COELMO S GEN SETS DM series

Similar documents
P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Marine Generating Sets 3.7 to 50 kva

ECOCIAT. Domestic hot water heat recovery unit

Diesel Generating Set

Magnum Mobile Generator MMG55 Specifications

Installation, operation and maintenance manual TX 35A

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Diesel Engine Driven Generators Page 1 of 6

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

The Yachtmans Choice...

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Thyristor-controlled power supplies and battery chargers

Technical specifications. Containerized data centre NTR CDC 40f+

Atlas Copco Generators

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Centro-Matic Automatic Lubrication Systems System Controls

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

AIR-CONDITIONER SPLIT TYPE

SPEEDROC D30. Surface Drill Rig for marble, granite, sandstone and limestone in the dimension stone industry.

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

Stroom voor elke toepassing

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Topvex SX/C, Topvex TX/C. Air Handling Unit

MPR-Systems. Mini Power Racks 1200 W W

Process Alarm Solutions

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Split units TH with hermetic compressors

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET


Designed for multi-injector endurance testing, the

Phase Modular Finally the benefits of Modular ups are for all

Overheating limit control

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

1300 MAXTRAK SPECIFICATION

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Photovoltaic Solar Energy Unit EESFB

YCAA-B AIR COOLED LIQUID CHILLER

CRAC Precision climate control units for data centres

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

C18 ACERT Fire Pump Tier bkw/ rpm

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

FIREDEX Conventional Fire Panels

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Appendix - Controllers 179

Technical data UNIBLOCK UBSF

HP switch LP switch Discharge thermo Comp. Surface thermo

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

The space saving solution.

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Refrigeration Compressed Air Dryer Buran Ultrapulse

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

Freezers - Ultrafreezers. Platilab & Irilab Series

Annex-A TECHNICAL SPECIFICATION

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

ELECTRIC INSTANTANEOUS WATER HEATER

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

RRV934. Multi-controller. Synco living

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

Power consumption (kw)

M1000 Process Alarm Monitor

Power Generation. Power Control PCL System Generator Set Control

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

CoolTeg Plus Chilled Water (CW) version: AC-TCW

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

The kva RAnge

Midland Combustion Electric Line Heaters with Integral Panels

The State Fire Marshal's Office and the VDH/Office of Licensure and Certification. Generator Testing in Nursing Facilities

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

EFC Frequency converters

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

OPERATING INSTRUCTIONS

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

Hydraulic Control Solutions

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

COMMISSIONING OF HVAC SYSTEMS

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

ESP PANELS TM & SYSTEM COMPONENTS. Instruction and connection manual

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Transcription:

WWW.JEEPSEA.CO.IL COELMO S GEN SETS DM series

COMPARISON DM 350 GENSET WITH COMPETITION ( Power, main sizes and weight ) Power kw Builder Model engine base main sizes mm Length Width Height Weight Kg 3,5 COELMO marine DM 350 Faryman 18 W 615 445 525 105 3,8 Fischer Panda PMS 4500 SCB Faryman 18 W 520 370 520 117 3,0 MASE IS 3,5 Yanmar 1 cylinder 590 406 515 96 3,5 VOLPI Paguro 4000 Faryman 18 W 550 320 520 83

COMPARISON DM 600 GENSET WITH COMPETITION ( Power, main sizes and weight ) Power kw Builder Model engine base main sizes mm Weight Length Width Height Kg 6,0 COELMO marine DM 600 NANNI N2.10 (Kubota Z 482) 630 465 525 128 5,1 Fischer Panda PMS 6000 ND Kubota Z 482 595 440 600 164 5,7 MASE GS 061 Kubota Z 482 650 468 555 165 5,0 Mastervolt Whisper 6 Mitsubishi L2E 660 495 550 178 5,0 VOLPI Paguro 6000 Lombardini LDW 502 660 460 620 130

DM600 Main features Aluminium sound proof canopy with polyester marine paint Sound proof material with PVC plate Large access possibility on the 5 sides Water cooling system: - engine cooled by heat exchanger sea water / fresh water - alternator cooled by sea water Hydraulic and electric connections located on the same side Electronic remote control and protection system Easy installation on board Reduced dimensions Low noise level Large accessories range 4

DM600 5

DM600 Holes for Siphon breaker piping on both sides 6

DM600 Hydraulic links Fuel inlet & outlet Sea water inlet Exhaust outlet Electric links Battery cables inlet Power cable outlet Signal cable All on the same side 7

DM600 Large access trough every 5 sides to allow the Genset checking and maintenance Possibility to dismantle the canopy in every part to extract the Genset and to put it in open version in the case of extraordinary maintenance 8

DM600 Complete local control board with: Genset circuit breaker Local/remote selector 9

DM600 Possibility of fast replacing of diodes trough this door 10

DM600 Ordinary maintenance concentrated on the front side : > sea water pump, > oil filter > alternator belt 11

DM600 Fuel feeding and return and sea water inlet piping for a fast and easy installation 12

DM600 Genset circuit breaker Local/remote selector 13

EOS Generator Advanced Controller Backlight display 128x64 pixels Control panel 96 x 96 mm to install on board with possibility to interface it with pre-existing systems (SCADA or similar) 14

EOS Generator Advanced Controller ALARMS Low oil pressure High water temperature High exhaust temperature Alternator battery charger failure Fault start Mechanical failure High frequency generator Maintenance deadline MEASURES Amp, Volt Hz Vcc Time counter Maintenance remaining hours Water temperature (optional) Oil pressure (optional) The display allows to visualize alarm messages as reported in the table. Each of these alarms will be visualized and could be set to provide only signal, engine stop, or start siren relay Other than the alarms are checkable also the principal measures. Generator overload Low battery voltage Low alternator voltage High alternator voltage Low frequency generator 15

DM600 wiring diagram Wiring diagram 1 16

DM600 wiring diagram Wiring diagram 2 17

DM350 Main features Aluminium sound proof canopy with polyester marine paint Sound proof material with PVC plate Large access possibility on the 5 sides Water cooling system: > engine cooled by heat exchanger sea water / fresh water > alternator cooled by sea water Hydraulic and electric connections located on the same side Electronic remote control and protection system Easy installation on board Reduced dimensions Low noise level Large accessories range 18

DM350 19

DM350 Hydraulic links Fuel inlet & outlet Sea water inlet Exhaust outlet Electric links Battery cables inlet Power cable outlet Signal cable All on the same side 20

DM350 Large access trough every 5 sides to allow the Genset checking and maintenance Possibility to dismantle the canopy in every part to extract the Gen set and to put it in open version in the case of extraordinary maintenance 21

DM350 Complete local control board with: Genset circuit breaker Local/remote selector High exhaust temperature switch 22

DM350 The DM350 cooling system works using exclusively sea water as cold fluid. This system has allowed to reduce the overall dimensions and the weight, in addition to the noise level reduction. Ordinary maintenance concentrated on the front side: - sea water pump - fuel filter 18/02/2008 23

DM350 Wiring diagram 1 24

DM350 Wiring diagram 2 25