HV Substations Switchgear

Similar documents
Trapped Key Interlocks for. Switchgear. Applications Guide.

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

High-Voltage GIS yesterday - today - tomorrow

Advantages of Fixed Circuit Breaker Switchgear

Trapped Key Interlocks

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

The Intelligent AX1 Switchgear for Medium Voltage

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

How To Choose A Transformer

Modular Systems wind portfolio overview Power Collection and Grid Connection products

What will MV switchgear look like in the future? by Jean-Marc Biasse

ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact

Ralf Christian, CEO Low and Medium Voltage. Making Things Right with Totally Integrated Power (TIP)

ABB Power Systems. Substations References

High Voltage (HV) Electricity System Safety Rules and Associated Safety Guidance

Secondary Unit Substations

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Power products and systems. Intelligent solutions for power distribution Zone concept

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

DISCONNECTORS AND LOAD SWITCHES for railways

Relion. Power system protection and automation reference Fast substation busbar protection with IEC and GOOSE

CONTENTS.

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Permissible ambient temperature Operation Storage, transport

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

Gas turbine power plants

Part 1 System Modeling & Studies for Existing Systems

LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

Welcome IEEE Members and Guests Jan 20, 2014

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Low Voltage Switchgear

The following components are common to most cubicles; this example is an ABB HK cubicle.

CURRENT TRANSFORMERS INSTALLATION GUIDE

CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services

HYDRO-ELECTRIC POWER PLANTS

The following table shows approximate percentage wise the

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Phase Attribute Identification using GPS Technology

Service Power Technologies. Retrofitting A future-oriented concept in lifecycle management

Power Plant Electrical Distribution Systems

Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

Earth Fault Detection Basics in Theory

Electrical Shore Connections / Cold Ironing

MEDIUM VOLTAGE SWITCHGEAR. DI-2, a modular concept combining all mediumvoltage

Operational Control of the UKPN Low Voltage Distribution Network for EPN and LPN Regions

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Safe and secure distribution of medium voltage with AX1

CONSULTATION PAPER FOR PROPOSED MODIFICATIONS TO THE TRANSMISSION CODE

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Chapter 1. Network Structures

Fusible Disconnect Switch

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

QUALITY CONTROL Prepared: V. van Gastel / team TenneT Reviewed: M. Müller Approved: F. Wester BACKGROUND MATERIAL...

CAS 36 Ring Main Unit

Power transformers. Special transformers Railway

Protection and Substation Automation. Training Programmes

Disconnectors and Earthing Switches 36 kv up to 800 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv

Medium Voltage Distribution FLUVAC. Vacuum Circuit Breaker Up to 24 kv 630 A 21 ka. Operation Maintenance Instructions.

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

PSS SINCAL - Overview -

Relion. Power system protection and automation reference Extending substation life cycle with IEC 61850

ABB turnkey stations ULTRA-MVC-S 770 to 3110 kw

Intertek Cleeve Road, Leatherhead, Surrey KT22 7SB UK

64 Siemens Energy Sector Power Engineering Guide Edition 7.0

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

30 ms High Speed Transfer System (HSTS) Product Description

SPECIAL TOPICS ON GROUND FAULT PROTECTION AND PROTECTION COORDINATION IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium

Electrical Distribution Services for Mining and Metals Industries

CERTIFICATE ISO 9001:2008 ISO 14001:2004 BS OHSAS 18001:2007. hereby certifies that the company

Estimation of electrical losses in Network Rail Electrification Systems

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

Preliminary Results from Present Cigre Survey

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

Circuit Electrical Testing

Hyperlinks are Inactive

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / SC / SC / 1250SC / 1600SC / 1800SC / 2000SC

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

Compact and reliable. Decades of benefits: Gas-insulated switchgear from 52 to 1,100 kv Lothar Heinemann, Franz Besold

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Remote Monitoring and REC 501 Control Unit Product Guide

Current Transformers Ratio / Polarity / Types

Transcription:

Trapped Key Interlocks for HV Substations Switchgear Applications Guide - 1 -

London Chicago Cologne Shanghai Castell Offices Castell Installations We Keep You Safe at Work Worldwide -2-

Substations Switchgear Interlocking Applications Guide Contents Why Choose Castell... Interlocking Switchgear... How to Design an Interlock System... 4 5 6 Applications HV GIS Substation Interlocking (High Voltage Gas Insulated Switchgear Interlocking)... HV AIS Substation Interlocking (High Voltage Air Insulated Switchgear Interlocking)... Wind Farm Substation Interlocking... Switch Disconnector & Earth Switch Manufacturer s Interlock Specifications... Typical Interlocks Used in Substations... 7 8 9 10 11 While every effort has been made to ensure the accuracy of the information provided, no liability can be taken for any errors or omission. Castell Safety International Limited reserves the right to alter specifications and introduce improvements without prior notice. - 3 -

Why Choose Castell? Founder: James Harry Castell 1880-1953 Castell s Expertise in the Switchgear Industry The original Castell interlock concept dates from 1922 and was developed for the electrical switchgear industry. For over 90 years Castell delivers solutions across the electrical network from power stations to transmission and distribution equipment and from sub stations to incomer rooms. The ability to work across HV, MV and LV means that a Castell system can be used as a single solution to provide personnel safety and ensure equipment is used in the correct mode. Working closely with key switchgear manufacturers has enabled Castell to produce interlocks designed specifically for use on the leading manufacturers own breakers, isolators, switch disconnectors and earth switch mechanisms. That makes Castell trapped key interlocks be the perfect choice for protecting personnel in the switchgear environment. Castell Offers: Expertise in providing the best possible trapped key solution whatever the industry 90 years of experience protecting people and assets in industry High quality innovative products ISO 9001: 2008 accreditation Global team dedicated to providing technical support and assistance in selecting the correct solution The widest range of rugged and reliable trapped key interlock products globally The ability to produce customised solutions to meet the demands of your specific application Safety solutions that last for decades - 4 -

Interlocking Switchgear Interlocking Switchgear Interlocking switchgear ensures that personnel can safely operate equipment to the correct procedures. Using a well-designed interlocking scheme will ensure that personnel cannot access potentially dangerous areas without the switchgear system being put in a safe state. A good interlocking scheme will also ensure that the system operates correctly and there is no chance of, for example, switching two incoming feeds on to a common bus bar. This ensures that the equipment is not damaged and the risk of fire and arc flash are greatly reduced. Interlocking in switchgear provides safety for personnel and equipment during following procedures: Switching of high, medium and low voltage Switching incomers and feeders Switching earthing systems Maintaining substation equipment The schemes in this applications guide are for reference only and the overall system should be designed and reviewed by a competent electrical engineer. Common HV Substation Applications are: AIS Substation Interlocking GIS Substation Interlocking Wind Farm Substation Interlocking - 5 -

Trapped Key Interlocking How to design an interlock system? Through development and experience Castell has a number of methods to isolate switchgear. This can be done mechanically, through control circuitry or through power circuitry. In complex operations a number of isolations may need to occur to ensure the plant is safe to work on. The isolation key(s) are then used to either gain direct access, are transferred to a time delay unit or for multiple entry points access through an exchange box. The three points of trapped key interlocking 1 Isolation 2 Key Exchange 3 Access Control Access and Personal Protection Access to the hazardous area needs to be assessed as either part body (arm only), or full body access. Once this is determined an access lock(s) can be selected. Part Body Access A part body access lock has only one lock and the isolation key is used to open this. Whilst the access lock is open the key can not be removed and therefore the process can not be started. Only once the lock is closed can the isolation key be removed and the process restarted. Full Body Access Full body access locks have two locking mechanisms; the first step in the process is to insert the isolation key. This will allow the personnel key to be removed and then access can be granted by opening the bolt. The isolation key can only be removed once the personnel key has been inserted. Therefore whilst the personnel key is removed and the lock is open the process can not be started. Only once the lock is closed and the personnel key returned can the isolation key be removed and the process restarted. Coding a System The coding of the system is an important aspect of the design as this ensures the integrity and safety of the interlocking system. Castell s trapped key interlocks allow for in excess of 50,000 combinations. With this level of available codes entire factories and plants can have trapped key systems with out codes being repeated. It is highly recommended that each site keeps a record of the key codes to ensure that codes are not reused in areas of the site. The isolation, access and personnel keys all need to be coded differently so the process of safe access is ensured. For example in a simple system code A is used for isolation key, this is then transferred to the exchange box where the code B keys are released for access, C keys are then released from the Access Locks for personnel keys. Coding in this way ensures the access process can not be short cut and the system has integrity. - 6 -

HV GIS Substation Interlocking Diagram of GIS Interlocking (Example) Switchgear Interlocking Symbols 101 KEY RELEASED I OPE POSITIO. TRAPPED I ALL OTHER POSITIOS. WL1 LOCKOUT KEY: KEY RELEASED I OPE POSITIO. TRAPPED I ALL OTHER POSITIOS. KEY TRAPPED I FULLY OPE OR FULLY CLOSED POSITIOS. TRAPPED I ALL OTHER POSITIOS. M WL2 E KEY RELEASED WHE CB CLOSED I EARTH POSITIO. TRAPPED I ALL OTHER POSITIOS. ORMAL SERVICE POSITIO OF KEY. AIS 111 7T4 WL1 WL2 WARIG LABEL ISCRIBED: WARIG - THIS EARTH SWITCH IS OT FULLY ITERLOCKED AD MUST OT BE OPERATED ULESS THE CIRCUIT IS SWITCHED OUT AT THE REMOTE ED WARIG LABEL ISCRIBED: WARIG - THIS DISCOECTOR IS OT FULLY ITERLOCKED AD MUST OT BE OPERATED ULESS THE CIRCUIT IS SWITCHED OUT AT ALL POITS OF SUPPLY. KEY EXCHAGE BOX: KEY SHOW THUS, WHE ISERTED, WILL RELEASE KEYS SHOW THUS. GRID T1 132/33kV 60MVA ELECTRICAL BOLT ITERLOCK CIRCUIT. AUXILIARY SWITCHES O 33kV CB, CLOSED WHE CB IS OPE. GRID T1 EARTHIG / AUX TRASFORMER M MOTORISED DISCOECTOR TRASFORMER E KEY EXCHAGE BOX SWITCH DISCOECTOR WITH ITEGRAL EARTH SWITCH SWITCH DISCOECTOR GIS EARTH SWITCH CIRCUIT BREAKER GRID 1 7T4 33kV Operation For higher voltages, gas-insulated switchgear reduces the space required around live busbars. Instead of bare conductors, bus and apparatus are built into pressurized tubular containers filled with sulfur hexafluoride (SF6) gas. This gas has a higher insulating value than air, allowing the dimensions of the apparatus to be reduced. Solenoid controlled interlocks are normally used with GIS Switchgear as there are no mechanical parts to interlock, but only electrical signals, which are sent dependant upon the position of the switches. I.e. GRID 1 key 7T4 can only be released when key inserted and trapped sending signal to controls allowing switch to be opened and put into earth position. Signal is then sent to 7T4 releasing the key 7T4. Standard locks used for this application are solenoid controlled locks KSUPS or KSS (with Q-type lock portions). - 7 -

HV AIS Substation Interlocking Diagram of AIS Interlocking (Example) Switchgear Interlocking Symbols KEY RELEASED I OPE POSITIO. TRAPPED I ALL OTHER POSITIOS. 101 WL1 LOCKOUT KEY: KEY RELEASED I OPE POSITIO. TRAPPED I ALL OTHER POSITIOS. KEY TRAPPED I FULLY OPE OR FULLY CLOSED POSITIOS. TRAPPED I ALL OTHER POSITIOS. M WL2 E WL1 KEY RELEASED WHE CB CLOSED I EARTH POSITIO. TRAPPED I ALL OTHER POSITIOS. ORMAL SERVICE POSITIO OF KEY. WARIG LABEL ISCRIBED: WARIG - THIS EARTH SWITCH IS OT FULLY ITERLOCKED AD MUST OT BE OPERATED ULESS THE CIRCUIT IS SWITCHED OUT AT THE REMOTE ED AIS 111 7T4 WL2 WARIG LABEL ISCRIBED: WARIG - THIS DISCOECTOR IS OT FULLY ITERLOCKED AD MUST OT BE OPERATED ULESS THE CIRCUIT IS SWITCHED OUT AT ALL POITS OF SUPPLY. KEY EXCHAGE BOX: KEY SHOW THUS, WHE ISERTED, WILL RELEASE KEYS SHOW THUS. ELECTRICAL BOLT ITERLOCK CIRCUIT. AUXILIARY SWITCHES O 33kV CB, CLOSED WHE CB IS OPE. GRID T1 132/33kV 60MVA M MOTORISED DISCOECTOR GRID T1 EARTHIG / AUX TRASFORMER TRASFORMER SWITCH DISCOECTOR WITH ITEGRAL EARTH SWITCH E KEY EXCHAGE BOX SWITCH DISCOECTOR EARTH SWITCH CIRCUIT BREAKER GIS GRID 1 7T4 33kV Operation Switches, circuit breakers, transformers and other apparatus may be interconnected by air-insulated bare conductors strung on support structures. The air space required increases with system voltage. For mediumvoltage distribution substations, metal-enclosed switchgear may be used and no live conductors exposed at all. Mechanical interlocks are normally used to control the sequence of operation of the switch disconnectors and earth switches to ensure safe operation for both personnel and plant security. I.e. earth switch 111 shown above cannot be switched to earth until the switch disconnector and the GRID1 CB are switched and locked in open position releasing key 7T4. Keys and 7T4 can then be inserted into earth switch 111, which can now be closed. Standard locks used for this application are single, double or multiple deadlocks such as K and KL (with Q-type lock portions). - 8 -

Windfarm Substation Interlocking Diagram of Wind Farm Interlocking (Example) Switchgear Interlocking Symbols WTG (Wind Turbine Generator) KEY RELEASED I OPE POSITIO. TRAPPED I ALL OTHER POSITIOS. LOCKOUT KEY: KEY RELEASED I OPE POSITIO. TRAPPED I ALL OTHER POSITIOS. KEY TRAPPED I FULLY OPE OR FULLY CLOSED POSITIOS. TRAPPED I ALL OTHER POSITIOS. KEY RELEASED WHE CB CLOSED I EARTH POSITIO. TRAPPED I ALL OTHER POSITIOS. 101Y 33/0.69kV WL1 WL2 ORMAL SERVICE POSITIO OF KEY. WARIG LABEL ISCRIBED: WARIG - THIS EARTH SWITCH IS OT FULLY ITERLOCKED AD MUST OT BE OPERATED ULESS THE CIRCUIT IS SWITCHED OUT AT THE REMOTE ED WARIG LABEL ISCRIBED: WARIG - THIS DISCOECTOR IS OT FULLY ITERLOCKED AD MUST OT BE OPERATED ULESS THE CIRCUIT IS SWITCHED OUT AT ALL POITS OF SUPPLY. KEY EXCHAGE BOX: KEY SHOW THUS, WHE ISERTED, WILL RELEASE KEYS SHOW THUS. 101 101 101X 101Y ELECTRICAL BOLT ITERLOCK CIRCUIT. AUXILIARY SWITCHES O 33kV CB, CLOSED WHE CB IS OPE. M MOTORISED DISCOECTOR TRASFORMER 101X SWITCH DISCOECTOR WITH ITEGRAL EARTH SWITCH SWITCH DISCOECTOR EARTH SWITCH CIRCUIT BREAKER Operation A typical onshore wind turbine generator installation has a transformer fitted to step-up the output voltage from 690V to 33KV for connection onto the Grid. To maintain this transformer, which is usually housed in its own enclosure or room, it is necessary to isolate both the HV and LV connections to gain access to the transformer. I.e. access lock 101 on transformer enclosure can only be opened when both the LV isolator and the HV circuit breaker are switched to OFF, releasing keys 101X & 101Y. These keys are then inserted into key exchange box releasing the trapped key 101, which can now be used to open the access. The process is reversed to put the transformer back into service. Standard locks used for this application are single K deadlocks, AI or AIE access interlocks, X key exchange boxes. - 9 -

Substations Switchgear Interlocking Switch Disconnector & Earth Switch Manufacturer s Interlocks Specifications Disconnector & Earth Switch Manufacturer Alstom GRID (UK) Acrastyle (UK) Hapam (Holland) Gevea (Sweden) Ruhrtal (Germany) Castell Interlock K KL KP KLP K KL KP KLP K KL KP KLP K KL KP KLP K KL KP KLP Interlock Description Bolt Interlock (Single Key) Bolt Interlock (Double or Multiple Key) Bolt Interlock with Safety Switch (Single Key) Bolt Interlock with Safety Switch (Double Key) Bolt Interlock (Single Key) Bolt Interlock (Double or Multiple Key) Bolt Interlock with Safety Switch (Single Key) Bolt Interlock with Safety Switch (Double Key) Bolt Interlock (Single Key) Bolt Interlock (Double or Multiple Key) Bolt Interlock with Safety Switch (Single Key) Bolt Interlock with Safety Switch (Double Key) Bolt Interlock (Single Key) Bolt Interlock (Double or Multiple Key) Bolt Interlock with Safety Switch (Single Key) Bolt Interlock with Safety Switch (Double Key) Bolt Interlock (Single Key) Bolt Interlock (Double or Multiple Key) Bolt Interlock with Safety Switch (Single Key) Bolt Interlock with Safety Switch (Double Key) Lucy Switchgear (UK) Q Switchgear Interlock Siemens (UK / Germany) KSUPS Solenoid Controlled Switch ABB (UK / Germany) KSUPS KSS KSSE Solenoid Controlled Switch Solenoid Controlled Switch (Single Key) Solenoid Controlled Switch (Double or Multiple Key) **All locks are available in various specifications to suit individual applications. Please see our full product catalogue for more information or our data sheets on /downloads - 10 -

Typical Interlocks Used in Substations Solenoid Controlled Switching KSUPS + KSS KSSE Mechanical Isolation FS / Q K KL Key Exchange Boxes X Y Z W Part Body Access AI Full Body Access AIE **All locks are available in various specifications to suit individual applications. Please see our full product catalogue for more information or our data sheets on /downloads - 11 -

otes - 12 -

CSI-CAB/SWG2-2013-E Issue 1 Castell Safety International The Castell Building 217 Kingsbury Road London, W9 9PQ UK Castell Safety International Oskar-Jäger-Straße 137 50825 Köln Germany Castell Interlocks 150 Michigan Avenue Suite 800 Chicago IL 60601 USA Castell Safety International Building 1, o. 123 Lane 1165 Jindu Rd Shanghai, 201108 China t: +44 (0)20 8200 1200 f: +44 (0)20 8205 0055 t: +49 (0)221 169 47 94 f: +49 (0)221 169 47 95 t: +1 (312) 360 1516 f: +1 (312) 268 5174 t: +86 (0)21 6151 9028 f: +86 (0)21 6151 9030 uksales@castell.com vertrieb@castell.com ussales@castell.com chinasales@castell.com ISO 9001 Q 10297-13 - While every effort has been made to ensure the accuracy of the information provided, no liability can be taken for any errors or omission. Castell Safety International Limited reserves the right to alter specifications and introduce improvements without prior notice.