Fire Detection Technologies A Complete Review

Similar documents
Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products

How to Select a Flame Detector

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

Module 5. Fire and Emergency Alarm System Part I- Basics

Application Requirement

Fire detection in kitchens

Full protection means protection by multi-sensor technology

Fire Alarm Systems for Life Safety Code Users

Analogue addressable devices

EARLY WARNING OF FIRE AND HYDROGEN GAS THREATS IN BATTERY SPACES

The photoionization detector (PID) utilizes ultraviolet

Principles of ASA firedetection

Fire detection equipment

Fire Development and Fire Behavior Indicators

FSD Circular Letter No. 7/95 Automatic Fire Detection System - Design and Maintenance Considerations

Overview. What is EMR? Electromagnetic Radiation (EMR) LA502 Special Studies Remote Sensing

SPECIAL APPLICATIONS

Section 6 Fire Detection and Alarm Systems Russell Porteous Chief Executive Officer Firewize Services

Ionization alarms are best suited for rooms, which contain highly combustible material. These types of material include:

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

SECTION FIRE ALARM AND DETECTION SYSTEMS

A P P L I C A T I O N S G U I D E. Single-Ended Reflective Beam Smoke Detector

The Three Heat Transfer Modes in Reflow Soldering

Relative Sensitivity based Fire Detection Systems used in High Density Computer Rooms with In-Row Air Conditioning Units

Alarm and Detection/Suppression

THE DETECTION OF GREENHOUSE GASES

)454, &IRE DETECTION AND ALARM SYSTEMS DETECTOR AND SOUNDER DEVICES

Validation of Modeling Tools for Detection Design in High Airflow Environments

Distributed Temperature Sensing - DTS

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

Fire Performance Standard

Single-Ended Reflected Beam Smoke Detector

Online Infrared Flue Gas Analyzer Gasboard 3000

WHITE PAPER Fire & safety performance standards

N4385A / N4386A Distributed Temperature System (DTS)

Fire Resistance and Safety in Case of Fire

Technological Advances in Smoke Alarms

Laser Technology Smoke Detector

Triple Waveband Infra-Red Flame Detection

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

Flame detection across the spectrum. Range Brochure

What Is Heat? What Is Heat?

720r Addendum: Siting the 720r

Substations. Design Guide. January, 2010 Doc 11737_00

FAAST. Fire Alarm Aspiration Sensing Technology

E2-E3: ELECTRICAL CHAPTER-13 FIRE PROTECTION SYSTEM- EVOLVING TRENDS AND APPLICABILITY TO DATA CENTRE

OHIO BOARD OF BUILDING STANDARDS. Smoke Alarms and Fire Safety

Gas-Fired, Residential Storage Type Water Heaters

CBD-233. Fire Alarm and Detection Systems

Chapter 2: Forms of Energy

ABSTRACT INTRODUCTION

Laser Technology Smoke Detector

Convection, Conduction & Radiation

From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?

Electromagnetic Radiation (EMR) and Remote Sensing

HAZARD CONTROL TECHNOLOGIES, INC. Coal Silo-Bunker Firefighting Procedures

Energy Efficient Operations and Maintenance Strategies for Boilers

White Paper. Detecting Hydrogen Sulfide Gas and Understanding its Danger in the Field. Introduction

CO 2. fire extinguishing systems

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

The soot and scale problems

Dew-Point Measurement Solutions

Chemical Reactions Practice Test

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

Design Standards Fire Alarm Systems Division (1995 CMS); (2004 CMS) Amended Feb 2015

Fire protection in archives and storage vaults

DLO1191 Linear smoke detector

Beam Detection Systems Application Guide

Facility Operations Physical Safety Guidance Document

Energy and Energy Transformations Test Review

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Case Studies: Infrared Heating in Industrial Applications

BRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.

Improving Steam Methane Reformer Performance with the ZoloSCAN-SMR

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Certification of construction products - Fire dampers. Certification Rules 032

MICROPACK Visual Flame Detection Application Note

Experion Integrated Fire & Gas Safety and Security Monitoring at your fingertips! Ajay Varghese

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

How To Set Up A Fire Alarm System

Fire & Gas Detection; Reducing Risks in Rail Loading/Unloading Facilities. By Todd Spicer Technical Specialist Spartan Controls Fire & Security

Buckeye Detection Systems Fixed Detection Systems Application Survey

Mineral Insulated Cable A cable for today and tomorrow!

OPAL TM Detector range

Fossil fuel heating equipment

Hygro-Thermometer + InfraRed Thermometer Model RH101

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

Fire Alarm System Accessories

During Various Aluminum Fabricating Operations

Owner s Manual

Factory owners must ensure the boiler is:

Fire alarm system EBL512 G3

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Process Safety Management of Highly Hazardous & Explosive Chemicals. Safe Work Practices

Smoke & Carbon Monoxide

EVALUATION OF THE PERFORMANCE OF FIRE DETECTION SYSTEM IN AN INSTITUTIONAL BUILDING

On-Line Fire Extinguisher Training

Fire Facts Smoke Alarms

POROUS BURNER - A New Approach to Infrared

Transcription:

Fire Detection Technologies A Complete Review

Course Outline What is Fire? How do we detect Fire? Construction Challenges Future Detection Technologies Application Solutions The Saving of Lives Page 2

What is Fire?

Fire Principles For a fire to break out, combustible material (fuel) and an oxidation agent (usually oxygen) must be available. Our environment is to a large extent made up of combustible materials and oxygen is virtually always sufficiently available. But another condition must be fulfilled for a fire to break out: The ignition energy (heat) must be the driving force to initiate oxidation. Ignition energy sources are manifold: Electrical discharge (e.g. lightning), short-circuits, flying sparks, hot surfaces (light bulbs, heating equipment, etc.), direct exposure to flames or bundled light, to name only the most important ones. If a fire occurs, it provides the necessary energy to maintain the combustion process. The Fire Tetrahedron Page 4

Stages of Fire Development Incipient stage: Little visible smoke occurs, but especially invisible aerosols are generated. Smoldering stage: In this phase, the fire can be extinguished by means of a fire extinguisher or a similar extinguishing agent. Visible, partly dense smoke occurs. Usually, combustion is incomplete, which is why rather a lot of (toxic) CO is produced in this phase. Flaming stage: We are faced with an open fire to be fought by the fire brigade. As enough energy is available, the combustion process is rather complete, resulting in a high production of CO2. Heat Stage or Flashover: This is the explosive fire spread, taking place exactly at the point when the gases and aerosols produced during the previous phases ignite and carry the fire into all rooms already penetrated by the smoke gases. Page 5

Products of Combustion Throughout the various stages of fire development and the types of fuel loads consumed it is important to select the most appropriate detection technology for the expected fire. Frequently the design parameters require different technologies to accomplish the goal of fast and reliable fire detection. Type of fire Properties and fire phenomena Combustion process Pyrolytic decomposition (carbonization process) Not independent, requires continuous energy supply Glowing fires Independent after ignition Solid matters (mostly emberforming fire) Independent after ignition Liquid matters (flame combustion) Independent after ignition Type of smoke (aerosol) Very light smoke Light smoke Dark smoke Very dark smoke Optical properties of smoke Quickly spreading Quickly spreading Strongly absorbing, spreading little Aerosol volume High High High Strongly absorbing, spreading little High (except pure alcohol: none) Stages of Fire Development UV / IR radiation Low Low to medium High High Gaseous matters(flame combustion) Independent after ignition Increases with C-share Heat convection Low Low to medium High High High Combustion gases Smoldering fires (non-flaming fires) Open fires (flaming fires) Much CO, little CO2 Much CO, little CO2 Little to much CO, much CO2 Little CO, much CO2 Little CO, much CO2 Sound None None None to much None to much None to much Pressure increase None None Lowto medium, depending on the fuel Low to high, dep. on fire phenomenon Depending on the carbon share of the gas, its chemical properties andmixing with oxygen Low Page 6

How do we detect Fire? Heat Detection Spot Smoke Detection Beam Smoke Detection Duct Smoke Detection Aspirating Smoke Detection Flame Detection

Heat Detectors fixed temperature snap disc Bifurcated leaf Page 8

Heat Detectors Rate of Rise & Fixed Temp. Combination detectors have both fixed and rate-of-rise elements. The fixed element is generally a non-restorable type, and when activated, must be replaced. The rate-of-rise element is restorable when conditions return to normal. Alarm Contacts Rate of Rise Vent Fixed Heat Collector Fixed Actuator Rate of Rise Diaphragm Eutectic Solder (thermal lag) Page 9

Rate Compensation Detector Rate Anticipation Detector Fixed Temperature only Not Subject to Thermal Lag Page 10

Spot Smoke Detection Ionization Principle of Detection Changes in Conductivity 241 Am (Americium 241) source of alpha particles Half-life of 241 Am is 432.2 years Alpha particles are emitted to create current flow Emitter and collector electrodes measure changes Smoke particles absorb alpha particles and reduce current flow to create an alarm Application Notes Detects fire in the incipient stage small invisible smoke particles Detects particles < 3 microns in size More unstable at higher airflows Requires proper safe disposal procedures Page 11

Spot Smoke Detection Photoelectric Principle of Detection Light Extinction Infrared LED light source constant signal Smoke entering the chamber absorbs and scatters light signal is reduced Suitable for all fires producing visible smoke Poor maintenance produces false alarms Principle of Detection Light Scattering Infrared LED light source blocked by labyrinth Smoke entering the chamber and scatters light, hits the receiver and produces a signal Forward scatter detectors suitable for suitable for smouldering fires with light smoke Backward scatter detectors can be better balanced and made suitable for light or dark smoke Poor maintenance produces false alarms or puts detectors to Sleep Page 12

Multi-sensor (Element) Detector 2 or more sensors in a single package (independent) Not true Multicriteria Most commonly optical smoke sensor with a heat detector Smoke sensors (Scattered light, extinction, laser, ionization) Heat sensors (fixed, rate of rise, rate compensated) Gas sensors (CO, CO2) Optimize performance of each sensor Page 13

Fire Detection Fuzzy Logic Is this a real fire or a false phenomenon How do you tell the difference? - When does a boy become a man? Page 14

True Multi-Criteria Fire Detection Consider What we know about fire - Products of combustion? The environment - POC normally present? - What will be burning (fuel)? The signals - The change in signals - The rate of change in signals The history of this situation Page 15

Fire Detection Fuzzy Logic Is this a real fire or a false phenomenon How do you tell the difference? - When does a boy become a man? Page 16

Beam Smoke Detection - Principle The emitter sends out a focused light beam. When there is no smoke, this light beam reaches the receiver in its unattenuated intensity. However, if there is smoke between the emitter and the receiver, the light is partly absorbed when impinging the smoke particles and partly scattered by them, meaning that it changes direction. Only a part of the emitted light can reach the receiver. The signal reduction indicates the average smoke density over the measuring section. As the linear smoke detector reacts on absorption and scattering, it is suited for light and dark, large and small aerosols. It is characterized by its uniform response behavior and is suited for the early detection of all fires generating visible smoke. Systems accommodating the emitter and receiver in the same housing use a remote reflector and have the advantage that they need to be connected to the detector line at one point only, and that maintenance is easier. Page 17

Open-area Smoke Imaging Detection OSID Page 18

Duct Smoke Detector Typical Application Detector Locations Downstream of the air filters and ahead of any branch connections in the air supply systems having a capacity greater than 2000 ft 3 /min. At each story prior to the connection to a common return and prior to any recirculation or fresh air inlet connection in the air return systems having a capacity greater than 15,000 ft 3 /min and serving more than one story. Example Detector Installation Note: The sum of the cross sectional area of inlet holes MUST equal cross sectional area of inlet tube! Page 19

Aspirating Smoke Detection Principle Aspirating smoke detectors are also known as air sampling smoke detection system or aspiration smoke detection (ASD). In the air sampling smoke detection system, air samples from the monitored area are guided to the detection chamber via a pipe network by means of a powerful suction system. The photoelectric detection principle using a laser providing much less reflected light under normal circumstances which increases sensitivity while maintaining stability. Page 20

Aspirating Smoke Detection Sample Layout Air sampling piping network provides inlets which are spaced as smoke detectors. There is no reduction needed for high air flow as with spot smoke detectors. Page 21

Linear Heat Detection Detection Principle Direct Shorting of Conductors at Specific Temperatures (350-500 degrees typical) Manufacturer specific panels can provide approximate locations of wiring faults to provide point annunciation of the location of alarm. Wiring Construction Steel Conductors are used in a twisted pair to form the Inner Core Conductors are wrapped in a heat sensitive polymer to insulate the them from each other and prevent shorting Protective Tape is then used to protect the conductors from physical damage Outer jacket is then applied to protect cable from environmental conditions specific to the installation Page 22

FibroLaser This system is based on a laser beam being sent through a fiber-optic cable. As the fiber-optic cable reflects a small part of the laser radiation at any point, the backscatter can be measured by a receiver connected at the same end as the laser source. The fiber-optic cable is a doted quartz glass, i.e. a form of silicon oxide (SiO 2 ). The infrared electromagnetic laser radiation emitted is reflected in different ways by the fiber-optic cable: Rayleigh scattering same frequency Raman scattering Stokes + frequency Raman scattering Antistokes - frequency The temperature of the fiber-optic cable thus results from the intensity ratio between Stokes and Antistokes scattering. By means of runtime measurements, it is possible to measure the associated Raman scattering for each cable spot. Page 23

Flame Detector Principle of Detection Changes in Radiant Energy Detects IR, UV and Flicker Rate of 0.5-15Hz to verify flame Safe for Class I. Div 1 Hazardous areas Calibrated for a 1 sq. ft gasoline pan fire (60, 30, 15 ft selectable) Wired and supervised as a 4-wire initiating device (24vdc required) Page 24

Detector Response Summary The selection of the optimum fire detector is based on the expected fire phenomena, generated by the incipient fire. For an office building, smoke detectors will preferably be selected, as in this case fires will produce clearly visible smoke both in the incipient phase and later. In a storage area where combustible liquids are stored, flame detectors and / or heat detectors would be the right choice. To be able to reliably detect all expected incipient fires, it may be necessary to combine different fire detector types. Page 25

Construction Challenges

Construction Challenges Considerations in product and technology selection Accessibility for Maintenance Atriums Extreme Environments (Temperature, Humidity, Dust, Corrosive) Data Centers (High Airflow, Early Warning, Limited Access) Hazardous Environments (Class 1 Division 1) Explosion Proof Page 27

Future Technologies

RED & BLUE light scattering ASD technology Distinguishes between large particles that are typical dirt and the small smoke particles typical in incipient fires better than red infrared based technology alone. Discriminates between Smoke & Dust /Steam Page 29

Future Technologies Wireless Detection Principle Radio Frequency Transmission Utilizing mesh technology wireless smoke detectors can become integrated into a network whereby the more detectors exist the stronger the network becomes. By acting as a transmitter and a repeater, more detectors create a more robust network that is more resilient than single detectors alone. The detection technology remains unchanged and can therefore utilize photoelectric or ionization detection within the same unit. This technology is approved for use in the European market today and will be accepted by both the NFPA and UL/ULC in the future. More detectors yield more communication pathways for better signal reliability Page 30

Future Technologies Video Smoke Detection Principle The system concept is to utilize advanced video analytics to identify smoke or flame utilizing either existing CCTV cameras or specialized devices. The video signals are run through a software program that processes the change in pixels to determine alarm status. This technology is recognized by NFPA 72 as an alternative provided the specific devices are listed for the purpose. No ULC standards for this yet. Page 31

Page 32

Gas Sensors come into their own The original smoke detector was a failed gas detector 1970 s Cerberus developed a CO sensor, did not catch on in the market 2003 studies by industry researchers explored the use of gas sensors (CO and CO 2 ) in the fire detectors. Initial feasibility studies indicated a substantial reduction in nuisance alarms were possible while maintaining a good response time to fires as compared to smoke detection Today several manufactures including System Sensor, Bosch, Siemens and Simplex have commercially available multi criteria smoke detectors where one of the sensors is a CO gas sensor Including an array of gas sensors within a smoke detector begins to approximate an artificial nose. We are just seeing the beginning of the gases Page 33

The Future To go where Smoke Detection has not gone before Likely path Further development to improve the intelligence of smoke detectors, primarily to discriminate between fire and nuisance sources, but also perhaps to discriminate between fire sources Intelligence can also bring information from an array of smoke detectors to feed a panel to chart the recent course of the fire and direct people to exits away from the fire or heavy concentrations of smoke maybe this could be called Intelligent Response to an emergency situation Page 34

The Future To go were Smoke Detection has not gone before Going further into the future Having a recent history of fire conditions within a space may enable future conditions to be predicted through the use of a reverse algorithm. This would involve using the detector measurements to infer the characteristics of a fire source, e.g. heat release rate, location, fuel etc. These characteristics can then be used as input to enable the use of a computer fire model to predict the future course of the fire. Audio Analytics? Page 35

Application Solutions

Application Solutions Spot Smoke Detection Duct Smoke Detection Aspirating Smoke Detection High Airflow Data Rooms High Humidity and Condensation Amusement Park Rides (limited access) Atriums Spot Heat Detection Rate of Rise w/ Fixed Temp Linear Heat Detection Thermal / Optical Fibre Long runs Limited access Extreme environments Multiple applications Flame Detection IR & UV with Flicker verification Beam Detection Open-area Imaging Smoke Detection Page 37

Challenging Environments for Fire Detection Finding the right solution may require multiple technologies Manufacturing Plants Cold Storage Warehouses Atriums Select a vendor who can apply the best solution to meet the challenge Textile Mills Mines Page 38

The Saving of Lives

The Saving of Lives Since 1970 Smoke Detection has contributed to saving an estimated 90,000 lives Early 1900 s 15,000 people per year die in FIRES 1960 s 8,500 people per year die in FIRES 2010 3,300 people per year die in FIRES Page 40

Thank you bill.lane@siemens.com don.boynowski@siemens.com