Aeon Labs Smart Switch Gen5 (Z Wave Smart Switch Gen5)

Similar documents
Quick start: Energy Switch EU

LED Bulb Manual. Aeotec by Aeon Labs LED Bulb.

Please refer to the chapters below for detailed information about all aspects of the products usage.

Quick start: Panic Watch EU

ZME_RC2 Z-Wave Remote Control

ZME_WALLC-S Z-Wave Secure Wall Controller

Battery Wall Controller. Manual

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

Adding to Z-Wave TM Network

Modbus TCP / DALI converter

Table 1 below is a complete list of MPTH commands with descriptions. Table 1 : MPTH Commands. Command Name Code Setting Value Description

Solar Powered Outdoor Siren Manual

Z-Wave Gas Reader. Product Manual NQ-9121-EU. From your Z-wave network directly to the cloud! DESCRIPTION

NOQ_NQ-9121 Z-Wave Data Logger for Gas Meters Firmware Version : 2.55

Z-Wave.Me Wall Controller

KD-204. Telephone Remote Switch. Operating Instructions

ACR122 NFC Contactless Smart Card Reader

RPDO 1 TPDO 1 TPDO 5 TPDO 6 TPDO 7 TPDO 8

Inwall 4 Input / 4 Output Module

CHAPTER 1 COMMANDS FOR DEVICE MANAGEMENT...

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

Advanced User s Guide

NHD-0420D3Z-FL-GBW-V3

eztcp Technical Document Modbus/TCP of eztcp Caution: Specifications of this document may be changed without prior notice for improvement.

Consult protocol, Nissan Technical egroup, Issue 6

Nemo 96HD/HD+ MODBUS

ST815 Illumination Sensor with LCD

13-1. This chapter explains how to use different objects.

ZXT-120 (Z-Wave-to-AC IR Extender) Firmware Version: V1.0 and V1.1

Advanced User s Guide

Brunata Optuna W (171)

SRF08 Ultra sonic range finder Technical Specification

Lynx Touch L5100 Technical Training. Z-Wave Setup

Communications Protocol for Akai APC40 Controller

Configurable Events for APC Network Management Card

Z-Way Home Automation User Interface Documentation. (c) Z-Wave.Me Team, based on Version 2.0

CTNET Field Protocol Specification November 19, 1997 DRAFT

Bluetooth HID Profile

1 Application Description Objective Goals... 3

EM6556 e-domotica Mini Switch

GSM Temperature Alerter. User Manual. Manual version 1.0

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version ( )

Smart Wireless Devices. LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device.

PRODUCT MANUAL LUMENTO X4 LED. LED Controller ZN1DI-RGBX4. Program version: 1.0 Manual edition: a

Tebis application software

F453. TiF453. User guide 10/11-01 PC

Application Programming Interface

The Answer to the 14 Most Frequently Asked Modbus Questions

WIZnet S2E (Serial-to-Ethernet) Device s Configuration Tool Programming Guide

Hagenberg Linz Steyr Wels. API Application Programming Interface

EMR 3 CAN BUS specification

GW-7552 PRIFIBUS/MODBUS GATEWAY

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

USB Card Reader Configuration Utility. User Manual. Draft!

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

Olson Electronics Remote Power Monitoring Meter

CCTR-805-V2 3G Car GPS Tracker

Sign-up Tool User Manual

User Manual. AS-Interface Programmer

BEC 6200WZL. 4G/LTE Cellular Broadband Router. Quick Start Guide

IDDERO HOME SERVER. Quick start guide

DNP Points List and Implementation

Interface Protocol v1.2

Software User Guide UG-461

How To Use A Power Supply On A Powerline 2.2 (Ai)

MBP_MSTR: Modbus Plus Master 12

CMC-DN01 DeviceNet Slave Communication Card Operation Manual

Technical Support Bulletin Nr.18 Modbus Tips

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 2.1)

How To Run A Factory I/O On A Microsoft Gpu 2.5 (Sdk) On A Computer Or Microsoft Powerbook 2.3 (Powerpoint) On An Android Computer Or Macbook 2 (Powerstation) On

Chapter I Model801, Model802 Functions and Features

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Dr Robot C# Advance Sputnik Demo Program

1. Learn about the 555 timer integrated circuit and applications 2. Apply the 555 timer to build an infrared (IR) transmitter and receiver

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

73M1866B/73M1966B FXOCTL Application User Guide November 2, 2009 Rev. 4.1 UG_1x66B_009

SOFTWARE GUIDE PM1405 DATA PROCESSING SOFTWARE

Inwall Room Temperature Unit

HOST Embedded System. SLAVE EasyMDB interface. Reference Manual EasyMDB RS232-TTL. 1 Introduction

SMS Alarm. User Manual

NC-12 Modbus Application

Powerline 1200 User Manual

Original instructions. PLUTO Gateway. User Manual. PROFIBUS GATE-P1/P2 DeviceNet GATE-D1/D2 CANopen GATE-C1/C2 Ethernet GATE-E1/E2

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Creating a Project with PSoC Designer

Light scene push button 8gang comfort flush-mounted xx

Time functions. Functions of the relay. instabus EIB Application program description. September A1 Binary 510D01

Automatic start of a generator

GeoVision Setup. Once all the settings for Windows are completed and you have all the hard drives setup you can install GeoVision.

RS-485 Protocol Manual

Operating Manual Remote Cost Control Monitor

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

24 Port Gigabit Ethernet Web Smart Switch. Users Manual

Supporting ZDOs with the XBee API

IP Power Stone 4000 User Manual

1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0

Transcription:

Aeon Labs Smart Switch Gen5 (Z Wave Smart Switch Gen5)

Change history Revision Date Change Description 1 3/13/2014 Initial draft. 2 5/15/2014 Updated Z wave module to 500 series 3 7/16/2014 Added configuration parameter 20 and 81.

Aeon Labs Smart Switch Gen5 Engineering Specifications and Advanced Functions for Developers (V3.25) Aeon Labs Smart Switch is a Z Wave power binary switch device based on Z Wave enhanced 232 slave library V6.51.00. The Smart Switch has 3 Configuration report groups. Configuration report group is differ from ASSOCIATION GROUP. Report group is a group that you can set automatic reports to be sent at a certain interval time. All the reports will be sent at the same time in one Configuration report group. The interval of transmission for each report group can be specified (configurable parameters 111 113). If the Smart Switch does not set association nodes, it will not send automatic reports. As soon as Smart Switch is removed from a z wave network it will be restored into default factory setting. 1. Library and Command Classes 1.1 SDK: 6.51.00 1.2 Library Basic Device Class: BASIC_TYPE_ROUTING_SLAVE Generic Device class: GENERIC_TYPE_SWITCH_BINARY Specific Device Class: SPECIFIC_TYPE_POWER_SWITCH_BINARY 1.3 Commands Class Included Non Secure Network Included Secure Network Node Info Frame Security Command Supported Report Frame COMMAND_CLASS_ZWAVEPLUS_INFO V2 COMMAND_CLASS_SWITCH_BINARY V1 COMMAND_CLASS_METER V3 COMMAND_CLASS_SWITCH_ALL V1 COMMAND_CLASS_SCENE_ACTUATOR_CONF V1 COMMAND_CLASS_SCENE_ACTIVATION V1 COMMAND_CLASS_CONFIGURATION V1 COMMAND_CLASS_CRC_16_ENCAP V1 COMMAND_CLASS_ASSOCIATION_GRP_INFO V1 COMMAND_CLASS_ASSOCIATION V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC V2 COMMAND_CLASS_VERSION V2 COMMAND_CLASS_FIRMWARE_UPDATE_MD V2 COMMAND_CLASS_POWERLEVEL V1 COMMAND_CLASS_SECURITY V1 COMMAND_CLASS_MARK V1 COMMAND_CLASS_DEVICE_RESET_LOCALLY V1 COMMAND_CLASS_HAIL V1 COMMAND_CLASS_ZWAVEPLUS_INFO V2 COMMAND_CLASS_VERSION V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC V2 COMMAND_CLASS_SECURITY V1 COMMAND_CLASS_CRC_16_ENCAP V1 COMMAND_CLASS_MARK V1 COMMAND_CLASS_DEVICE_RESET_LOCALLY V1 COMMAND_CLASS_HAIL V1 - COMMAND_CLASS_SWITCH_BINARY V1 COMMAND_CLASS_METER V3 COMMAND_CLASS_SWITCH_ALL V1 COMMAND_CLASS_SCENE_ACTUATOR_CONF V1 COMMAND_CLASS_SCENE_ACTIVATION V1 COMMAND_CLASS_CONFIGURATION V1 COMMAND_CLASS_CRC_16_ENCAP V1 COMMAND_CLASS_ASSOCIATION_GRP_INFO V1 COMMAND_CLASS_ASSOCIATION V2

COMMAND_CLASS_MANUFACTURER_SPECIFIC V2 COMMAND_CLASS_VERSION V2 COMMAND_CLASS_FIRMWARE_UPDATE_MD V2 COMMAND_CLASS_POWERLEVEL V1 2. Technical Specifications Operating distance: Up to 100 ft / 30 meters indoors and 300 ft / 100 meters outdoors. Input: 120V~, 60Hz. (USA Version) 230V~, 50Hz. (EU, AU, BR, CN, IN Version) Output: 120V~, 60Hz, Max 15A Resistor load. (USA Version) 230V~, 60Hz, Max 16A Resistor load. (EU Version) 230V~, 60Hz, Max 15A Resistor load. (IN Version) 230V~, 60Hz, Max 10A/15A Resistor load. (CN Version) 230V~, 60Hz, Max 10A/15A Resistor load. (AU Version) 230V~, 50Hz, Max 16A Resistor load. (BR version) Operating temperature: 0 to 40. Relative humidity: 8 80% 3. Familiarize yourself with your Smart Switch 3.1 Interface 4. All functions of each trigger 4.1 Function of Z Wave Button Trigger Description Click one time Add Smart Switch into an existing z wave network: 1. Insert the Smart Switch to power socket, The Smart Switch LED will blink slowly. 2. Let the primary controller into inclusion mode (If you don t know how to do this, refer to its manual). 3. Press the Z Wave button. 4. If the inclusion success, Smart Switch LED will keep turning on. Otherwise, the LED will

still blink slowly, in which you need to repeat the process from step 2. Press and hold 20 seconds Remove Smart Switch from an existing z wave network: 1. Insert the Smart Switch to power socket, The Smart Switch LED will follow the status (on/off) of its load. 2. Let the primary controller of existing Z Wave network into remove mode (If you don t know how to do this, refer to its manual). 3. Press the Z Wave button. 4. If the remove success, Smart Switch LED will blink slowly. If Smart Switch LED still follows that of load status, please repeat the process from step 2. Reset Smart Switch to factory Default: 1. Make sure the Smart Switch has been connected to the power supply. 2. Press and hold the Z wave button for 20 seconds. 3. If holding time more than one second, the LED will blink faster and faster. If holding time more than 20seconds, the LED will be on for 2 seconds, it indicates reset success, otherwise please repeat step 2. Note: Reset Smart Switch to factory default settings will: sets the Smart Switch to not in Z Wave network state; delete the Association setting, power measure value, Scene Configuration Settings and restore the Configuration setting to the default. 5. Special rule of each command 5.1 Z-Wave Plus Info Report Command Class Parameter Value Z Wave Plus Version 1 Role Type Node Type Installer Icon Type User Icon Type 5 (ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON) 0 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE) 0x0700 (ICON_TYPE_GENERIC_ON_OFF_POWER_SWITCH) 0x0700 (ICON_TYPE_GENERIC_ON_OFF_POWER_SWITCH) 5.2 Association Command Class The Smart Switch supports 2 Association groups. a. The Node IDs in Group 1 will receive Hail Command /Basic report (configurable) which is sent via single cast (if there are more than 1 Node ID) when the state of Micro Switch s load changed. b. The Node IDs in Group 1 will receive Meter REPORT (for watt/ KWH) (configurable) which is sent via single cast ( if there are more than 1 Node ID) when the auto report be setting. c. When the Smart Switch receives the following commands, it will forward the commands to all node IDs which are in Group 2. The command will be sent via single cast (if there are more than 1 Node IDs). Commands: Basic Set, Switch Binary Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set, Scene Activation Set.

5.3 Association Group Info Command Class 5.3.1 Association Group Info Report Command Class Profile: General: NA (Profile MSB=0,Profile LSB=0) 5.3.2 Association Group Name Report Command Class Group 1 :Lifeline Group 2:RetransmitSwitchCC 5.4 Scene Actuator Conf Command Class The Smart Switch supports max 255 Scene ID. The Scene Actuator Conf Set command is effective, when only Level>=0 and Level<0x64 or Level=0xff, otherwise, it will be ignored. The Scene Actuator Configuration Get Command is used to request the settings for a given scene, if scene ID is not setting, it will be ignored. If the scene ID setting Dimming Duration = 0xff then Dimming Duration=0 else Dimming Duration= settings value. If Scene ID =0, then the Smart Switch will report currently the activated scene settings. If the currently activated scene settings do not exist, the Micro Switch will reports Level = currently load status and Dimming Duration=0 5.5 Scene Activation Set Command Class The Scene Activation Set Command is effective, when only Level>=0 and Level<0x64 or Level=0xff, otherwise, it will be ignored. If the requested Scene ID is not configured, it will be ignored too. 5.6 Configuration Set Command Class 7 6 5 4 3 2 1 0 Command Class = COMMAND_CLASS_CONFIGURATION Command = CONFIGURATION_SET Parameter Number Default Reserved Size Configuration Value 1(MSB) Configuration Value 2 Configuration Value n(lsb) Parameter Number Definitions (8 bit): Parameter Number Hex / Decimal Description Default Value Size

0x02 (2) Make Smart Switch blink. Configuration Value 1:1 255 0x0f0a 2 Configuration Value 1 is to Specify the time that Smart Switch need blink, The unit is Second; Configuration Value 2:1 255 0x03 (3) 0x14 (20) 0x50 (80) 0x51 (81) 0x5A (90) 0x5B (91) 0x5C (92) 0x64 (100) Configuration Value 2 is to Specify the Cycle of on/off, the unit of it is 0.1 second. For example: if we set Configuration Value 1 to '15',Configuration Value 2 to '10',then Smart Switch will open 0.5 second, close 0.5 second, and repeat for 14 times. Current Overload Protection. Load will be closed when the Current overrun (US: 15.5A, other country: 16.2A) and the time more than 2 minutes (0=disabled, 1=enabled). Configure the output load status after re power on (0=last status, 1=always on, 2=always off) Enable to send notifications to associated devices (Group 1) when the state of Micro Switch s load changed (0=nothing, 1=hail CC, 2=basic CC report). Configure the state of red LED: 0: The LED will follow the status (on/off) of its load. 1: When the state of Switch s load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action. Enables/disables parameter 91 and 92 below (1=enabled, 0=disabled). The value here represents minimum change in wattage (in terms of wattage) for a REPORT to be sent (Valid values 0 60000). The value here represents minimum change in wattage percent (in terms of percentage) for a REPORT to be sent (Valid values 0 100). Set 101 103 to default. 1 1 25(W) 2 5(%) 1 N/A 1

0x65 (101) 0x66 (102) 0x67 (103) 0x6E (110) 0x6F (111) 0x70 (112) 0x71 (113) 0xC8 (200) Which reports need to send in Report group 1 (See flags in table below). Which reports need to send in Report group 2 (See flags in table below). Which reports need to send in Report group 3 (See flags in table below). Set 111 113 to default. The time interval of sending Report group 1 (Valid values 0x01 0xFFFFFFFF). The time interval of sending Report group 2 (Valid values 0x01 0xFFFFFFFF). The time interval of sending Report group 3 (Valid values 0x01 0xFFFFFFFF). Partner ID (0= Aeon Labs Standard Product, 1= AT&T). 0x00 00 00 04 4 0x00 00 00 08 4 0 4 N/A 1 0x00 00 00 03 4 0x00 00 02 58 4 0x00 00 02 58 4 0xFC (252) Enable/disable Configuration Locked (0 =disable, 1 = enable). 0xFE (254) 0xFF (255) Device Tag. Reset configuration set up to default setting. 0 2 N/A 1 Configuration Values for parameter 101 103: 7 6 5 4 3 2 1 0 configuration Value 1(MSB) configuration Value 2 configuration Value 3 Reserved Reserved Reserved

configuration Value 4(LSB) Reserve d Reserve d Reserve d Reserve d Auto send Meter REPORT (for kwh) at the group time interval Auto send Meter REPORT (for watt) at the group time interval Auto send Meter REPORT (for current) at the group time interval Auto send Meter REPOR T (for voltage at the group time interval Example: a. Automatically report Meter CC (Watts) to node "1" every 12 minutes 1. Set report group 1 send Meter CC (Watts) automatically ZW_SendData(0x70, 0x04, 0x65, 0x04, 0x00,0x00,0x00,0x04); 2. Set the interval of sending report group 1 ZW_SendData(0x70, 0x04, 0x6F, 0x04, 0x00,0x00,0x02,0xd0); 3. Associate to node "1" ZW_SendData(0x85, 0x01, 0x01, 0x01); b. Set default values ZW_SendData(0x70, 0x04, 0x255,0x01,0x00);