Control units for vibratory feeders. Operating Instruction

Similar documents
Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

SX460. Generator Automatic Voltage Regulator Operation Manual

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Inductive Proximity Sensors

Thyristor-controlled power supplies and battery chargers

Electronic Pressure Switch EDS 300

Contents. Document information

Product and functional description

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Preset Counter signo 721

ACS-30-EU-EMDR-10-MOD

Original instructions Tina 3A/Aps Adaptor unit

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

HERZ-Thermal Actuators

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

CompactLogix Power Supplies Specifications

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Automatic Voltage Regulator User s Manual

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Manual. Solar Fountain Mobile Phone Charger

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Circuit Board Sensor Products

Instruction Manual for Operating Panel 301 and 302

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Power supply unit Model: PAC-SC50KUA

Knob Potentiometer with Switch

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Safety Manual BT50(T) Safety relay / Expansion relay

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Cross-beam scanning system to detect slim objects. 100 mm in

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

Tina 2A/B Adaptor unit

3753 en /b VE/B - VE/RG Va V riable speed drives

Safety technique. Emergency stop module BO 5988 safemaster

Inductive sensor NI10-M18-Y1X-H1141

EGSTON Standard E2xFxWx 12W

Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

MDC Series

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Floodlight Range Installation Guide

Safety Relays ESM/ESM-F

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Telefon (+45) Telefax (+45) Installation and operating manual

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Pluggable interface relays CR-P Pcb relays

Multifunction devices

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Oil and Coolant Circulating Heating System. Model - OCSM

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Speed Control Relays SX2

Contents. Safety Warnings... 1

Electronic, Digital and Mechanical Vibration Switches

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Analog Command Value Card Type VT-SWKA-1

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

TIG INVERTER INSTRUCTION MANUAL

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

WD-AMX Water Detection Controllers

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Quick Connect. quick - simple - efficient.

IO-RM3 3-Stage Relay Module

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

FEMA ELECTRÓNICA. Serie ISC SIGNAL CONVERTERS WITH GALVANIC ISOLATION. MODEL ISC-IAC for AC Currents ISC-IDC for DC Currents USER S MANUAL

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Drayton Digistat +2RF/+3RF

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Smile. The All-In-One Heating Controller

Modular I/O System Analog and Digital Interface Modules

Instructions for Safe Use

Addendum to the Operating Instructions

BB800 Off-Grid Solar System

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Transcription:

Operating Instruction Control unit for Vibratory Feeders With main voltage compensation and Track control REO-USA, Inc 8450 E 47th Street Indianapolis, IN 46226 USA Phone +1 (317) 899-1395 Fax +1 (317) 899-1396 http://www.reo-usa.com email: info@reo-usa.com Control units for vibratory feeders 605652_ATS110_EN_09-10.DOC 09/10

User Technical Safety Information This description contains the necessary information for the correct application of the product described below. It is intended for use by technically qualified personal. Qualified personnel are persons who, because of their training, experience and position as well as their knowledge of appropriate standards, regulations, health and safety requirements and working conditions, are authorised to be responsible for the safety of the equipment, at all times, whilst carrying out their normal duties and are therefore aware of, and can report, possible hazards (Definition of qualified employees according to IEC 364) Safety Instructions The following instructions are provided for the personal safety of operators and also for the protection of the described product and connected equipment.! Warning! Hazardous Voltage Failure to observe can kill, cause serious injury or damage Isolate from mains before installation or dismantling work, as well as for fuse changes or post installation modifications. Observe the prescribed accident prevention and safety rules for the specific application. Before putting into operation check if the rated voltage for the unit conforms with the local supply voltage. Emergency stop devices must be provided for all applications. Operation of the emergency stop must inhibit any further uncontrolled operation. Electrical connections must be covered The earth connection must be checked, for correct function, after installation. Specified Use The units described herein are electrical controllers for installation in industrial plant. They are designed for power adjustment on vibratory feed equipment. Contents User Technical Safety Information... 1 1.0 General... 2 2.0 Technical Data... 2 3.0 Declaration of Conformity... 2 4.0 Commissioning... 3 4.1 Assembling position... 3 4.2 Preliminary steps... 3 4.2.1 Important points... 3 4.2.2 Operating frequency of the feeder coil... 3 4.3 Settings... 3 5.0 Connections external... 4 6.0 Connections internal... 5 7.0 Dimensions... 6 1

1.0 General Electronic control units for stepless adjustment of vibratory feeder throughput. The control units are suitable for feeders with a vibrating frequency of 60 Hz (50 Hz) and 120 Hz (100 Hz). The vibrator frequency is selected by using an internal link-switch on the printed circuit board. The feeder throughput can be adjusted by using the integrated potentiometer. An enable input is available for Stop/Start operation from contacts or a supervisory control system. U min and U max trimmers are provided to limit the throughput adjustment range. An integral soft-start reduces jolting when the unit is switched on or enabled. An internal regulation loop eliminates main voltage variations. The enclosed version includes mains input and feeder output cables. In the front panel there is a mains switch and a throughput adjustment potentiometer. The potentiometer can be used to set the feed rate from 10...100%, it s also possible to reduce the range of output voltage by using the internal U min and U max trimmers. The Track-control operate with a PNP track-sensor that calls for product when the level is low and this causes the feeder to switch on and off after preset timedelays (t-on, t-off) have elapsed. 20 30 10 40 0 50 REO-USA INC. 3250 North Post Road Suite 132 Indianapolis, IN 46226 PH: 317-899-1395 FX: 317-899-1396 www.reo-usa.com Input Output X4 60 100 70 90 80 2.0 Technical Data Stock Code 6056 52 Supply voltage 110 V / 120 V, +/- 10 %, (factory setting) 220 V / 240 V, +/- 10 % Mains frequency 50/60 Hz Output voltage 20... 105 V, (factory setting) 40 210 V Output current 0,2 15 A max. Vibrating frequency 3000 (3600), 6000 (7200) (factory setting) Set point source Internal Potentiometer 0... 10 VDC, 22 kr 0(4)... 20 ma, 250 R Enable 24 V, DC, 5 ma Contacts Sensor supply 24 V, DC / 50 ma Construction IP 54 Operating temperature 0... 45 C Storage temperature -20... +70 C 3.0 Declaration of Conformity We declare that these products conform with the following standards and directives.: EN 61000-6-2 and EN 61000-6-4 in accordance with Directive 2004/108/EG. REO ELEKTRONIK AG, D-42657 Solingen 2

4.0 Commissioning 4.1 Assembling position! Please fasten the devices on a vibration-free underground and take care for sufficient air circulation. 4.2 Preliminary steps Check that the unit is correct for the local mains supply (rating plate information) and that it is correctly rated for the feed system. Connect the controller according to the connection diagram 4.2.1 Important points! When applications with frequently on and off cycles are required, use the intended enable input. It is prohibited to open the current circuit with a switch or a contactor while the feeder is running, because that may cause damage to the controller. 4.2.2 Operating frequency of the feeder coil It is possible that the current flowing through the coil will increase for a small frequency adjustment, and so this should be checked with a true RMS instrument for each new application as well as monitoring the coil for heat build-up. The coil should be designed for the correct operating frequency to prevent excessive current draw and the consequential overloading of the coil. 4.3 Settings Check the input voltage before switching on the controller. The controller is factory set to 110 V / 120 V input Voltage, in case of main supply of 220 V / 240 V, please remove the cover and turn the switches into 220 V / 240 V position. Check the Frequency of the Feeder and use the switch witch also can be found inside the controller for the right setting. U min and U max trimmers are provided to limit the throughput adjustment range, they are also located inside the controller. 3

5.0 Connections external INPUT OUTPUT X4 1 2 4 3 Sensor track control (X4) 1 2 4 3 1 = Output 24V DC 2 = 3 = GND 4 = Input INPUT OUTPUT 4

6.0 Connections internal adjustments 29 28 27 1 2 3 t Soft start PE PE PE 26 25 22 21 24 23 4 5 6 7 8 9 internal wiring Internal Potentiometer X11 X13 G T2 T1 X9 X10 X12 X5 X4 PE PE PE 26 25 22 21 24 23 4 5 6 7 8 9 link 10 Kohm switch Inhibit + - Input cable 0...+10 V 0(4)...20mA + - 24V external Output cable Main switch 1a 2a Housing 1 2 5

7.0 Dimensions Ø5,0 40 50 60 30 70 20 80 10 90 193 205 0 100 REO-USA INC. 3250 North Post Road Suite 132 Indianapolis, IN 46226 PH: 317-899-1395 FX: 317-899-1396 www.reo-usa.com Input Output X4 Ø5,0 153 131 23 6,5 6