True RMS Bench Multimeter 5492B

Similar documents
DC Electronic Loads 8500 series

1.44 kw Programmable DC Power Supplies XLN Series

Multi-Range Programmable DC Power Supplies 9115 Series

High Power Programmable DC Power Supplies PVS Series

Multi-Range Programmable DC Power Supplies 9115 Series

No.1. Digital Multimeter RIGOL TECHNOLOGIES, INC.

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

2000 6½-Digit Multimeter

Agilent 4338B Milliohm Meter

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Fluke 2638A Hydra Series III Data Acquisition System/ Digital Multimeter

Panel Meters and Controllers Modular Panel Meter Type EDM 35

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

PICOTEST. M3500A 6.5 Digit Digital Multimeter. User s Manual

Physical Specifications (Custom design available.)

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

R&S ZNBT8 Vector Network Analyzer Specifications

U1602A Handheld Oscilloscopes, 20 MHz

Mobile Communications DC Sources W

AutoRanging Digital MultiMeter

DCS Series 1 kw, 1.2 kw, & 3 kw

5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument

Dual Display Digital Multimeter

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Fluke 3000 FC Series Test Tools Technical Data

User's Guide. True RMS Industrial Multimeter

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

1. SAFETY INFORMATION

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Impedance 50 (75 connectors via adapters)

Voltech DC1000. Precision DC Bias Current Source

High Voltage Power Supplies

DP800. Programmable Linear DC Power Supply RIGOL TECHNOLOGIES, INC.

How To Use A Cdm250 Digital Multimeter

/ LCR HiTESTER Components measuring instruments

Agilent 4339B/4349B High Resistance Meters

Agilent E5100A Network Analyzer

Rack mounted telephone- and leased line modem for industrial applications

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

khz to 2.7 GHz Spectrum Analyzer

PERF10 Rubidium Atomic Clock

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

R&S SMZ Frequency Multiplier Specifications

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

FFT Spectrum Analyzers

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

R&S ZNC Vector Network Analyzer Specifications

SL Series AC and DC Electronic Loads

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Temperature & Humidity SMS Alert Controller

R&S ZVA Vector Network Analyzer Specifications

Energy Management Energy Meter Type EM23 DIN

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

LLM 6 th Edition Low Level Measurements Handbook Precision DC Current, Voltage, and Resistance Measurements

Power Meter Series 700

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

Manual Ranging MultiMeter

Digital Clamp-on DMMs with uncompromising performance

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Keysight Technologies AC6800 Series Basic AC Power Sources. Data Sheet

T Substation Maintenance and Commissioning Test Equipment

Considerations When Specifying a DC Power Supply

Agilent 8904A Multifunction Synthesizer dc to 600 khz

PowerGem Pro Uninterruptible Power Supply

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Integrating Sound Level Meter and Datalogger

Dynatek 6080RS multimeter

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Telephone- and leased line modem for industrial applications TD-36

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Model UT33A: OPERATING MANUAL Table of Contents (1)

FREJA 300 Relay Testing System

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

MODEL 1211 CURRENT PREAMPLEFIER

Power Electronics Testings

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Electronic Control Devices The European Product Catalogue 2007

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

KONSTANTER SPL / SPL Programmable Electronic Load

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

10 Multimeter. Users Manual

Current Monitoring Kit QUICK START GUIDE

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

Agilent E3633A and E3634A DC Power Supplies

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

How To Use An Hm804X Series Of Power Supplies

Uninterruptible Power Supply

THURLBY THANDAR INSTRUMENTS. Model 1906 COMPUTING MULTIMETER INSTRUCTION MANUAL

Ground Resistance Clamp On Tester

User's Guide. Digital Sound Level Meter. Model

Arbitrary/Function Generators AFG3000C Series Datasheet

Model UT58A/B/C: OPERATING MANUAL

Digital Storage Oscilloscopes Models 2540B, 2542B, 2540B-GEN, 2542B-GEN

Transcription:

Data Sheet 5492B The B&K Precision model 5492B is a versatile 5½-digit, 120,000-count bench multimeter suitable for applications in education, service repair, and manufacturing. The instrument enhances your productivity with built-in math functions and USB connectivity. Rel, Max/Min, dbm, db, %, and Hold functions provide educators with a convenient tool to teach basic math concepts. Additionally, the 5492B offers powerful features not commonly found in other 5½- digit DMMs such as advanced triggering, buffer storage operation, and a GPIB interface option. Features & benefits The 5492B measures volts and amps with great accuracy and stability, with basic VDC accuracy of 0.01%. The meter is also capable of measuring frequency, period, resistance, continuity, and performing diode tests. s can be taken at a maximum rate of 57 readings/sec and stored to an internal 512-byte buffer for post acquisition statistical analysis. 5½-digit, 120,000-count display resolution 0.01% basic VDC accuracy Advanced triggering options such as external, Two and four-wire resistance measurement up AC voltage and AC current measurement over bus and event trigger to 120 MΩ wide frequency range (ACV 100 khz/aci 10 The 5492B was designed for cost-conscious users requiring an accurate meter with a broad range of features offered at a value price. Increase Productivity with PC Connectivity khz) AC (RMS) and DC current measurements up to 12 A Limit mode for Pass/Fail testing Save/recall up to 10 instrument settings The 5492B is programmable via USB, RS232, and GPIB (5492BGPIB only) interface using industry standard SCPI commands. Users can remotely control and configure the instrument from a PC and retrieve measurement results for further analysis. The multimeter can also be remotely controlled using application software (via USB & RS232), which supports front panel emulation and data logging of measurement results. Technical data subject to change B&K Precision Corp. 2014 Built-in math functions: Rel, Max/Min, dbm, db, %, Hold, Compare w w w.bk prec ision.c om CATI (1000 V)/CATII (300 V) protection USB (Virtual Com) and RS232 interface SCPI compatible

Versatile tools Easy operation Limit Operation The limit operation lets you set and control the values that determine a HI / IN / LO status of subsequent measurements. The meter can be configured to emit an audible alarm when readings are outside of the configured limit. Front panel Input banana terminals Bright VFD display Advanced Triggering A variety of advanced trigger options are available: Manual Trigger via a front panel button press, Bus Trigger sending a *TRG command via PC interface, External Trigger using the EXT TRIG input terminal on the rear panel. Additionally, a trigger delay can be programmed after an event detection, and a VM Comp output is available to indicate the instrument s completion of a present measurement. Fast Buffering with Built-in Statistics The 5492B provides an internal buffer capable of storing up to 512 readings. Buffer storage operation can be enabled via front panel or remote command. The buffer fills up with the requested number of readings at a rate of up to 57 readings/sec and then stops. The instrument automatically calculates statistical information based on the stored readings such as minimum, maximum, or average reading, and standard deviation, which can then be retrieved along with the readings via the front panel or remote command. Power button Interface keypad Rear panel Serial number label External Trigger BNC input terminal RS-232 (Serial) interface USB interface Power line fuse holder 2 VM Comp (Voltmeter complete) BNC output terminal ma Fuse socket GPIB (IEEE-488) interface (model 5492BGPIB) Chassis ground screw terminal w w w.bk prec ision.c om

Specifications Specifications are based on the following conditions: One year calibration cycle Operating temperature between 18 C to 28 C expressed as: ± (% of reading + % of range) after 30 minutes warm-up and valid for 10 PLC (Slow) Temperature coefficient: add ± [0.1% (applicable accuracy)/ C] for 0 C to 18 C and 28 C to 40 C Relative humidity: Up to 80% RH for 0 C to 28 C (75% RH for 10 MΩ and above ranges for resistance measurement), up to 70% RH for 28 C to 40 C DC Voltage Typical Input Impedance 120.000 mv 1 µv 119.999 0.02+0.008 (1) >10 GΩ 1.20000 V 10 µv 1.19999 0.01+0.004 (1) >10 GΩ 12.0000 V 100 µv 11.9999 0.01+0.004 >10 GΩ 120.000 V 1 mv 119.999 0.01+0.004 10 MΩ ±1% 1000.00 V 10 mv 1010.00 (2) 0.01+0.004 10 MΩ ±1% (1) under REL status (2) 1% overrange (1010 V) is readable at 1000 V range Input protection: 1000 V AC Voltage (True RMS, AC coupled) Measurement method: AC coupled true RMS, measuring the AC component only Maximum Crest factor: 3.0 at full scale Input impedance: 1 MΩ ± 2% in parallel with capacitance <100 pf Input protection: 750 Vrms, 500 Vdc (1) 10-20 Hz 20-50 Hz 50-20 khz 20-50 khz 50-100 khz 120.000 mv 1 µv 119,999 1.50+0.100 0.50+0.100 0.10+0.100 0.30+0.150 1.0+0.150 1.20000 V 10 µv 1.19999 1.50+0.100 0.50+0.100 0.10+0.100 0.30+0.150 1.0+0.100 12.0000 V 100 µv 11.9999 1.50+0.100 0.50+0.100 0.10+0.100 0.30+0.150 1.0+0.100 120.000 V 1 mv 119.999 1.50+0.100 0.50+0.100 0.10+0.100 0.30+0.150 1.0+0.100 750.00 V 10 mv 757.50 (3) 1.50+0.100 0.50+0.100 0.10+0.100 0.30+0.150 (2) 1.0+0.100 (1) (1) Specifications are for sine wave inputs >5% of range (2) 3 10 7 Volt-Hz for 750 V range (3) 1% overrange (757.5V) is readable at 750 V range DC Current Burden Voltage (1) & Shunt Resistor 12.0000 ma 0.1 µa 11.9999 0.05+0.008 (2) <0.15 V / 10.1 Ω 120.000 ma 1 µa 119.999 0.05+0.004 (2) <1.5 V / 10.1 Ω 1.20000 A 10 µa 1.19999 0.10+0.004 <0.3 V / 0.1 Ω 12.0000 A (3) 100 µa 11.9999 0.25+0.004 <0.15 V / 10 mω (1) Typical voltage across the input terminals at full scale reading (2) Use REL function (3) In 12 A range, >10~12 ADC is readable for 20 seconds maximum Input protection: Externally accessible 2A / 250V fuse protecting the low input current terminal (LO). Internally accessible 20A / 250V fuse protecting the high current input terminal (10A) 3 www.bk precision.com

Specifications (cont.) AC Current (True RMS, AC Coupled) Burden Voltage (1) & Shunt Resistor (3) 10-20 Hz 20-50 Hz 50-2 khz 2-20 khz 12.0000 ma 0.1 µa 11.9999 <0.15 V / 10.1 Ω 1.0+0.080 0.50+0.080 0.25+0.080 2.0+0.080 1.20000 A 10 µa 1.19999 <0.3 V / 0.1 Ω 1.0+0.080 0.50+0.080 0.25+0.080 2.0+0.080 12.0000 A (2) 100 µa 11.9999 <0.15 V / 10 mω 1.0+0.080 0.50+0.080 0.25+0.080 2.0+0.080 (1) Typical voltage across the input terminals at full scale reading (2) In 12 A range,>10-12 A AC is readable for 20 seconds maximum (3) Specifications are for sine wave inputs >5% of range Measurement method: AC coupled true RMS, measuring the AC component only Input protection: Externally accessible 2 A / 250 V fuse protecting the low input current terminal (LO). Internally accessible 20 A / 250 V fuse protecting the high current input terminal (10A) Max. crest factor: 3.0 at full scale Resistance (2-Wire and 4-Wire) (1) Test Current Continuity 120.000 Ω 1 mω 119.999 1 ma 0.05 +0.008 (2) 1.20000 kω 10 mω 1.19999 1 ma 0.03 +0.004 (2) 12.0000 kω 100 mω 11.9999 100 µa 0.03 +0.004 (2) 120.000 kω 1 Ω 119.999 10 µa 0.03 +0.004 1.20000 MΩ 10 Ω 1.19999 10 µa 0.03 +0.004 12.0000 MΩ 100 Ω 11.9999 7.0/(10M+Rx) µa 0.10 +0.004 120.000 MΩ 1 kω 119.999 7.0/(10M+Rx) µa 0.50 +0.008 (1) In order to eliminate the noise interference, which might be induced to the test leads, it is recommended to use a shielded test cable for measuring resistance above 120 kω (2) Using REL function Input protection: 1000 Vdc or 750 Vac for all ranges Note: Rx is the measured resistance value Diode Test Current 1 kω 100 mω 999.9 1 ma 0.1%+0.02% For 0.1 PLC (Fast) Input protection: 1000 Vdc or 750 Vac Test Current 3.0000 V 100 µv 2.9999 1 ma 0.030+0.020 10.0000 V 100 µv 10.0000 100 µa 0.030+0.020 10.0000 V 100 µv 10.0000 10 µa 0.030+0.020 For 1 PLC (Medium) Input protection: 1000 Vdc or 750 Vac for all ranges 4 www.bk precision.com

Specifications (cont.) Frequency ACV 100 mv to 750 V Period ACV Period 100 mv to 750 V (2) Input Sensitivity (Sine Wave) 1 ~ 10 µs (1) 0.01 ns 9.99999 0.005 100 mvrms 10 µs ~ 10 ms 0.1 ns 9.99999 0.005 40 mvrms 10 ms ~ 100 ms 0.1 µs 99.9999 0.01 40 mvrms 100 ms ~ 200 ms 1 µs 199.999 0.05 200 mvrms (1) If testing frequency is greater than 1MHz, it will be displayed but no specified accuracy is guaranteed. (2) Specified accuracy at input >5 % of range. Supplemental Environmental Operating Environment 0 C to 40 C, 32 ºF to 104 ºF Storage Environment -40 C to 70 C -40 ºF to 158 ºF General Frequency Humidity Remote Interfaces 90 %RH RS232, USB (virtual COM) GPIB (model 5492BGPIB only) Measurement Category CAT II 300V, CAT I 1000V, pollution degree 2 Math Functions Rel, Max/Min/Average/StdDev (for stored readings), db, dbm, Limit Test, % and mx+b AC Input 110/220 V ± 10%, 50/60 Hz ± 5% Power Consumption Safety & EMC Dimensions (W H D) Net Weight Included Accessories 20 VA EN 61010-1:2001, EN61326-1:2006 and EN61326-2-1:2006 8.85 x 3.93 x 13.97 (225 mm 100 mm 355 mm) 5.51 lbs (2.5 kg) (2) Input Sensitivity (Sine Wave) 5 ~ 10 Hz 10 µhz 9.99999 0.05 200 mvrms 10 ~ 100Hz 100 µhz 99.9999 0.01 40 mvrms 100 ~ 100 khz 1 mhz 999.999 0.005 40 mvrms 100 k ~ 1 MHz (1) 1 Hz 999.999 0.005 100 mvrms (1) If testing frequency is greater than 1MHz, it will be displayed but no specified accuracy is guaranteed. (2) Specified accuracy at input >5 % of range. Gate Time at 1 Sec. Input protection: 750 Vrms or 500 Vdc Gate Time at 1 Sec. Input protection: 750 Vrms or 500 Vdc Three-Year Warranty Test leads, AC power cord, spare fuse, user manual, USB cable, calibration certificate and test report 5 v041014 www.bk precision.com