White Paper Power Booster EDFA

Similar documents
Limiting factors in fiber optic transmissions

Large-Capacity Optical Transmission Technologies Supporting the Optical Submarine Cable System

Modulation Formats for High-Speed, Long-Haul Fiber Optic Communication Systems

Suppression of Four Wave Mixing in 8 Channel DWDM System Using Hybrid Modulation Technique

Large effective area non-zero dispersion shifted fiber in metro/provincial network environments

Making OSNR Measurements In a Modulated DWDM Signal Environment

Optical Amplifiers. Ericsson

Chapter 2 OPTICAL FIBER CHARACTERISTICS AND SYSTEM CONFIGURATIONS

Directly modulated CWDM/DWDM system using negative dispersion fiber for metro network application

Line Monitoring and Control in Subsea Networks

Four Wave Mixing in Closely Spaced DWDM Optical Channels

TransPacket white paper. CWDM and DWDM networking. Increasing fibre-optical network utilization and saving on switches/routers

Designing Fiber Optic Systems David Strachan

Field Measurements of Deployed Fiber

BOTDR Measurement Techniques and Brillouin Backscatter Characteristics of Corning Single-Mode Optical Fibers

Wavelength Division Multiplexing

Modeling and Performance Analysis of DWDM Based 100 Gbps Low Power Inter-satellite Optical Wireless Communication (LP-IsOWC) System

Simulation and Best Design of an Optical Single Channel in Optical Communication Network

1550 Video Overlay for FTTH

40-Gb/s Dense Wavelength Division Multiplexing Transmission System

Attaching the PA-A1-ATM Interface Cables

Module 13 : Measurements on Fiber Optic Systems

High Power and Low Coherence Fibre-optic Source for Incoherent Photonic Signal Processing

DWDM TESTING WITH A HIGH-POWER SLICED ASE COMB SOURCE

High-Performance Submarine Line Terminal Equipment for Next-Generation Optical Submarine Cable System: FLASHWAVE S650

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

In This Issue: How to Provide Subsea Capacity On Demand Africa Elevated To New Heights Back to the Future: Control of the Oceans and Beyond?

Georgia Tech 100G Center

Duobinary Modulation For Optical Systems

Simulation of Gaussian Pulses Propagation Through Single Mode Optical Fiber Using MATLAB . MATLAB

Dispersion penalty test 1550 Serial

Cabling & Test Considerations for 10 Gigabit Ethernet LAN

Introduction to Optical Link Design

High-Frequency Engineering / Photonics

Scalable Frequency Generation from Single Optical Wave

Fiber Optic Distributed Temperature Sensor (B-DTS)

HDO700 P FIBRE OPTIC TRANSMITTER

The Optical Submarine Repeater and Its Associated Technologies

Light Link Series 2 LT1550. Laser Transmitter with Erbium Doped Fibre Amplifier. Description. Features

Challenges in DWDM System Spectral Analysis By Laurent Begin and Jim Nerschook

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

Golden test for dispersion penalty 1550 Serial

FIBER OPTIC COMMUNICATIONS. Optical Fibers

Improving Chromatic Dispersion and PMD Measurement Accuracy

New Installation and Maintenance Tools for CWDM Networks

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

MTS/T-BERD Platforms Very Long Range (VLR) OTDR Module

Measuring and Compensating for PMD in High-Speed Optical Networks By Aaron Deragon and Jeff Ferry

Model GS Port Node 1 GHz with 40/52 MHz split

Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces

Splicing and Fiber Assembly Compatibility for Non-Zero Dispersion-Shifted Fiber and Standard Single-Mode Fiber

The Operation and Power Budget of Amplified Optical Networks for Aerospace Applications. FOHEC Conference May 2010

Optical Communications Analysis of transmission systems. Henrique Salgado Point-to-point system

DIGITAL TRANSMISSION AND CODING TECHNIQUES

How To Get A Better Signal From A Fiber To A Coax Cable

IEO 5701 Optical Fiber Communication Lecture 1

CWDM: lower cost for more capacity in the short-haul

Multiplexing. Multiplexing is the set of techniques that allows the simultaneous transmission of multiple signals across a single physical medium.

Introduction to Add-Drop Multiplexers

Fibre Channel Fiber-to-Fiber Media Converters

WDM Network Design -1

Laser-Optimized Fiber

LONGLINE 10Gbps 10km SFP+ Optical Transceiver

How To Connect A 10Gbps Sfp+ Bi-Directional Transceiver To A Single Mode Fiber With A Single Power Cell (Sfp+) To A Power Cell With A Power Source (Sf) (Sfl) (

Achievable Transmission Rates and Self-Interference Channel Estimation in Hybrid Full-Duplex/Half-Duplex MIMO Relaying

Delaware Valley SCTE Comparing RF-over-Glass to HFC. Bill Dawson VP Business Development ARRIS Access & Transport bill.dawson@arrisi.

Application Note SAW-Components

GLOBAL COLLEGE OF ENGINEERING &TECHNOLOGY: YSR DIST. Unit VII Fiber Optics Engineering Physics

AN INTRODUCTION TO DIGITAL MODULATION

This white paper will provide an overview of the underlying technology of Coherent DWDM and the advantages of the Arista 7500E Series DWDM solution.

Enhancing High-Speed Telecommunications Networks with FEC

HoW confident are You about Your connector cleanliness?

Use and Application of Output Limiting Amplifiers (HFA1115, HFA1130, HFA1135)

WHITE PAPER. Achieving Total Traffic Visibility in Enterprise and Carrier Grade Optical Networks

best Practices for troubleshooting WDm networks with an optical spectrum analyzer by Jean-Sébastien Tassé, Product Line Manager, EXFO

WDM-PON: A VIABLE ALTERNATIVE FOR NEXT GENERATION FTTP

Single or Dual Fiber for 100 Mbps over SMF?

Photonics for the Coherent CFP2-ACO Unlocking 100G and 200G for the Metro

Measuring of optical output and attenuation

OFS AllWave Zero Water Peak (ZWP) single-mode

Design and Analysis of Digital Direct-Detection Fiber-Optic Communication Systems Using Volterra Series Approach

Modultech MT-XDFx-xx192-08(04)CD 80 (40) km DWDM XFP module with built-in FEC wrapper Description

Simulation and Comparison of Advanced Modulation Formats for Wavelength Reuse in High-

Analysis and Improvement of Mach Zehnder Modulator Linearity Performance for Chirped and Tunable Optical Carriers

E-Option Multi-taps Conditioning at the Tap

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

Cisco - Calculating the Maximum Attenuation for Optical Fiber Links

Optical Fiber Amplifiers-Review

The Conversion Technology Experts. Fiber Optics Basics

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Dense Wavelength Division Multiplexing Pocket Guide WDM

DWDM. Tutorial. Prerequisite Training

SONET and DWDM: Competing Yet Complementary Technologies for The Metro Network

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA

2.488Gbps Compact Bi-Di SFP Transceiver, 20km Reach 1490nm TX / 1310 nm RX

10 Gb/s WDM-PON Using Downstream OFDM and Upstream OOK

Dual Fiber SFP Series

Application. Benefits. Contact us. Solution for Indoor TETRA coverage. TETRA/TETRAPOL Repeater RF/OF High Power. To ensure TETRA coverage everywhere

SFP+ LR 10G Ethernet 10km SFP+ Transceiver 10GBASE-LR / 10BBASE-LW

Cisco SFP Optics for Gigabit Ethernet Applications

Transcription:

1 Introduction White Paper Power Booster EDFA Extending Single-span Network Reach Updated December 2012 Geography often limits the ability to provision repeater sites between two remote terminal locations. For example, submarine links (island hopping, oil rigs), links spanning over large unpopulated areas (deserts, jungles, mountain ranges), and single-span disaster recovery solutions for enterprise storage systems. Even when it is not imperative, a single-hop solution is often desired as it reduces operational expenses and increases security. The optical networking industry is aligning itself to this growing need by searching for practical, realizable and cost-effective solutions. These include: advanced modulation techniques, improved FEC algorithms, or advanced optical amplification techniques. In this paper we focus on advanced optical amplification techniques, and show how they provide a costeffective method for increasing single-span system reach without requiring significant system redesign. 2 Technology Alternatives for Increasing the Span Limit Several technology alternatives exist to increase the span limit. Advanced modulation techniques are a common method for Ultra Long Haul (ULH) equipment manufacturers to increase fiber link length by improving the tolerance to Optical Signal to Noise Ratio (OSNR) and non-linear effects. The Non-Return to Zero (NRZ) data coding is still the most common and is a widely used coding technique in Metro to Regional optical networking applications. NRZ is the lowest cost technique, but in terms of OSNR and non-linear tolerance, it is inferior to options such as Return-to-Zero (RZ) or RZ - Differential Phase-Shift Keying (RZ- DPSK). However, these advanced modulation schemes are either still confined to the laboratory or implemented only in high-end ULH systems. Introducing even just RZ to an existing system will require a significant increase in capital expense. Another method to realize greater transmission distances is Forward Error Correction codes (FEC). FEC significantly increases the system margin by embedding extra data that is used to correct errors, at the expense of a slight increase in signal bandwidth. The most common FEC algorithm is G.709 Reed-Solomon (RS-FEC). Reach can be further increased by implementing other FEC algorithms such as enhanced FEC, super FEC, or breakthrough algorithms such as soft decision turbo product code FEC 1. FEC is an excellent low-cost method for increasing span lengths and is almost mandatory in today's competitive high-end optical networks. 2012 Finisar Corporation, 1389 Moffett Park Drive, Sunnyvale, CA 94089-1133, sales@finisar.com www.finisar.com

Advanced optical amplification techniques can also improve span power budget, without significantly modifying existing terminal equipment. Amplification solutions may include simply increasing the available output power of the standard booster, adding Distributed Raman Amplification (DRA) or using Remote Optically-Pumped Amplifiers (ROPA). Optical amplifier solutions often require increased day-one CapEx, but on a cost per-channel basis they are a good cost effective alternative. Increasing the standard booster power may be easily achieved by using Finisar's UltraSpan Power Booster EDFA - a special low gain, high output power amplifier placed after any existing booster. This stand-alone Power Booster is an excellent alternative for increasing system margin without major modification to existing equipment. Reach can be further improved with the addition of a stand-alone DRA. ROPA can also significantly increase the span power budget, but may not always be an option for pre-deployed fiber links which commonly do not have adequate flexibility to optimize the EDF placement. Since extending a single-span budget is an occasional but sometimes unavoidable requirement, it is advantageous for the system vendor to be able do this with existing equipment without system redesign and unnecessary additional capital expense to the terminal equipment. For today's systems, this can be easily achieved using a stand-alone Power Booster EDFA, DRA, and ROPA. In this article we will explore the design considerations of adding these modules to an existing system. 3 Increasing Span Limit Using Optical Amplifiers To increase the span limit using optical amplifiers, four configurations will be discussed. First, we will explore the limitation of existing standard booster and pre-amp configuration, then we will see how adding a Power Booster EDFA can help in multi-channel systems, and finally, how a DRA and ROPA can further improve the link budget. 3.1 Limited Booster Power Typically, the limiting factor in long links is OSNR. When the signal power received at the end of the link is reduced due to high span attenuation, the OSNR is also reduced. However, every transmission system has its minimum OSNR tolerance. Typical 2.5Gb/s and 10Gb/s NRZ transmission systems without FEC will have an OSNR tolerance of about 16dB and 21dB, respectively. When FEC is implemented, the bit-rate is increased to 2.7Gb/s and 10.7Gb/s, but the resulting OSNR tolerance will reduce to approximately 10dB and 13dB, respectively. These figures are practical boundaries (not including margins or penalties due to effects such as dispersion) of OSNR tolerances in the majority of deployed systems. For a single-span link containing a pre-amplifier and booster, as shown in Figure 1, the noise is mainly generated within the pre-amplifier. Figure 1: Single-Span with Booster and Pre-amplifier In this configuration the OSNR at the end of the link can be increased by increasing the booster output power - every db increase in booster power results in an immediate db improvement in OSNR. However, this can be done only to a limit, as non-linear effects will start deteriorating the signal when the launch power increases beyond a certain point. For a single-span, single-channel applications, a standard booster with output power of up to 20dBm is usually sufficient for maximizing the output power and hence the OSNR, but vendors should be aware of the non-linear limits of their system. The influence of non-linear effects will be discussed shortly. Finisar Corporation Page 2 of 7

3.2 Span Extension Using a Power Booster EDFA When the system includes more than one channel and the total output power is limited by the booster output power, the overall per-channel launch power is reduced by 10logN, where N is the number of channels. Therefore, to further increase the per-channel launch power to maximize link budget, a Power Booster EDFA can be added, as shown in Figure 2. This innovative amplifier can provide a desirable solution for many single-span applications, when designed from standard, mature and telecom-qualified single-clad EDF technology. Tx M U X Booster 20dBm Power Extender EDFA 3-6dB 23dBm- 26dBm Pre-amp DCF/M D E M U X Rx Figure 2: Single-Span link with Power Booster EDFA A standard booster has output power of 17dBm-20dBm, a Power Booster can be used to boost the total output power to 26dB, thereby increasing the per-channel signal power. However, for these power levels, non-linear effects begin to deteriorate the signal. Therefore, it is important to determine the maximum launch power limit of the signal. For a single-span transmission link containing few, broadly-spaced channels (up to 8), with 2.7Gb/s and 10.7Gb/s data rates, two non-linear effects are relevant: Stimulated Brillouin Scattering (SBS) and Self- Phase Modulation (SPM). The Four Wave Mixing (FWM) effect is usually negligible, and can be eliminated by avoiding low dispersive fiber or by distributing the signal wavelengths unevenly. When increasing signal launch power, the first non-linear effect that needs to be dealt with is SBS 3. In this effect, the optical signal interacts with density variations inside the optical fiber (caused by acoustic modes or temperature gradients) to create a reflected Stokes wave. This effect can add considerable noise to the signal, but is reduced significantly when the linewidth of the laser is broadened. For direct laser modulation, typically employed in 2.7Gb/s transmission systems, the optical linewidth is inherently broadened by the adiabatic chirp induced via the RF modulation. The SBS threshold in this case is above 16dBm launch power. For externally modulated transmission (2.7Gb/s and 10.7Gb/s), SBS backreflection occurs at relatively low powers since about half of the modulated signal power remains contained within the narrowband carrier signal. The maximum launch power in this case is limited to about 11dBm, but can be easily improved by increasing the laser linewidth using a low-frequency dither of the laser bias current. Laser dithering is common and can increase the SBS threshold for Distributed Feedback (DFB) lasers to approximately 18-19dBm launch power. For other types of lasers, even if dithering is used, the SBS threshold can still be significantly lower. The second effect to limit transmission is SPM. SPM occurs when the power modulation of the on-off keying signal, self-modulates the phase of the signal, thereby causing signal distortion. For 10.7Gb/s single-span transmission, SPM limits the launch power to roughly 21dBm, and for 2.7Gb/s, the SPM limit is well above this 4. In both cases, the maximum power in a single-span system is limited by SBS, and not by SPM. Therefore, the use of a Power Booster in single-span applications should be considered using the following criterion: For single-channel links - employ a standard booster without a Power Booster. For 2-6 channels links - employ Power Booster designed with output power of 18dBm+10logN, where N is the number of channels. For more channels and/or for additional link budget - employ a DRA in addition to the Power Booster, as described in the next section. Finisar Corporation Page 3 of 7

3.3 Further Increasing the Limit using a DRA If the link budget is high, or the link uses a large number of channels, an "extra push" may be required. This push can employ a counter-propagating DRA 5 at the receiving end as shown in Figure 3. Figure 3: Single-span link with booster, Power Booster EDFA and DRA and pre-amp Most the noise in the single-span configuration is generated within the DRA and pre-amplifier at the end of the link. To calculate the OSNR, a link-model is used, as shown in Figure 4. This model shows a link (see Figure 3), containing a booster, Power Booster, DRA, and pre-amp, in a schematic way. Figure 4: Model for calculating the link budget and OSNR In this configuration, and assuming the insertion loss and NF of the DRA are 1.5 db and -2dB, respectively, the overall OSNR improvement using a 700mW DRA is approximately 5.5dB, and using a 1400mW DRA, the improvement is more than 7dB 4 Very Long Spans Using ROPA ROPA uses a passive Erbium-doped fiber (EDF) module placed deep within the fiber span to amplify the signal at a point where it is still relatively strong, thereby increasing the OSNR at the link end. As shown in Figure 5, the passive EDF is remotely pumped using a pump unit placed at the receiving terminal. This pump unit provides 1480 nm pump power (as well as Raman pump power at other wavelengths) which propagates along the transmission fiber to the passive EDF, thus providing the pump power required to amplify the signal. Figure 6 shows a typical model for calculating the link budget of a system including a ROPA, including the following elements: multi-channel transmitting terminal, transmission fiber, remote EDF module, additional transmission fiber, receiving terminal including the ROPA pump unit and a pre-amplifier. Figure 5: System implementation of ROPA Figure 6: Model for calculating the link budget and OSNR for a Span with ROPA Finisar Corporation Page 4 of 7

The link gain provided by ROPA is about 10dB more than the configuration with the 1.4W Raman. If further link increase is required then one can use also a co-propagate Raman on at the transmitting terminal d with or without the Power Booster. 5 Single Channel Transmission Example As the maximum launch power of one channel is limited to roughly 18dBm due to SBS, the use of a Power Booster for single-channel transmission is not required. The maximum link budget for common 10.7Gb/s systems can be seen in Figure 7. Without DRA, the maximum distance of a 10.7Gb/s system is 285km. When a DRA is used, the distance can be extended to320km. When ROPA is used the distance increases to 370km. The assumptions in these calculations are: System margin is not accounted for and will be added as required by the designer. Fiber attenuation is roughly 0.2dB/km, suitable for pure silicon core (PSC)-type fiber (0.18dB/km) + 0.1dB splice every 5km. Raman amplifier gain is 30dB. To reduce dispersion penalty, the dispersion is optimally compensated. Transmission is NRZ with FEC. Figure 7: Single-channel maximum transmission without Power Booster EDFA: a) extended using DRA b) extended using ROPA 6 Multi-Channel Transmission Example For systems containing 2-6 channels, an additional Power Booster with 3-6dB gain and DRA can be used to achieve similar reach improvement performance, as shown in Figure 7. The assumptions here are that: The transmit power per-channel is 18dBm (similar to the one-channel case). If more than 6 channel are used, than the per power channel will be less than 18dB, and the link budget will decrease accordingly. There is no non-linear interaction between the channels Any tilt introduced by stimulated Raman scattering (SRS) interaction between the channels can be corrected via pre-emphasis to achieve optimal OSNR per channel. Over 6 channels, non-linear effects do not limit the ability to use the maximum available gain of the Power Booster EDFA (PB), 6dB, since the power per-channel is below 18dBm. Therefore, the overall reach of a multi-channel system can be significantly improved by adding the Power Booster EDFA. Figure 8 shows the benefit of using the Power Booster EDFA in an 8-channel transmission system a typical channel-count limit for disaster recovery WDM storage area networks. If a standard booster with 20dBm output is used, the average launch power per-channel is roughly 11dBm. Without PB and DRA, the maximum distance for 10.7Gb/s transmission is 250km,. When PB, DRA and ROPA are added, the span length may be increased to 280km, 315km and 365km, respectively. This is an increase of 115km over the conventional booster-preamp configuration Finisar Corporation Page 5 of 7

SBS Limit SBS Limit Power 250km 280km 315km PB DRA Power 250km 280km ROPA Gain PB 365km ROPA OSNR Limit OSNR Limit Distance (a) Distance (b) Figure 8: 8-channel maximum transmission with (solid line) and without (dashed line) Power Booster EDFA: a) with DRA. b) with ROPA. Any link designs containing regular SMF fibers (typically 0.22dB/km) and a 3dB span margin, must adjust these span limits by roughly 50km downwards. Therefore, typical applications of Power Booster EDFA and DRA begin at approximately 200km. 7 Deployment Issues DRAs are already deployed world-wide, and provide a good solution for difficult spans. Deployment issues of DRA have been discussed in previous articles 5. Here we will discuss the new issues surrounding the Power Booster EDFA solution. As this amplifier operates at high power levels, there are three technical issues that need to be solved: 1. Eye safety similarly to Raman amplifiers operating with similar output powers, this amplifier must shut down in case of fiber cut. 2. Line quality similarly to Raman amplifiers, the line quality must be monitored to ensure connectors are not damaged due to the high signal power. 3. Non-linear effects one needs to know the boundaries of launch power for linear transmission to ensure that this amplifier does not introduce non-linear signal degradation. The first and second challenges can be dealt with in the same way as with Raman amplifiers 5. Without eye safety mechanisms the IEC 60825 standard 6 defines the 26dBm Power Booster amplifier as a Class 3B laser product. If designed with reliable eye safety mechanisms, this amplifier can be compliant as a Class 1M hazard level as required for optical communication. This is achieved by reducing the power output of the amplifiers within 150ms after a connector is opened or a fiber break occurs Since the output power of the Power Booster is very high, damage can occur in faulty lines. Any undesired attenuated, bent or pressed fiber, dirty connectors, or connectors with air gaps in-between can cause damage which is difficult to detect and repair. The third challenge, regarding knowing the non-linear limits of the link, was discussed previously in a general way but must be reconsidered individually for each specific system. Finisar Corporation Page 6 of 7

8 Summary The Finisar UltraSpan Power Booster EDFA, uses standard and mature, telecom-qualified, single-clad EDF technology specially designed to achieve a high output power of up to 26dBm. This innovative product also features state of-the-art transient suppression, patent-pending line monitoring and eye safety mechanisms, and a Class 1M laser product classification according to IEC 60825-1. The UltraSpan Power Booster is a stand-alone 1RU rack-mountable network element that can be used to boost the output power for any existing system. The need to cater to applications where a single-span link is unavoidable or has significant operational or cost advantages has already driven the industry to move towards DRA solutions, such as Finisar's UltraSpan Network Interfaced Raman amplifier. The UltraSpan Power Booster solution adds additional link budget which is comparable to DRA. These specialized products cater to the growing need to extend the reach of existing links. The combination of these two products can increase single-span distances by up to 65 additional kilometers, which could prove critical for certain applications. An addition of ROPA will allow to traverse an additional 50km. Studying the economics of fiber amplifiers, one can conclude that system upgrades for single-span links of 200km and above and containing few channels are best performed in the following logical steps: The system vendor must first consider Finisar's UltraSpan Power Booster EDFA for extending the limit by roughly 30km; and then if an additional 35km are required, upgrading the system using Finisar's UltraSpan Network Interfaced Raman amplifier. If longer links are needed, and where possible to add a passive EDF module, the vendor should consider using ROPA which will add an additional 50km to the span. Although this article covers the specific application of single-span networks, Finisar's Power Booster EDFA can be used to achieve margin improvement and reach extension also in multi-span networks. 9 Further Reading 1. T. Mizuochi et. al., OFC 2003, ThN1, pp. 527-8. 2. P. C. Becker, "Erbium-Doped Fiber Amplifiers", Academic Press. 3. D. A. Fishman et al. J. Light. Tech., 11, Nov. 93. 4. J. P. Elbers et al. IEEE J. of Selected Topics in Quantum Electronics, 6, 276-281, 2000. 5. D. Menashe, "Applications for Distributed Raman Amplifiers", White Paper, Feb. 2006. 6. "Safety of laser products part 1 Safety of laser products", IEC International Standard 60825-1. For more information please contact sales@finsiar.com. Finisar Corporation Page 7 of 7