Nitrogen Generators with Research Grade Purity

Similar documents
Analytical Gas Systems Products for Chromatography

Laboratory Gas Generators. LABGAS Pure & Simple

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

AUTOMATIC CHANGEOVER MANIFOLD Series 915

Kompressoren. Adsorption Dryer AD

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

Pro Dry Heatless dessiccant compressed air dryers

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Nitrogen Generation Systems

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

CONTINUOUS FLOW BREATHING AIR PURIFIERS

Adsorption air dryers ADS 1 215

Validation of process gas systems

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES

ETC -SV. Class 0 oil-free compressed air through catalysis

Atlas Copco Quality Air Solutions. Compressed Air Filters

ThermoStar Refrigeration Air Dryers

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

ThermoSorb Desiccant Dryers

Element D Services Plumbing

Medical Air Systems: Scroll

UOP Gas Processing. Realizing the Value of Your Natural Gas and Synthesis Gas Resources

Desiccant Air Dryers Heatless, Heated and Heated Blower

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.

Electronic component assembly

Hydrogen from Natural Gas via Steam Methane Reforming (SMR)

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

Atlas Copco Compressed air dryers. CD series Heatless adsorption dryer series HIGH QUALITY DRY AIR

3Portable Compressed Air Filter and Regulator Panel , with Carbon Monoxide Filtration and Monitor

Analytical Instruments Smart Analyzer 90 Type SMA

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Brownie s. Tankfill. and. NitroxMakers

UP-213 & UP-266 Pre-Installation Guide

TRL-onlineTOC Monitor is designed for monitoring carbon content in

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

Ultra-Filter. Compressed Air Filter. DF Series

Molecular Sieve Adsorbents

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

Innovative to the Core

CNG, LNG, and Other Fuels from Landfill Gas ---Prospects for Future Development----

Filtering Samples to On-Line Process Analyzers. Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers

Compressed Air Filters

ROTARY SCREW COMPRESSOR. RMD kw

Cartridge Filter Application Notes

HySTAT HYDROGEN GENERATORS

Kompressoren. Oil Water Separators OWS

HYDROTHERMAL OXIDATION HAZARDOUS WASTE PILOT PLANT TEST BED. BY Henry Welland William Reed Dave Valentich Tom Charlton

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

Online Infrared Flue Gas Analyzer Gasboard 3000

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

MERCURY REMOVAL FROM NATURAL GAS & LIQUID STREAMS. John Markovs UOP Des Plaines, Illinois. Jack Corvini UOP Houston, Texas

CONDENSATE MANAGEMENT

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

EMERGENCY VAPOR SCRUBBER SYSTEMS

UHP Zero Air and Hydrogen Generators for Fuel Gas

Marine after-treatment from STT Emtec AB

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Air Eliminators and Combination Air Eliminators Strainers

LABORATORY PRODUCT GUIDE

RiOs 3, 5, 8 Water Purification Systems

WATER SCRUBBING BASED BIOGAS ENRICHMENT TECHNOLOGY BY IIT DELHI

Medical Air Plant. uair Series (7-145 l/s / cfm)

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

SYLOBEAD Adsorbents. for Natural Gas Processing. Introduction. Therefore, it is often necessary to condition the raw gas to:

Possibility of Combustion Furnace Operation with Oxygen-Enriched Gas from Nitrogen Generator

clean and quiet dental

Technical Specification. Generating Set with Waukesha engine burning natural gas

Carbon Dioxide Membrane Separation for Carbon Capture using Direct FuelCell Systems

The photoionization detector (PID) utilizes ultraviolet

HELIAL liquefiers. Range of automatic helium liquefiers.

Nitrogen Generator System Manual

T U R B I N E G A S M E T E R

SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS

LifeASSURE PFS Series Filter Cartridge Integrity Testing

Nitrogen Blanketing for Methanol Storage and Transportation

TTC-IIS Series Up to 11 LPM Free Flow

A practical guide to restrictive flow orifices

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

Simulation of small-scale hydrogen production

Process gases for analytical applications

How To Remove A Large Particle From A Large Tank

CSD WATER REMOVAL FILTERS FOR DIESEL

Dryaire Desiccant System

Uninterruptible Power Supply

SMR Series Submicronic Removal Fluid Purifi cation Systems

Natural Gas Solutions. Applications, Features, Specifi cations

Patient Manual. Oxygen Concentrator

MERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS ABSTRACT. Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA

Oxygen simplified EverFlo concentrators reduce the cost of oxygen therapy

Elemental analyzer multi EA 5000

Rotary Screw Compressors UP-Series 4 & 5.5 kw

LI-7000 CO /H O Analyzer. High Speed, High Precision Differential Analyzer

Rain Cloud (C-21) Product Specifications

Concept WVM Brief description. Effi cient compressed-air adsorption dryer with vacuum regeneration. NEW! Now with improved ZDMC2

HEAVY DUTY STORAGE GAS

Transcription:

Products for Chromatography s with Research Grade Purity Produce a continuous supply of high purity nitrogen gas from existing compressed air Eliminate the need for costly, dangerous, inconvenient nitrogen cylinders in the laboratory Compact design frees up valuable laboratory floor space Offers long term cost stability - uncontrollable vendor price increases, contract negotiations, long term commitments and tank rentals are no longer a concern Model UHPN2-1100 Ideal for carrier gas, make-up gas applications The Parker Balston Models HPN2 and UHPN2 Series s are completely engineered to transform standard compressed air into 99.99% or 99.9999% nitrogen, exceeding the specification of UHP cylinder gas. These systems can produce up to 1.1 lpm of UHP nitrogen gas and up to 2.0 lpm of research grade purity nitrogen gas. Nitrogen is produced by utilizing a combination of state-of-the art purification technologies and high efficiency filtration. Pressure swing adsorption removes O 2, CO 2, and water vapor. A catalyst module is incorporated in the UHPN2 Series to oxidize hydrocarbons from the inlet air supply. High efficiency coalescing prefilters and a 0.01 micron (absolute) membrane filter is also incorporated into the design of the generators. The Parker Balston UHPN2 and HPN2 Series s are engineered and packaged in a small cabinet to fit on or under any benchtop. The systems eliminate the need for costly, inconvenient high pressure nitrogen cylinders. Typical applications include GC carrier and make-up gas and low flow sample concentrators. Flow Table Inlet Air Max Outlet Max Outlet Pressure (psig) Flow (cc/min.) Pressure (psig) Models HPN2-1100 and UHPN2-1100 125 1100 85 110 1000 75 100 900 65 90 800 60 80 700 50 70 600 45 60 500 35 Model HPN2-2000 75-120 2000 90

Principal Specifications s with Research Grade Purity Model HPN2-1100, UHPN2-1100 HPN2-2000 Max Nitrogen flow rate See Flow Table 2 lpm Nitrogen Purity 99.9999% 99.99% Max Nitrogen output pressure See Table 90 psig CO concentration < 1 ppm NA CO 2 concentration < 1 ppm < 1 ppm O 2 concentration < 1 ppm < 100 ppm H 2 O Concentration < 1 ppm < 2 ppm Hydrocarbon concentration (1) < 0.1 ppm NA Argon concentration (2) 0.9% 0.9% Min/Max inlet pressure 60 psig/125 psig 75 psig/120 psig Recommended inlet temperature 78 F (25 C) 78 F (25 C) Ambient operating temperature 60 F-100 F (16 C-38 C) 60 F-100 F (16 C-38 C) Max air consumption 42 lpm (1.5 scfm) 42 lpm (1.5 scfm) Inlet connection 1/4 NPT (female) 1/4 NPT (female) Outlet connection 1/8 compression 1/8 NPT compression Electrical requirements (3, 4) 120 VAC/60 Hz 120 VAC/60 Hz Dimensions 12 w x 16 d x 35 h 12 w x 16 d x 35 h (30cm x 41cm x 89cm) (30cm x 41cm x 89cm) Notes: 1 Models HPN2-1100 and HPN2-2000 do not remove hydrocarbons and carbon monoxide. 2 Purity specification for Nitrogen does not include Argon concentration. 3 Power Consumption is as follows: Model HPN2-1100 = 25 Watts, Model UHPN2-1100 = 700 Watts, Model HPN2-2000 = 25 Watts. 4 Refer to voltage appendixfor electrical and plug configurations for outside North America. Products for Chromatography Ordering Information call 800-343-4048, 8 to 5 EST Description High Purity Ultra High Purity Model Numbers HPN2-2000 Purity Indicator/Scrubber 72092 Optional Prefilter Scrubber Assembly 76080 Pressure Regulator Maintenance Kit Installation Kit for All Models Preventive Maintenance Plan Extended Support with 24 Month Warranty HPN2-1100 and UHPN2-1100 W-425-4032-000 MK7692, MK7694, MKHPN22000 IK7694 HPN2-1000-PM, UHPN2-1100-PM, HPN2-2000-PM HPN2-1100-DN2, UHPN2-1100-DN2, HPN2-2000-DN2

Produces a continuous supply of ultra high purity nitrogen gas from existing compressed air Eliminates the need for costly, dangerous, inconvenient nitrogen cylinders or dewars in the laboratory Extends ICP Analysis into far-uv range below 170 (nm) Compact design frees up valuable laboratory floor space Offers long term cost stability - uncontrollable vendor price increases, contract negotiations, long term commitments and tank rentals are no longer a concern ICP Spectrometer Model 76-98NA Products for Spectroscopy The Parker Balston 76-97NA and 76-98NA UHP s can produce 5-12 lpm of ultra high purity nitrogen gas. These systems are completely engineered to transform standard compressed air into 99.9999% of 99.995% pure nitrogen, exceeding the specification of UHP cylinder gas and dewars. Nitrogen is produced by utilizing a combination of state-of-the-art purification technologies and high efficiency filtration. Pressure swing absorption is utilized for the removal of 0 2, CO 2, and water vapor. A catalyst module is incorporated in the 76-98NA to oxidize hydrocarbons from the inlet air supply. The generators also have a combination of high efficiency prefilters and a 0.01 micron (absolute) membrane filter incorporated into their design. The Parker Balston UHP Nitrogen Generators are engineered and packaged in a laboratory cabinet to fit nearly any laboratory. The systems eliminate the needs for costly, inconvenient high pressure nitrogen cylinders or dewars. The 76-97NA and 76-98NA are ideal for ICP Purge gas applications. Applications Other applications include high flow GC carrier gas needs, DNA Synthesis and Sequencing Equipment, Mocon Moisture Analyzers, Circular Dichroism and Gel Permeation needs.

Products for Spectroscopy ICP Spectrometer Flow Table@ 99.9999% Purity Inlet Air Pressure Max Outlet Flow Max Outlet Pressure (psig) (lpm) (psig) Models 76-97NA and 76-98NA 120 5 83 110 5 73 100 5 63 90 4 62 80 4 51 70 2 50 60 2 42 Flow Table@ 99.995% Purity Inlet Air Pressure Max Outlet Flow Max Outlet Pressure (psig) (lpm) (psig) Models 76-97NA and 76-98NA 120 12 60 110 12 55 100 12 45 90 10 45 80 8 40 70 8 35 60 6 33 Principal Specifications Model 76-97NA/76-98NA Nitrogen Purity 99.995% and 99.9999% Max Nitrogen Output Pressure See Table CO Concentration < 1 ppm CO 2 Concentration < 1 ppm O 2 Concentration < 1 ppm H 2 O Concentration < 2 ppm Hydrocarbon Concentration (1) < 0.1 ppm Argon Concentration (2) 0.9% Min/Max Inlet Pressure 60 psig/120 psig Recommended Inlet Temperature 78 F (25 C) Ambient Operating Temperature 60 F-100 F (16 C-38 C) Average Air Consumption 3.0 scfm Inlet Connection 1/4 NPT Outlet Connection 1/8 NPT, convertible to 1/4 NPT Electrical Requirements (3, 4) 120 VAC/60 Hz Dimensions 41 h x 25 w x 25 d (104cm x 64cm x 64cm) Shipping Weight 500 lbs (227 kg) Ordering Information Model Numbers 76-97NA and 76-98NA 76-97-PM, 76-98-PM 76-97-DN2, 76-98-DN2 Description Ultra High Purity Preventive Maintenance Plan Notes: 1 Model 76-97NA does not remove hydrocarbons. 2 Purity specification for Nitrogen does not include Argon concentration. 3 Power Consumption is as follows: Model 76-97NA = 10 Watts, Model 76-98NA = 1 KW Extended Support with 24 Month Warranty 4 Refer to voltage appendix for electrical and plug configurations for outside North America.

Products for LC/MS & Evaporation High Flow s Lower cost...eliminates the need for costly gas cylinders Complete package with prefilters, final filters, and receiving tank Compact - frees up valuable floor space Eliminates unexpected shutdowns due to a bad or empty cylinder Hassle-free, easy to install, easy to operate Safe and reliable Parker Balston Dual Bed s Parker Balston Monobed Nitrogen Generators produce up to 99.95% pure, compressed nitrogen at dewpoints to -70 F (-21 C) from nearly any compressed air supply. The generators are designed to continually transform standard compressed air into nitrogen at safe, regulated pressures without operator attention. Parker Balston PSA Nitrogen Generators utilize a combination of filtration and pressure swing adsorption technologies. High efficiency prefiltration pretreats the compressed air to remove all contaminants down to 0.1 micron. Air entering the generator consists of 21% oxygen and 78% nitrogen. The gas separation process preferentially adsorbs oxygen over nitrogen using carbon molecular sieve (CMS). At high pressures the CMS has a greater affinity for oxygen, carbon dioxide, and water vapor than it does at low pressures. By raising and lowering the pressure within the CMS bed, all contaminants are captured and released, leaving the CMS unchanged. This process allows the nitrogen to pass through as a product gas at pressure. The depressurization phase of the CMS releases the absorbed oxygen and other contaminant gases to the atmosphere. The Parker Balston PSA Nitrogen Generators completely eliminate the inconvenience and the high costs of nitrogen Dewars and cylinders. There is no need to depend on outside vendors for your nitrogen gas supplies. The hassles of changing dangerous, high pressure cylinders, and interruption of gas supplies are completely eliminated. The Balston PSA s offer long term cost stability eliminating uncontrollable vendor price increases, contract negotiations, long term commitments, and tank rentals. Once the generator is installed, a continuous nitrogen supply of consistent purity is available within minutes from start-up.

High Flow s Installation consists of simply connecting a standard compressed air line to the inlet and connecting the outlet to a nitrogen line. Plug the electrical cord into a wall outlet, and the unit is ready for troublefree operation. This system is designed to operate 24 hours per day, 7 days per week. Once the system is operating, it requires little monitoring. The only maintenance involves changing the coalescing prefilter cartridges and final sterile air filter periodically. The PSA towers do not require any maintenance. An oxygen monitor to measure the oxygen concentration of the nitrogen stream is available as an option. An audible alarm signals high or low oxygen concentrations (determined by the application). The oxygen analyzer is supplied with alarm relay outputs which may be used to signal a remote alarm, open a backup supply or the process stream, or close the process flow for protection of downstream equipment or processes. Products for LC/MS & Evaporation Principal Specifications Model AGS200, AGS400 Nominal Conditions Feed Pressure 140 psig Temperature 80 F Ambient Pressure 1 Atm. Compressed Air Specifications Maximum Pressure 140 psig Temperature Range 60 F - 105 F Dewpoint 40 F pressure dewpoint or better Residual Oil Content Trace Particles <.01 micron Ambient Conditions Temperature 45 F-90 F Ambient Pressure Atmospheric Air Quality Clean air without contaminants Dimensions 28.5 L x 32.25 D x 76.25 H Weight 520 lbs (AGS200), 738 lbs (AGS400) Inlet 1/2 NPT Outlet 1/2 NPT Nitrogen Purity Flow Chart Models AGS200 and AGS400 Flow Rate (SCFH) Flow Rate (SCFH) Model 99.9%, 140 psig 99.99%, 140 psig AGS200 235 47 AGS400 470 94