Preparation. Sample. Solid Phase Extraction (SPE) SPE Vacuum Manifolds SUPELCO

Similar documents
ORGANIC SAMPLE PREPARATION

CataLoG No. weight o.d. i.d. GLaSSwaRe

SciTech, sro Praha Ceník Jour Research tisk

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

How To Replace A Reverse Osmosis Water Tank

REPAIR AND MAINTENANCE MANUAL

National- Spencer Inc.

Installation Instructions

Mitos P-Pump. product datasheet

MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK

INSTRUCTION. Industrial Sewing Machines. No First published : June 1997 Second edition : March 2001

Flow Solution Parts & Accessories

ArtisanLink Staining System is an automated special stains slide

FREE SAMPLE PACK Just ask.

Installation Instructions

UNITOR VACUUM cleaners

AIRFREE TECHNIQUE AND SENSITIVE REAGENTS S ECTI O N 1: GLASS W ARE A ND E Q UIP M ENT. A. Using a manifold

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Fixtures - Parts - Accessories to shampoo bowls

NITROUS TRANSFER PUMP INSTRUCTIONS

Installation Instructions S

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

INSTRUCTIONS. FLHR/C/S (Road King) FRONT END LOWERING KIT 1WARNING -J03242 REV General. Removal (Left and Right Forks) Kit Number

15CI and 25CI Reversing Motor Pumpset Owner's Manual

Stainless Steel Single and Dual Circulation Kits

Experiment 12- Classification of Matter Experiment

COMMON LABORATORY APPARATUS

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

globe reactions made easy Process perfection

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Purification of reaction mixtures using flash chromatography.

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

AIR LINE VALVES AND GAUGES

Unit 24: Applications of Pneumatics and Hydraulics

Multiple flasks. Easy to adapt. Stuart range of heating blocks

CHEMICAL CLEANING UNIT Product number:

ab vacuum manifold for 96 well filter plates This product is for research use only and is not intended for diagnostic use.

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)


Thermo Scientific Nalgene Analytical Filtration Products

ReadyKart Mobile Processing Station Instructions for Use

Many Products...One Source

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

WHATMAN ÜRÜN LİSTESİ 1 / 53 KATALOG NO AMBALAJ ŞEKLİ. Labsciences

Probably the best Speed Vacuum Concentrators in the world

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

ISOLATION OF CAFFEINE FROM TEA

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Samco Scientific Liquid Handling Solutions

Solids, Volatile Dissolved and Fixed Dissolved

Solstice/Sky Water Pump Replacement

not appearance. ADHESIVE SYSTEMS CORIAN As an integral part of its sheet and shape products, DuPont has developed a special adhesive.

SHOT BLAST CABINET MODEL NO: CSB20B

Flash Chromatography, Synthesis and Work-up Products

Isolation of Caffeine from Tea

Rheodyne Manual Sample Injector Valves

MODEL G300 BRAKE BLEEDER

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Unit 24: Applications of Pneumatics and Hydraulics

105 Adopted:

Mixtures and Pure Substances

Jay R. Smith Mfg. Co.

NIH Clinical Center Patient Education Materials Giving a subcutaneous injection

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

FOR ANY QUESTIONS, PLEASE CALL M-F 8:00a.m.-8:00p.m. EST. REAR BRAKES 1 AEROSPACE COMPONENTS

Watts Pure Water Systems

MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC

Fuel Injection Pump, Rotary ( )

Procenter Delivery System* Troubleshooting Charts

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

Aseptic Technique. A GMP/GTP Training Module

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

2006 HEADSHOK Service Video #1

Recharge Procedure for Telemark TVP-2000 and TVP-3500

INSTRUCTIONS Edition AC

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions

Gas Chromatograph GC Consumables. p/n:

World Class Equipment worldwide Edition J

MOISTURE (Karl Fischer, Buffered)

Helping to protect you from exposure to hazardous drugs

The Strange Effects of a Vacuum

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

CutMaster Major External Replacement Parts

CHROME FRONT BRAKE MASTER CYLINDER KIT

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

Before repairing your toilet, you must determine

Professional Precharged Hunting Rifle

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Sample Collection Procedures for Insulating Fluid Samples

11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50

Joplin Rebuild Instructions

Extraction: Separation of Acidic Substances

#12 Professional Meat Grinders

YELLOW JACKET Hose Adapters, Valves, and Parts right to the last detail

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Transcription:

64 Solid Phase Extraction (SPE) SPE Vacuum s Visiprep SPE Vacuum s Visiprep Solid Phase Extraction Vacuum s allow you to simultaneously process up to 2 or up to 24 SPE tubes. Precise flow control is provided through each SPE tube by rotating the independent, screw-type valves in the cover. This precise control ensures the packing will not dry out in some tubes while others finish draining. A solvent-resistant vacuum bleed gauge and valve offer better sealing and vacuum control, via a screw-type mechanism fitted with a Teflon seal. The stand-alone cover with legs prevents the Teflon solvent guides from resting on the work surface and becoming damaged or contaminated. The glass basin will not dissolve, fog, or discolor when exposed to solvents, and an optional polypropylene splash guard inserts into the basin to eliminate splashing. The polypropylene collection vessel rack accommodates autosampler vials, small scintillation vials, 0mm and 6mm test tubes, and ml, 2mL, 5mL, and 0mL volumetric flasks. An optional plate for the 2-port model enables you to collect samples in up to ten 20mL scintillation vials. A Visiprep DL (Disposable Liner) Solid Phase Extraction Vacuum eliminates the possibility of contamination from one sample to the next in the same manifold port. A disposable Teflon solvent guide runs through each flow control valve. The guide acts as a liner, ensuring that all surfaces that come in contact with the sample can be replaced following each extraction. The guide consists of two parts: a polypropylene luer hub which attaches to the SPE tube and the thin-walled length of Teflon tubing that acts as the liner/solvent guide. The luer hub fits snugly into a matching slot on the flow control valve stem. As the SPE tube is rotated, the valve pinches or releases the liner, stopping or starting flow. Includes 00 liners. VISIPREP SOLID PHASE EXTRACTION MANIFOLD 2-Port Model 57030-U 24-Port Model 57250-U VISIPREP DL (DISPOSABLE LINER) SPE VACUUM MANIFOLD 2-Port Model 57044 24-Port Model 57265 Long Stem Flow Control Valves Equip alternate valves in your 2-port or 24-port Visiprep vacuum manifold with these long stem flow control valves if you intend to use all ports of the manifold with 2mL, 20mL, or 60mL tubes. Not for use with DL manifolds. Long stem flow control valves (pk. of 6) 57048 57044 57250-U 57030-U 24-Port Visiprep Vacuum 2-Port Visiprep Vacuum 2-Port Visiprep DL (Disposable Liner) Vacuum P00029 P00030 P000844

Solid Phase Extraction (SPE) SPE Vacuum s 65 Chemicalresistant Cover 5760-U PlatePrep Vacuum P000845 The PlatePrep vacuum manifold consists of a clear acrylic top allowing for easier inspection of flow rates during SPE 96-well plate processing. The polypropylene base offers excellent chemical resistance while a single remote vacuum gauge/bleed valve controls flow through all the wells. Use this compact vacuum manifold in conjunction with a Discovery SPE 96-well plate to process up to 96 samples concurrently. The single valve control, parallel processing capabilities, and uniform flow dynamics allow for easier method development, reduces clutter, and allow for greater reproducibility. Unused wells can be covered and used at a later date. Starter Kit Includes: PlatePrep Vacuum 96 Sq. Well Collection Plate, 2mL, PP 2 Disposable Reservoir/Waste Trays, PVC 96 Sq. Well Piercable Cap Mat 5 Reagent Reservoirs Cluster Tube Rack DESCRIPTION QTY. CAT. NO. PRICE Supelco PlatePrep Vacuum 5792-U 96-Well Plate Starter Kit with PlatePrep 575650-U PLATEPREP VACUUM MANIFOLD REPLACEMENT PARTS Acrylic Clear Top 5793-U Polypropylene Base 5794-U Gasket/Connector Replacement Kit 5795-U Remote Vacuum Gauge/ Bleed Valve Assembly 576-U 96-WELL SPE ACCESSORY ITEMS 96 Sq. Well Collection Plates, 0.35mL, PP 50 57565-U 96 Sq. Well Collection Plates, ml, PP 50 575652-U 96 Sq. Well Collection Plates, 2mL, PP 50 575653-U Disposable Reservoir/ Waste Tray, PVC 25 575654-U 96 Sq. Well Piercable Cap Mats 50 575655-U Reagent Reservoirs 00 R9259-00EA Cluster Tube Rack Z372226-PAK Supelco Preppy Vacuum Glass Basin Rotate Knurled Knob for Slow Flow Solvent Packing Bed P00028 The Preppy manifold is our simplest and most economical manifold. It too enables the analyst to simultaneously prepare up to 2 samples. It consists of a chemical-resistant cover and gasket, a glass basin, a vacuum release vent, 2 individual control valves with knurled tops, and stainless steel solvent guide needles. Two optional collection racks are available; one holds both and 4mL autosampler vials, and the other holds 2 or 20mL vials. An optional vacuum gauge/bleed valve assembly can be installed to allow precise control of the vacuum used with the Preppy manifold. PREPPY VACUUM MANIFOLD 2-Port Model 5760-U PREPPY REPLACEMENT PARTS Cover with flow control valves and solvent needle guides 5758-U COLLECTION VESSEL RACKS For or 4mL vials 5759-U For 5 or 20mL vials 5762-U ACCESSORIES Vacuum Gauge/Bleed Valve Assembly 576-U Single SPE Tube Processor Visi- processor provides two rates of flow control Our Visi- Single SPE Tube Processor provides precise flow control through a single ml, 3mL, or 6mL SPE tube. There is no faster, more convenient, or more reliable method for processing one or a few samples. Simply fill the SPE tube with the appropriate solution, attach it to the Visi- processor, and rotate the knurled knob clockwise. The solution will pass through the tube in a slow, uniform rate, consistent with the most reproducible results for SPE. Use the plunger to expel the last drop of Depress Plunger for Rapid Flow solvent from the tip of the tube. Remove the tube from the processor, introduce the next solution, and repeat the process. Visi- Single SPE Tube Processor 57080-U 730539

66 Solid Phase Extraction (SPE) Vacuum Accessories Replacement Parts and Optional Components for Visiprep s FOR 2-PORT MANIFOLD Cover, 2 flow control valves, gasket 5703-U Cover, 2 DL flow control valves, gasket 2 57029 Gaskets (pk. of 2) 57033 Glass basin 57049 Glass basin, vacuum gauge and bleed valve 3 57034 Collection rack (base, 3 support rods, center plate, 0mm test tube plate, 2 retaining clips) 3 57037 Plate for /2/5/0mL volumetric flasks 3 57038 Plate for 6mm test tubes 3 57039 Plate for 2mL autosampler vials 3 57040-U Plate for 20mL scintillation vials 57043 Splash guard 57045-U FOR 24-PORT MANIFOLD Cover, 24 flow control valves, gasket 4 5725 Cover, 24 DL flow control valves, gasket 5 57266 Gaskets (pk. of 2) 57254 Glass basin 57253 Glass basin, vacuum gauge and bleed valve 6 57252 Collection rack (base, 2 support rods, center plate, 0mm test tube plate, 8 retaining clips) 6 57255 Plate for 6mm test tubes 6 57257 Plate for 2mL autosampler vials 6 57258 FOR 2-PORT OR 24-PORT MANIFOLD Flow control valves (pk. of 2) 7 57032 Solvent guide needles, Teflon (pk. of 2),8 57047 Solvent guide needles, stainless steel (pk. of 2) 7 57036 Disposable liner flow control valves (pk. of 2) 9 57028 Liner guide needles, stainless steel (pk. of 2) 2,0 57027 Disposable valve liners, Teflon (pk. of 00) 2,5 57059 Vacuum gauge and bleed valve 57035-U Retaining clips for collection racks (pk. of 2) 5704 Test tubes, 0 x 75mm (pk. of 2),2,8,0 57042 Included with 57030-U 2 Included with 57044 3 Included with 57030-U and 57044 4 Included with 57250-U 5 Included with 57265 6 Included with 57250-U and 57265 7 For 57030-U and 57250-U 8 2 packages included with 57250-U 9 For 57044 and 57265 0 2 packages included with 57265 P00035, P00043 57047 5704 57036 57256 57027 57257 57032 57042

Solid Phase Extraction (SPE) Vacuum Accessories 67 Drying Your Tube Packing Gas Flow Path Visidry Drying Attachment Evaporating Your Collected Gas Flow Path 5724 Tube Adapters Lid Packing in tube is dried with an inert gas. Components in collection vessel (liquid evaporated) Visidry Drying Attachment The Visidry Drying Attachment was designed for our Visiprep Vacuum (Cat. No. 5700-U also fits our economical Preppy manifold). The Visidry unit installs in minutes, dries up to 2 or up to 24 SPE tubes at one time, and can be used with any inert gas supply. It is also useful for evaporating and concentrating recovered samples. Gas flow to each port can be independently adjusted. NOTE: The Visidry drying attachment cannot be used to dry 2mL, 20mL, or 60mL SPE tubes. VISIDRY DRYING ATTACHMENT 2-Port Model 5700-U 24-Port Model 5724 REPLACEMENT PARTS FOR VISIDRY DRYING ATTACHMENT Control knobs (pk. of 2) 57095 Retaining C clips (pk. of 2) 57096 Female luer plugs (pk. of 2) 57098 G000365,6 Collection Vessel Rack in P000846 24-Port Model 2-Port Model 57030-U (order separately) 5700-U Long Stem Flow Control Knobs If you have equipped your Visiprep Vacuum with long stem flow control valves, these control knobs will enable you to attach the Visidry Drying Attachment without removing the long stem valves. NOTE: These knobs cannot be used with a 24-port manifold being used to process 2mL, 20mL, or 60mL tubes. Long Stem Flow Control Knobs (pk. of 6) 57093 P00020 P0000

68 Solid Phase Extraction (SPE) Vacuum Accessories Visiprep Large Volume rs for Direct Extraction For continuous hands off direct transfer of multiple liquid samples A Visiprep large volume sampler enables you to transfer low viscosity samples directly from any sample container to conventional solid phase extraction tubes on a Visiprep SPE vacuum manifold. Two samplers are available. One sampler has three tube adapters compatible with 2mL, 20mL, or 60mL polypropylene SPE tubes. Simultaneous extraction of 2 samples on a 2-port Visiprep manifold requires four of these samplers. The other sampler has four tube adapters for 3mL or 6mL SPE tubes. To simultaneously extract 2 samples, three samplers are required. The samplers consist of /8-inch Teflon tubing with a screw fitting at one end and a stainless steel weight at the other end. To use the sampler, feed the weighted end into a sample container until it touches the bottom. Insert the tube adapters into the conditioned SPE tubes on your Visiprep manifold. Turn on the vacuum to the Visiprep manifold and open the manifold flow control valves, and the samples will be delivered to the SPE tubes. The flow rate of sample through each tube can be independently controlled by using the flow control valves. Both the screw fittings and the Teflon tubing on the samplers are colorcoded for easy sample identification. Also fits Preppy SPE Vacuum. VISIPREP LARGE VOLUME SAMPLER for 2mL, 20mL, or 60mL SPE tubes (3 adapters) 57272 for 3mL or 6mL SPE tubes (4 adapters) 57275 REPLACEMENT PARTS /8" Teflon tubes, color-coded (pk. of 4) 57276 Nuts and ferrules, color-coded (pk. of 4) 57277 Stainless steel weights (pk. of 4) 57278 TUBE ADAPTERS, /4-28 THREADS For 3mL or 6mL tubes (pk. of 4) 57273-U For 2mL, 20mL, or 60mL tubes (pk. of 3) 57274-U Also, you must equip alternate manifold valves with long stem flow control knobs to accommodate 2mL, 20mL, or 60mL SPE tubes. 57275 Teflon Tubing Tube Adapters Stainless Steel Weight 5760-U (order separately) P00032 Vacuum Guage / Bleed Valve Assembly Install in-line to allow control of vacuum Vacuum Guage / Bleed Valve Assembly 576-U 5720-U 2043-U Trap Kit for SPE Vacuum s Trap Kit for SPE Vacuum s When installed between a Visiprep SPE vacuum manifold and the vacuum source, a Supelco SPE Vacuum Pump Trap collects all liquids that are aspirated through the SPE tubes, preventing contamination of the vacuum pump. The easily assembled kit contains a polypropylene filtering flask, a one-hole rubber stopper, 4" (0cm) of polypropylene tubing and 5' (.5m) of red rubber vacuum hose. SPE Vacuum Pump Trap Kit 5720-U P000 P000 SPE Elution Rack This versatile stand-alone elution rack can be used with a variety of SPE tubes and receiving vessels, for simultaneous gravity feed extraction of up to 2 tubes. When using reversible tubes with luer endfittings, you can attach an empty syringe barrel to the tube to serve as a solvent reservoir. By assembling the plates in appropriate combinations, you can configure the rack to accept the following: ml, 3mL, or 6mL syringe barrel-type tubes Closed cartridge (reversible) tubes 5mL or 0mL volumetric flasks 2mL or 4mL vials Test tubes up to 5mm ID x 0cm SPE Elution Rack 2043-U P00002

Solid Phase Extraction (SPE) ENVI-Disk Accessories 69 ENVI-Disk Holder 5774 Funnel Teflon Base/ Adapter Flask (order separately) ENVI-Disk Holder 5773 Use the ENVI-Disk Holder with 47mm ENVI-DSK SPE disks. The unique design of the holder allows each disk to be installed and held firmly in place without wrinkling or tearing. A screw clamp provides uniform pressure on the disk and the sealing surfaces to prevent troublesome leaks spring-loaded clamps cannot offer the sealing integrity of the ENVI-Disk Holder. P0006 The unit consists of a -liter sample funnel, a threaded screw clamp, a Teflon disk support, and a Teflon filter base/adapter with a vacuum attachment fitting. The filter base fits onto any 57260-U standard -liter flask that has a 40/35 tapered ground glass neck. Use 25 x 250mm test tubes to collect disk eluates. The flask and 58068 collection tubes are not included with the holder, but can be purchased separately. ENVI-Disk Clamp To use the holder, place the base/adapter on the -liter flask and Eliminates leaks center an ENVI-Disk on the disk support in the base. Loosen the Attaches to any 34/45 tapered flask screw clamp to install the funnel, then tighten to secure the unit. ENVI-Disk Holder 5773 Flask, -liter, 40/35 fitting Z29060-EA Collection Tube, 25 x 250mm 5775 Order separately not included with holder. P0005 ENVI-Disk Holder The ENVI-Disk Holder holds one to six ENVI-Disk Holders with flasks, allowing you to simultaneously extract up to six -liter samples. Each of the six stations is controlled through an independent flow control valve. These valves are designed to vent the flask to the atmosphere when moved from the open to the closed position. The flow rate is controlled by the needle valve on the manifold. The unit includes a sturdy polymer base with six stations, six flow control valves, a needle valve, a vacuum gauge, and vacuum tubing. A -liter glass bottle in the manifold acts as a trap, to protect the vacuum source in the event of an overflow from one of the sample flasks. ENVI-Disk Holder 5774 When used with a standard 47mm glass filtration apparatus, the Attach the base/adapter to a vacuum source, and the unit is ready ENVI-Disk Clamp creates a better seal, eliminating leaks with to use. SPE extraction disks or when filtering HPLC mobile phase solvents. Use only with a filtration glassware funnel base that has a removable filtration stage, such as Supelco Mobile Phase Filtration Apparatus (Cat. No. 5806) or 2 (Cat. No. 58062-U), or with a funnel base (Cat. No. 58064 or 58068). It cannot be used with a permanent fritted glass filtration stage or stainless steel holder screen. ENVI-Disk Clamp, 47mm assembly 57260-U Replacement Teflon stage 5726 P0000