Emission- and temperature measuring equipment an overview

Similar documents
Advanced Solutions for Gas Monitoring

SO 3 -Monitoring in Flue Gas of a Power Plant Application & Results

Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2

Temperature. LumaSense Technologies, Inc. supplies a unique selection of very precise calibration

Online Infrared Flue Gas Analyzer Gasboard 3000

Stack Sampling Stack sampling or source sampling

Emission Monitoring and Reporting (EMR) Guidelines for Continuous Emissions Measurements in Holcim Cement Plants

Analysis of Sampling Protocols for the EPA Animal Feeding Operations Consent Agreement

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

QGA Quantitative Gas Analyser

The photoionization detector (PID) utilizes ultraviolet

Page 1 of 10. MIDAC Corporation 130 McCormick Avenue, #111 Costa Mesa, CA (714)

Laser Diode Gas Sensors

POLLUTED EMISSION TREATMENTS FROM INCINERATOR GASES

Bridging the analytical gap

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer

Flue Gas Desulfurization CEMS Design Lessons Learned and Monitoring Technologies to Meet the New Mercury and Air Toxics (MATS) Rule

Infrared Spectroscopy 紅 外 線 光 譜 儀

Waste Incineration Plants

Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry

Infrared Viewers. Manual

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

THE DETECTION OF GREENHOUSE GASES

bulk 5. Surface Analysis Why surface Analysis? Introduction Methods: XPS, AES, RBS

Trace Gas Exchange Measurements with Standard Infrared Analyzers

2. Molecular stucture/basic

Light as a Wave. The Nature of Light. EM Radiation Spectrum. EM Radiation Spectrum. Electromagnetic Radiation

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

DUST EMISSION MONITORING SYSTEM

Local Heating Attacks on Flash Memory Devices. Dr Sergei Skorobogatov

Scientific and analytical consultancy services for industry

Absorption by atmospheric gases in the IR, visible and UV spectral regions.

Hygro-Thermometer + InfraRed Thermometer Model RH101

Solar Energy. Outline. Solar radiation. What is light?-- Electromagnetic Radiation. Light - Electromagnetic wave spectrum. Electromagnetic Radiation

Monitoring Air Emissions on Ships. Restricted Siemens AG 2014 All rights reserved.

h e l p s y o u C O N T R O L

How To Make A Plasma Control System

Department of Engineering Enzo Ferrari University of Modena and Reggio Emilia

Experiment #5: Qualitative Absorption Spectroscopy

Performance Assessment of EAGLE 5000 in Tobacco Smoke Environment. REPORT

Corrosion experiments in amine solutions

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

BEST PRACTICES IN LEAK DETECTION AND REPAIR (LDAR) PROGRAMS. November 06, 2014 By: François Thibodeau, Eng.

13.3 Factors Affecting Solubility Solute-Solvent Interactions Pressure Effects Temperature Effects

PI Chemistry - PI 24 HEAVY WATER LEAKAGE - DETECTION. 1. Name and briefly describe the operation of five of:

POLYDIMETHYLSILOXANE

Plasma Fusion Center Massachusetts Institute of Technology Cambridge, MA September 1995

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Colorimetric Determination of Iron in Vitamin Tablets

Introduction to Fourier Transform Infrared Spectrometry

Chem 1A Exam 2 Review Problems

World s Best Oil in Water Analyzers

Lasers Design and Laser Systems

When Safety Comes First. Emergency Safety Shower and Eye Wash Catalogue

Dual Laser InfraRed (IR) Thermometer

Satellite Remote Sensing of Volcanic Ash

ABSTRACT INTRODUCTION

Highly efficient flue gas analyzer

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

DIODE LASER BASED PHOTOACOUSTIC SYSTEM FOR ATMOSPHERIC WATER VAPOR MEASUREMENTS

RoHS Test Methods. Presented by: Bruce Peterson

Time out states and transitions

The testo 340 What makes it The Ultimate Combustion Tuner?

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

Scanning Near-Field Optical Microscopy for Measuring Materials Properties at the Nanoscale

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Intermolecular Forces

Technical Cleaning Ó

Adapter Catalog MOBILE METAL ANALYZER. SPECTRO isort and SPECTROTEST

Analytical Testing Services Commercial Price List ManTech International Corporation January 2016

2 Absorbing Solar Energy

OPERATION MANUAL INFRARED THERMOMETER

SENSORS FOR AIR QUALITY MONITORING MARCEL ZEVENBERGEN SR. RESEARCHER GAS AND ION SENSORS

OPTICAL DETECTION OF KCl VAPOR AND ATOMIC K RELEASES FROM BIOMASS FUELS COMBUSTED IN SINGLE PARTICLE REACTOR

3 - Atomic Absorption Spectroscopy

Eni experience and research with IR video-camera imaging

Chem 112 Intermolecular Forces Chang From the book (10, 12, 14, 16, 18, 20,84,92,94,102,104, 108, 112, 114, 118 and 134)

An update on the development of an accelerated aging method for roofing materials

Quantum cascade lasers for TDLS

Kompressoren. Adsorption Dryer AD

Advanced gas analysis kept simple

Method 202 Dry Impinger Method for Determining Condensable Particulate Emissions from Stationary Sources. By: Paul Ottenstein

MILESTONE CLEAN CHEMISTRY LINE DUOPUR TRACECLEAN ULTRA-TRACE INSERTS. A Breakthrough in Reduction and Control of the Analytical Blank MILESTONE

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Improving Steam Methane Reformer Performance with the ZoloSCAN-SMR

NMR and other Instrumental Techniques in Chemistry and the proposed National Curriculum.

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

What is Solar Control?

IV. Molecular Clouds. 1. Molecular Cloud Spectra

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Application Note AN1

Gas and flame detection Stack gas and dust analysis

Paper No APPLICATION OF EQCM TO THE STUDY OF CO2 CORROSION

Chemistry B11 Chapter 6 Solutions and Colloids

LI-7000 CO /H O Analyzer. High Speed, High Precision Differential Analyzer

Transcription:

Emission- and temperature measuring equipment an overview Heavy metals,pah, dioxins Infrared Camera Emission Analyser Particles FTIR Mass Spectrometer Open Path FTIR

FLIR SC1000 Infrared Cameras -20 to 2000 C, 2,0% -640x480 resolution -Spectral range: 7,5-13um FLIR SC640 525.6 C 520 500 480 460 440 420 400 380 360 340 321.1 C http://www.flir.com/thermography/eurasia/en/content/?id=11352

Multi-wavelength pyrometer FAR FMP2 Designed to measure molten metal, temperature range: 800-2500 C, ±0,25-0,75% Wavelength range: 500-1000nm (visible light between 380-750nm) Computer analysis and analog output 3 lenses - 0,5m, 1,5m and 6m measuring distance http://www.pyrometry.com/products.php?product=fmp2

Metlab 1925 Suction pyrometer -Accurate high temperature measurement in off gas, up to 1300 C -Radiation protected type K thermocouple inside the nozzle www.metlab.se/prod1.htm

Temperature Calibration Equipment 0-1300 C

Testo 350 Emission Analyzer 0-1300 C, continuous sample suction www.testo350.com/350.html

Portable Mass spectrometer 20 ml min -1 sampling rate Very fast response time Highly portable Large calibration range Heated capillary inlet Membrane adapter for application to liquids www.essco.com/prodportable.htm

Portable Mass Spectrometer Application areas: Leak detection: almost all species leave mass trace Examples of detection limits: CF4/C2F6: < 25 ppb H2SO4: < 5 ppm COS: < 5 ppm HF: < 5 ppm CO: < 5 ppm CO2: < 5 ppm HCl: < 5 ppm NH3: < 50 ppm SO2: < 5 ppm Cl2: < 1 ppm Toluene: < 1 ppb Krypton: < 2 ppb NOX: < 1 ppm H2: < 1 ppm CH4: < 50 ppb Benzene: < 1 ppb

Portable Protea 204M/C FTIR 0-1300 C, continuous sample suction

Open Path FTIR

Open Path FTIR Through-gas monitoring Atmospheric monitoring Portable (Tripod mountable, 35 kg) Fast response time Stiring cooled Application: general application see Tables of ProtIR 204M Special applications: Measuring of adsorbing gases like SO 3, H 2 S Corrosive gases like HF, H 2 SO 4, HCl Open path ftir

Tunable Diode Laser Absorption Spectroscopy: HF and H 2 O Neo Monitors Lasergas II SP Limit Of Detection (Path length 1 m): HF: 15 ppb H 2 O: 100 ppb Current Calibration (10 cm): 1 ppm - 3 % HF 0.01 10 % H 2 O Measuring cell: 10 cm Teflon coated Stainless Steel Sapphire glass P and T probes for compensation 12

ELPI 10lpm particle measuring High temperature particle measurements, up to 1300 C 7nm-10µm measuring range in 12 steps, 2-3 sec response time Gravimetric and chemical analysis possible after measurement High dust concentrations allowed due to extra diluters and cyclone Electrostatic measuring principle http://dekati.com/cms/elpi

Concentration of heavy metals, PAH and dioxins:

Prices and specifications Measuring equipment Prices Additional info FTIR, gas measurements up to 1300ºC Open path FTIR Portable mass spectrometer, gases up to 1300ºC PAH, dioxin and heavy metals Temperature range up to 1300 C ELPI particle size measurements Temoerature range up to 1300ºC METLAB suction pyrometer up to 1300ºC FAR spectro pyrometer, 800-2500ºC IR camera (640x480, 7.5-13µm) -40-2000ºC IR camera (256x256, 3.4-5µm) -10-2000ºC 8000,- first day, 1600,- following days 11000,- first day, 2200,- following days 4500,- first day, 900,- following days 5000,- first day, 1000,- following days 8000,- first day, 1600,- following days 600,- first day, 120,- following days 3000,- first day, 600,- following days 4000,- first day, 800,- following days 1000,- a day Rented out with trained operator/ engineer from SINTEF in addition Rented out with trained operator/ engineer from SINTEF in addition Rented out with trained operator/ engineer from SINTEF in addition Rented out with trained operator/ engineer from SINTEF in addition Rented out with trained operator/ engineer from SINTEF in addition Rented out with trained operator/ engineer from SINTEF in addition Rented out with trained operator/ engineer from SINTEF in addition. 2 weeks renting period Rented out with trained operator/ engineer from SINTEF in addition Temperature calibration equipment 0-1300ºC 2000,- a day Calibration at SINTEF with trained operator/ engineer from SINTEF in addition Lasergas - HF and H 2 O 2800,- first day 550,- following days

For questions or reservation, please contact: Svend Grådahl svend.gradahl@sintef.no, tel 98283893 SINTEF Materials & chemistry Alfred Getz vei 2 7465 Trondheim