Avon range of Booster Pump Sets

Similar documents
Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

ECOCIAT. Domestic hot water heat recovery unit

Link-Up. Solid Fuel Association Guide to Central Heating.

marine/bespoke split applications

FLASH TANK ECONOMIZER PRODUCT GUIDE

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Operation & Maintenance Manual

Solar Hot Water Heaters

BOILER FEED AND CONDENSATE RECOVERY SYSTEMS Extend the life and efficiency of your boiler system

HVAC Processes. Lecture 7

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

Oil and Coolant Circulating Heating System. Model - OCSM

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

EXPANSION AUTOMATS. Flamco. Compressor and pump expansion automats, pressurisation units FLEXCON M-K FLAMCOMAT ENA.

Electric Flow Boiler

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

MUELLER FALLING FILM CHILLERS

SF15K SF05KSS, SF10KSS

WWZ High efficiency HYBRID heat pumps with E.V.I compressor in two sections

MAC-120HE-01 Air-Cooled Chiller

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Designed for multi-injector endurance testing, the

Heating and Hot Water Services Controls General Technical Specification

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Element D Services Heating, Ventilating, and Air Conditioning

STORAGE CALORIFIERS & BUFFER VESSELS

PRESSURISATION UNITS EXPANSION VESSELS ELECTRONIC FILLING DEVICE (EFD) MAXI MAXI PLUS EXPANSION VESSELS

ice 3 FLUID TO FLUID HEAT PUMP

Annex-A TECHNICAL SPECIFICATION

Cool Design for Homes and Offices

Condensing unit type EPSILON-ECHOS LE Technical information manual

Technical data. Danfoss DHP-A

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

Morrison Bros. Co. General Product Specifications

Factory owners must ensure the boiler is:

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

A. Section includes air conditioning units, controls and control panels.

Refrigerated. Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Medical Air Systems: Scroll

building engineering services association specification for: Domestic Heating

Electro-Pneumatic Bus Door Control Mechanism

How To Clean Up A Reactor Water Cleanup

Electric Instantaneous. Water Heaters. Service manual

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

Power Generation. Power Control PCL System Generator Set Control

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:

Questionnaire Pure Media Systems

Marine Generating Sets 3.7 to 50 kva

FAIRBANKS NIJHUIS FIRE PUMPS.

BoilerMate SP. benchmark. user instructions A - C L A S S

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

ENERGY RETROFIT PROGRAM

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

Utility Distribution Systems

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Session 2: Hot Water Supply

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

NFPA31FuelOilPiping 1 Revised

PRODUCT RELEASE CKMTA12 / 24. Copyright 2011 by ARB Corporation Limited

The Yachtmans Choice...

Nexus FS Point of Use Installation Guide

DESIGN STANDARDS SECTION

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Nirvana. Cycling Refrigerated Dryers

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

Horizontal Split Case Fire Pumpset Diesel Engine Driven

Automatic control equipment for HVAC systems

Sizing and Selection of Hot Water Generating Plant. Presentation by: Rob Larner & David Dutch

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Electronic Manual Gearbox

ATS - Automatic Changeover

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

WATER pressure. Issue 3 / Clear water pumps for domestic and commercial applications

INSTALLATION, OPERATION, MAINTENANCE AND PARTS MANUAL 'J' SERIES - GAS FIRED STEAM BOILERS (6J - 60J)

Commercial Semi-Instantaneous Water Heaters

Building Services Engineering Technician

UNDERSTANDING CENTRAL HEATING SYSTEMS

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold

Transcription:

Pressurisation

Avon range of Booster Pump Sets RYCROFT PRESSURISATION OFFERS A COMPLETE RANGE OF BOOSTER SETS COMPRISING OF SINGLE AND MULTI PUMP UNITS. THE AVON RANGE COVERS FLOW RATES OF UP TO 41.5M 3 /h AND PRESSURES UP TO 80M. PUMP MANIFOLDS ARE AVAILABLE IN COPPER, STAINLESS STEEL, GALVANISED OR UPVC MATERIALS. The standard AVON package incorporates the following items: Single pump Control Panel (IP54) to IEE Regulations 1 x Pressure switch 2 x Isolating ball valves 1 x Non return valve 1 x Pressure gauge 1 x Accumulator Purpose built folded steel base Automatic or Manual operation The standard AVON TWIN pump packages incorporate the following components: Twin pump Control Panel (IP54) to IEE Regulations complete with the Indicators for Power On, Pump tripped, Low water Microprocessor, Pump starters and overloads, Low water reset button. Hand/Off/Auto selector switch for each pump 1 x Pressure transducer and indicator gauge 4 x Isolating ball valves 2 x Non return valves 1 x Pressure gauge 1 x Accumulator Purpose built folded steel base. The standard AVON TRIPLE pump packages incorporate the following components: Three pump Control Panel (IP54) to IEE Regulations complete with the Indicators for Power On, Pump tripped, Low suction Microprocessor, Pump starters and overloads, Low suction reset button. Hand/Off/Auto selector switch for each pump 1 x Pressure transducer 6 x Isolating ball valves 3 x Non return valves 1 x Pressure gauge 1 x Accumulator Purpose built folded steel base Optional extras for AVON booster sets: Anti-vibration mountings, flexible couplings, specific customer requirements, pressure reducing valve. 2

Severn range of Booster Pump Sets For larger duties the SEVERN range of booster sets can be used. The Severn range of booster sets are offered in single and multipump configurations incorporating the following components. Control Panel (IP54) to IEE Regulations complete with the Indicators for Power On, Pump tripped, Low water Microprocessor, Pump starters and overloads, Low water reset button. Manual override. Frequency convertor (variable pump motor speed) Pump isolating ball valves Pump non-return valves Pressure indicator Purpose-built folded steel base Anti-vibration mountings Automatic pump change over on fault conditions Remote ON/OFF The diversity of the control features enable the Severn range of booster pumps to meet requirements for constant or differential pressure control systems. Traditional fixed speed motors are also available. Head FT m 800 200 600 500 400 300 100 250 200 150 50 40 100 30 50 40 30 20 10 5 4 20 10 5 4 3 2 1 1 Avon Single Pump Avon Twin Pump Avon Triple Pump Severn Single Pump Severn Multi-Pump 2 3 4 5 10 20 30 40 50 100 150 600 m 3 h 2

Pennine, Derwent Spill and Nitro-unit Pressurisation sets THE EXTENSIVE RYCROFT RANGE OF PRESSURISATION EQUIPMENT COVERS APPLICATIONS FOR BOTH CHILLED AND HOT WATER S. The PENNINE unit is an economic packaged pressurisation set capable of controlling system pressure and water make up requirements. Working pressures of up to 6 Bar g and temperatures of 90 C can be accommodated. (115 C with the use of a thermal buffer vessel). Single and twin pump arrangements are available. The standard PENNINE unit incorporates the following components: Pressurisation pump Pressure indicator Purpose-built folded steel base Pressure regulator 20 litre make-up tank with a type A air gap Pump isolating valve Pressure adjustment switch Accumulator vessel When required an IP 54 rated control panel can be supplied complete with Indicators for Power On, Pump tripped Hand/Off/Auto selector switch Door interlocked isolator Volt-free common alarm DERWENT SPILL units provide control of pressurised systems in excess of the normal Pennine packages. This unit can accommodate rapid changes in contraction and expansion. During periods of excessive expansion the system water can be accommodated into a spill tank. DERWENT SPILL systems incorporate the following components: Pressure vessel Pressurisation pumps Pressure switches Pressure gauges Pump isolating valves Spill tank Control panel complete with: Volt free common alarm Indicators for Power On, Low pressure, High pressure Hand/Off/Auto selector switch Door interlocked isolator Optional extras: Low level make up flow switch Audible alarm Specific specification requirements Dual pump Optional extras: System expansion vessel Audible alarm Low level make-up float switch Pressure regulating valve Derwent Spill Unit Pennine Unit SCOPE OF SUPPLY OVERFLOW COLD FEED EXPANSION VESSEL SPILL TANK A-TYPE AIR GAP SIGHT GLASS SPILL SPILL TANK LOW WATER CONNECTION SAFETY LOCKABLE GATE PUMP 1 ON PUMP 2 ON LOW PRESSURE SPILL ACTIVATE HIGH PRESSURE P CONTROL PANEL WITH PRESSURE CONTROLLER PRESSURE TRANSDUCER 3

Nitro-Unit THE NITRO-UNIT PROVIDES AN EFFICIENT AND SAFE MEANS OF PRESSURE CONTROL. THE OPERATION OF THE PACKAGE IS TO CREATE A PRESSURISED CUSHION OF NITROGEN BEHIND THE EXPANDING WATER OF THE UNTIL MAXIMUM PRESSURE IS ACHIEVED. THEREAFTER THE CONDITIONS ARE AUTOMATICALLY CONTROLLED TO COPE WITH THE NORMAL FLUCTUATIONS OF TEMPERATURE RISE AND FALL TOGETHER WITH REPLENISHMENT OF WATER, AS REQUIRED, FOR THE NORMAL LOSSES IN THE. NITRO-UNITS ARE DESIGNED TO MEET SPECIFIC PROJECT REQUIREMENTS. The NITRO-UNIT is supplied as a complete package incorporating the following components: Pressure vessel to BS 5500 Duplicate pressurisation pumps (cascade operation) Pressure switches Nitrogen supply solenoid valve (Nitrogen supplied by customer). Safety valve Spill valve Spill tank Level gauge Control Panel (IP 55) to IEE Regulations incorporating the Indicators for Power On, Pump tripped, High pressure, Low pressure, Low water Hand/Off/Auto selector switch for each pump. SCOPE OF SUPPLY OVERFLOW COLD FEED NITROGEN INLET PRESSURE VESSEL MAGNETIC LEVEL SWITCH SPILL TANK A-TYPE AIR GAP SIGHT GLASS LOW N2 LOW WATER EXTRA LOW WATER SPILL SPILL TANK LOW WATER CONNECTION SAFETY LOCKABLE GATE PUMP 1 ON PUMP 2 ON LOW PRESSURE SPILL ACTIVATE HIGH PRESSURE PRESSURE TRANSDUCER CONTROL PANEL WITH PRESSURE CONTROLLER P Unit System Volume L Temperature Range C Pennine 42 500 90 Std. 115 c/w Buffer vessel Derwent Spill 450 000 115 Nitro-Unit 450 000 160 For specifications falling outside of the standard range please contact our sales department. Commissioning and Servicing Contracts Rycroft offer both commissioning and servicing contracts on all pressurisation products. Please contact our Customer Service Department for more information. 4

SUPAPAC Plate Heat Exchangers Shell and Tube Heat Exchangers COMPAC Plate Heat Exchanger Packages MAXIMISER Semi-Storage Calorifiers Calorifiers/Cylinders Unvented Packages Pressurisation Electric Water Heaters Rycroft Process Solutions BS EN ISO 9001 FM No 28819 Rycroft Ltd, Duncombe Road, Bradford, England BD8 9TB. Telephone: +44 (0) 1274 490911. Facsimile: +44 (0) 1274 498580 Rycroft reserve the right to alter the specifications without prior notice.