Technical Bulletin TB-A Air Pressure Switches

Similar documents
TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION



INTELLI-VENT CONTROL INFORMATION When Used On Gas, Residential, Power Vented Water Heaters

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

CARING FOR YOUR WATER HEATER

Thermo Top - Troubleshooting Tree

Service Handbook Commercial / Residential gas water heater

Fossil fuel heating equipment

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

Evaluate, Clean, and Tune Guidance

Tankless. Water Heater. Troubleshooting Manual

G670 Intermittent Pilot Ignition Controls

Rinnai Tankless. Water Heater. Troubleshooting Manual

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Commercial Gas Water Heaters

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Air Conditioning Sign-Off Sheet

BERMAD Fire Protection

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Oil and Coolant Circulating Heating System. Model - OCSM

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

HYDRONIC D5S/SC DIAGNOSTIC AND REPAIR MANUAL

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

OIL BURNERS LOW PRESSURE, DESIGNED FOR COMBUSTION OF LIGHT FUEL OIL, MEDIUM FUEL OIL-1P, WASTE OILS.

Commercial Gas Water Heaters

Service Handbook COMMERCIAL GAS HIGH EFFICIENCY WATER HEATERS

Class 5 to 7 Truck and Bus Hydraulic Brake System

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

Norcold Repair Guide Models 442, 443, 452, 453, 462, 463, 482, 483

Hydraulic Trouble Shooting

Boiler Preparation, Start-Up and Shutdown

Trouble Shooting. Pump

INTERNATIONAL FIRE TRAINING CENTRE FIREFIGHTER INITIAL PUMPS AND PRIMERS. Throughout this note he means he/she and his means his/hers.

SL280UHV SERIES GAS FURNACE WARNING

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work

Standardized Terminology for Combustion Appliances and. Combustion Safety Testing

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Your safety and the safety of others are very important.

SERVICE MANUAL. Flammable Vapor Ignition Resistant Water Heaters. Gas Water Heaters. Troubleshooting Guide and Instructions for Service

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Compressor Service & Maintenance Manual

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

BERMAD Fire Protection

Boiler and Burner Cleaning and Servicing Specifications

SERVICE PARTS INSTRUCTIONS

SERVICE TIPS. Dometic REFRIGERATORS. Models. OS1927 4/96 Copyright 1996 The Dometic Corporation

Error Codes: 02F. Model: (110. = Whirlpool) S/N: CSP Type: 199-AKP 705/WT. Sears Kenmore/Whirlpool Front Load Washer

Annual Service Agreement

Failure code manual. content

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

2010 Residential Water Heater Replacement Check List

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

E-PDD Duct Smoke Detector Installation Sheet

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

Commercial Gas Water Heaters

Luna 3 Comfort Troubleshooting Guide June 2008

Gas Oven Repair Guide

DRYER VENTING SPECIFICATIONS DRYER SAFETY

Hydraulic Troubleshooting PRESENTED BY

37E73A-903 & 906 INTELLI-VENT

1 DESCRIPTION OF THE APPLIANCE

Residential Gas and Electric Water Heaters

MP-4000 Alarm List (Software version or later)

Operator: Save these instructions for future use!

Oregon Fuel Injection

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

COOLING SYSTEM Section Page

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Service Manual Models:

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Boiler & Pressure Vessel Inspection discrepancies and failures

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

BOSCH D-JETRONIC Volkswagen: Type 3 & 4

Orlando Home Inspection Services

Flame Conductivity VS Flame Rectification Systems

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Condensing Tankless Water Heater Service Manual

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Transcription:

es Tuesday, January 16, 2007 This bulletin has been prepared to explain and illustrate the construction, operation, and testing procedures for various types of air pressure switches used on residential and commercial tank type water heaters. Air pressure switches are used on all fan assisted gas fired water heaters in our product line. Air pressure switches are used to verify that operational conditions are being met; IE: the blower is running or the vent/combustion air piping length is not excessive or obstructed. Air pressure switches are usually wired together with other switches into a series circuit (see page 8). The ignition control constantly monitors the state of the air pressure switch circuit - whether it is open or closed. There will always be at least one air pressure switch that has normally open contacts (see pages 7 & 8). As the blower starts and comes up to speed the normally open contacts of this switch should activate (contacts will close) in response to the pressure it senses as long as there are no adverse operating conditions. Normal Operating Sequence - Pressure Switch Circuit (Power-Vent, Power Direct-Vent, Cyclone, Master-Fit BTN/BTI models) 1. At the beginning of a heating cycle the ignition control will verify the air pressure switch circuit is open before the control energizes the blower motor. 2. After successfully completing the above open circuit verification step, the ignition control will energize the blower, the control will then check the air pressure switch circuit a second time after the blower is energized. This time the pressure switch circuit must be verified closed. The ignitor would not be energized unless this circuit closes after the blower is energized. 3. The ignition control monitors this circuit during the entire heating cycle to ensure it remains closed. If this circuit opens (even for a split second) during the heating cycle; the control will close the gas valve and stop the heating cycle. By monitoring the air pressure switch circuit an ignition control can perform critical operational checks such as: 1. Verify normally open air pressure switch contacts are not stuck closed or jumpered. 2. Verify the combustion blower or inducer fan is running. 3. Verify the vent/combustion air piping length is not excessive and/or obstructed. Paul Stewart Technical Training Department A. O. Smith Water Products Company Ashland City, Tennessee Technical Bulletin TB-A023-06 AHSA02307 1 of 8

Construction Normal State (open switch contacts) Sensing Port Wiring Terminals Activated State (closed switch contacts) Switch Contacts Internal Linkage Flexible Diaphragm Vent Port Operation Air pressure switches activate in response to pressure sensed through a tube. One end of this tube attaches to the pressure switch sensing port, the other end attaches to a pressure sensing port somewhere on the water heater, IE: the vent system, blower assembly. A flexible diaphragm divides the body of the switch into two air chambers. The sensing port is attached to one air chamber. The other air chamber is vented to the atmosphere which allows the diaphragm to move. Internal linkage attaches the switch contacts to the diaphragm; with sufficient pressure applied, diaphragm movement will activate the switch contacts. Contact States: The state of the contacts refers to whether or not the switch contacts are open or closed. Closed contacts will allow electricity to flow through the switch because there is a continuous conductive path through the switch contacts. Open contacts will not allow electricity to flow, there is no continuity through the switch contacts. The state of the contacts, open or closed, can be verified/confirmed with an ohm meter. An ohm meter is required to perform conclusive diagnostic tests on air pressure switches. With air pressure switches the term normal state refers to whether or not the switch contacts are open or closed when there is no pressure applied to the switch. Switches can be normally open or normally closed, abbreviated NO or NC in technical literature. The activated state of a switch is the opposite of the normal state. A normally open switch in it s activated state is closed. A normally closed switch in it s activated state is open. Air pressure switches are described by their normal state and by their contact action which is covered on the following page. AHSA02307 2 of 8

Operation (cont) Contact Actions: The action of the contacts refers to what causes the switch to activate, to change from it s normal state to its activated state (see page 2). On an air pressure switch this can be either a rise or fall in pressure. As the illustrations below indicate, locating the sensing port above or below the flexible diaphragm facilitates these operational differences. The contact action is further described to convey whether the contacts will open or close when the pressure sensed is sufficient to activate the switch contacts, IE: close on a fall in pressure. Pressure Switch Descriptions: Air pressure switches are described and referred to by their Contact State and Contact Action. IE: the switch on the left side in the illustration below is a normally open, close on a fall pressure switch. See page 7 for more information about other types of switches. Normally Open, Close on a Fall Normally Open, Close on a Rise Sensing Port Above Diaphragm (a fall in pressure or vacuum activates the switch) Vent Port Flexible Diaphragm Sensing Port Beneath Diaphragm (a rise in pressure activates the switch) Service Note: Because one of the two air chambers is vented to the atmosphere, the ambient (in the surrounding area) air pressure is critical. Ambient air pressure can push or pull on the diaphragm through the vent port. If the ambient air pressure is extremely high (positive) or low (negative) it may cause erratic pressure switch operation. Direct vent installations will not eliminate this potential problem. Tools Required for Testing A volt/ohm multi-meter - Fieldpiece HS36 DMM (digital multi-meter) or equivalent. A digital manometer is also required to measure pressure and perform conclusive diagnostic tests. Specifications: range; -15.0" W.C. to +15.0" W.C. resolution; 0.01" W.C. Brands/models recommended that meet these specifications include: UEI model EM-200 and Extech model 406850 dual pressure reading digital manometers. AHSA02307 3 of 8

Testing Continuity Test With Ohm Meter Power-Vent Residential Model Continuity Test With Ohm Meter BTH 120-250 Blocked Exhaust Switch Testing the performance of air pressure switches involves three procedures. First Procedure is a normal state test to determine if the switch contacts are open or closed in the normal state (see page 2) without pressure applied. Power is turned off for this test. The wires to the switch are disconnected. A continuity test is then performed (ohm meter) between the wiring terminals on the switch. If the switch is a normally open switch (see page 2) the continuity test should indicate no continuity - open. If the result of this test indicated the contacts were closed, the switch must be replaced. Likewise if a normally closed switch s contacts tested open in its normal state it would also have to be replaced. Note: gaining access to the switch and it s wiring terminals may involve removing the switch, opening a control box etc. THE SECOND AND THIRD PROCEDURES ARE PERFORMED WITH THE BLOWER RUNNING. Second Procedure is an operational test to determine if the switch contacts are open or closed while the blower is running and pressure is applied to the switch. The wires to the switch remain disconnected and a continuity test is performed as in the first procedure above. Ensure the wires ends do not touch/short to ground. Ensure the sensing tube is properly connected at both ends and test for continuity with the blower running at full speed. Note the condition of the switch contacts; whether open or closed. Normally open air pressure switches must close during operation and normally closed air pressure switches must remain closed throughout the heating cycle on A. O. Smith fan assisted water heaters. This information can usually be found in the sequence of operation section of the owner s manual and/or service manual for the product. Contact the A. O. Smith technical information center (800 527-1953) for more information. Normally open switches: If the air pressure switch being tested is a normally open switch, it must close it s contacts (activate) before ignition can occur. If the continuity test indicates a normally open switch s contacts have closed while the blower is running, the switch is operating correctly. If the continuity test indicates the switch contacts are remaining open while the blower is running the third pressure test procedure will have to be performed. This will determine if the switch is defective or if the switch contacts are failing to close because the pressure being sensed has not reached the activation point for the switch. This is covered on the next page. Normally closed switches: If the air pressure switch being tested is a normally closed switch, the switch contacts must remain closed throughout the heating cycle. If the continuity test indicates a normally closed switch s contacts remain closed while the blower is running, the switch is operating correctly. If the continuity test indicates the switch contacts are opening after the blower starts the third pressure test procedure will have to be performed. This will determine if the switch is defective or if the switch contacts are opening because the pressure being sensed has reached or exceeded the activation point. This will be covered on the next page. AHSA02307 4 of 8

Testing (cont) The pressure activation point for the air pressure switch below is - 1.07" W. C. (inches water column) This is a negative pressure value in a vacuum. Blocked Vent Switch - Pressure Test Vertex Residential Power Vent Model Blocked Vent Residential Power Vent Model Third Procedure is a pressure test and requires a digital manometer capable of reading positive and negative pressures. A good range of operation would be +15.00 W.C. to -15.00 W.C. (inches water column) with a resolution of 0.01 W.C. Recommend the UEI model EM-200 or Extech model 406850 dual pressure digital manometers, not shown here. To determine if an air pressure switch is operating properly you must know the pressure activation point for the switch and whether it activates on a rise or a fall in pressure. The activation point is a given pressure value and may be a positive or negative (in a vacuum) pressure. This information is often provided on the switch label (see image above). Whether the switch activates on a rise or fall in pressure is the type of switch action, this information is available here (page 7) for most current residential and commercial fan assisted water heaters. Contact the technical information center 800 527-1953 when the activation point and/or switch action are not known. Have the complete water heater Model, Serial, and Series number on hand before calling. Taking Air Pressure Readings: Disconnect the pressure sensing tube from the sensing port on the switch, leave the other end connected. Examine the sensing tube connection on the water heater, check for wear, leaks, kinks, or any kind of debris or condensate in the sensing tube, repair/replace as necessary. Connect a digital manometer to the pressure switch end of the sensing tube as shown above. Turn the power on and ensure a call for heat is active. When the blower starts and comes up to full speed, record the pressure reading. Normally Open Switches: Normally open air pressure switches must close their contacts after the blower is energized, the pressure reading taken must reach or exceed the activation point (pressure value) for the pressure switch being tested or the contacts will not close. Pressure reading taken DOES NOT reach activation pressure: DO NOT replace the air pressure switch if the contacts do not close during second procedure. The switch is not defective. IE: Residential power vent product - the pressure switch on these products is a normally open - closes on a fall in pressure switch (see page 7). If the activation point for the switch is - 1.07 W.C. and the actual pressure reading taken was - 0.85" W.C., the actual pressure has not reached the activation point. The switch contacts will not close until the pressure reaches or exceeds - 1.07" W. C.. AHSA02307 5 of 8

Blocked Exhaust Switch Pressure Test Cyclone - BTH 300/400 Models Testing Third Procedure - Normally Open Switches (cont): Pressure reading taken DOES NOT reach the activation pressure (cont): Ensure the sensing tube is connected securely and not blocked with any debris or condensate. Ensure the tube is not kinked or leaking. On residential power vent models check vent piping for excessive length or number of elbows, check for obstructions in the vent pipe. On Cyclone BTH models ensure the minimum vent pipe length requirement (7' BTH 120-250, 15' BTH 300/400) has been met. Ensure the blower wheel is clean on all models. This can become dirty over time or during construction on new water heaters and cause operational problems. Pressure reading taken DOES reach the activation pressure: If the test results for the second procedure indicated the normally open switch contacts did not close and the pressure reading taken during the third procedure indicated the pressure sensed by the switch did reach or exceed the activation point (pressure value) for the switch, the switch is defective and should be replaced. Normally Closed Switches: Current design residential power-vent/power direct-vent and commercial BTI/ BTN models are not equipped with normally closed air pressure switches. Cyclone BTH 120 400 models are equipped with two normally closed air pressure switches; a blocked inlet and blocked exhaust switch (see pages 7 & 8). Normally closed switches should remain closed at all times unless there is an operational problem. Pressure reading taken DOES NOT reach the activation pressure: If the test results for the second procedure indicated a normally closed switches contacts were opening during blower operation AND the pressure reading taken DOES NOT reach or exceed the activation point (pressure value) for the switch, the switch is defective and should be replaced. Pressure reading taken DOES reach the activation pressure: Blocked Exhaust Switch Pressure Test Cyclone - BTH 120-250 Models If the test results for the second procedure indicated a normally closed switch contacts were opening during blower operation AND the pressure reading taken DOES reach or exceeds the activation point for the switch DO NOT replace the switch, it is not defective. Ensure the intake air or vent piping is not excessive and both are free of obstructions. Always check the owner s manual vent installation section for proper intake air and vent pipe installation requirements. AHSA02307 6 of 8

Types Contact States Normally Open = NO Normally Closed = NC Contact Actions Close on a rise in pressure Close on a fall in pressure Open on a rise in pressure Open on a fall in pressure Application Normal State Activated State Blocked Exhaust Power-Vent & Power Direct Vent Residential Models Blower Prover BTI/BTN 120 400 Models Normally open contacts, close on a fall in pressure. Blocked Intake Cyclone BTH 120-400 Models Normally closed contacts, open on a fall in pressure. Blower Prover Cyclone BTH 120-400 Models Normally open contacts, close on a rise in pressure. Blocked Exhaust Cyclone BTH 120-400 Models Normally closed contacts, open on a rise in pressure. AHSA02307 7 of 8

Circuit Residential Power-Vent & Power-Direct-Vent Water Heaters 1 Blocked Exhaust Switch Normally Open Contacts Close on a Fall in Pressure Vent Temperature Limit Switch Normally Closed Contacts Open on a Rise in Temperature Molex Plug 6 Pin Plug 4 Circuit Cyclone Water Heater 4 Blocked Inlet Switch Normally Closed Contacts Open on a Fall in Pressure Blocked Exhaust Switch Normally Closed Contacts Open on a Rise in Pressure CN6 Plug Control Board 6 Blower Prover Switch Normally Open Contacts Close on a Rise in Pressure AHSA02307 8 of 8 Low Gas Pressure Switch Normally Open Contacts Close on a Rise in Pressure (BTH 120, 250, 300, 400 only)