FLOW METER INSTALLATION FLOW METER INSTALLATION. water work. making

Similar documents
Step-by-step instructions:

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

Installation Instructions S

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Submersion/Insertion Toroidal Sensor

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

1.8 CRANKSHAFT OIL SEALS

INSTALLATION INSTRUCTIONS

MP8000 Series Pneumatic Valve Actuators

SureSite Magnetic Liquid Level Indicator

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

Installation Instructions

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

INSTALLATION & OPERATING INSTRUCTIONS

with installation dynafact boost GAUGE this manual is for use with systems

Series Hose Reels

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

Micrio WS1 Replacement Wind Speed Sensor and WC1 Replacement Wind Compass Sensor for Raymarine ST50 and ST60 Wind Instruments. Rev 4.

Easy Tool Retracting System CMC-SR2159ER36

INSTRUCTIONS TLE/TLE-ULTRA SIDECAR ATTACHMENT KIT 1WARNING -J00803 REV General PRE-INSTALLATION MODIFICATIONS. Longer Clutch Cable

Auto-belay Cable Replacement Process

Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems

OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Submersion/Insertion Toroidal Sensor

758 Heavy-duty Ratchet Guy Wire Cutter

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

ARVINMERITOR UNITIZED FRONT WHEEL HUB INSPECTION AND MAINTENANCE

CALIBRATION FOR LAL20X & LAL24X

AMERBRITE UNDERWATER WHITE LED POOL LAMP

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

The Ford Model A Water Pump

Tech Bulletin. Hose / Cord Replacement and Required Wraps. Series RT

DYNA RIDER FOOTBOARD KIT

Your safety and the safety of others are very important.

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

STEERING SYSTEM - POWER


INSTALLATION MANUAL. Installation Instructions

IMPACT SPRINKLER TROUBLESHOOTING GUIDE

Wind Direction Smart Sensor (S-WDA-M003)

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

Guidelines for Earthquake Bracing of Residential Water Heaters

Service Manual Rol-Lift

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Tri-Homo Style Operation and Maintenance Instructions

Triac Printed Circuit Board Replacement

Toroidal Conductivity Sensor

12-Volt Negative Ground Installation Instructions

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

Operating Instructions

Front axle components, overview

P7100 PUMP INSTALLATION INSTRUCTIONS Diesel Care & Performance Inc

STEERING HANDLEBAR/FRONT WHEEL/ FRONT SHOCK ABSORBER

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Rebuild Instructions for and Transmission

Parts#MB Reverse Gear MAMBA (Monoblock for Cable operated) For 5 speed Trans., '87 to '06 Big Twin models (except '06 Dyna)

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Watts Pure Water Systems

XL PREMIUM OIL COOLER KIT

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

SCION tc COIL OVER SUSPENSION Preparation

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Installation Guide for Artic Air 24 Volt R134A Air Conditioner

# MOTOR MOUNT HOBIE 16.

2006 HEADSHOK Service Video #1

16 April F Dodge Adjustable Track bar with Relocation Bracket 1

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List

WARNING! DO NOT ATTEMPT TO INSTALL THIS KIT IN A POWERED CONVEYOR.

Guidelines for Earthquake Bracing Residential Water Heaters

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

GPS AutoSteer System Installation Manual

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

Slide the new steering column shaft through the steering column from the driver compartment.

A99B Series Temperature Sensors

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Air Sleeve Maintenance

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

VOYAGER 570G. 744A Sprayer Control

Installation Instructions for Water Methanol Stage 1

jbs nfb INSTALLATION INSTRUCTIONS AND OWNERS MANUAL Mechanical Steering for Inboard, Outboard, and Sterndrive Powered Vessels

INSTRUCTION MANUAL AND PARTS LIST MODEL 14-10

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

Rear wheel brakes, servicing. Стр. 1 из 45. Note:

Tipping Bucket Rain Gauge Models 6011-A 6011-B

IntelliChlor Flow-Temperature Switch Replacement Kit Installation Guide

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

BOWIE PUMPS OPERATION - MAINTENANCE

Transcription:

FLOW METER INSTALLATION FLOW METER INSTALLATION

FLOW METER INSTALLATION FLOW METER GENERAL The accuracy of flow measurement for all flow measuring devices is highly dependent on proper location of the sensor in the piping system. Irregular flow velocity profiles caused by valves, fittings, pipe bends, etc. can lead to inaccurate overall flow rate indications even though local flow velocity measurement may be accurate. A sensor located in the pipe where it can be affected by air bubbles, floating debris, or sediment may not achieve full accuracy and could be damaged. Calsense flow sensors are designed to operate reliably under adverse conditions, but the following recommendations should be followed to ensure maximum system accuracy: Choose a location along the pipe where 10 pipe diameters upstream and 5 pipe diameters downstream of the sensor provide no flow disturbance. Pipe bends, valves, other fittings, pipe enlargements and reductions should not be present in this length of pipe. The preferred location around the circumference of a horizontal pipe is on top. If trapped air or debris will interfere, then the sensor should be located further around the pipe from the top but not more than 45 degrees from top dead center. The sensor should never be located at the bottom of the pipe, as sediment may collect there. Locations off top dead center cause the impeller friction to increase, which may affect performance at low flow rates. Any circumferential location is correct for installation in vertical pipes. PHYSICAL INSTALLATION The Flow meter is installed after the water meter or backflow device. The Master Valve can be installed on either side of the Flow Meter. The mainline pipe is usually sized down during the installation to accommodate the fitting of the Flow Meter. Note the intended direction of the flow as indicated by an arrow on top of the Flow Meter. There must be free, unrestricted pipe of the same size as the Flow Meter, with a length of at least 10 times the flow meter size upstream, and 5 times the flow meter size downstream of the Flow Meter tee. This should apply to distance from any valve, fitting, meter, or backflow device. The Flow Meter shall be easily accessible, housed in a rectangular valve box, and marked FM. There should be 8 of pea gravel beneath the Flow Meter in the valve box. Maximum Wire length should not exceed 2000 feet.. Alignment of the sensor to ensure that impeller rotation is parallel to flow is important.

FLOW METER INSTALLATION TO ENSURE PROPER INSTALLATION Remove the clevis pin and remove the Flow Insert from the tee by pulling gently up on the lip of the Flow Meter. Properly clean the pipe ends and tee sockets. Solvent cement the pipe to the tee. Reinstall the Flow Insert in the tee as follows: Align the arrow on top of the insert in the direction of the flow. Carefully press the Meter straight into the tee. CAUTION: The impeller may strike sides of the tee if missaligned, causing damage to the impeller or shaft. Install the clevis pin through the tee and meter. Insert the locking ring. ELECTRICAL INSTALLATION Wires from the Flow Meter to the irrigation controller should consist of one (1) BLACK and one (1) RED standard #14 AWG irrigation wire. The Flow Meter has two wire leads, one (1) BLACK, and one (1) RED. At the controller, the BLACK wire in the BLACK harness is connected to the BLACK Flow Meter wire, and the RED wire in the BLACK wire harness is connected to the RED Flow Meter wire. The Calsense Flow Meter operates at 9.0 volts DC. The flow meter wires should be separated from other control wires when pulled up at the irrigation controller site. CAUTION: If 24 volts AC is used to test field wires when determining proper sequencing, and is applied to the Flow Meter wires, the sensing unit in the Flow Meter could be damaged. It is very important that all electrical connections are tight and dry. Any water leaking into a connection will cause flow meter problems. Additionally, there should never be any buried splices between the flow meter and the irrigation controller. Use only Calsense recommended electrical connections.

FLOW METER INSTALLATION FMBX INSTALLATION The Calsense Model FMBX Flow Meter is deigned to be used for mainline pipe ranging from 2 ½ to 40. It is mounted to the pipe using a pipe saddle or Welded-on threaded fitting (which are not included with the FMBX Flow Meter). It is constructed of brass and bronze hardware, and is provided with a bronze 2 NPT externally threaded hex adapter for mounting (Figure 1). The accuracy of flow measurement is highly dependent on proper location of the sensor. IT should be positioned on top of a horizontal pipe, and located along the pipe where 10 times the pipe diameter upstream and 5 tines the pipe diameter downstream of the flow meter provide no flow disturbances. There should be no pipe bends, fittings, or valves within these minimum distances. Install the 2 NPT adapter provided, using the thread sealant to prevent leakage. Tighten as necessary. Data Industrial insert style sensors are calibrated with the sensor inserted 1 1/2 into the pipe flow. To determine the proper insertion depth, proceed as follows: o Apply Anti-seize thread lubricant, supplied with the sensor, to the threaded studs of the mounting adaptor. The insertion depth and alignment of the sensor assembly are critical to the accuracy of the flow measurement. The flat end of the sensor tube assembly must be installed 1 1/2 from the inside wall of the pipe. o Insert the depth gauge into the mounting adapter and set it against the inside wall of the pipe (as shown in Figure 2). Figure 1

FLOW METER INSTALLATION Figure 2 o o Set the top of the upper adjusting nut on the same stud. Repeat for the other 3 adjacent nuts. Note: For 220PVS: set nuts 6.5 above inside wall of pipe. Clean O-Ring and Flow Sensor sleeve. Lubricate O-Ring with silicone grease from the packet provided or some other acceptable lubricant. Insert the Flow Sensor into the 2 NPT adapter so that the mounting holes in the positioning collar fit over the studs on the adapter. Lower the sensor onto the previously adjusted nuts. Install the lock nuts on top of the positioning collar and tighten. Now tighten the lower jam nuts firmly against the upper adjusting nuts to secure them for future removal of the sensor for inspection or service. Note: Take care not to get any grease on the impellor or bearing.

FLOW METER INSTALLATION ALIGNMENT OF FLOW METER Loosen positioning collar set screws with a 3/32 Allen wrench. Place the alignment rod through the sight holes in the Flow Sensor. Using the alignment rod as a guide, align the flow sensor so that the flow label arrow matches pipe flow direction and so that alignment rod is exactly parallel to the pipe. (Refer to Figure 3). Figure 3 This procedure aligns the impeller into the fluid flow. As a backup to the flow label, there is a small hole next to the larger sighting hole of the upstream side. With a 3/32 Allen wrench, tighten positioning collar screws. Double check that the sighting holes in the sleeve to make sure they are parallel down the pipe and that the flow arrow label matches pipe liquid flow direction. Cable routing: the positioning collar is threaded for connection of a standard ½ electrical conduit (Flex cable) or a wire strain relief. Route cable as required. Be sure to leave enough flex in cable or conduit to allow future removal of sensor for service or cleaning if necessary.

FLOW METER INSTALLATION FLOW METER TRANSIENT PROTECTION FOR LIGHTNING PRONE AREAS.

FLOW METER INSTALLATION TECHNICAL BULLETIN 2075 Corte del Nogal, Suite P, Carlsbad CA 92011 1-(800)-572-8608 FAX: 1-(760)-438-2619 www.calsense.com Stock Number: PG1-FM-C Rev. 03/06