LITE II 650/850 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

Similar documents
User s Manual AURORA 1.2K/2.2K

How To Use A Power Supply Unit (Upu)

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Line Interactive UPS

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Online UPS. PowerWalker VFI 1000R/1U

Line Interactive UPS. Cheerups. Cheerups. Installation and Operation Manual. An ISO 9001:2008 Company. C he erup s

Powerware 5110 UPS User s manual

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

350, 500, 650 and 1000 MODELS

User s Manual Before using the inverter, you need to read and save the safety instructions.

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

User Manual 1K/2K/3K Online UPS

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

3000W Power Inverter

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

How To Use A Power Supply Unit (Upland)

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

EKOS Cart. Instructions for Use

USER MANUAL Online UPS 1K/2K/3K Rack

Installation and Operation Back-UPS 1250, 1300, 1500

HP UPS R1500 Generation 3

USER MANUAL Online UPS 1K/2K/3K

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

10000HXL31/15000HXL31/20000HXL31

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

SPL 2-00/-01 OPERATION INSTRUCTIONS

Model #: SMART2200CRMXL

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

Home Solar Kit Owner s Manual. Model: HS

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

VLT Series 300 Watt True Sine Wave Inverter

User Manual HomeGrid 3000 Solar Generator

TIG INVERTER INSTRUCTION MANUAL

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Installation and Operating Instructions (for chargers shown below)

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

CHARGING SYSTEMS INTERNATIONAL

AutoRanging Digital MultiMeter

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

Back-UPS Pro 1300/1500 Installation and Operation

Battery Power Inverters

Dehumidifier Users manual. For Models: DH45S DH65S

Uninterruptible Power Supply

400 Amp Rechargeable Jump Start System RAC-HP082

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

esata External Storage

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

Installation and Operating Instructions (for chargers shown below)

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Residential Gateway (RG) Battery Backup

12. Inspection and Maintenance

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

Advantium 2 Plus Alarm

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

How To Use A Cdm250 Digital Multimeter

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

AC Power For Business-Critical Continuity. Liebert PSI. User Manual 750/1000/1500/2200/3000, 230VAC

ekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.

Battery charger. Art.no Model CB5-5L-BS1 ENGLISH SVENSKA NORSK SUOMI. Ver Original instructions

User Manual. English. APC Smart-UPS VA 120/230 Vac VA 100/120/208/230 Vac. 2U Rack Mount Uninterruptible Power Supply

Li Battery Pack & Charger Safety & Operating Instructions

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

BITMAIN. APW PSU Series User Guide

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

Manual for Fire Suppression & Methane Detection System

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

UPS VA User s Manual

Microwave Oven. Warning: a) This oven is not for commercial use. b) Don't open the cover of the machine except professional person.

Home Solar Kit Owner s Manual. Model: HS

Digital Photo Picture Frame. Operation Manual

Transcription:

LITE II 650/850 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

This UPS is specially designed for Personal Computers with multi-functions. lts light weight, compact design perfect fits to the limited working environment. The line of UPS is equipped with boost and buck AVR to stabilize input voltage range. lt is also built-in with DC start function. This function enables the UPS to be started up without AC power supplied. The main features of UPS are listed below: Compact size, light weight. Microprocessor control guarantees high reliability. Equipped with Boost and Buck AVR. Green Power Function for energy saving. DC Start Function. (Cold Start) Provides AC Overload protection. INTRODUCTION Front Panel Lite II 650 Lite II 850 Back Panel 1 3 2 5 4 1. Smart On/Off Button 2. AC Mode: Green Lighting Battery Mode: Orange Flashing Fault: Red Lighting 3. AC Input 4. Output Receptacles 5. Circuit Breaker

SMART BUTTON TECHNOLOGY ALARM SILENCE FUNCTION Smart On/Off Button Technology (Alarm Silence Function) Press the smart button for minimum 1 second to turn the UPS unit on. If mains is cut off when UPS is working, UPS starts working in battery mode and gives audible alarm. If you press smart button once, UPS audible alarm stops (Alarm Silence Function). If the smart button is pressed once again, the alarm starts again. After UPS alarm is silenced, when battery capacity drops to a critical level the audible alarm starts automatically again and cannot be silenced. Press the smart button until the LED turn into red then remove your finger to shut down the UPS unit. 1. Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping. If any damage is discovered, repack the unit and return it to the place of purchase. 2. Charging This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Turn on the UPS, Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 6 hours with no load (no electrical devices such as computers, monitors, etc.) connected. Green LED flashes while UPS charging. Smart On/Off Button

DON T CONNECT A LAZER PRINTER TO THE UPS UNIT 3. Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity is high. On the other hand, place the UPS away from the monitor at least 20 cm to avoid interference. 4. Connection Plug the UPS into a 2-pole, 3-wire grounded receptacle. Then connect one computer-related device into each of the power receptacles supplied on the back of the UPS. THIS MAY CAUSE THE DAMAGE OF THE UNIT 5. Turn On/Off Press the smart button for minimum 1 second to turn the UPS unit on. Press the smart button until the LED turn into red then remove your finger to shut down the UPS unit. Smart Button 6. DC Start All Series are equipped with DC Start (Cold Start). To start the UPS when AC utility power is not available, simply press the smart button for minimum 1 second.

SAFETY - WARNING This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Only factory service personnel may perform repairs. Internal battery voltage is 12Vdc. Sealed, lead-acid, 6 cells battery. Connection to any other type of receptacle other than a two-pole, three-wire grounded receptacle may result in shock hazard as well as violate local electrical codes. In the event of an emergency, press the Smart On/Off Button for 4 seconds and disconnect the power cord from the AC power supply to properly disable the UPS. Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit. This unit intended for installationina controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity. Do not plug the UPS input into its own output. Do not attach a power strip or surge suppressor to the UPS. Do not attach to non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, vacuum cleaners, lazer printers or washing machine. To reduce the risk of overheating the UPS, do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces. Unplug the UPS prior to cleaning and do not use liquid or spray detergent. Do not dispose of batteries in a fire as they may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. lt may be toxic. Attention, hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary. Servicing of batteries should be performed by authorized personnel. Keep unauthorized personnel away from batteries. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries: 1) Remove watches, rings, or other metal objects from the hands. 2) Use tools with insulated handles. 3) Wear rubber gloves and boots. 4) Do not lay tools or metal parts on top of batteries. 5) Disconnect charging source prior to connecting or disconnecting batteries terminals. When replacing batteries, replace with the same number and type of sealed lead-acid battery. The maximum ambient temperature raling is 40 C. This pluggable type A equipment with battery already installed by the supplier is operatar installable and may be operated by laymen. During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5 ma. The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible.

TROUBLE SHOOTING Use the table below to solve minor problems. Problem No LED display on the front panel Possible Cause Low battery Battery fault Solutions Charge the UPS at least 6 hours Replace the battery with the same type of battery (Please see Safety-Warning page) The UPS is not turned on Press the On/Off button at least 1 second to turn on the UPS Alarm continuously sounds when the mains is normal The UPS is overload Remove some loads first. Before reconnecting equipment, please verify that the load matches the UPS capability specified in the specs. (Please see Technical Specification table) When power fails, back-up time is shorten The UPS is overload Battery voltage is too low Remove some critical load Charge the UPS at least 6 hours Battery defect. It might be due to high temperature operation environment, or improper operation to battery. Replace the battery with the same type of battery (Please see Safety-Warning page) The mains is normal but LED color in red is flashing Power cord is loose Reconnect the power cord properly, if the problem can t be solved please consult nearest technical service

TECHNICAL SPECIFICATIONS MODEL Lite II 650 VA Lite II 850 VA Capacity INPUT Voltage Voltage Range OUTPUT Voltage Regulation Transfer Time Waveform BATTERY Type & Number Charging Time PHYSICAL Dimensions (DxWxH) Net Weight (kg) ENVIRONMENT Humidity Noise Level 650 VA / 360 W 850 VA / 480 W 220/230/240 VAC 162-265 VAC ±10% Typical 2-6 ms, 10 ms max. Simulated sine wave 1 X 12V 7AH 1 X 12V 9AH 4-6 hours recover to 90% capacity 322 x 122 x 160 mm 4.5 kg 5.1 kg 0-40 C 0-90% (Non-condensing) <40 db Green Energy tuncmatik products offer energy savings of up to 30%, helping you consume less of natural resources.

LITE II 650/850 VA UNINTERRUPTIBLE POWER SUPPLY UPS nqa ISO 9001 Registered nqa nqa ISO 14001 OHSAS 18001 Registered Registered