Serial Port Connections

Similar documents
Modbus RTU Master Communications

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Moxa TCC-100/100I User s Guide

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

Cable Pinouts. SRP I/O Module

Connector and Cable Specifications

Cable Specifications. T3 Trunk Cabling APPENDIX

Computer Control of Satellite Antennas

RS-232 COMMUNICATIONS

Comtrol Cable User Guide

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

Table of Contents. Page Number. PLC Connections 1 Cable Solutions for Omron PLCs 11 Cable Solutions for Multi-Vendor PLCs 15

Cable Specifications and Information

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Manual Serial PCI Cards

Modbus RTU Master Communications

HSG Engineering Tech Bulletin

Cable Guide Including all PortServer TS, Digi Connect, and Digi One Products

Cable Specifications and Information

Connectors and Cables

1-Port R422/485 Serial PCIe Card

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

OPT SERIAL TO FIBER OPTIC CONVERTER

Paragon Explorer Lite Communication Software

PCMCIA 1 Port RS EDITION OCTOBER 1999

VSCOM USB PRO Series Industrial I/O Adapters

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number Positioning Controller

2-Port RS232/422/485 Combo Serial PCI Card

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

ISHIDA BC Scale to Scale Communications

M-Bus Network Installation Notes

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

Making a DB to RJ45 adapter.

Advanced Data Capture and Control Systems

Cabling Guide for Console and AUX Ports

PCS0100en Persy Control Services B.V. Netherlands

ATS Communication Overview

MechoNet TM Network Interface (MNI) Specification Submittal

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

IMACS. Cable and Equipment Guide. Premisys Communications. Integrated Multiple Access Communications Server. Publication Revision A2

Module Connectors and Cable Specifications

Application Note 83 Fundamentals of RS 232 Serial Communications

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.

Connector and Cable Specifications

Model 201 Wiegand Touchpad Reader Installation Guide

Modbus Communications for PanelView Terminals

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Elettronica dei Sistemi Digitali Costantino Giaconia SERIAL I/O COMMON PROTOCOLS

EasySYNC Ltd. USB to Serial Converters Manual

APPLICATION NOTE. Leased Line Modem. Leased Line Modem...3. Introduction Key Concepts... 4

Using Xbee in Serial Communication

RS-232/422/485, Power over Ethernet

s!nus-elektrotechnikai bt. Industrial IT & Automation

RS-422 and RS-485 Application Note

RS485 & RS422 Basics

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Smartio C168H/PCI User s Manual

RS232 Data Interface a Tutorial on Data Interface and cables

G.703 Fractional T1 Access Unit. User Guide

Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science Microprocessor Project Laboratory

TIMING SIGNALS, IRIG-B AND PULSES

RJ11 RS-232 Interface

KOM200. Industrial Serial to Fiber Media Converter. User s Manual

Using installed Fieldbus Wiring to carry Ethernet Communications

s!nus-elektrotechnikai bt. Industrial IT & Automation

Pmod peripheral modules are powered by the host via the interface s power and ground pins.

Bluetooth UART/RS232 Module

One Port Serial Server Users Manual Model ESP901, ESP901E

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

User Manual IC-485AI

NPort DE-311 Hardware Installation Guide

Gold Eagle HV Gold Eagle HV Cable Kit (EtherCAT and CAN)

SyncLink GT2/GT4 Serial Adapter

Power Supply and Cabling Options. SmartTrak 100/101/140

RS-485 the Murphy Way!

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

400 Series - Mini USB Buccaneer

MFRD52x. Mifare Contactless Smart Card Reader Reference Design. Document information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

CIN::APSE MICROMINIATURE D-SUB

Cabling Specifications

Telebyte 209 Short Haul Modem

LocoNet, the Digitrax Difference

Table of Contents. Creating a VC1000 Network... 3

INSTALLATION and OPERATION MANUAL

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

HARDWARE MANUAL. BrightSign HD120, HD220, HD1020. BrightSign, LLC Lark Ave., Suite 200 Los Gatos, CA

RC2200DK Demonstration Kit User Manual

Appendix A. This Appendix includes the following supplemental material:

USB to RS-422/485 Serial Adapter

485USBTB-2W & 485USBTB-4W

EDI Distributor Control Interface Wiring and Setup Instructions

IMVIB. Online vibration monitoring for Ariel compressors

Omron I/O Driver (Series 2) Programmable Serial Interface Card

Encore Controller to Router Connections

ROLINE THE Difference

Transcription:

Serial Port Connections PORT 5 RS PORT RS45 Providing Power to an External Device from Port If either port is set up for communications with a serial device that requires 00mA or less at 5VDC, the device can obtain power from Port. Cable Lengths and Baud Rates Maximum cable lengths (the total number of feet from the CPU to the last device attached to the cable) are: Port (RS-) = 5 meters (50 ft.) Port (RS-45) = 00 meters (4000 ft.) Both ports support configurable baud rates, as listed in the CPU descriptions in this manual. The following pre-assembled cables are available: IC00CBL00 IC00CBL00 CPU Programming Cable RS Expansion Firmware Upgrade Cable 4- VersaMax PLC User's Manual March 00 GFK-50C

Port : RS- Pin Assignments for Port Port is an RS- port with a 9-pin female D-sub connector. It is used as the boot loader port for upgrading the CPU firmware. The pinout of Port allows a simple straight-through cable to connect with a standard AT-style RS- port. Cable shielding attaches to the shell. Pin Signal Direction Function n/c TXD Output Transmit Data output RXD Input Receive Data input 4 n/c 5 GND 0V/GND signal reference 6 n/c 7 CTS Input Clear to Send input RTS Output Request to Send output 9 n/c Shell SHLD Cable Shield wire connection / 00% (Continuous) shielding cable shield connection RS- Point to Point Connection In point-to-point configuration, two devices are connected to the same communication line. For RS-, the maximum length is 5 meters (50ft). 6 7 9 4 5 4 5 6 7 9 PC 9-Pin CPU Serial Port Port 9-pin female 9-pin male () RXD () TXD () TXD () RXD (5) GND (5) GND (7) RTS (7) CTS () CTS () RTS The shield must connect to shell of connectors on both ends of the cable. GFK-50C Chapter 4 Installation 4-

and Cable Specifications for Port Vendor Part numbers below are provided for reference only. Any part that meets the same specification can be used. Cable: Belden 960 9 Pin Male : Shell: Computer cable, overall braid over foil shield 5 conductor 0 Volt / 0 C (76 F) 4 AWG tinned copper, 7x stranding Type: Crimp Solder Vendor: Plug: DEA9PK7F0 0504- ZDE9P 747904- Pin: 00-47-07 66506-9 Kit * ITT Cannon DE07-54 [9-pin size backshell kit]: Metal-Plated Plastic (Plastic with Nickel over Copper) Cable Grounding Clamp (included) 40 cable exit design to maintain low-profile installation Plus ITT Cannon 50-50-00 [Extended Jackscrew]: Threaded with #4-40 for secure attachment to CPU00 port Order Qty for each cable shell ordered Critical Information any other part selected should meet or exceed this criteria. * Use of this kit maintains the 70mm installed depth. 4-4 VersaMax PLC User's Manual March 00 GFK-50C

Port : RS-45 Pin Assignments for Port Port is an RS-45 port with a 5-pin female D-sub connector. This can be attached directly to an RS-45 to RS- adapter. Pin Signal Direction Function SHLD Cable Shield Drain wire connection,, 4 n/c 5 P5V Output +5.VDC to power external devices (00mA max.) 6 RTSA Output Request to Send (A) output 7 GND 0V/GND reference signal CTSB Input Clear to Send (B) input 9 RT Resistor Termination (0 ohm) for RDA 0 RDA Input Receive Data (A) input RDB Input Receive Data (B) input SDA Output Transmit Data (A) output SDB Output Transmit Data (B) output 4 RTSB Output Request to Send (B) output 5 CTSA Input Clear to Send (A) input Shell SHLD Cable Shield wire connection / 00% (Continuous ) shielding cable shield connection and Cable Specifications for Port Vendor Part numbers below are provided for reference only. Any part that meets the same specification can be used. Cable: Belden 05 5 Pin Male : Shell: Low Capacitance Computer cable, overall braid over foil shield 5 Twisted-pairs Shield Drain Wire 0 Volt / 0 C (76 F) 4 AWG tinned copper, 7x stranding Velocity of Propagation = 7% Nominal Impedance = 00Ω Type: Crimp Solder Vendor: Plug: DAA5PK7F0 0506- ZDA5P 74790- Pin: 00-47-07 66506-9 Kit* ITT Cannon DA07-50 [5-pin size backshell kit]: Metal-Plated Plastic (Plastic with Nickel over Copper) Cable Grounding Clamp (included) 40 cable exit design to maintain low-profile installation Plus ITT Cannon 50-50-009 [Extended Jackscrew]: Threaded with (metric) Mx0.5 for secure attachment Order Qty for each cable shell ordered Critical Information any other part selected should meet or exceed this criteria. GFK-50C Chapter 4 Installation 4-5

RS-45 Point to Point Connection with Handshaking In point-to-point configuration, two devices are connected to the same communication line. For RS-45, the maximum cable length is 00 meters (4000 feet). Modems can be used for longer distances. Computer RD ( A' ) RD ( B' ) SD ( A ) SD ( B ) CTS ( A' ) CTS ( B' ) RTS ( B ') RTS ( A ) GND SHLD Shielded Twisted Pairs Up to 5. meters (50 ft) without isolation 0 9 6 4 5 7 PLC SD ( A ) SD ( B ) RD ( A' ) RD ( B ' ) RT RTS ( A ) RTS ( B ) CTS ( B' ) CTS ( A' ) GND SHLD 4-6 VersaMax PLC User's Manual March 00 GFK-50C

RS-45 Multidrop Serial Connections In the multidrop configuration, the host device is configured as the master and one or more PLCs are configured as slaves. The maximum distance between the master and any slave may not exceed 4000 feet (00 meters). This figure assumes good quality cables and a moderately noisy environment. A maximum of slaves can be connected using RS-45 in a daisy chain or multidrop configuration. The RS-45 line must include handshaking and use wire type as specified earlier. Master Slave Station Last Station When wiring RS-45 multidrop cables, reflections on the transmission line can be reduced by daisy-chaining the cable as shown below. Make connections inside the connector to be attached to the PLC. Avoid using terminal strips to other types of connectors along the length of the transmission line. Computer RS- Port 9 Pin Male RD TD RTS 7 CTS DCD DTR 4 GND 5 9-Pin Female to 5- Pin Male RS- Shielded Cable (NC) RD TD 5 CTS 0 DTR DCD 7 GND SHLD RS-/RS-45 Converter IC690ACC900 DCD(A) DCD(B) RD(A ) 0 RD(B ) SD(A) SD(B) RT 9 CTS(A ) 5 CTS(B ) RTS(A) 6 RTS(B) 4 +5V 5 0V 7 SHLD RS-45 Cables Make connections inside D-connectors SD(A) SD(B) 0 RD(A ) RD(B ) 9 RT 6 RTS(A) 4 RTS(B) 5 CTS(A ) CTS(B ) 5 +5V 7 0V SHLD CPU RS-45 Port 5 Pin Female 5-5- FEMALE FEMALE RS- RS-45 PORT PORT Power Source for Converter. Must be wired no less than meters (0 feet) from the converter. 5- MALE 5V 0V TO OTHER PLC's Termination resistance for the Receive Data (RD) signal must be connected only on units at the ends of lines. This termination is made at the CPU by connecting a jumper between pin 9 and pin 0 inside the D-shell connector. Ground Potential: Multiple units not connected to the same power source must have common ground potential or ground isolation for proper operation of the system. GFK-50C Chapter 4 Installation 4-7