T-1 Series Circuit Breakers. Thermal Circuit Breakers. Thermal Circuit Breakers. 2001/2002 Marine Electrical Products 11

Similar documents
Reliable on land or sea. UL 1500 Ignition proof. ABYC compliant. High interrupt capacity. Mechanical Products Company

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Thermal-Magnetic Circuit Breaker M1-..

Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Bulletin 1489 Circuit Breakers. Selection Guide

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Magnetic Circuit Protectors 39. Configurations 44

2 p o l e p r o t e c t i o n. S w i t c h / C i r c u i t Protector t o 3 0 A m p. S e r i e s 2 4. C o u n t o n i t.

Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.

Contractors Guide Central Inverter System Installation

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING

Electronic overload relay EF65, EF96 and EF146

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Model SETR-50 and SETR-51 Trim Tab Control

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

400 Series Buccaneer BUCCANEER POWER. bulgin

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Circuit Breakers. NRC Series. NRC Series

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

Installation and Operation Guide for PD4000 Series Power Control Center

INSTALLATION & SERVICE MANUAL. Display Panel

Tmax MCCBs. Molded case circuit breakers. Tmax

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Electronic overload relay EF19 and EF45

User s Manual Before using the inverter, you need to read and save the safety instructions.

FIREDEX Conventional Fire Panels

AP/UP, AP/MIL Series. Magnetic Circuit Protectors

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Installation Instructions

RM4TG20 three-phase network control relay RM4-T - range V

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

HM-W536 Install Guide

16/32 Channel 1U Rack Mount CCTV Power Supply

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

RAY-MAX Integrated Solar Power Strip

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

Type NT and Type ZWM Terminal Blocks

Sentron Series Circuit Breakers

Solid-State Timer H3G

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

WE-350 Series ¼ Turn Electric Actuator

POWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE

Technicaldata General

FLB Series Circuit Breakers and Enclosures

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Installation & User Manual Radio Remote rev1.0.3

12-Volt Negative Ground Installation Instructions

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Type: DILM9 10(24VDC) Article No.:

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

ST Series POWER SUPPLIES USER INSTRUCTIONS

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Miniature Circuit Breakers and Supplementary Protectors

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

TSn SERIES Surge Protective Device

Switches SWITCHES SWITCHES

Catalog January. Heavy industrial power applications Motor contactors and starters

What is a multimeter?

7000 Series Buccaneer

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Phone: Fax: Web: info@clrwtr.com

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

Westinghouse AB DE-ION Current Limiting Circuit Breakers

70-Series CAN Power Management System

AZ420 MINIATURE GENERAL PURPOSE RELAY

Rotary Disconnect Switch Specifications

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

I N N O V A T I VSEO L U T I O N I SN S E N S O R SA N D C O N T R O L S. Precision Products Aircraft Circuit Breakers

4KVA/5KVA Parallel Installation Guide

E2 Series Electric Furnaces

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

12-Volt 10-Amp Regulated Power Supply

Air-cooled Generator Battery Charger Installation Guidelines

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

Givare NC-SRS 280 och 880

POWER TRIM 5 F AUTO TRIM AND AUTO TRIM

How To Protect A Motor From Overcurrent

ELECTRIC CONVECTION BUILT-IN OVEN

VLT Series 300 Watt True Sine Wave Inverter

Installation and Operation Guide PD4600 Series Converter Replacement

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

GTEC transfer switch open transition

MCR1900 Media Converter 19-Slot Chassis

Transcription:

Bellingham, Washington USA 7033 Bellingham, Washington USA 7133 T-1 Series s T-1 Series s Vapor Proof (conforming to SAE J1171) safe for installation aboard gas-powered boats Weatherproof Combines switching and circuit breaker function into one unit Trip Free designed to trip when subjected to a fault current, even if the reset lever is held in the position. Agency Meets SAE J553 & J1625 Standards for Surface Vehicles. Meets SAE J1428 & J1171 Marine Circuit Breaker Standards Including External Ignition Protection Subject to change Class Type III Switchable / Manual Reset Trip Free Type Thermally Responsive Bi-Metal Blade Body Material Thermoset Polyester, UL Rated 94V-0, 338 F (170 C) Amperage Range 25 to 150 Amperes Voltage Rating 48 Volt DC Maximum Interrupt Rating DC 5,000 Amperes @ 24 Volts 0.50 Lb / 0.23 Kg Panel Mount 0.58 Lb / 0.26 Kg Surface Mount Surface Mount 7126 Recessed mounting holes for clean appearance Large lever with vertical/horizontal orientation provides clear indication of trip status Robust 5/16 terminals provide high torque connections Available in June 2001 Trip-free designed to trip when subjected to a fault current, even if the reset lever is held in the position Clear, single lever operation Large clearance around terminal studs accepts large gauge wire lugs Panel Mount 7026 Self-trimming case eliminates need for mounting panels or trim bezels 5000 Ampere interrupt capacity meets primary circuit protection requirements for large DC systems Trip-free designed to trip when subjected to a fault current, even if the reset lever is held in the position Clear, single lever operation Round case permits easy installation with standard hole saw Recessed mounting holes for clean appearance Large lever with vertical/horizontal orientation provides clear indication of trip status MOUNTING HOLE FOR #10 OR M5 SCREW 0.300" 7.62mm MOUNTS IN 2.125 53.97mm DIA. HOLE 1.625" 41.28mm MOUNTING HOLE FOR #10 OR M5 SCREW 3.386 86.01mm TRIP 150 AMPERES Ignition Protected Waterproof Breaker 48 Volts DC Maximum 5000 Ampere Interrupt 2.750" 69.85mm 2.125" 53.97mm 2.105" 53.47mm 3.439 87.35mm TRIP 150 AMPERES Ignition Protected Waterproof Breaker 48 Volts DC Maximum 5000 Ampere Interrupt 2.562" 65.07mm 2.125" 53.97mm 2.260" 57.42mm 0.732" 18.59mm 1.750" 44.45mm 5/16-18 TERMINAL STUD 2.323" 59.00mm 5/16-18 TERMINAL STUD 1.797" 45.64mm TOP Panel Mount SIDE TOP Surface Mount SIDE 10 Blue Sea Systems

T-1 Series s Panel Surface Mount Mount Description 7020 7120 T-1 25 Amp 7021 7121 T-1 30 Amp 7022 7122 T-1 35 Amp 7023 7123 T-1 40 Amp 7024 7124 T-1 50 Amp 7025 7125 T-1 60 Amp 7026 7126 T-1 70 Amp 7027 7127 T-1 80 Amp 7028 7128 T-1 90 Amp 7029 7129 T-1 100 Amp 7030 7130 T-1 110 Amp 7031 7131 T-1 120 Amp 7032 7132 T-1 135 Amp 7033 7133 T-1 150 Amp T-1 Series 48 Volts DC Maximum 25 to 150 Amperes Thermal s Thermal s Vapor Proof (conforming to SAE J1171) safe for installation aboard gas-powered boats Waterproof Combines switching and circuit breaker function into one unit Trip Free cannot be held closed after trip 2.900" 1.550" 73.66mm 39.37mm MOUNTING HOLE FOR 1/4" SCREW 2.375" 60.33mm Interrupt Capacity Type Body Material 3000 Amperes Thermal 30 Volts DC 0.24 Lb / 0.11 Kg Panel Mount 0.30 Lb / 0.14 Kg Surface Mount 7100 7001 MOUNTING HOLE FOR 1/4" SCREW 1/4" STUD 1.900" 48.26mm Panel Surface Mount Mount Description 7005 7105 40 Amp 7000 7100 50 Amp 7001 7101 75 Amp 7002 7102 100 Amp 7003 7103 125 Amp 7004 7104 150 Amp 7198 Mounting Bezel for 700x s 7199 Mounting Panel for 700x s B A T 2.900" 2.250" 73.66mm 57.15mm A U X 1.050" 1.900" 48.26mm High Amperage MOUNTING HOLE FOR 1/4" SCREW 30 Volts DC 40 to 150 Amperes 7198 4.000" 101.60mm 3.000" 76.20mm 7199 2.375" 60.33mm 1.000" 25.40mm 2001/2002 Marine Electrical Products 11

DC s 7266 7270 7271 7244 7246 7248 7250 DC C-Series High-Load s 50 to 300 Ampere range provides overcurrent protection previously only available in fuses for: Inverters Bow Thrusters Windlasses Combines switching and circuit protection into a single device Trip Free cannot be held closed after trip LED indicates power (in panel mounted) Panel Material Panel Undercoating Panel Front Coating Rated Switch Cycles LED Amperage Dimensions 0.125" Aluminum 5052 Alloy Chemical Treatment Mil-C-5541C or equivalent 2-Part Polyurethane Slate Gray 65 Volts DC 10,000 @ rated amperage and voltage 5 Milliwatts 5.25" / 133.40 mm high 3.75" / 95.25 mm wide CSeries DC Single Pole 50100A UL 1077 UL/CSA (US/Canada) 1 Voltage Current w/o EN 60934 VDE (Europe) w/o 65 VDC 71 100A 5000A 100A RK5 80 VDC 0.1 70A 7500A 80 VDC 0.1 100A** 10,000A 5000A CSeries DC Double & Triple Pole 150300A 65 VDC 110 300A 10,000A ** UL Listed Units Only Panel Circuit Circuit Breaker Breaker Description Lb/Kg 7272* 7244* Panel DC 50A C-Series 1 pole 0.36/0.17 7273* 7246* Panel DC 60A C-Series 1 pole 0.36/0.17 7274* 7248* Panel DC 80A C-Series 1 pole 0.36/0.17 7259* 7250* Panel DC 100A C-Series 1 pole 0.36/0.17 7262 7267 Panel DC 150A C-Series 2 pole 0.64/0.31 7263 7268 Panel DC 175A C-Series 2 pole 0.64/0.31 7264 7269 Panel DC 200A C-Series 2 pole 0.64/0.31 7265 7270 Panel DC 250A C-Series 3 pole 0.93/0.46 7266 7271 Panel DC 300A C-Series 3 pole 0.93/0.46 * UL 489 Listed UL 489A Listed 7267 7268 7269 12 Blue Sea Systems

I I AC s 2.500" 2.062" 63.50mm 52.37mm 0.406" 10.31mm 0.219" 5.56mm 50-100 Ampere AC/DC 2.475" 62.86mm 1.850" 47.0mm LINE LOAD 0.150" 3.81mm Side View Typical #6-32 [M3] THREAD TYPICAL 1.438" 36.53mm 1.940" 2.500" 49.28mm 63.50mm 1/4" STUD 1.500" 38.10mm 150-200 Ampere DC 0.281" 7.14mm See C-Series Mounting Panels page 32 7251 2.280" 57.91mm 1.520" 38.61mm 0.760" 19.30mm 2.062" 1.448" 52.37mm 36.78mm 0.432" 10.97mm 7244 2.250" 57.15mm 250-300 Ampere DC Panel Cutout Detail TYP TYP PER POLE AC C-Series s 5000 Ampere Interrupt Capacity to meet ABYC requirements for 120/240 Volt 50 Ampere Main Protection Trip Free design cannot be held during fault current condition Type Body Material Maximum Amperage 100 Amperes 250 Volts AC Description Lb/Kg 7244* CA1 50A White 0.28/0.13 7246* CA1 60A White 0.28/0.13 7248* CA1 80A White 0.28/0.13 7250* CA1 100A White 0.28/0.13 7251* CA2 50A White 0.56/0.26 7254 CA2 60A White 0.56/0.26 7256 CA2 80A White 0.56/0.26 7258 CA2 100A White 0.56/0.26 * UL 489 Listed CSeries AC Single Pole 50100A UL 1077 UL/CSA (US/Canada) 1 Voltage Current w/o CSeries AC Double Pole 50100A 65 Volts DC - 250 Volts AC 5 to 50 Amperes Medium Delay Curve No. 34 EN 60934 VDE (Europe) w/o 120 VAC 0.1 70A** 0.1 100A 10,000A 1000A 5000A 100A RK5 125A gl 71 100 5000A 100A RK5 250 VAC 0.1 100 5000A 100A RK5 125/250 VAC 250 VAC 0.1 50A 0.1 70A 120/240 VAC 71 100A 120/240 VAC 0.1 50A** 1000A 5000A 5000A 125A RK5 5000A 175A RK5 5000A 175A RK5 125A gl ** UL Listed Units Only 1.500 38.10mm CARLINGSWITCH LOCKOUT SLIDE C-Series AC Lockout Slide 2.905 73.79mm Allows only 1 of a pair of double-pole AC circuit breakers to be activated at a time Guarantees that AC power from 2 sources (power company and genset or inverter) will not be mixed Fits all double-pole C-Series circuit breakers shown Uses circuit breaker mounting screw holes. Requires no special panel modification Includes 4 mounting screws 2.955 75.06mm Material Mounting Screw Size Acetal #6 Flat Head Screw Description Lb/Kg 4130 AC 2 Positon Lockout Slide 0.06/0.03 2001/2002 Marine Electrical Products 13

s Single Pole AC/DC s The industry standard circuit breaker for Blue Sea Systems electrical panels Combines switching and circuit protection into a single device B-Series circuit breakers are E marked Quick Trip models are designed specifically for electronics protection B-Series E Type Material Maximum Amperage Rated Switch Cycles 50 Amperes 65 Volts DC / 277 Volts AC 10,000 @ rated amperage and voltage 0.17 Lb / 0.08 Kg #6-32 [M3] THREAD 2 PLACES 2.000" 50.80mm 1.050" 0.156" DIA Ø3.96mm 1.660" 42.16mm 1.050" 0.630" DIA Ø16.00mm 14 ASeries Single Pole 550 Amp UL 1077 UL/CSA (US/Canada) 1 Voltage 65 VDC 277 VAC Current 0.1 50A 0.02 30A 31 50A 0.02 30A Blue Sea Systems w/o w/o 2000A 5000A 100A RK5 BSeries Single Pole 530 Amp UL 1077 UL/CSA (US/Canada) 1 Voltage Current w/o 65 VDC 250 VAC 0.1 50A 0.1 30A 31 50A 0.1 30A 2000A Quick Trip s 5000A 100A RK5 65 Volts DC - 277 Volts AC 5 to 50 Amperes Short Delay Curve No. 32 Standard A&B Series s EN 60934 VDE (Europe) 65 Volts DC - 250 Volts AC 5 to 50 Amperes Medium Delay Curve No. 34 EN 60934 VDE (Europe) w/o 100A gl 63A gl 63A gl 0.170" 4.32mm 1-Pole A & B-Series Quick Trip s B-Series E Description 7291 7296 1A White 7292 7297 2.5A White 7293 7298 5A White Standard Delay s B-Series E Description 7200 5A Black 7201 5A Red 7202 7275 5A White 7203 5A Yellow 7276 6A White 7277 8A White 7204 10A Black 7205 10A Red 7206 7278 10A White 7207 10A Yellow 7208 15A Black 7209 15A Red 7210 7279 15A White 7211 15A Yellow 7212 20A Black 7213 20A Red 7214 7280 20A White 7215 20A Yellow 7216 25A Black 7217 25A Red 7218 7281 25A White 7219 25A Yellow 7220 30A Black 7221 30A Red 7222 7282 30A White 7223 30A Yellow 7224 40A Black 7225 40A Red 7226 7283 40A White 7227 40A Yellow 7228 50A Black 7229 50A Red 7230 7284 50A White 7231 50A Yellow See page 30 for 8072 Mounting Panel TYP PER POLE Panel Cutout Detail

s Double Pole AC s The industry standard circuit breaker for Blue Sea Systems electrical panels Used as AC main circuit breakers to switch both hot and neutral legs With neutral circuit on one pole and hot circuit on other pole, both poles will trip if either pole trips Combines switching and circuit protection into a single device B-Series circuit breakers are E marked Type Material Maximum Amperage Rated Switch Cycles 50 Amperes 277 Volts AC 10,000 @ rated amperage and voltage 0.34 Lb / 0.16 Kg #6-32 [M3] THREAD 4 PLACES 0.156" DIA Ø3.96mm 2.000" 1.660" 50.80mm 1.050" 42.16mm 1.050" 0.170" 4.32mm 1.500" 38.10mm 2-Pole A & B-Series B-Series E 0.750 TYP PER POLE 0.630" DIA Ø16.00mm Panel Cutout Detail 125/250 Volts AC 10 to 50 Amperes Medium Delay Curve No. 34 ASeries Double Pole 1050 Amp UL 1077 UL/CSA (US/Canada) 1 Voltage Current w/o 65 VDC 125/250 VAC 125/250 VAC 277 VAC 0.1 50A 0.02 30A 31 50A 0.02 30A 2000A 5000A 100A RK5 BSeries Double Pole 16Amp UL 1077 UL/CSA (US/Canada) 1 Voltage Current w/o 65 VDC 0.02 50A 65 VDC 0.1 32A 125/250 VAC 0.02 30A 125/250 VAC 31 50A 2000A 250 VAC 0.1 32A 277 VAC 0.02 30A 5000A 100A RK5 B-Series E Description 7232 10A Black 7233 10A White 7234 15A Black 7235 15A White 7285 16A White 7236 20A Black 7260 20A White 7237 30A Black 7238 30A White 7286 32A White 7239 40A Black 7240 40A White 7241 50A Black 7242 50A White EN 60934 VDE (Europe) w/o EN 60934 VDE (Europe) w/o 63A gl 63A gl See page 31 for AC Double Pole Lockout Slide See page 30 for 8173 Mounting Panel 2001/2002 Marine Electrical Products 15