True RMS Bench Multimeters 2831E and 5491B

Similar documents
DC Electronic Loads 8500 series

1.44 kw Programmable DC Power Supplies XLN Series

Multi-Range Programmable DC Power Supplies 9115 Series

No.1. Digital Multimeter RIGOL TECHNOLOGIES, INC.

High Power Programmable DC Power Supplies PVS Series

Multi-Range Programmable DC Power Supplies 9115 Series

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

2000 6½-Digit Multimeter

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Fluke 2638A Hydra Series III Data Acquisition System/ Digital Multimeter

How To Use A Cdm250 Digital Multimeter

User's Guide. True RMS Industrial Multimeter

Agilent 4338B Milliohm Meter

User's Guide. Integrating Sound Level Datalogger. Model Introduction

PICOTEST. M3500A 6.5 Digit Digital Multimeter. User s Manual

Panel Meters and Controllers Modular Panel Meter Type EDM 35

AutoRanging Digital MultiMeter

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Physical Specifications (Custom design available.)

DCS Series 1 kw, 1.2 kw, & 3 kw

Fluke 3000 FC Series Test Tools Technical Data

Voltech DC1000. Precision DC Bias Current Source

Model UT33A: OPERATING MANUAL Table of Contents (1)

User's Guide. Digital Sound Level Meter. Model

Dual Display Digital Multimeter

Manual Ranging MultiMeter

5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument

1. SAFETY INFORMATION

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Ground Resistance Clamp On Tester

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Rack mounted telephone- and leased line modem for industrial applications

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

SL Series AC and DC Electronic Loads

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz

DP800. Programmable Linear DC Power Supply RIGOL TECHNOLOGIES, INC.

Current Monitoring Kit QUICK START GUIDE

Power Meter Series 700

How To Use An Hm804X Series Of Power Supplies

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

10 Multimeter. Users Manual

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

BC Pro UPS System Standby UPS System

FREQUENCY RESPONSE ANALYZERS

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Temperature & Humidity SMS Alert Controller

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

4-Channel Thermometer / Datalogger

1 All safety instructions, warnings and operating instructions must be read first.

KONSTANTER SPL / SPL Programmable Electronic Load

FFT Spectrum Analyzers

Impedance 50 (75 connectors via adapters)

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

UT202A Operating Manual. Contents

DRM compatible RF Tuner Unit DRT1

User Guide. Model Insulation Tester / Megohmmeter

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

Uninterruptible Power Supply

PowerGem Pro Uninterruptible Power Supply

Interface Protocol v1.2

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Model #: SMART2200CRMXL

Power Electronics Testings

USB Smart Power Sensor

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Product Information Sheet UH36 Hi Pot Tester

Mobile Communications DC Sources W

Current Monitoring Kit

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

FREJA 300 Relay Testing System

T Substation Maintenance and Commissioning Test Equipment

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Dynatek 6080RS multimeter

LT-82 Stationary IR Transmitter

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Users Manual. ProcessMeter

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

R&S ZNBT8 Vector Network Analyzer Specifications

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Fluke Digital Multimeters Solutions for every need

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

SOUND LEVEL METER 94405

Loop Calibration and Maintenance

AVO410. Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter

User Guide. Temperature and Humidity Datalogger. Model 42280

Transcription:

Data Sheet True RMS Bench Multimeters and True RMS Bench Multimeters with Dual Display The B&K Precision models and are versatile and dependable bench multimeters suitable for applications in education, service and repair, and manufacturing requiring basic and reliable measurements. Additionally, these instruments enhance your productivity with built-in math functions and USB connectivity, features not found in other bench meters in this price category. Math operations Rel, Max/Min, dbm, db, %, and Hold provide educators with a convenient tool to teach basic math concepts. Model Count Digits 20,000 4 1/2 50,000 4 3/4 The and take typical multimeter measurements such as volts, ohms, and amps with great accuracy, stability, and basic VDC accuracy of 0.02% on the and 0.03% on the. The meters are also capable of measuring frequency, period, continuity, and performing diode tests. s can be taken at a maximum rate of 25 readings/sec with measurement rates selectable between slow, medium, and fast. Thes multimeters were designed for cost-conscious users requiring a basic and dependable meter with a broad range of features offered at a value price. Features & benefits Up to 50,000 count display resolution Basic VDC accuracy of up to 0.02% Dual display to indicate two measurements simultaneously AC + DC True RMS Up to 25 readings per second measurement rate AC volt and amp measurement over wide frequency range (ACV 100 khz/aci 20 khz) Limit mode for Pass/Fail testing Built-in math functions: Rel, Max/Min, dbm, db, %, Hold, Compare CATI (1000 V)/CATII (300 V) Protection USB (Virtual Com) and RS232* interface SCPI compatible * only Technical data subject to change B&K Precision Corp. 2012 w w w.bk precision.com

True RMS Bench Multimeters Models and Versatile tools Easy operation Dual Display Bright VFD display capable of displaying two measurements Soft rubber control buttons Sheathed safety banana input jacks These meters offer a dual display allowing multiple measurements to be conveniently displayed at once. The display values could be two different measurements or one measurement expressed in different units. For example, you can simultaneously read an AC voltage and a frequency value or a DC voltage value expressed in volts and in db. Limit Operation The limit operation lets you set and control the values that determine a HI / IN / LO status of subsequent measurements. The meter can be configured to emit an audible alarm when readings are outside of the configured limit. Durable rubber bumpers for added protection and ability to stack multiple instruments Rear panel USB communication interface Increase Productivity with PC Connectivity The and are programmable via USB and RS232 ( only) interface using industry standard SCPI commands. Users can control and configure the instrument from a remote PC and retrieve measurement results for further analysis. The meters can also be remotely controlled using application software (downloadable from the B&K website), which supports front panel emulation and data logging of measurement results. Front panel fuse compartment for easy fuse replacement Earth ground connection RS232 Interface () AC receptacle protected with 110/220V selectable line fuse Application software screenshot 2 w w w.bk prec ision.c om

Models and Specifications DC Voltage, and ± (% of reading + % of range), 23 C ± 5 C Typical Input Impedance 200.00 mv 10 µv 210.00 0.03%+0.08% (1) >10 MΩ 2.0000 V 100 µv 2.1000 0.03%+0.05% (1) >11.1 MΩ 20.000 V 1 mv 21.000 0.03%+0.06% >10.1 MΩ 200.00 V 10 mv 210.00 0.03%+0.06% 10 MΩ 1000.0 V 100 mv 1010.0 (2) 0.03%+0.06% 10 MΩ 500.00 mv 10 µv 510.00 0.02%+0.016% (1) >10 MΩ (1) under REL status (2) 1% over-range (1010 V) is readable at 1000 V range 5.0000 V 100 µv 5.1000 0.02%+0.008% (1) >11.1 MΩ 50.000 V 1 mv 51.000 0.02%+0.008% >10.1 MΩ 500.00 V 10 mv 510.00 0.02%+0.008% 10 MΩ 1000.0 V 100 mv 1010.0 (2) 0.02%+0.008% 10 MΩ AC Voltage, and ± (% of reading + % of range), 23 C ± 5 C (1) 23 C ± 5 C 20~50 Hz 50~20 khz 20~50 khz 50~100 khz 200.00 mv 10 µv 210.00 1.0%+0.2%) 0.5%+0.15% 1.8% + 0.25% 3.0% + 0.75% 2.0000 V 100 µv 2.1000 1.0%+0.2%) 0.4%+0.05% 1.5% + 0.1% 3.0% + 0.25% 20.000 V 1 mv 21.000 1.0%+0.2% 0.4%+0.05% 1.5% + 0.1% 3.0% + 0.25% 200.00 V 10 mv 210.00 ---- 0.8%+0.075% 1.5% + 0.1% 3.0% + 0.25% 750.0 V 100 mv 757.5(3) ---- 0.8%+0.075% 1.5% + 0.1% (2) 3.0% + 0.25% (2) 500.00 mv 10 µv 510.00 1.0%+0.08%) 0.5%+0.06% 1.5% + 0.1% 3.0% + 0.3% 5.0000 V 100 µv 5.1000 1.0%+0.08%) 0.35%+0.02% 1% + 0.04% 3.0% + 0.1% 50.000 V 1 mv 51.000 1.0%+0.08% 0.35%+0.02% 1% + 0.04% 3.0% + 0.1% 500.00 V 10 mv 510.00 ---- 0.5%+0.03% 1% + 0.04% 3.0% + 0.1% 750.0 V 100 mv 757.5(3) ---- 0.5%+0.03% 1% + 0.04% (2) 3.0% + 0.1% (2) Max. crest factor: 3.0 at full scale (1) Specifications are for sine wave inputs >5% of range. (2) Limit at 40 khz or 3 107 Volt-Hz for 750 V range (3) 1% over-range (757.50V) is readable at 750V range DC Current, and ± (% of reading + % of range), 23 C ± 5 C Burden Voltage(1) & Shunt Resistor 2.0000 ma 0.1 µa 2.1000 0.08%+0.025% (2) <0.3 V / 100 Ω 20.000 ma 1 µa 21.000 0.08%+0.02% (2) <0.04 V / 1 Ω 200.00 ma 10 µa 210.00 0.08%+0.02% <0.3 V / 1 Ω 2.0000 A 100 µa 2.1000 0.3%+0.025% <0.05 V / 10 mω 20.000 A 1 ma 21.000 (3) 0.3%+0.025% <0.6 V / 10 mω 5.0000 ma 0.1 µa 5.1000 0.05%+0.01% (2) <0.6 V / 100 Ω 50.000 ma 1 µa 51.000 0.05%+0.008% (2) <0.06 V / 1 Ω 500.00 ma 10 µa 510.00 0.05%+0.008% <0.6 V / 1 Ω 5.0000 A 100 µa 5.1000 0.25%+0.01% <0.1 V / 10 mω 20.000 A 1 ma 21.000 (3) 0.25%+0.01% <0.6 V / 10 mω (1) Typical voltage across the input terminals at full scale reading. (2) Use REL function (3) In 20 A range, >10~20 ADC is readable for 20 seconds maximum 3 www.bk precision.com

Models and Specifications (cont.) AC Current (True RMS, AC Coupling), and ± (% of reading + % of range), 23 C ± 5 C Max. crest factor: 3.0 at full scale (1) 23 C ± 5 C 20~50 Hz 50~2 khz 2~20 khz 2.0000 ma 0.1 µa 2.1000 1.5%+0.5% 0.5%+0.3% 2%+0.5% 20.000 ma 10 µa 21.000 1.5%+0.5% 0.5%+0.3% 2%+0.38% 200.00 m A 100 µa 210.00 1.5%+0.5% 0.5%+0.3% 2%+0.38% 2.0000 A 1 ma 2.1000 2.0%+0.5% 0.5%+0.3% ---- 20.000 A 10 ma 21.000 (2) 2.0%+0.5% 0.5%+0.3% ---- 5.0000 ma 0.1 µa 5.1000 1.5%+0.16% 0.5%+0.08% 2%+0.16% 50.000 ma 10 µa 51.000 1.5%+0.16% 0.5%+0.08% 2%+0.12% 500.00 m A 100 µa 510.00 1.5%+0.16% 0.5%+0.08% 2%+0.12% 5.0000 A 1 ma 5.1000 2.0%+0.16% 0.5%+0.1% ---- 20.000 A 10 ma 21.000 (2) 2.0%+0.16% 0.5%+0.1% ---- (1) Specifications are for sine wave inputs >5% of range. (2) In 20 A range,>10~20 A AC is readable for 20 seconds maximum Resistance, and ± (% of reading + % of range), 23 C ± 5 C Rate (1) 200.00 Ω 10 mω 210.00 0.5 ma 0.10%+0.05% (2) 2.0000 kω 100 mω 2.1000 0.45 ma 0.10%+0.025% (2) 20.000 kω 1 Ω 21.000 45 µa 0.10%+0.025% (2) 200.00 kω 10 Ω 210.00 4.5 µa 0.10%+0.025% 2.0000 MΩ 100 Ω 2.1000 450 na 0.15%+0.025% 20.000 MΩ 1 kω 21.000 45 na 0.3%+0.05% 500.00 Ω 10 mω 510.00 0.5 ma 0.10%+0.01% (2) 5.0000 kω 100 mω 5.1000 0.45 ma 0.10%+0.008% (2) 50.000 kω 1 Ω 51.000 45 µa 0.10%+0.008% (2) 500.00 kω 10 Ω 510.00 4.5 µa 0.10%+0.008% 5.0000 MΩ 100 Ω 5.1000 450 na 0.15%+0.008% 50.000 MΩ 1 kω 51.000 45 na 0.3%+0.01% (1) In order to eliminate the noise interference, which might be induced to the test leads, it is recommended to use a shielded test cable for measuring resistance above 100 kω. (2) Using REL function Continuity, and ± (% of reading + % of range), 23 C ± 5 C 23 ºC ± 5ºC 200 Ω 100 mω 999.9 0.5 ma 0.1%+0.1% 500 Ω 100 mω 999.9 0.5 ma 0.1%+0.04% Open circuit voltage: <5.5 VDC : around 0.5 ma DC 4 www.bk precision.com

Models and Specifications (cont.) Diode, and ± (% of reading + % of range), 23 C ± 5 C Med 2.0000 V 100 µv 2.3000 V 0.5 ma (Approx.), and ± (% of reading + % of range), 23 C ± 5 C ACV 200 mv (500 mv*) to 750V * Model Best Input Sensitivity (Sine Wave) 10 Hz 100 µhz 9.9999 0.05%+0.02% 200 mv rms 10~100 Hz 1 mhz 99.999 0.01%+0.02% 300 mv rms 100~100 khz 10 mhz 999.99 0.01%+0.008% 300 mv rms 100k~1 MHz 10 Hz 999.99 0.01%+0.008% 500 mv rms Period, and ± (% of reading + % of range), 23 C ± 5 C ACV 200 mv (500 mv*) to 750V * Model Best Input Sensitivity (Sine Wave) 1~10 µs 0.1 ns 9.9999 0.01%+0.008% 500 mv rms 10 µs~10 ms 1 ns 9.9999 0.01%+0.008% 300 mv rms 10 ms~100 ms 1 µs 99.999 0.01%+0.02% 300 mv rms 100 ms 10 µs 199.99 0.05%+0.02% 200 mv rms General Power Supply 110/220 V ± 10%, 50/60 Hz ± 5% Power Consumption 10VA Operating Environment 0 C to 40 C, 90 %RH Storage Environment Warm-up Dimensions (W H D) Net Weight -40 C to 70 C at least 30 minutes Accessories Included: Test leads, Power cord, Spare fuse, Operation Manual, Calibration certificate and test report 225 mm 100 mm 355 mm 8.85 x 3.93 x 13.97 2.5 kg 5.51 lbs One Year Warranty (), Three Year Warranty () 5 v052411 www.bk precision.com