OKU solar heating for swimming Pool. Instruction for installation an operating

Similar documents
OKU SOLAR HEATING FOR SWIMMING POOLS

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

Cooling system components, removing and installing

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

RESIDENTIAL INSTALLATION MANUAL HELIOCOL SOLAR POOL HEATER

SunMaxx Solar Filling Station Operating Instructions

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

MFH-5057 Ford Small-Block V-8 Fresh Water Cooling Kit Instructions

Battery Backup Sump Pump System

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Operators manual Basic water heater

Zenith Solar thermal 4.5m pump station Installation manual

SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List

HERZ-Thermal Actuators

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Solar Collector Series. Product List

Installation instruction of the flat solar collectors models ES1V2.0, ES1V2.65, ES2V/2.0 AL, EM2V/2.0, ES2V/2.65, ES2H/2.65 on the inclined tile roof.

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Lawn Sprinkler Systems Reserve Irrigation Inc. O & M. Version Roseland Drive Macedonia, Ohio

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Installation, operation and maintenance manual TX 35A

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

SOLAR CONSTRUCTION MANUAL

Installation and maintenance instructions. Danfoss Vent

Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions

VOYAGER 570G. 744A Sprayer Control

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Turbocharger system components, servicing

ECOCIAT. Domestic hot water heat recovery unit

SWIMMING POOL HEAT PUMP

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

CENTRAL AIR CONDITIONER SPLIT SYSTEM

Float and Thermostatic Traps Series H, C and X

Oil and Coolant Circulating Heating System. Model - OCSM

H41 Electrical Stage Aft Air Conditioner Unit Installation

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

How To Launch A Rocket From A Formica

UNIVERSAL MOUNTING SET (UMS) FOR ARTOLINK FSO EQUIPMENT

CHEMICAL CLEANING UNIT Product number:

SWIMMING POOL HEAT PUMP Owners Manual

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL

Volkswagen Golf > VW Rabbit GTI 2006->

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Portable Air Conditioner

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

with installation dynafact boost GAUGE this manual is for use with systems

swimming pool accessories

Volvo Penta Quality Line Marine Water Heaters. Owners Manual

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

METHOD STATEMENT FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

SOLAR WATER HEATER USER AND INSTALLATION MANUAL

REMOVAL AND INSTALLATION

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Constructing Cistern Installations

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

ALL IN ONE. Heat Pump Water Heater

Evaporator Coil Installation Instructions

Installation Manual. Thermomax Solar Water Heater ... Installation Procedure for Flatroof and Ground. Revision 8

OTF Oil Fired Pool Heater

Finding and Fixing Oil leaks on the LT5 Engine Marc Haibeck


Backup Sump Pump Systems. 1 NEXT

Laddomat Charging unit

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

SMD Rework Station TABLE OF CONTENTS

MODEL INSTALLATION INSTRUCTIONS

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

Solar Pool Heating Proposal

Isotemp Basic, Slim/B & Slim Square

RESERVDELSLISTA NORMFINISH DP14

Puddle Flange. FRANK Puddle Flange

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Peasouper Operator s Manual

Select Radiators Installation Guide

Assembly Instructions for the InteliTrack 3000 Rail Tracking System

Spare Parts List M96A.24SM/B M96A.28SM/B

SELECTION, APPLICATION AND MAINTENANCE

Making Your Home Ready For Solar Water Heating

FullFloXF. 2-Way and 3-Way Diverter Valve and Check Valve. Installaton and Operation Instructions

TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL

valid as of 1 April 2014 Intec injection hose system

GL-235 Solar Pool Controller

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

Transcription:

OKU solar heating for swimming Pool Instruction for installation an operating Introduction Solar heating for swimming pools with OKU-Absorbers normally will be operated with a direct circuit. The water from the pool will be pumped directly through the absorbers. The use of a heat exchanger is not necessary. Different configurations of OKU swimming pool solar heating A) Operation with filter pump via three-way motor ball valve with difference-temperature regulation This configuration can usually be selected if the absorbers are not to be set up higher than 6 m above the surface of the water. The threeway motor ball valve is integrated into the pressure line of the filter installation. Because of the difference-temperature regulation the ball valve is changed over when the absorber temperature is higher than the temperature of the water of the swimming pool. The filter stream is then pumped through the absorbers. The warmed water flows back into the filter circuit by way of a tee. B) Operation with own pump an difference temperature regulation integrated into the filter circuit In many cases it may be sensible or even necessary to install a separate pump for the solar heating. For example when the delivery head from the water level to the absorber panel is more than 6 m. The water is diverted from the filter installation by way of a tee and pumped through the absorbers by the auxiliary pump. This pump is switched on by the difference-temperature regulation to ensure that it only runs to actually win energy. The filter and solar pump are separately regulated. It is usually advisable to integrate non-return valves in both the solar and the filter circuit. C) Operation with own pump and difference-temperature regulation - piping independent of filter circuit This configuration is chosen when the filter piping is difficult to access. The water is sucked out of the swimming pool by an immersion pipe, pumped through the absorbers, and the warmed water is conducted back into the swimming pool. Here again the difference temperature regulation ensures that the pump only runs to win energy. If the pump is mounted above the water level and the delivery head is more than 5 m, a non-return valve should be incorporated. ) OKU-Absorber 5) Three-way motor ball valve 9) Stop cock (downdraft brake) ) Difference-temperature regulation OE 6) Temperature sensor, absorbers 0) Drain cock ) Filter installation 7) Temperature sensor, swimming pool ) Pump for solar circuit ) Solar circuit forward and return 8) Vent valve ) Non-return valve The water of the swimming pool can flow through the OKU absorbers in either direction, so they can be mounted both lengthwise and side by side. The individual rows of absorbers are connected on a Tichelmann principle (same routes for each row). It is not advisable to connect more than ten absorbers in series.

Example according to version A) We recommend to read the following instructions thoroughly before starting the installation and to make a plan of how to connect the absorbers in case your arrangement of absorbers differs from the example shown below. This example represents a system with 6 OKU absorbers in lines at items. Depending on the size of your swimming pool and the area available for the absorbers, numerous other schemes of installation are also possible. Warning: flow rate maximum 50 Liters / hour per panel Operation with filter pump via three-way motor ball valve with difference-temperature regulation 6 8 8 00 00 0 000 0 0 5 9 7 ) OKU absorber 5) Three-way motor ball valve 9) Stop cock (downdraft brake) ) Difference-temperature regulator OE 6) Temperature sensor, absorbers 0) Drain cock ) Filter installation 7) Temperature sensor, swimming pool ) By-Pass ) Solar circuit forward and return 8) Vent valve If pump flow rate is higher 50 Liters/hour per panel, a by-pass must be installed, otherwise there is the risk of too much pressure in the panels. If not observed, a warranty will not be recognized

Operation with additional pump and difference-temperature regulator 0 8 8 6 6 00 00 00 00 0 00 00 00 00 00 0 9 0 7 ) OKU absorber 6) Temperature sensor, absorbers 0) Drain cock ) Difference-temperature regulator 7) Temperature sensor, swimming pool ) Pump for solar circuit ) Filter 8) Vent valve ) Non-return valve ) Solar circuit forward and return 9) Stop cock (downdraft brake) Pump flow rate maximum 50 Liters/hour per panel otherwise there is the risk of too much pressure in the panels. If not observed, a warranty will not be recognized

Installation of the system. OKU-Absorbers are supplied with a onesided closed header. If further connections are required to connect the absorbers parallel to one another, simply cut off the cap.. Place the OKU-Absorbers on the designated areas in the arrangement that is desired and connect them with hose connections and hose saddles according with the the scheme of connection. In case of steeper sloping roofs, roof fastenings must be carried out simultaneously to prevent absorbers from slipping away during installation.. To make circuit points for supply and return lines, glue the hose nozzle into the elbow or the socket and add it with the hose coupling on the absorber. If you use a pipe dia. 50 mm or bigger, you have to glue a reduction piece into place.. Vent valve (8): The vent valve must be installed vertically. Glue in connection correspondingly and screw in vent valve. panels mounted vertical panels mounted horizontal 5. Install -way valve (5) behind filter pump (). to the panels 5 to the pool 7

6. Put tee for collector flow line into pipe leading to the pool. Glue stop cock (9) - downdraft brake into flow line pipe. 7. Construct and fix flow line and return travel of collector (). If for winter a drain cock is needed, glue a reducing tee with reducing piece /" for the drain cock. 8. Regulation: Please take a look at the instruction for installation and operating for the difference-temperature regulation and the three-way motor ball valve in connection with the pump. Close attention should be paid to the manner of the electrical installation. Swimming pool systems have to be equipped with an earth leakage circuit breaker. Fix the difference-temperature regulator and connect it according to the wiring diagram. Use wires with cross-section x mm² to lengthen sensor adaptors. Temperature sensor panel ( 6 ): fasten panel sensor ( 6 ) to the panel Suncontrol Minisol, Solax, Digisol, Kombisol Suncontrol Minisol, Solax, Digisol, Kombisol Pumps that have more than 000W power intake Pumps that have more than 600W power intake and three-phase current pumps should install a security and three phase current pumps should install a security switch. switch Temperature sensor pool ( 7 ): Glue reducing tee with /" nipple for swimming pool sensor (7) into pipe coming from the pool and screw in sensor

5 Operating Instruction To start the system adjust the difference temperature to approx. or C and place the hand switch on automatic. For systems working with filter pumps adjust the filter cycle to the hours of sunlight. Installations with own pump work independently from the filter circuit. If after a few minutes the system still operates with air in it, close the stop cock (downdraft brake) a little until the water escapes at the intake nozzle and is free of air. The stop cock should now be left in this position. Additionally you can close the cover cap of the vent valve. Operating the system in winter OKU-Absorbers are frost resistant. Due to the pipes the system must be emptied in winter nevertheless. Usually systems that are emptied once they are switched off, do not need any further precautions. Advice to glue pvc pipes Glue pvc pipes only if they are absolutely dry. Water, condensation and humidity prevent a good connection. Do not glue under a Temperature of 5 C. The time for drying is approximately hours. Do not use the pvc pieces under pressure before that time. Clean ends and fittings with a cleaner. Glue both parts the same way. Use a flat brush. It s important to disperse the glue lengthwise from the inside to the outside. Directly after applying the glue, you have to plug ends and fittings together. Take off the surplus glue. Clean the brush with cleaner.

Fastening the panels on the roof 6 Warning: because of the thermal expansion, the panels may not be screwed to fastening surface. Thermoplastic material (HDPE) in comparison to metal and duroplastic proves to have a higher coeffient thermal expansion. For this reason, the fastening of the panels must be done in a flexible manner. In extreme cases temperature differences of up to 00 C may occur. For example, in summer as high as 80 C and in winter as low as -0 C. Calaculation Formula: Heat expansion = 0,0 mm x Length of Part x Delta T Example for OKU panel - Longitudinal change by 0 C temperature change 0,0 x, m x 0 C = 7,8 mm How to fasten on a tiled roof. Hook for tiled roof Art.N. Screw-in pipe clamp /" zinc plated with a rubber inlay Art.N. Perforated zinc plated tape; x Art.N 0 with a screw 5 x 6 Art.N. galvanized pipe /" or stainless steel 000 00 00 000 000 00 00 000 000 00 00 000 000 00 00 000,5 -,0 m

tiles 7 OKU-Solar panels N 000 and 00 rafter tiles OKU-Absorber Art. N 00 rafter

Fixation of OKU-Solar panels on a tile roof with universal mounting strap Item N F7 8 000 00 00 000 000 00 00 000 000 00 00 000 000 00 00 000

pantiles 9 OKU-Solar panels N 000 and 00 rafter pantiles OKU-Solar panels N 00 rafter

0 Fastening of OKU-Panels on flat roofs with set F 9 ring bolt innox steel rope innox tightener innox rope clamp innox OKU - Absorber OKU - panels Decke roof Dichtungsbahn sealing sheeting Attika oder Betonplatten fascia or concrete slab -,5 m

Proposal on site fastening of OKU-panels on flat roofs fom concrete Alu- rectangular pipe or rope OKU-panels Screw with anchor fitting concrete roof Alu- rectangular pipe or rope OKU-panels Screw with anchor fitting roof concrete slab Roof fastening on sloped roofs of slate or cement asbestos Fastening of OKU panels on slate or cement asbestos is similar to that of a tiled roof. However ring bolts must penetrate through the roofs layer and be screwed into the roofs fundement. For roofs with a wooden fundament, it is the same. Be sure to secure into the sheating and firring. In order not to crack slate or cement asbestos, it is important not to use the "hammer mode" when drilling. After securing the screws, it is advised to use a silicone sealing compound for best results.