Visual grading of large cross section structural timber of Pinus sylvestris L. according to UNE 56544:2007 standard

Similar documents
Chapter 6. Lumber Stress Grades and Design Properties. Contents. David E. Kretschmann and David W. Green

NATIONAL ASSESSMENT DIRECTIVE FOR THE PRODUCT CERTIFICATE FOR WOODEN SCAFFOLDING BOARDS

APPEARANCE GRADING OF SAWN OAK (French grading rules as published by APECF Association Pour la Promotion des Emplois du Chêne et du Hêtre Français)

What Can I Expect from Synergy?

Nanping Weishi LVL Scaffold Plank Brochure

DETERMINATION OF WOOD MOISTURE PROPERTIES USING CT- SCANNER IN A CONTROLLED ENVIRONMENT

Owner s Guide to Understanding Checks in Glued Laminated Timber

Glulam Appearance Classifications for Construction Applications

How To Make An Oriented Strand Board

CP CHEMICAL INDUSTRY PALLETS Edition: 6

Post and Beam Construction

Mechanical characterization of visually classified, small-diameter laricio pine round timber

European Technical Assessment ETA-10/0153 of 10/06/2015

SPLITS AND CRACKS IN WOOD

SmartPly OSB3 SMARTPLY

R e q u e s t f o r Q u o t e s H a r d w o o d S w i t c h T i e s , , C a p i t a l M a i n t e n a n c e P r o g r a m

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001

Structural fire design Eurocode Timber structures

LOAD-CARRYING CAPACITY OF AXIALLY LOADED RODS GLUED-IN PERPENDICULAR TO THE GRAIN

General Approach. Structure Components. Is all lumber the same? Lumber Grades. Rafters Girders / Beams Columns. Sketch general structural layout

Timber Decks. Technical Note. March 2007

Synergy Wood Products, Inc.

MOISTURE REMOVAL FROM GREEN SAPWOOD DURING PLATEN PRESSING

TECHNICAL RECOMMENDATION

Nordic requirements for quality control of preservativetreated

NUMERICAL ANALYSIS OF GLULAM BEAMS WITHOUT AND WITH GFRP REINFORCEMENT

Mezzanine. Technical manual

INTERGOVERNMENTAL STANDARD GOST

TECHNICAL INFORMATION SHEET

Timber Structures (material, design & case study) University of Cambridge Year 2 Architecture by Simon Smith

BETONYP building boards. The modern way of living.

Product Data Sheet ROCKPANEL Rockclad

Formwork for Concrete

Light-Weight Panels. High quality panels.

Ageing effect and long term performance of cement bonded particleboard. Prepared for: Viroc Portugal Indústrias de Madeira e Cimento S.A.

Code of Standard Practice for Timber Frame Structures

SECTION GUARDRAILS

Lumber Grading. The Lumber Grade Your Guarantee of Quality Building Products

Units of Measure and Conversion Factors for Forest Products

Fire safety in timber buildings

SUSTAINABLE TIMBER PRODUCTS UPM TIMBER

B. Related categories: The following categories contain requirements that relate to this section:

What Do You See? FOR 274: Forest Measurements and Inventory. Logs and Scaling: Definitions. Tree and Wood Volume Log Volumes Cords Weight Scaling

Durability of acetylated Radiata Pine investigation of the resistance against brown-, white- and soft rot fungi

Design guide. Part 1: Structural Design

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

Apr 17, 2000 LAB MANUAL

Hardened Concrete. Lecture No. 14

Schwerlastbrücke (68 m Spannweite) im Norden von Canada

Bracing Webs in Trusses that have Dissimilar Configurations

LACQUERED HDF RAW HDF. Kronospan-MOFA Hungary Kft. has become one of the biggest and most modern producers of thin boards of Europe today.

Strip Flatness Prediction in a 4 High Tandem Mill Using a Dynamic Model.

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

CHAPTER 3.0 TIMBER PILE PROPERTIES

Design Approach: 3) Full Sawn: In this case a rough surface is obtained with actual size equal to the nominal size.

Optimising plate girder design

TIMBER INFORMATION GUIDE 2008/09.

Wood Projects Outdoors. Post Hole Specifications. Deck Span Tables. Eakes.com

NATURAL DURABILITY OF DIFFERENT WOOD SPECIES RESULTS AFTER FIVE YEARS TESTING IN GROUND CONTACT

December J-Ply Roofing, Flooring and Decking

Additional requirements and conditions for abrasive products to be marked with the osa symbol

MATERIALS AND MECHANICS OF BENDING

Cost Action FP1101 Assessment, Reinforcement and Monitoring of Timber Structures

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February Foundation Heave Protection

Quality control: Annex-A.

Local buckling of plates made of high strength steel

TEKA RESIDENTIAL WARRANTY PROGRAM LIMITED WARRANTIES. February, 2004

Utilization of Agricultural Waste for Composite Panels

YEAR TRANSFERRABLE TANALISED 25 YEAR TERMITE RESISTANT* STRUCTURAL TIMBER AND WOOD PRODUCTS GUARANTEE

WEST VIRGINIA SPLIT RAIL

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

Chapter 7. Chips, Sawdust, Planer Shavings, Bark, and Hog Fuel

Strategies to Reduce Defects in Floor and Wall Tiles; Application of Continuous Improvement Processes

Chapter 8 Design of Concrete Mixes

Design and Construction of Cantilevered Reinforced Concrete Structures

Tried, Tested and Proven Timber Protection

Tree Structure - Dynamics Ken James University of Melbourne, Australia

Are My. Pine Trees. Ready To Thin?

How to Install Hardwood Flooring Over a Sub Floor

C. Section TESTING LABORATORY SERVICE.

Failure analysis on timber structures in Germany

STANDARD OPEN PATIO COVER

EFFECTIVE BENDING CAPACITY OF DOWEL-TYPE FASTENERS

FINAL FAILURE INVESTIGATION WESTCHESTER NORTH LAGOON BRIDGE. Anchorage, Alaska

DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA

STRENGTH OF CONCRETE INCORPORATING AGGREGATES RECYCLED FROM DEMOLITION WASTE

Lap Fillet Weld Calculations and FEA Techniques

Fire, Forest History, and Ecological Restoration of Ponderosa Pine Forests at Mount Rushmore, South Dakota

Compression load testing straw bale walls. Peter Walker Dept. Architecture & Civil Engineering University of Bath Bath BA2 7AY.

Contents. Introduction 1. Measurement 2-3. FAS and FAS/1F grades 4. No. 1C and No. 2AC grades 5. Characteristics and defects 6-7. Ash 8.

AISI O1 Cold work tool steel

Mold Preventing I nterior System

The University of Birmingham (Live System)

LEROY MERLÍN FUNDACIÓN JUAN XXIII-IBERMAIL. A Study of Forest Biomass Sustainability SHOUF BIOSPHERE RESERVE, LEBANON THERMAL BIOMASS PROJECT 2013

POWER PRESERVED GLULAM BEAMS AND COLUMNS. Certified Building Products

1 H ANDBOOK OF FINNISH PLYWOOD

Lab for Deflection and Moment of Inertia

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

Cable Trays Technical Instructions & Specifications

Transcription:

Visual grading of large cross section structural timber of Pinus sylvestris L. according to UNE 56544:2007 standard María-José Montero 1, aquel Mateo 2, Guillermo Íñiguez-González 3, Francisco Arriaga- Martitegui 4, Eva Hermoso 5, Miguel Esteban 6 Abstract Large cross section structural timber have been used in many structures over long periods of time and still make up an important part of the market due to its mechanical properties. Furthermore, it is frequent its employment in new construction site. It involves the need for a visual grading standard for timber used in construction according to the quality assessment. The material has to satisfy the requirements according to the currently regulations. UNE 56544 is the Spanish visual grading standard for coniferous structural timber. The 2007 version defined a new visual grade in the standard for large section termed Structural Large Timber (). This research checks the new visual grading and consists of 116 structural size specimens of sawn coniferous timber of Scotch pine (Pinus sylvestris L.) from Segovia, Spain. The pieces had a cross section of 150 by 200 mm. They were visually graded according to UNE 56544:2007. Also, mechanical properties have been obtained according to standard EN 408. The results show very low output with an excessive percentage of rejected pieces (33%). The main reasons for the rejection of pieces are fissures and twist. Keywords visual grading, Pinus sylvestris L., structural timber, large cross section 1. INTODUCTION Non-destructive evaluation is the science of identifying physical and mechanical properties of a material without altering its final application capabilities (oss et al. 1998). It is an important tool and it can be used in the industry. 1 María-José Montero, Departamento de Construcción y Vías urales, Universidad Politécnica de Madrid, España, mj.montero@upm.es 2 aquel Mateo, AITIM, España, r.mateo@aitim.es 3 Guillermo Íñiguez-González, Departamento de Construcción y Vías urales, Universidad Politécnica de Madrid, España, guillermo.iniguez@upm.es 4 Francisco Arriaga-Martitegui, Departamento de Construcción y Vías urales, Universidad Politécnica de Madrid, España, francisco.arriaga@upm.es 5 Eva Hermoso, Centro de Investigación Forestal, INIA, hermoso@inia.es 6 Miguel Esteban, Departamento de Construcción y Vías urales, Universidad Politécnica de Madrid, España, miguel.esteban@upm.es 1

It is completely accepted that structural sawn timber should be strength graded before use. For this purpose a major range of standards has been developed, and much research on the grading and sources has been carried out to evaluate timber quality. The visual grading technique for wood quality assessment is based on measurement of the singularities and characteristics present in timber pieces, such as: knot size, slope of grain, presence of pith, bark and resin pockets, fissures, distortions, etc. Their limits define the different visual grades. UNE 56544:2007 is the in force Spanish visual grading standard for coniferous structural sawn timber. It covers, among others, Scotch pine (Pinus Sylvestris L.) It defines a new visual grade in the standard for large section termed Structural Large Timber (). This standard is the result of several research projects (Martinez 1992, Hermoso 2001, Conde 2003, Íñiguez 2007). Samplings tests were carried out according to European standards EN 408:2003 and EN 384:2004, and they have been validated by the CEN TC 124 Committee to be added to the European standard EN 1912 (2010). The main goal of this paper is to evaluate this standard and propose other non-destructive methods for grading the structural timber. 2. MATEIAL TESTED The sample studied consisted of 116 structural size specimens of sawn coniferous timber of Scotch pine (Pinus sylvestris L.) from Segovia, Spain. The pieces had a cross section of 150 by 200 mm. They were selected and graded when its moisture content was > 20%, and its visual grading was Structural Large Timber (). The test material was selected to evaluate the drying effect on the visual grading of structural large timber (). The sample represents the timber source and sizes that will be graded in production. 3. METHODOLOGY 3.1. Moisture content The moisture content (MC) of all the pieces was evaluated using electrical resistance equipment following the procedure defined in EN 13183-2:2002. The MC of pieces in sawmill was upper to 20 % in all of them. Sawn timber pieces were air dried for twelve months. The average MC of pieces was 9,86 %, going from 7,1 % to 13,5 % after drying process. 3.2. Visual Grading Specimens were visually graded according to UNE 56544:2007. This standard defines one visual grade for structural coniferous timber with > 70 mm thickness (). The grade was assigned before the bending test was performed, considering the most unfavourable section in the whole length of the beam. The Strength Class assigned to the visual grade of Scots pine according to the EN 1912:2010 standard is C22. According to the EN 338:2003 standard, the C22 Strength Class corresponds to a characteristic value of bending strength (f m ) of 22 N/mm 2, a medium value of modulus of elasticity (E m ) of 10 N/mm 2 and a medium value of density (ρ m ) of 340 kg/m 3. The requirements of this grade are summarized in Table 1. Table 1 Specifications proposed in UNE 56544:2007 for Pinus sylvestris L. timber with thickness > 70 mm Specifications Face (h) knot diameter Edge (b) knot diameter Maximum width of annual ring a Fissures d 2/3 of h d 2/3 of b Unlimited e 2

Seasoning checks b,c f 2/3 of b Those fissures are considered only if they are longer than 1 m or 1/4 of L Other types ing shakes esin and bark pockets It is accepted if its length is 1/5 of h Compression wood Accepted 2/5 of the cross section. Slope of grain 1:6 (16,7%) Wane Length 1/3 of L elative dimension g 1/3 Pith a Accepted Biological damage Mistletoe Blue stain Accepted Fungi decay Insect s galleries Distortions b,c,d Bow 20 mm over a length of 2 m Spring 12 mm over a length of 2 m Twist 2 mm per 25 mm width over a length of 2m Cup 1/25 of h a Those specifications are considered if it is wet timber commercialized. b Those specifications are not considered in case of wet grading. c eferred to 20 % of MC. d Higher distortions can be accepted if it is not a problem for the construction stability (because it can be corrected during the assembly) and if there is an agreement between supplier and customers. e Indicates one of the following: b: thickness, h: with, L: length of the piece, d: knot diameter measured for individual knots and groups of knots, f: sum of the fissure depths of both faces divided by width of the piece. 3.3. Physical and mechanical properties The density ( ) was determined following the methodology of the standard EN 408:2003, using a cross section slice (150 mm x 150 mm x 200 mm ) free of defects from a zone close to the rupture section and referred to 12% MC. The global elasticity modulus (E) and bending strength (f m ) were obtained according to the EN 408 standard (2003). The test consists on a simply supported beam with 18 h span and symmetrically loaded in bending at 6 h. According to the standard EN 384:2010, E values were adjusted to 12 % MC by the appropriate correction. There were no modifications of f m because of MC. 4. ESULTS AND DISCUSION The output of grading of wet (all the pieces) and dry (according to the different criteria of grading) timber obtained using the standard are shown in Table 2. Table 2 Visual strength grading according to UNE 56544:2007. Percentage of pieces complying with specifications. Wet and dry timber. Specifications (%) (%) Wet timber (all the pieces) 100 0 Dry timber (according criteria) Face knot 99 1 Edge knot 98 2 Fissures 87 13 esin pockets 100 0 Bark pockets 97 3 3

Slope grain 98 2 Wane 98 2 Biological damage 100 0 Distortions Bow 100 0 Spring 98 2 Twist 88 12 Cup 100 0 Dry timber (all the pieces) 67 33 In the sawmill all of the pieces were selected and graded when wet as according to the current standard (UNE 56544:2007). After drying, only 67 % of the pieces could be graded as, so a 33 % of the pieces were rejected. The main reasons for the pieces rejection were fissures (13 %) and twist (12 %). It means that the 73 % of the rejected pieces were rejected due to fissures and distortions, which are effects of this drying process. Lower rejection percentages were owing to subjective aspects in visual grading and loss of section because of the drying process. After the visual grading, mechanical and physical properties of all the pieces were obtained. The density ( ), modulus of elasticity (E) and bending strength (f m ) values obtained are included in Table 3, and the statistical comparison between or rejected pieces are shown in the Figures 1 to 3. As can be seen, no significant differences between the mechanical and physical properties of and rejected pieces can be found. Table 3 Mechanical properties for each visual grade. Dried timber. Mechanical properties TOTAL 116 pieces. 100% 78 pieces. 67% ejected 38 pieces. 33% Average 5 th percentile Average 5 th percentile Average 5 th percentile (kg/m 3 ) 485 419 481 417 495 428 E (N/mm 2 ) 9391 7286 9320 7317 9537 6896 f (N/mm 2 ) 41,26 24,11 40,24 23,85 43,36 23,60 510 10 500 9,8 490 480 9,6 9,4 9,2 470 9 Figure 1 Means plot of one-way analysis of variance: eb (kg/m 3 ) vs. Visual grade. Figure 2 Means plot of one-way analysis of variance: E (N/mm 2 ) vs. Visual grade. 46 44 42 40 38 Figure 3 Means plot of one-way analysis of variance: f (N/mm 2 ) vs. Visual grade. 4

On the other hand, if the effects of the drying process are not considered on the visual grading the results are showed in Table 4, and the comparison between visual grades are shown on the Figures 4 to 6. Similar conclusion can be obtained in comparison with the precedent results. Table 4 Mechanical properties for each visual grade. Dried timber. Without considering fissures and distortions Mechanical properties TOTAL 116 pieces. 100% 110 pieces. 91% ejected * 6 pieces. 9% Average 5 th percentile Average 5 th percentile Average 5 th percentile (kg/m 3 ) 485 419 485 418 485 430 E (N/mm 2 ) 9391 7286 9421 7290 9074 7290 f (N/mm 2 ) 41,26 24,11 41,68 20,48 36,89 24,17 * The sample is not representative. The number of pieces is insufficient. Medias y 95,0 Porcentajes Intervalos LSD 510 500 9,9 9,6 490 9,3 480 9 470 8,7 460 8,4 Figure 4 Means plot of one-way analysis of variance: eb (kg/m 3 ) vs. Visual grade. Figure 5 Means plot of one-way analysis of variance: E (N/mm 2 ) vs. Visual grade. 46 TD hpos 43 40 37 34 31 Figure 6 Means plot of one-way analysis of variance: f (N/mm 2 ) vs. Visual grade. 5. CONCLUSIONS Mechanical and physical properties values of the tested sample graded as are congruent with the C22 Strength Class assigned on the current version of the EN 1912:2010 standard. Drying effects are the reject reason of the 25 % of the pieces previously graded as when green. There are no significant differences between mechanical properties of the visual graded pieces attending to the criteria of fissures and deflections related to the drying process, among the rest of the visual criteria, or graded without attending to these criteria. EFEENCES Conde, M. 2003. Caracterización de la madera estructural de Pinus nigra Subs salzmannii. Universidad Politécnica de Madrid. E.T.S. de Ingenieros de Montes. Tesis Doctoral. EN 13183-2:2002. Moisture content of a piece of sawn timber. Part 2: Estimation by electrical resistance method. European Committee for standardization. Brussels. 5

EN 1912:2010. Structural timber. Strength classes. Assignment of visual grades and species EN 338:2003. Structural timber. Strength classes. EN 384:2004. Structural timber. Determination of characteristic values of mechanical properties and density. European Committee for standardization. Brussels. EN 408:2003. Timber structures. Sawn timber and glued laminated timber for structural use. Determination of some physical and mechanical properties. European Committee for standardization. Brussels. Hermoso, E. 2001. Caracterización mecánica de la madera estructural de Pinus sylvestris L. Universidad Politécnica de Madrid. E.T.S. de Ingenieros de Montes. Tesis Doctoral. Íñiguez, G. 2007. Clasificación mediante técnicas no destructivas y evaluación de las propiedades mecánicas de la madera aserrada de coníferas de gran escuadría para uso estructural. Universidad Politécnica de Madrid. E.T.S. de Ingenieros de Montes. Tesis Doctoral. Martinez, J.J. 1992. Características mecánicas de la Madera de Pinus Pinaster Ait. Obtenidas a partir de ensayos con piezas de tamaño estructural. Universidad Politécnica de Madrid. E.T.S. de Ingenieros de Montes. Tesis Doctoral. oss,.j., Bradshaw, B.K., and Pellerin,.F. (1998). Nondestructive evaluation of wood Forest Prod. J.48, 14-19. UNE 56544:2007. Clasificación visual de la madera aserrada para uso estructural. Madera de coníferas. Madrid. Spain. 6