NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

Similar documents
Top Commercial / Residential Electrical Requirements *

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

Questions and Answers for Heating and A/C Contractors

BRANCH CIRCUIT AND FEEDER REQUIREMENTS

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Ontario Electrical Safety Code 25 th Edition/ 2012

2011 NEC Summary of Changes. Chapter Summary of Changes. Article Section Summary of Change

Mike Holt s Illustrated Guide to. Rule , Articles 445, 700, 701, and 702. Based on the 2011 NEC

Errata NFPA 70. Proposed 2014 Edition

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

PALM BEACH COUNTY AMENDMENTS TO THE NATIONAL ELECTRICAL CODE, 1999 EDITION

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

NEC 2014 Code Changes

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

INSPECTION GUDELINES

Electrical Grounding. Appendix C

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

Title: Grounding and Bonding Rev-01

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Electrical Contractors. and the. New Jersey. Rehabilitation Code

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

Requirements for Electrical Installations

Residential Electrical System Aging Research Project. Dave Dini Sr. Research Engineer Underwriters Laboratories

ELECTRICAL INSPECTION BULLETIN (Effective )

Siemens STEP 2000 Course Basics of Electrical Products

INTRODUCTION ARC FLASH PROTECTION AND SAFETY MEASURES. September 2010

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

2011 National Electrical Code Changes

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

Residential Electrical Inspection. Checklist

8146/5 Series Breaker Panelboards

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

Residential Electrical Inspection Checklist

Entrances to and from Electrical Equipment Rooms

IMPLEMENTING THE NEW ELECTRICAL SAFETY REQUIREMENTS

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin?

Residential Electrical Inspection. Checklist

BASIC NEC CODE RULES AND DESIGN PRACTICE

Understanding Arc Flash

2011 National Electrical Code Questions & Answers

The U.S. Department of Labor projects that electrician careers will grow to 698,200 by 2022.

ELECTRICIAN TRADE REGULATION

ARC FLASH HAZARD OVERVIEW. Presented August 13, 2015 WWOA Lake Michigan District by Mead & Hunt, Inc.

City of Riverside Building & Safety Division Phone: (951)

misconceptions about arc-flash hazard assessments

SINGLE FAMILY DWELLING ELECTRICAL SERVICES RATED 225 TO 600 AMPS

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

GENERAL ELECTRICAL REQUIREMENTS

Construction Electrical Terminology. Electricians

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

ARC FLASH CALCULATIONS & LABELING REQUIREMENTS

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

Electrical Hazards. Power Tools. Extension Cords

Electrical Code Regulation

Element D Services Electrical

ELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED

ELECTRICAL REQUIREMENTS Specific Information for Electrical Work Installers

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Who sets the rules for electrical testing and safety?

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Evaluating Water-Damaged Electrical Equipment

Grounding & Bonding Why it is done And How to Install Properly

Commercial/Industrial Electricity

Evaluating Water-Damaged Electrical Equipment

Evaluating Water-Damaged Electrical Equipment

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

Arc Fault Circuit Interrupters Frequently Asked Questions

3053 Electrical Safety Training Program Course Outline

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

COUNTY OF LOS ANGELES BUILDING AND SAFETY DIVISION ELECTRICAL CODE FEE SCHEDULE (Title 27 of the County of Los Angeles Code, Ord No.

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

NFPA 70E Updates Affect Your Most Valuable Assets

MASTER ELECTRICIAN CODE EXAMINATION EXAMINATION REFERENCE MATERIAL AND CONTENT OUTLINE. Answers to sample questions: CONTENT OUTLINE

Department of Labor and Industry Electrical Licensing

RISK MITIGATION for ELECTRICAL WORK. Feb 2013 San Diego CA

AFCIs Come of Age. by Douglas Hansen

Building Permit Application

Analyzing Electrical Hazards in the Workplace

Residential Questions and Answers 2011

CONTINUING EDUCATION FOR OREGON ELECTRICIANS NEC Code Changes. AMERICAN ELECTRICAL INSTITUTE PO Box Spokane, WA

ADOPTION OF THE NATIONAL ELECTRICAL CODE, 2005

Crawford Inspection Services C.C.B. #

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Transcription:

A new twist on the National Electrical Code - a practical application workshop. If you sign up in this class, prepare to work! Day 1: Fundamentals of OSHA requirements for performing electrical work - NFPA 70E. Days 2: Practical applications of NFPA 70E - not just the typical Code lecture. Day 3-5: Practical side of NEC including important Code calculations, the best methods to find information quickly in the Code. Receive a new NFPA 70E Code Book and the NTT NEC Practical Applications Workbook. Whether new to the NEC or a seasoned electrician or engineer, this class is all about learning how to use the Code. Our new practical applications and calculations requirements brings the workshop courses together, and relates to Article 250 and other articles of the National Electrical Code (NEC) as well as NFPA 70E. The practical applications and calculations section uses the code to perform calculations and solve common residential and industrial application issues, detect size conductors using tables, determine overcurrent protection (fuses and breakers), set motor overloads, and size starters, controllers, disconnects and conduits. You will also cover how to maintain your electrical systems with the correct grounding and bonding techniques. CLASS FORMAT: Classroom Lecture STANDARD CLASS SIZE: NTT recommends a class of no more than 35 participants to obtain the best results. NTT TO PROVIDE: Textbooks Classroom consumables Completion certificates Course syllabus, outline, table of contents, or training objectives Shipping and instructor travel logistics CLIENT PROVIDES: Classroom of 500 square feet or greater Projection screen, white board and/or flip chart(s) WHO SHOULD ATTEND: Electricians Mechanics Environmental health & safety personnel Apprentice and experienced HVAC technicians Supervisors working on or who oversee employees working on 50V or greater equipment Linemen & Utility workers Owners & managers Warehouse employees Maintenance Technicians Energy management personnel Fire Alarm Technicians Plant & facility maintenance technicians Building engineers Building managers & superintendents Plant & facility managers Stationary engineers Safety directors

COURSE AGENDA INTRODUCTION TO ELECTRICAL SAFETY History and overview of Electrical Safety Brief History of OSHA Overview of the OSHA Regulations and where Electrical Safety Regulations are found OVERVIEW OF THE NFPA 70E STANDARD Relationship to OSHA Regulations and how to implement the NFPA 70E Standard Article 90 Introduction to NFPA 70E overview Key definitions in Article 100 Determine the breakdown of responsibilities in your facility THE HAZARDS OF ELECTRICITY Basic of Electricity Arc Flash Hazard PPE Categories Electrical Hazards o Shock o Arc Flash o Arc Blast GENERAL REQUIREMENTS FOR ELECTRICAL SAFETY-RELATED WORK PRACTICES (ARTICLE 110) The Electrical Safety Program Training Requirements Relationships with Contractors Use of Equipment o Test Instruments o Portable Electric Equipment o Extension Cords o GFCI s Underground Electrical Lines and Equipment ESTABLISHING AN ELECTRICALLY SAFE WORK CONDITION (ARTICLE 120) The six-step LOTO process WORK ON OR NEAR EXPOSED ENERGIZED PARTS (ARTICLE 130) Limitations for working when exposed to energized parts Hazard analysis Energized Electrical Work permit requirements Energized Electrical Work permit Approval process Description of Safe Work Practices to be employed Energized Electrical Work permit Exemptions SHOCK PROTECTION BOUNDARIES Shock Risk Assessment Establishing Shock Protection Boundaries o Using the AC and DC tables Approach Requirements for Qualified Persons Approach requirements for Unqualified Persons ARC FLASH BOUNDARY The Arc Flash Risk Assessment Establishing the Arc Flash Boundary PPE within the Arc Flash Boundary Equipment labeling requirements OTHER PRECAUTIONS Alertness / Situational Awareness Blind Reaching Illumination Conductive articles being worn

2014 NATIONAL ELECTRICAL CODE (NEC) & Conductive materials Confined or enclosed work space Doors or hinged panels Housekeeping duties Use of flammable materials Anticipating failure Routine opening and closing of circuits. Reclosing circuits after protective device operation PERSONAL AND OTHER PROTECTIVE EQUIPMENT General: Responsibilities Care PPE Specifics Other PPE INTERPRETING EQUIPMENT LABELS Arc-flash information Shock protection information Selecting PPE Boundary Selection USING THE TABLES Identifying equipment and tasks Applicability of the tables Determining the table parameters Determining equipment meets installation requirements Determining equipment has been properly maintained Selecting PPE WORKING WITHIN THE LIMITED APPROACH BOUNDARIES TO OVERHEAD LINES Applicability Specific requirements Which rules apply: Applicability of other rules and standards o 1910.269 o NESC SAFETY-RELATED MAINTENANCE REQUIREMENTS General maintenance requirements Substations, switchgear assemblies, switchboards, panelboards, motor control centers, and disconnect switches Premises wiring Controller equipment Fuses and circuit breakers Rotating equipment Hazardous (classified) locations Batteries and battery rooms Portable electric tools and equipment Personal safety and protective equipment SAFETY REQUIREMENTS FOR SPECIAL EQUIPMENT Electrolytic Cells Batteries and Battery Rooms Safety-Related Work Practices for Use of Lasers Power Electronic Equipment Research and Development Laboratories

The purpose of the 2014 NEC is the practical safeguarding of persons and property from hazards arising from the use of electricity. The requirements in the 2014 NEC address the fundamental principles of installation for safety. NEW OR REVISED ARTICLES FOR 2014 Article 393 Low Voltage Suspend Ceiling Power Distribution Systems Article 646 Modular Data Centers Article 728 Fire Resistant Cable Systems Article 750 Energy Management Systems Symbol requirements for controlled receptacles DC voltage requirements expanding Increasing the voltage threshold from 600 volts to 1,000 volts Electrical Safety labeling requirements changing and new sections added Increased requirements for GFCIs in laundry areas, facilities like car washes, and generator receptacles AFCI requirements expanding into laundry rooms and kitchens as the NEC move towards wholehouse protection New section on Ground Fault Protection of equipment Exception for XHHW-2 conductors for specified temperature corrections for ampacity values Mounting of luminaires Increasing receptacle requirements in health care facilities Deleting the term Emergency Systems in health care facilities Moving several definitions from individual articles to Article 100 ALTERNATE ENERGY, GREEN TECHNOL- OGIES, AND IT EQUIPMENT CHANGES Revised Article 625: Updates on safe battery charging for plug-in hybrid vehicles that reduce the risk of explosion Revisions to Article 645: IT Equipment New Article 694: First-time requirements for small wind electric systems Revised Article 705: Interconnecting generators, windmills, and solar and fuel cells with other power supplies New Article 840: The increased demand for broadband communication systems with requirements for wireless, routers, and wireless disconnects OTHER REQUIREMENTS FOCUSED ON WORKPLACE SAFETY Provisions on electrical installations over 600 volts 240.87: Means to reduce incident energy New Article 399: Incorporates requirements for overhead distribution systems for large electrical system users, such as school or business campus settings 408.4B: Labeling at subpanels to identify feeder supply source 450.14: Disconnecting means for transformers NEC COURSE AGENDA APPLYING THE NEC ARTICLE 90 NEC process and definitions Equipment examination Code change introduction Metric and standard units ELECTRICAL INSTALLATIONS ARTICLE 110 Approval Conductors Equipment Mechanical installations Mounting and cooling Electrical connections Arc flash protection Spaces about electrical equipment

NEC COURSE AGENDA, continued BRANCH CIRCUITS AND FEEDERS ARTICLE 210 Branch circuits Review of Code changes Branch circuit ratings Multiwire branch circuits Identification of ungrounded conductors Color code for branch-circuit grounded conductors Color code for branch-circuit equipment grounding conductors Receptacle and cord connectors Replacing receptacles Dwelling units Bathrooms Garages and accessory buildings Buildings Other than dwelling units Required branch circuits Branch-circuit ratings 210.19 Minimum size conductors Overcurrent protection Feeders Minimum rating and size Feeders with common neutral Identifying high-leg in Delta 4-wire systems Ground-fault protection of equipment SERVICES ARTICLE 230 Definitions Service limitations Number of services Conductors outside of buildings Service raceways and seals Clearance from openings Overhead service-drop conductors Underground service-lateral conductors Service-entrance conductors Service Equipment AIC rating Identification Disconnecting mmeans Ground-fault protection of equipment CONDUCTORS AND OVERCURRENT PROTECTION ARTICLE 240 Conductors Ampacity Insulation ratings Ambient temperature Overcurrent protection Protection of conductors Ampere ratings Location of overcurrent protection devices Underground conductor Grounded conductor Circuit location Overcurrent Devices Plug and cartridge fuses Circuit breakers CB markings GROUNDING & BONDING ARTICLE 250 Grounding terminology Grounding systems Grounding equipment and enclosures Grounding means Bonding Services Bonding over 250 volts Main and equipment bonding jumpers

NEC COURSE AGENDA, continued Grounding Electrode System Part III Equipment Grounding Conductors WIRING METHODS ARTICLE 300 Wiring Methods Conductors of same circuit Conductors of different systems Protection from physical damage Underground installations Protection against corrosion Mechanical continuity of raceways and cables Length of conductors at outlet box Boxes, conduit bodies, or fittings required Supporting conductors in a vertical raceway Preventing heating effects of inductive current in metallic parts Securing integrity of fire-resistant-rated walls Preventing spread of toxic fumes in an air-handling system WIRING MATERIALS RACEWAYS AND BOXES ARTICLE 300 Raceway systems Rigid metal and nonmetallic conduit Electrical metallic tubing Flexible metal conduit Liquid-tight flexible metal and nonmetallic conduit Cable Assemblies Metal-clad cable Armored cable Nonmetallic-sheathed cable Other wiring systems Cable Tray Systems Wireways Busways Auxiliary gutters Boxes, Conduit Bodies, and Fittings WIRING MATERIALS Switches Article 404 Switchboards and panelboards ARTICLE 408 Panelboards Number of overcurrent devices on one panelboard Grounding of panelboards EQUIPMENT FOR GENERAL USE ARTICLE 400 Flexible Cords and Flexible Cables Luminaries Article 410 Luminaries locations Flush and recessed fixtures Electric-discharge equipment 1000 volts or less Lighting track Receptacles, cord connectors and attachment plugs Tamper resistant receptacles Grounding and non-grounding receptacles Isolated-ground receptacles Hospital-grade receptacles GFCI-type receptacles Appliances Article 422 Installation requirements Disconnecting means Safety provisions Markings MOTORS, GENERATORS, A/C & REFRIGERATION, AND FIRE PUMPS Motors Article 430 Review of Code changes Ampacity and motor ratings Markings on motors and multimotor equipment and controllers Branch circuit single motor

NEC COURSE AGENDA, continued Motor control circuits and centers Disconnecting means MOTORS, GENERATORS, A/C & REFRIGERATION, AND FIRE PUMPS, CONTINUED A/C and Refrigeration Equipment Article 440 Single equipment Disconnecting means Branch-circuit fuses or circuit breakers Room A/Cs Part VII Fire Pumps Article 695 Power source to electric-motor driven fire pumps TRANSFORMERS ARTICLE 450 Transformer construction and types Transformer installation Transformer vaults SPECIAL LOCATIONS ARTICLE 500 AND 600 Electrified truck parking spaces ARTICLE 626 Hazardous locations Article 500 Group classifications Wiring methods Conduit seals Motors and generators Grounding Intrinsically safe systems Service and Repair Garages Article 511 Health care facilities Places of assembly