HRV / ERV. HEALTHY CLIMATE Heat / Energy Recovery Ventilator I N D O O R A I R Q U A L I T Y E N G I N E E R I N G D A T A MODEL NUMBER IDENTIFICATION

Similar documents
Operation and Installation Manual. Max Series

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

CE6500 Energy Recovery Ventilator

Commercial Gas Furnace Upflow

Dehumidification Frequently Asked Questions

Low Cost. Lower Energy Costs. Higher Efficiency.

RPV - RP - RA air handling units

Innovent LASER Packaged Fresh Air Conditioning Units

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech

Cooling Capacity CFM in. w.c. (125 Pa)

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

FOXAIR 60/50 ALL MODELS

A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses

HRV and ERV Best Practices. December 18, 2012 Portland Metro Home Builders Association

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

Installation, operation and maintenance manual TX 35A

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

F9MXE. Product Specifications

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

GCS16 GCS20 WARNING CAUTION

Ventilation Solutions Kitchens. fantech

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

CB29M Bulletin # February 1996

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

ARMSTRONG AIR HEAT PUMPS

"EC" Series Electric Humidifier

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Single Package Vertical Air Conditioners. Vert-I-Pak

Basics of HVAC Cleaning

MovinCool Office Pro Series. The Portable Spot Cooling Solution

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

york air-conditioning products Residential & VRF News 2015

Portable Air Conditioner

warm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%.

HEALTHY CLIMATE HEPA BYPASS AIR FILTRATION SYSTEM READ AND SAVE THESE INSTRUCTIONS! AIR CLEANERS/ FILTERS

FTXS. Wall Mount Heat Pump or Cooling Only

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

ECO-AIR AIR CONDITIONING

CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB

G9MXE. Product Specifications

Installation and maintenance instructions. Danfoss Vent

catalog Single Package Vertical Air Conditioners and Heat Pumps

Residential Ventilation

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

FTQ. Daikin Inverter Ducted Heat Pump

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

SECTION HEAT PUMPS

Single Zone LCD Thermostat Operating Instructions

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

Dehumidifier Users manual. For Models: DH45S DH65S

Element D Services Heating, Ventilating, and Air Conditioning

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

USER S MANUAL HSC-24A

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

Glossary of Heating, Ventilation and Air Conditioning Terms

PACKAGED TERMINAL AIR CONDITIONERS

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Kitchen Ventilation Systems: Part 2 Providing Adequate Makeup Air

Bring the fresh in. Dedicated Outside Air Systems

Glossary of HVAC Terms

GCS

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

PRODUCT CATALOG. Indoor Units

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

Installation Manual CLIFC Fan & Coil Variable Speed

CEILING CASSETTE FAN COIL UNIT

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Mechanical Rooftop Custom Capabilities

Owner s Manual Model 5000 Safety, Operating and Maintenance Instructions

NAVIEN AMERICA INC FITCH AVENUE

PORTABLE AIR CONDITIONER

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Lesson 36 Selection Of Air Conditioning Systems

Cooling/Heat Pump Convertible Air Handlers

Evaluate, Clean, and Tune Guidance

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

Quest 105, Dry155, and 205 Dual

Important Safeguards

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION BLOWER COIL UNITS

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Transcription:

I N D O O R A I R Q U A L I T Y HRV / ERV HEALTHY CLIMATE Heat / Energy Recovery Ventilator E N G I N E E R I N G D A T A Bulletin No. 210323 June 2006 Supersedes August 2004 MODEL NUMBER IDENTIFICATION HRV 2 0 0 3 Minor Revision Number FEATURES Unit Type HRV = Heat Recovery Ventilator ERV = Energy Recovery Ventilator TABLE OF CONTENTS Application Map............................ Page 4 Dimensions................................ Page 6 Features................................ Pages 1 3 Model Number Identification.................. Page 1 Optional Accessories........................ Page 5 Specifications.............................. Page 5 System Applications ERV................ Pages 8 9 System Applications HRV................ Pages 7 8 Warranty HRV aluminum core Limited lifetime warranty in residential applications, one year in non residential. ERV enthalpic core Five year limited warranty in residential applications, one year in non residential. Blower motor five year limited warranty in residential applications, one year in non residential. All other covered components seven year limited warranty in residential applications, one year in non residential. Refer to Limited Warranty Certificate included with the equipment for more details. Air Capacity in CFM 150 = 150 cfm 200 = 200 cfm Approvals All units are CSA and Home Ventilating Institute R2000 approved and E.T.L. listed. All units conform to CAN/ULC-S110-M1986 for non-combustible material and CAN/ULC-S102-M88 for flame spread rating and smoke developed classification. Units are completely wired and include filters. Applications HRV Heat Recovery Ventilators (HRV) provide fresh, clean outdoor air with an energy saving temperature recovery of up to 78%. HRV s are recommended in regions where normal humidity levels occur. Intake and exhaust air passes through a patented thermally conductive aluminum core where heat is transferred from exhaust air to incoming air.

FEATURES ERV Energy Recovery Ventilators (ERV) provide fresh clean outdoor air while reducing humidity levels at the same time. ERV s are recommended in regions where high outdoor humidity levels occur. Not recommended where outdoor temperatures fall below 25ºF continuously for more than five days. Intake and exhaust air passes through an enthalpic core where heat is transferred from exhaust air to incoming air and moisture is reduced. Both Models Centrifugal blowers bring in fresh outdoor air while at the same time exhausting an equal amount of stale indoor air. A duct system distributes the fresh air and collects the stale air for removal from the building. System airflow must be balanced for maximum efficiency. Refer to Installation Instructions for system air flow balancing details. Air Filter Air filters are furnished in both exhaust and intake air streams. Foam filters are easily removed for cleaning. Design and location of filters allows maximum filtration with minimum air resistance. Blower Dual centrifugal type with single motor. Rubber insulated mounts furnished on all models. Blower motor housing design allows easy access for servicing. Multi speed direct drive PSC motor (low, continuous low medium and high speeds) Low and continuous low medium speed change available by interchanging wires on auto transformer in electrical control box. High speed available with optional remote controls. See Optional Accessories. Cabinet Constructed of 20 gauge pre-painted steel. Interior is lined with foil faced polystyrene to eliminate noise, condensation and air loss. Cabinet is designed for structural strength and long life. Access panels are hinged, have quick release latches and can be completely removed for easy access to filter(s) and heat exchanger(s) for servicing. Safety interlock switch automatically shuts off power to unit when access panel is opened. Patented, self locking balancing damper allows system airflow equalization. Threaded inserts with screws are furnished on cabinet for hanging unit with furnished PVC reinforced polyester rubber straps. Condensate drain pans have drain connection (HRV model). CORE ASSEMBLY HRV Patented Aluminum Core Aluminum plates have excellent heat transfer characteristics, are nonflammable, corrosion resistant and durable. Plates are mounted in stainless steel frame and are easily removable for cleaning. Opposed dimples pressed into each plate ensure proper separation within each core. Modular design ensures ease of service. ERV Enthalpic Core Enthalpic core has excellent latent and sensible heat transfer characteristics, are nonflammable, corrosion resistant and durable. Plates are mounted in a frame and are easily removable for cleaning. Opposed dimples pressed into each plate ensure proper separation within each core. Modular design ensures ease of service. ELECTRICAL Control Box Contains control circuit board and auto transformer. Circuit board controls operation of unit. Various operation modes are available by changing jumpers on board. Terminal strip furnished for connection of remote controls (ERV remote control, HRV dehumidistat and timer). Plug-in Electrical Connection Convenient 3 prong 120VAC plug provided for easy electrical connection. CONTROLS Damper Defrost (HRV Models Only) During a defrost cycle the damper opens permitting inside air to defrost the core while closing off outdoor air at the same time. Automatic damper defrost occurs when outdoor temperature drops below 25 F. Blower operates on high speed during defrost cycle. Consists of 3 minute defrost cycle with 17 minute waiting period in between defrost cycles (waiting period adjustable 17, 25 or 30 minutes). HRV Remote Wall Mount Dehumidistat (Furnished) Low voltage control designed for central locations. On/Off switch, dehumidistat, service reminder LED Ventilation control turns HRV system on and off. Adjustable from 20 to 80% relative humidity. Dehumidistat increases ventilation when required. Blower operates on high speed during dehumidification. ERV Remote Control (Furnished) Low voltage control designed for central locations. On/Off switch, service reminder LED Ventilation control turns ERV system on and off. ERV / HRV Recovery Ventilators / Page 2

FEATURES Interlock Capability Built in function on circuit board. Allows ERV/HRV to operate whenever furnace or air handler is operating. Refer to Installation Instructions for interlocking HRV/ERV to Furnace or Air Handler. OPTIONS 20 Minute Fan Timer Remotely located timer allows 20 minute high speed operation. One-touch button. LED shows timer status. Maximum wire length 100 ft. Up to four timers can be used with one HRV/ERV unit. Wall Mount Dehumidistat (For HRV Units Only) Remote mounted control turns HRV system on and off. Scaled in relative humidity from 20% to 80%; 24VAC Allows high speed operation when required. White decorator color. Complete with 60 ft. length of 3 wire control cable. DUCTWORK OPTIONS Flexible Ducts Insulated or Non Insulated Non-insulated ducts are available for connection to optional circular grilles. Constructed of aluminum foil/polyester laminate and metalized polyester film around a steel wire helix. Fully insulated fiberglass ducts have an R" value of 5.8 and are available for connection to optional outside weatherhoods. Available for inside use in standard 3 to 10 in. diameters and 25 ft. lengths. Underwriter s Laboratories Canada (ULC) listed Class 1 Duct. Hinged Kitchen Exhaust Grille Louvered panel is hinged for easy access to washable aluminum filter. Size 6 x 10 in. in white. AIR BALANCING TOOLS OPTIONS Balancing Damper 6 in. Digital Manometer Measures positive, negative or differential pressures of air and gasses. Range: 1 in. w.c. to 150 psid. Large easy to read LCD display. Lightweight, extruded aluminum case. Standard 9 volt battery operation (furnished). Low battery indicator. Piezoresistive pressure sensor Standard dual size connectors (1/8 in. or 3/16 in.) Pitot Tube Air Flow Balancing Kit Includes pressure differential gauge, Pitot tube, hose and carrying case. Pitot Tube Only Round Diffusers White molded plastic grilles are available for room distribution. Grilles are adjustable for system balancing. Available in 4 in, 6 in. and 8 in. diameters. Weatherhood Kit Two furnished per order no., one for intake air and one for stale air. Fully adjustable for different wall thickness. Complete with mesh bird screen and (2) insulating duct collars. Hinged hood allows easy cleaning of screen. White finish. ERV / HRV Recovery Ventilators / Page 3

APPLICATION MAP Severe Conditions Moderate Conditions Pacific Conditions Arid Zone Dry Climate Extreme Areas of High Humidity Severe Conditions HRV Required Moderate Conditions HRV Recommended Pacific Conditions HRV Recommended ERV Optional Arid Zone Dry Climate HRV Recommended * Extreme Areas of High Humidity ERV Recommended NOTE ERV not recommended where temperatures fall below 25ºF continuously for more than 5 days. *ERV not recommended in regions where high outdoor humidity causes air conditioning operation for dehumidification more frequently than heating system operation. ERV / HRV Recovery Ventilators / Page 4

SPECIFICATIONS HRV ERV Performance Model No. HRV 150 HRV 200 ERV 150 ERV 200 Maximum sensible effectiveness: 13 F outdoor air, 72 F 40% RH indoor air 78% 69% N/A N/A Sensible effectiveness @ 32 F 76% 67% 76% 67% Sensible efficiency (thermal) @ 32 F 66% 60% N/A N/A Sensible efficiency (thermal) @ 13 F 60% 59% 66% 60% Latent efficiency (moisture) 95 F 0% 0% 27% 27% Total efficiency 95 F 20% 20% 50% 50% Blower Air Flow vs. Static 0.1 in. w.g. 189 cfm 203 cfm 189 cfm 203 cfm Pressure (at high speed) 0.2 in. w.g. 182 cfm 198 cfm 180 cfm 198 cfm 0.3 in. w.g. 175 cfm 190 cfm 173 cfm 190 cfm 0.4 in. w.g. 165 cfm 181 cfm 165 cfm 181 cfm 0.5 in. w.g. 150 cfm 170 cfm 153 cfm 170 cfm Number of Speeds Available 3 3 3 3 Defrost type Damper Damper none none Ducts Duct Connections (No.) & diameter inch (2) 6 outside (2) 6 inside (1) 6 defrost (2) 6 outside (2) 6 inside (1) 6 defrost (2) 6 outside (2) 6 inside (2) 6 outside (2) 6 inside Condensate drain connection (o.d.) in. (2) 1/2 (2) 1/2 N/A N/A Electrical 120 volts 60 hertz 1 phase Fan Watts high speed @ 0.3 in. w.g. 173 182 173 182 Fan Watts low medium speed @ 0.3 in. w.g. 93 93 93 93 Fan Watts low speed @ 0.3 in. w.g. 63 70 63 70 Shipping weight lbs. 78 78 78 78 Optional Accessories Must Be Ordered Extra Air Balancing Balancing Damper, 6 in. 91X09 91X09 91X09 91X09 Tools Digital Handheld Manometer 86N62 86N62 86N62 86N62 Pitot Tube with Air Balancing Kit 56N82 56N82 56N82 56N82 Pitot Tube Only 72X52 72X52 72X52 72X52 Controls 20 Minute Fan Timer 89N18 89N18 89N18 89N18 Wall Mount Dehumidistat 27N53 27N53 1 Flexible Ducts No. required & diameter in. (2) 6 (2) 6 (2) 6 (2) 6 Hinged Kitchen Exhaust Grille (filter included) 18N48 18N48 18N48 18N48 Round Diffusers 4 in. diameter 72N59 72N59 72N59 72N59 6 in. diameter 72N60 72N60 72N60 72N60 8 in. diameter 72N65 72N65 72N65 72N65 Weatherhood Kit (2 furnished per order no.) 95P07 95P07 95P07 95P07 NOTE Effectiveness is based on temperature difference between the 2 airstreams. Efficiency includes parasitic losses from fan operation. 1 Contact your territory Manager for additional information. ERV / HRV Recovery Ventilators / Page 5

DIMENSIONS INCHES (MM) HRV SERIES HEAT RECOVERY MODELS FRESH AIR FROM OUTSIDE 33 5/8 (854) 14-3/4 (375) DEFROST DAMPER BLOWER DEFROST PORT FILTER HEAT EXCHANGER CORE STALE AIR TO OUTSIDE 19 (483) MOUNTING POINTS STALE AIR FROM INSIDE FILTER FRESH AIR TO INSIDE DRAIN PANS CONDENSATE DRAINS BLOWER BALANCING DAMPER NOTE All duct connection sizes 6 in. (152 mm) FRONT VIEW END VIEW NOTE Front clearance of 25 inches (635 mm) is recommended for servicing unit. ERV SERIES ENERGY RECOVERY MODELS 33 5/8 (854) 14-3/4 (375) BLOWER BALANCING DAMPER STALE AIR FROM INSIDE FILTER ENTHALPIC CORE FRESH AIR TO INSIDE 19 (483) MOUNTING POINTS FRESH AIR FROM OUTSIDE FILTER STALE AIR TO OUTSIDE FRONT VIEW BLOWER NOTE All duct connection sizes 6 in. (152 mm) END VIEW NOTE Front clearance of 25 inches (635 mm) is recommended for servicing unit. ERV / HRV Recovery Ventilators / Page 6

HRV SYSTEM APPLICATIONS HRV PARTIALLY DEDICATED SYSTEM INSTALLATION (Direct connection of HRV supply air stream to the air handler cold air return) (Stale air drawn from key areas of home) Stale Air To Return Air 36 in. (914 mm) Recommended Defrost air from clean area without combustion appliances Cold Air Return Field Supplied Balancing Damper STALE AIR from various parts of home. i.e. bathroom, kitchen, laundry (if required) Air Handler High Efficiency Air Filter or Electronic Air Cleaner HRV SIMPLIFIED INSTALLATION (Return/Return Method) (Direct connection of both HRV supply and exhaust air streams to the air handler cold air return) Return Air Stale Air To 40 in. (1016 mm) Minimum 36 in. (914 mm) Recommended Defrost air from clean area without combustion appliances Cold Air Return Stale Air From Building Field Supplied Balancing Damper Fresh Air To House Air Handler High Efficiency Air Filter or Electronic Air Cleaner ERV / HRV Recovery Ventilators / Page 7

HRV SYSTEM APPLICATIONS HRV FULLY DEDICATED SYSTEM INSTALLATION (Fresh air supplied to main living areas of house. Stale air drawn from key areas of home) Stale Air To Defrost air from clean area without combustion appliances Field Supplied Balancing Damper STALE AIR from various parts of home. i.e. bathroom, kitchen, laundry (if required) Fresh air to house main living areas... bedrooms, living room, rec. room etc. ERV SYSTEM APPLICATIONS ERV PARTIALLY DEDICATED SYSTEM INSTALLATION (Direct connection of ERV supply air stream to the air handler cold air return) (Stale air drawn from key areas of home) Stale Air To Return Air STALE AIRfrom various parts of home. i.e. bathroom, kitchen, laundry (if required) Field Supplied Balancing Damper 36 in. (914 mm) Recommended Cold Air Return Air Handler High Efficiency Air Filter or Electronic Air Cleaner ERV / HRV Recovery Ventilators / Page 8

ERV SYSTEM APPLICATIONS ERV SIMPLIFIED INSTALLATION (Return/Return Method) (Direct connection of both ERV supply and exhaust air streams to the air handler cold air return) Return Air 40 in. (1016 mm) Minimum Stale Air To 36 in. (914 mm) Recommended Field Supplied Balancing Damper Stale Air From Building Cold Air Return Air Handler High Efficiency Air Filter or Electronic Air Cleaner ERV FULLY DEDICATED SYSTEM INSTALLATION (Fresh air supplied to main living areas of house. Stale air drawn from key areas of home) Stale Air To STALE AIRfrom various parts of home. i.e. bathroom, kitchen, laundry (if required) Field Supplied Balancing Damper Fresh air to house main living areas... bedrooms, living room, rec. room etc. ERV / HRV Recovery Ventilators / Page 9

Visit us at www.lennox.com For the latest technical information, www.lennoxdavenet.com Contact us at 1 800 4 LENNOX NOTE Due to an ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 2006 Lennox Industries Inc.