should be administered after appropriate heating at 38 C. For the synchronization of the CT scan with the peak of maximum enhancement Contrast concentration Several studies have discussed the role of contrast with high iodine concentration for coronary CTA (5, 7-9). In a study comparing several contrast agents with differing iodine concentrations (iohexol mgi/ml, iodixanol 320 mgi/ml, iohexol mgi/ml, iomeprol mgi/ml, and iomeprol 400 mgi/ml), it was shown that significantly higher vascular attenuation was achieved with the highest iodine Figure 2. Comparison of blood attenuation after injection of contrast agents with different iodine concentration, both injected at 4ml/sec. A: attenuation obtained with an iodine concentration of 400 mgi/ml, and B: attenuation obtained with an iodine concentration of 320 mgi/ml. Notice the differences in attenuation at the level of the aorta, left main and left anterior descending arteries. within the coronary arteries (Figure 1), protocols such as bolus tracking (smart prep) or test bolus are routinely used. concentration, and significantly lower attenuation was achieved with the lowest iodine concentration (8) (Figure 2). Another study (7) aimed at further defining the benefits of contrast agent with high iodine concentration by comparing the attenuation achieved in the coronary arter-

ies and great vessels of the thorax after administration of 2 contrast agents with high iodine concentration (iopromide 370 and iomeprol 400). With all other injection variables (volume, injection rate) and scan parameters (kv, ma) kept constant, significantly higher attenuation was found in all vessels with the contrast agent with the highest iodine concentration (400 mgi/ml). Contrast induced nephropathy (CIN) and contrast agent safety Contrast induced nephropathy (CIN) is generally defined as an increase in serum creatinine of more than 25%, or 44 μmol/l [0.5 mg/dl] within 3 days after the intravascular administration of a contrast agent (10). The highest risk for CIN is seen in patients with preexisting kidney disease (serum creatinine >132 μmol/l [1.5 mg/dl], glomerular filtration rate <60 ml/min), particularly when due to diabetic nephropathy (10, 11). Diabetes mellitus without renal impairment is not considered a risk factor (10). The route of contrast administration is also important. Contrast agents seem less nephrotoxic when administered intravenously than when given intraarterially into the renal arteries or the aorta proximal to the origin of the renal arteries (12). A meta-analysis of comparative trials (17) showed that high-osmolar contrast agents should be avoided in patients at increased risk of CIN. The question remains as to whether the other available contrast agents, several low-osmolar and one isoosmolar, differ in terms of nephrotoxicity. Several nonionic monomers (iohexol, iomeprol, iopamidol, iopromide, ioversol, iobiditrol), one ionic dimer (ioxaglate), and one nonionic dimer (iodixanol) (Table 1) are available for intravascular use. In 3, the results of a randomized trial by Aspelin et al. (11) (NEPHRIC study) suggested less CIN with use of the isoosmolar nonionic dimer (iodixanol) than with nonionic monomers in 129 patients with moderate chronic kidney disease and diabetes mellitus receiving an intraarterial contrast injection during coronary or aorto-femoral angiography. However other studies (18-21) have not confirmed the results of the NEPHRIC study. Whereas controversy may exist about differences in nephrotoxicity between isoosmolar and low-osmolar contrast agents following their intraarterial administration (22), there is no clear advantage of using the nonionic dimer for intravenous injection. Thomsen et al. (20) reported 7% CIN after intravenous injection of 40 gi of the iso-osmolar iodixanol and 0% CIN after the low-osmolar iomeron in patients with reduced kidney function (P<0.05). Barrett et al. (23) showed a 2.6% CIN rate after intravenous injection of iodixanol

Table 1. Properties of low- and iso-osmolar contrast agents [modified from (26)] Generic name Ioxaglate Iohexol Iopamidol Ioversol Iopromide Iobitridol Iomeprol Iodixanol Type, ionicity Ionic (dimer) Iso-osmol. (dimer) Trade name Hexabrix Omnipaque Manufacturer Guerbet (licensed to Tyco Healthcare/Mallinckrodt) GE Healthcare Biosciences/Amersham Health Iodine Concentration (mg/ml) 160 320 180 240 Osmolality (mosm/kg H2O) 295 370 600 680 410 Omnitrast Schering 250 520 Omnigraf Juste Isovue Bracco Diagnostics 150 Iopamiro Jopamiro Niopam Solutrast Optiray Ultravist Bracco Intl Bracco Intl Bracco UK Bracco Altana-Pharma Tyco Healthcare/ Mallinckrodt Schering Berlex 240 370 160 240 320 150 180 240 370 400 Xenetix Guerbet 250 Iomeron Bracco Intl 150 250 400 Visipaque GE Healthcare Biosciences/Amersham Health 150 270 320 640 780-340 412-438 480 616-680 730 796-832 355 380 502 550 630 695 720 790 340 390 420 480-500 610-620 730 774-780 880 585 695 915 301 362 440 521-609 620 730 290 290 290

and 0% after injection of iopamidol in a randomized, multicenter trial (IMPACT). These results were similar to those of a previous study by Carraro et al. (24) in which no difference was found between the iso-osmolar iodixanol and the low-osmolar iopromide in patients with chronic kidney disease. A recent study by Nguyen et al. (25) randomized 117 patients with decreased renal function undergoing contrast-enhanced CT to receive either iodixanol (61 patients) or iopromide (56 patients). Serum creatinine levels were measured one, two, and three days after the exam, and then again after 30 and 90 days. This study found that after one day serum creatinine levels were lower with iodixanol than with iopromide. However, no patients in either group showed contrastrelated adverse events at the 30- or 90- day follow-up. Conclusion Good coronary enhancement is mandatory in order to perform successful coronary CTA. The minimum intracoronary attenuation to be achieved is 250- HU at the lowest. Coronary arteries are small vessels with a tortuous anatomy. Moreover, coronary blood flow can be decreased in the presence of stenosis or obstruction. In order to optimize coronary enhancement, iodine administration rates of 1.6-2 g/s should be used. Contrast injection rate and concentration must be chosen accordingly. The injection rates that are feasible in clinical routine are 4 5 ml/sec. The use of higher injection rates would require larger needles, larger veins and could potentially increase the risk of contrast extravasation. Conversely, the use of high-concentration (-400 mgi/ ml) contrast agents is always feasible and increases coronary enhancement proportionally. High-concentration contrast agents are low-osmolar nonionic monomers. For intravenous injection, these contrast agents can be considered as safe as iso-osmolar nonionic dimers.

References 1. Pugliese F, Mollet NR, Hunink MG, et al. Diagnostic performance of coronary CT angiography by using different generations of multisection scanners: single-center experience. Radiology 8; 246:384-393. 2. Vanhoenacker PK, Heijenbrok-Kal MH, Van Heste R, et al. Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: meta-analysis. Radiology 7; 244:419-428. 3. Bae KT, Heiken JP, Brink JA. Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model. Radiology 1998; 207:647-655. 4. Fleischmann D, Rubin GD, Bankier AA, Hittmair K. Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography. Radiology 0; 214:363-371. 5. Becker CR, Hong C, Knez A, et al. Optimal contrast application for cardiac 4-detectorrow computed tomography. Invest Radiol 3; 38:690-694. 6. Fleischmann D. Use of high concentration contrast media: principles and rationalevascular district. Eur J Radiol 3; 45 Suppl 1:S88-93. 7. Cademartiri F, de Monye C, Pugliese F, et al. High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400. Invest Radiol 6; 41:349-353. 8. Cademartiri F, Mollet NR, van der Lugt A, et al. Intravenous contrast material administration at helical 16-detector row CT coronary angiography: effect of iodine concentration on vascular attenuation. Radiology 5; 236:661-665. 9. Rist C, Nikolaou K, Kirchin MA, et al. Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing and 400 milligrams of iodine per milliliter. Invest Radiol 6; 41:460-467. 10. Thomsen HS, Morcos SK. Contrast media and the kidney: European Society of Urogenital Radiology (ESUR) guidelines. Br J Radiol 3; 76:513-518. 11. Aspelin P, Aubry P, Fransson SG, Strasser R, Willenbrock R, Berg KJ. Nephrotoxic effects in high-risk patients undergoing angiography. N Engl J Med 3; 348:491-499. 12. Katzberg RW, Barrett BJ. Risk of iodinated contrast material--induced nephropathy with intravenous administration. Radiology 7; 243:622-628. 13. Thomsen HS, Morcos SK. In which patients should serum creatinine be measured before iodinated contrast medium administration? Eur Radiol 5; 15:749-754. 14. Cockcroft DW, Gault MH. Prediction of creatinine clearance from serum creatinine. Nephron 1976; 16:31-41. 15. Bostom AG, Kronenberg F, Ritz E. Predictive performance of renal function equations for patients with chronic kidney disease and normal serum creatinine levels. J Am Soc Nephrol 2; 13:2140-2144. 16. Blaufox MD, Aurell M, Bubeck B, et al. Report of the Radionuclides in Nephrourology Committee on renal clearance. J Nucl Med 1996; 37:1883-1890.

17. Barrett BJ, Carlisle EJ. Metaanalysis of the relative nephrotoxicity of high- and low-osmolality iodinated contrast media. Radiology 1993; 188:171-178. 18. Liss P, Persson PB, Hansell P, Lagerqvist B. Renal failure in 57 925 patients undergoing coronary procedures using iso-osmolar or low-osmolar contrast media. Kidney Int 6; 70:1811-1817. 19. Solomon RJ, Natarajan MK, Doucet S, et al. Cardiac Angiography in Renally Impaired Patients (CARE) study: a randomized doubleblind trial of contrast-induced nephropathy in patients with chronic kidney disease. Circulation 7; 115:3189-3196. 20. Thomsen HS, Morcos SK, Erley CM, et al. The ACTIVE Trial: comparison of the effects on renal function of iomeprol-400 and iodixanol-320 in patients with chronic kidney disease undergoing abdominal computed tomography. Invest Radiol 8; 43:170-178. 21. Barrett BJ, Katzberg RW, Thomsen HS, et al. Contrast-induced nephropathy in patients with chronic kidney disease undergoing computed tomography: a double-blind comparison of iodixanol and iopamidol. Invest Radiol 6; 41:815-821. 22. Thomsen HS, Morcos SK, Barrett BJ. Contrastinduced nephropathy: the wheel has turned 360 degrees. Acta Radiol 8; 49:646-657. 23. Barrett BJ, Parfrey PS. Clinical practice. Preventing nephropathy induced by contrast medium. N Engl J Med 6; 354:379-386. 24. Carraro M, Malalan F, Antonione R, et al. Effects of a dimeric vs a monomeric nonionic contrast medium on renal function in patients with mild to moderate renal insufficiency: a double-blind, randomized clinical trial. Eur Radiol 1998; 8:144-147. 25. Nguyen SA, Suranyi P, Ravenel JG, et al. Isoosmolality versus low-osmolality iodinated contrast medium at intravenous contrastenhanced CT: effect on kidney function. Radiology 8; 248:97-105. 26. Davidson C, Stacul F, McCullough PA, et al. Contrast medium use. Am J Cardiol 6; 98:42K-58K.