MCE380: Measurements and Instrumentation Lab. Chapter 6: Temperature Measurements

Similar documents
Chapter 18 Temperature, Heat, and the First Law of Thermodynamics. Problems: 8, 11, 13, 17, 21, 27, 29, 37, 39, 41, 47, 51, 57

KINETIC THEORY AND THERMODYNAMICS

RTD and thermocouple circuits, with millivolt calculations

Conversion of Thermocouple Voltage to Temperature

IC Temperature Sensor Provides Thermocouple Cold-Junction Compensation

HOW ACCURATE ARE THOSE THERMOCOUPLES?

Basic RTD Measurements. Basics of Resistance Temperature Detectors

Evolution of the Thermometer

The Fundamentals of Thermoelectrics

THE STRAIN GAGE PRESSURE TRANSDUCER

Evaluation copy. Build a Temperature Sensor. Project PROJECT DESIGN REQUIREMENTS

Microcontroller to Sensor Interfacing Techniques

MCE380: Measurements and Instrumentation Lab. Chapter 9: Force, Torque and Strain Measurements

APPLICATION NOTES DEFINITIONS NTC Thermistor 101

CALIBRATION OF A THERMISTOR THERMOMETER (version = fall 2001)

Measuring Temperature withthermistors a Tutorial David Potter

Temperature Sensors. Resistance Temperature Detectors (RTDs) Thermistors IC Temperature Sensors

2. Room temperature: C. Kelvin. 2. Room temperature:

Measuring temperature with Resistance Temperature Detectors (RTD) (e.g., Pt100) and thermocouples

1. The Kinetic Theory of Matter states that all matter is composed of atoms and molecules that are in a constant state of constant random motion

Name: Class: Date: 10. Some substances, when exposed to visible light, absorb more energy as heat than other substances absorb.

How to calibrate an RTD or Platinum Resistance Thermometer (PRT)

Practical Temperature Measurements. Application Note 290

Using NTC Temperature Sensors Integrated into Power Modules

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

Thermistor Basics. Application Note AN-TC11 Rev. A. May, 2013 Page 1 WHAT IS A THERMISTOR?

Experiment 5. Strain Gage Measurements

Temperature Accuracy of Thermistors and RTDs Application Notes

WHITE PAPER How to Prevent Temperature Measurement Errors When Installing Thermocouple Sensors and Transmitters

PC BASED PID TEMPERATURE CONTROLLER

(Issued 1 Dec. 1965) CRD-C METHOD OF TEST FOR THERMAL CONDUCTIVITY OF LIGHTWEIGHT INSULATING CONCRETE 1

IDEAL AND NON-IDEAL GASES

Module 1, Lesson 3 Temperature vs. resistance characteristics of a thermistor. Teacher. 45 minutes

Soil Suction. Total Suction

R&D Engineer. equipment. the power

Instrumentation for Process Automation. Dr Jie Zhang Department of Chemical & Process Engineering, University of Newcastle (Started 6 February 2002)

Environmental Monitoring with Sensors: Hands-on Exercise

Objectives 200 CHAPTER 4 RESISTANCE

Experiment 4: Sensor Bridge Circuits (tbc 1/11/2007, revised 2/20/2007, 2/28/2007) I. Introduction. From Voltage Dividers to Wheatstone Bridges

Physics 3330 Experiment #2 Fall DC techniques, dividers, and bridges R 2 =(1-S)R P R 1 =SR P. R P =10kΩ 10-turn pot.

USB TC-08. Temperature Logger. User's Guide. usbtc08.en r7 Copyright Pico Technology Limited. All rights reserved.

Temperature. Temperature

# 2. Selecting and Using Thermistors for Temperature Control

Kinetic Theory & Ideal Gas

Low Cost, Precision IC Temperature Transducer AD592*

Thermodynamics AP Physics B. Multiple Choice Questions

16. Industrial Platinum Resistance Thermometers

Measuring Silicon and Germanium Band Gaps using Diode Thermometers

Practical Application of Industrial Fiber Optic Sensing Systems

Monolithic Thermocouple Amplifiers with Cold Junction Compensation AD594/AD595

Chemistry 13: States of Matter

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

Phys222 W11 Quiz 1: Chapters Keys. Name:

APPLICATION NOTES OF SIGNAL ISOLATORS

Gas Laws. Heat and Temperature

Series and Parallel Circuits

Experiment 12E LIQUID-VAPOR EQUILIBRIUM OF WATER 1

ADC-20/ADC-24 Terminal Board. User Guide DO117-5

Of all the physical properties, it is temperature, which is being measured most often.

Vaporization of Liquid Nitrogen

When the fluid velocity is zero, called the hydrostatic condition, the pressure variation is due only to the weight of the fluid.

Advances in Thermal Dispersion Mass Flow Meter Accuracy

EXPERIMENT 7 OHM S LAW, RESISTORS IN SERIES AND PARALLEL

Electronic Instrumentation

ENERGY TRANSFER SYSTEMS AND THEIR DYNAMIC ANALYSIS

E/M Experiment: Electrons in a Magnetic Field.

STUDY MATERIAL FOR CLASS Physics- CURRENT ELECTRICITY. The flow of electric charges in a particular direction constitutes electric current.

Temperature Notes Kelvin, Celsius, Fahrenheit Write notes, put in por7olio. Study. Read over notes daily.

HTM2500LF Temperature and Relative Humidity Module

How to measure absolute pressure using piezoresistive sensing elements

Two-Terminal IC Temperature Transducer AD590

7. What is the current in a circuit if 15 coulombs of electric charge move past a given point in 3 seconds? (1) 5 A (3) 18 A (2) 12 A (4) 45 A

SCXI CHANNEL ISOTHERMAL TERMINAL BLOCK

UNIT (1) MEASUREMENTS IN CHEMISTRY

More Op-Amp Circuits; Temperature Sensing

Chapter 10 Temperature and Heat

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

Weight Measurement Technology

Statistical Mechanics, Kinetic Theory Ideal Gas. 8.01t Nov 22, 2004

Errors Due to Shared Leadwires in Parallel Strain Gage Circuits

THEORY AND APPLICATION OF KURZ THERMAL CONVECTION MASS FLOW METERS INSTRUMENTS

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

AN-225 IC Temperature Sensor Provides Thermocouple Cold-Junction

LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description

LM135-LM235-LM335. Precision temperature sensors. Features. Description

THERMAL RADIATION (THERM)

Errors Related to Cable Resistance Imbalance in Three Wire RTDs

Temperature Calibration; Depths of Immersion

Calibrating DC Shunts: Techniques and Uncertainties

HEAT UNIT 1.1 KINETIC THEORY OF GASES Introduction Postulates of Kinetic Theory of Gases

TEMPERATURE 2008, 2004, 1990 by David A. Katz. All rights reserved.

Unit 7: Electrical devices LO2: Understand electrical sensors and actuators Sensors temperature the thermistor

64 Series HEAT FLUX TRANSDUCERS and INFRARED RADIOMETERS for the DIRECT MEASUREMENT OF HEAT TRANSFER RATES

Calibration and Use of a Strain-Gage-Instrumented Beam: Density Determination and Weight-Flow-Rate Measurement

There is no such thing as heat energy

Chapter 10: Temperature and Heat

Fundamentals of Mass Flow Control

AC Transport constant current vs. low impedance modes

Cold-Junction-Compensated K-Thermocoupleto-Digital Converter (0 C to C)

Transcription:

MCE380: Measurements and Instrumentation Lab Chapter 6: Temperature Measurements Topics: Temperature Scales Ideal Gas Thermometers Temperature Measurement by Mechanical Effects Temperature Measurement by Electrical Effects Holman, Ch. 8; Copies from Doebelin in ECR Cleveland State University Mechanical Engineering Hanz Richter, PhD MCE380 p.1/24 Thermodynamic Temperature Scale Before the discovery of the absolute zero (Lord Kelvin, 1848), temperature was thought to be a relative quantity, with a value dependent of the scale used. Kelvin established the existence of a true zero temperature correspoding to a state of minimum vibrational energy of molecules. The International Practical Temperature Scale was first established in 1968. It provided primary and secondary points that attach a value to certain states of selected substances. For example, it assigned -259.194 C to the triple point of Hydrogen at normalized atmospheric pressure. See Holman, Tables 2.1 thru 2.4 for more recent definitions. MCE380 p.2/24

Celsius and Fahrenheit Scales The Celsius and Fahrenheit scales match the freezing and boiling temperatures of water given by the thermodynamic scale. The Celsius scale divides the freezing-to-boiling range in 100 equal parts, while the Fahrenheit scale uses 180 divisions. For this reason F = 180 100 C = 9 5 C When the Celsius scale is shifted by +273.16 or the Fahrenheit scale by +459.69, the resulting scales are the Kelvin and Rankine scales, respectively. These scales approximate the waypoints of the thermodynamic scale closely. The conversion btw F and C is well-known: F = 32 + 9 5 C MCE380 p.3/24 The Ideal Gas Thermometer The ideal gas thermometer is based in the equation of state for the ideal gas: pv = mrt A fixed-volume canister containing a gas of known mass and R constant is used as the temperature-sensing element. The pressure of the gas is read using a pressure gage. Fixed Vol. V Measured Temp. T Pressure gage Tube MCE380 p.4/24

The Ideal Gas Thermometer Although it is possible to calculate T knowing p, m and R, there could be uncertainty in the values of m and R. Instead, we recognize that under constant volume and mass we must have T 1 T 2 = p 1 p 2 So making a calibration measurement using a known T 2 = T ref and reading the corresponding p 2 = p ref, we have p T = T ref p ref Thermometers of this type can read temperatures approaching 1 K. MCE380 p.5/24 Mechanical Measurement of Temperature Thermal expansion is used as the working principle of various temperature-measuring devices. Mercury-in-glass thermometers can be made to read temperatures above -37.8 C (freezing point of Mercury) up to 500 C. Higher temperatures require filling the capillary tube with a gas to increase the pressure and therefore the boiling point. The glass may expand noticeably, shifting the scale relative to the mercury. High-accuracy thermometers (±0.05 C) have a mark designating the proper immersion level. MCE380 p.6/24

Bimetallic Strips The bimetallic strip is a widely-used device. It is made by bonding two strips of materials having different thermal expansion coefficients. The bond is made at a reference temperature, with both strips having equal length. r θ r t y d=y sin θ L When the temperature changes, the materials experience different elongations. Since they must stay bonded, a curved shape is adopted. MCE380 p.7/24 Bimetallic Strip Calculations The radius of curvature can be calculated with r = t{3(1 + m)2 + (1 + mn)[m 2 + 1 mn ]} 6(α 2 α 1 )(T T 0 )(1 + m 2 ) where t is the total thickness; m is the thickness ratio btw. low- and high-expansion materials; n is the ratio of elastic moduli btw. low- and high-expansion materials; α 1 and α 2 are the lower and higher coefficients of expansion ( C 1 ); T is the measured temperature and T 0 is the initial bonding temperature (both in C). The deflection can be calculated as shown in the figure (see Holman Ex. 8.1). MCE380 p.8/24

Example Solve Prob. 8.5 from Holman. MCE380 p.9/24 Temp. Measurement by Electrical Effects The Resistance Temperature Detector (or RTD) is based on changes in resistivity with temperature. The temperature coefficient of resistance is defined as α = R 2 R 1 R 1 (T 2 T 1 ) where R 1 and R 2 are the resistances of the material at temperatures T 1 and T 2. See Holman, Table 8.2 for values. The above linear relationship is valid for narrow ranges only. A quadratic fit of the form R = R 0 (1 + at + bt 2 ) is frequently used for wider ranges. The values of a and b must be determined from calibration experiments. These are known as Callender coefficients. RTD s usually have platinum sensing elements (the one used in the lab is of this type). The platinum is coated with another material to protect against environmental effects and mechanical damage. MCE380 p.10/24

RTD Signal Conditioning Nonlinearity, connecting wire resistance and self-heating effects are the main sources of error. Nonlinearity arises from using the RTD over wide temperature ranges, where the quadratic equation applies. The length and gage of the connecting wires is uncertain. Special bridge circuits (see Holman Fig. 8.7) are used to compensate for connecting leads. The RTD is subject to heating according to the i 2 R power law. This can produce false readings. The signal conditioner used in the lab contains specialized circuits that guarantee linearity over the whole range of operation, in addition to amplifying and biasing the output to desired levels. MCE380 p.11/24 Thermistors As explained earlier, a thermistor is a semiconductor that decreases its resistivity with increasing temperature. This is the opposite behavior of metals. The resistance-temperature behavior is exponential: R = R 0 e β( 1 T 1 T 0 ) where R 0 is the resistance at a reference temperature T 0 and β is a constant that varies from device to device. Observe Fig. 8.8 in Holman (compare to platinum). Think about a way to obtain β if R 0, T 0 and data points for R and T are available experimentally. MCE380 p.12/24

Peltier-Seebeck Effect: Modern Explanation for Thermocou Old notion: When two distinct metals are joined together, a voltage appears between endpoints. New notion (mid-90 s): A temperature gradient in a material gives rise to a voltage. We can observe this voltage even in a single material having a thermal gradient. The absolute Seebeck coefficient is defined as: σ(t) = de σ dt where E σ is the voltage. Note that σ(t) is not a constant, but a function of temperature. Integrating btw T 1 and T 2 : E σ = T2 T 1 σ(t)dt = T2 0 σ(t)dt T1 0 σ(t)dt = E σ (T 2 ) E σ (T 1 ) The generated voltage depends only on the values of E σ at the endpoints. MCE380 p.13/24 Relative Seebeck coefficient Distinct metals will have different values of σ(t). Thus, in a back-to-back arrangement (a thermocouple), the two voltages must be subtracted: E = T2 T 1 σ A (T)dT T2 T 1 σ A (T)dT = T2 T 1 σ A (T) σ B (T)dT = T2 T 1 σ AB (T)dT Junction T1 Material A i Material B A B T2 σ AB is the relative Seebeck coefficient. Note that one of the temperatures must be known in order to find the other from measured voltage. MCE380 p.14/24

Thomson and Peltier (Side-) Effects If we pass a current through a single material, a thermal gradient is estabished. This is called the Thomson effect. If two distinct materials are put in contact and a current is established, there will be heat transfer from one of the materials to the other. One materials heats up, while the other cools down. This phenomenon is known as the Peltier effect. Any real thermocouple connected to a measuring device will exhibit a combination of the three effects. The Peltier-Seebeck effect is the one that determines the measured voltage for the most part, if the current flowing through the junction is kept small. Recall the concept of input impedance of a meter: it must be high to keep the current small! MCE380 p.15/24 Issues with connecting cables The connection between the metals and the cables creates two additional junctions subject to the Peltier-Seebeck effect. The total output voltage will then depend on the temperature of these extra junctions, which are not intended to act as temperature sensors and only introduce uncertainty. A reference temperature will be required at the extra junctions. Two thermocouple interconnection laws will help us analyze various thermocouple circuits. MCE380 p.16/24

Thermocouple Laws Law of intermediate metals: If a third metal is inserted as shown below, the net voltage of the circuit is unaffected, provided the insert is kept at a uniform temperature (T c = T d ). Law of intermediate temperatures: If two junctions are created and operated at different temperatures, the generated voltages follow an additive law as shown below. Material (1) A Tc C Td D Material (2) B T1 T2 T2 T3 T1 T3 E1 E2 E3=E1+E2 MCE380 p.17/24 Thermocouple Laws Independence of intermediate temperatures: The voltage generated by each branch of the thermocouple is independent of intermediate temperatures if each material is homogeneous. This law is an immediate consequence of the formula we saw earlier: E σ = E σ (T 2 ) E σ (T 1 ) MCE380 p.18/24

Traditional Temperature Referencing Method At least two junctions are created by connecting the ends of the metals to instrumentation cables. These junctions can be at the same or at different temperatures, leading to the methods shown below. Note that the second arrangement works because of the law of independence of intermediate temperatures for homogeneous materials. T Constantan Iron Copper Copper Voltmeter Ice Water Constantan T Iron Constantan Voltmeter Ice Water MCE380 p.19/24 Standard Thermoelectric Potentials Standardized voltage data for cold junctions referenced at 0 C is available for various material pairs. T type: Copper-Constantan E type: Chromel-Constantan J type: Iron-Constantan K type: Chromel-Alumel S type: Platinum-Platinum Rhodium N type: Nicosil-Nisil Observe Table 8.3a in Holman for temperature ranges and thermoelectric voltages. A J-type thermocouple should generate -6.5 µv at -150 C and +69 µv at +1200 C. The voltage-temperature data follows a power law E = AT + 1 2 BT 2 + 1 3 CT 3 MCE380 p.20/24

High-Order Polynomial Fit NIST has published coefficient data and accuracies for several thermocouple materials. A 9th-order polynomial has been used to fit the temperature-voltage data: T = a 0 + a 1 x + a 2 x 2 +... + a 9 x 9 where x is in volts (reference junction at 0 C) and T is in C. An excerpt of the NIST data appears in Holman, Table 8.5. The sensitivity in volts per degree may be obtained by differentiation of the cubic polynomial or by differentiation of the 9th-order polynomial and reciprocation. MCE380 p.21/24 Practical Cold Junction Compensation It is inconvenient to keep the connecting junctions at the reference temperature at all times. Two methods are used in practice. Both use an additional temperature sensor (thermistor or RTD) to measure the temperature of the connection junctions. In hardware compensation, a specially-designed circuit utilizes the thermistor voltage to cancel out the effect of connecting junction temperature. In software compensation, the thermistor voltage is digitized and a microprocessor calculates the true temperature. The advantage of this method is that the characteristics of the thermocouple being used are not hardwired in the compensating circuit, and can thus be re-programmed. MCE380 p.22/24

Basic Calculation The voltage generated by a thermocouple depends on the difference between the sensing and connecting junction temperatures. Usually, both binding posts at the voltage-measuring instrument are at the same temperature. If the connecting junction were at 0 C, we would read the generated voltage directly from Table 8.3a. When the connecting junction is at a different temperature, the intermediate temperature law tells us that we must subtract the voltage generated by the connecting junction from that generated by the sensing junction. Examine Example 8.4 and then solve Prob. 8.12. MCE380 p.23/24 Thermopiles Thermopiles are series connections of the same thermocouple pairs (see Fig. 8.19). Thermopiles are used to obtain larger voltage readouts (more sensitivity). The net voltage will depend on the difference of temperatures between sensing and connecting junction and will obey the law of intermediate temperatures. Examine Example 8.5 (first part). MCE380 p.24/24